#307 PLC integration with new config storage
This commit is contained in:
@@ -4,58 +4,46 @@
|
||||
|
||||
require("/initenv").init_env()
|
||||
|
||||
local comms = require("scada-common.comms")
|
||||
local crash = require("scada-common.crash")
|
||||
local log = require("scada-common.log")
|
||||
local mqueue = require("scada-common.mqueue")
|
||||
local network = require("scada-common.network")
|
||||
local ppm = require("scada-common.ppm")
|
||||
local rsio = require("scada-common.rsio")
|
||||
local util = require("scada-common.util")
|
||||
local comms = require("scada-common.comms")
|
||||
local crash = require("scada-common.crash")
|
||||
local log = require("scada-common.log")
|
||||
local mqueue = require("scada-common.mqueue")
|
||||
local network = require("scada-common.network")
|
||||
local ppm = require("scada-common.ppm")
|
||||
local util = require("scada-common.util")
|
||||
|
||||
local config = require("reactor-plc.config")
|
||||
local databus = require("reactor-plc.databus")
|
||||
local plc = require("reactor-plc.plc")
|
||||
local renderer = require("reactor-plc.renderer")
|
||||
local threads = require("reactor-plc.threads")
|
||||
local configure = require("reactor-plc.configure")
|
||||
local databus = require("reactor-plc.databus")
|
||||
local plc = require("reactor-plc.plc")
|
||||
local renderer = require("reactor-plc.renderer")
|
||||
local threads = require("reactor-plc.threads")
|
||||
|
||||
local R_PLC_VERSION = "v1.5.10"
|
||||
local R_PLC_VERSION = "v1.6.0"
|
||||
|
||||
local println = util.println
|
||||
local println_ts = util.println_ts
|
||||
|
||||
----------------------------------------
|
||||
-- config validation
|
||||
-- get configuration
|
||||
----------------------------------------
|
||||
|
||||
local cfv = util.new_validator()
|
||||
|
||||
cfv.assert_type_bool(config.NETWORKED)
|
||||
cfv.assert_type_int(config.REACTOR_ID)
|
||||
cfv.assert_channel(config.SVR_CHANNEL)
|
||||
cfv.assert_channel(config.PLC_CHANNEL)
|
||||
cfv.assert_type_int(config.TRUSTED_RANGE)
|
||||
cfv.assert_type_num(config.COMMS_TIMEOUT)
|
||||
cfv.assert_min(config.COMMS_TIMEOUT, 2)
|
||||
cfv.assert_type_str(config.LOG_PATH)
|
||||
cfv.assert_type_int(config.LOG_MODE)
|
||||
|
||||
assert(cfv.valid(), "bad config file: missing/invalid fields")
|
||||
|
||||
-- check emergency coolant configuration
|
||||
if type(config.EMERGENCY_COOL) == "table" then
|
||||
if not rsio.is_valid_side(config.EMERGENCY_COOL.side) then
|
||||
assert(false, "bad config file: emergency coolant side unrecognized")
|
||||
elseif config.EMERGENCY_COOL.color ~= nil and not rsio.is_color(config.EMERGENCY_COOL.color) then
|
||||
assert(false, "bad config file: emergency coolant invalid redstone channel color provided")
|
||||
if not plc.load_config() then
|
||||
-- try to reconfigure (user action)
|
||||
local success, error = configure.configure(true)
|
||||
if success then
|
||||
assert(plc.load_config(), "failed to load valid reactor PLC configuration")
|
||||
else
|
||||
assert(success, "reactor PLC configuration error: " .. error)
|
||||
end
|
||||
end
|
||||
|
||||
local config = plc.config
|
||||
|
||||
----------------------------------------
|
||||
-- log init
|
||||
----------------------------------------
|
||||
|
||||
log.init(config.LOG_PATH, config.LOG_MODE, config.LOG_DEBUG == true)
|
||||
log.init(config.LogPath, config.LogMode, config.LogDebug)
|
||||
|
||||
log.info("========================================")
|
||||
log.info("BOOTING reactor-plc.startup " .. R_PLC_VERSION)
|
||||
@@ -75,32 +63,32 @@ local function main()
|
||||
|
||||
-- record firmware versions and ID
|
||||
databus.tx_versions(R_PLC_VERSION, comms.version)
|
||||
databus.tx_id(config.REACTOR_ID)
|
||||
databus.tx_id(config.UnitID)
|
||||
|
||||
-- mount connected devices
|
||||
ppm.mount_all()
|
||||
|
||||
-- message authentication init
|
||||
if type(config.AUTH_KEY) == "string" then
|
||||
network.init_mac(config.AUTH_KEY)
|
||||
if string.len(config.AuthKey) > 0 then
|
||||
network.init_mac(config.AuthKey)
|
||||
end
|
||||
|
||||
-- shared memory across threads
|
||||
---@class plc_shared_memory
|
||||
local __shared_memory = {
|
||||
-- networked setting
|
||||
networked = config.NETWORKED, ---@type boolean
|
||||
networked = config.Networked,
|
||||
|
||||
-- PLC system state flags
|
||||
---@class plc_state
|
||||
plc_state = {
|
||||
init_ok = true,
|
||||
fp_ok = false,
|
||||
shutdown = false,
|
||||
degraded = true,
|
||||
init_ok = true,
|
||||
fp_ok = false,
|
||||
shutdown = false,
|
||||
degraded = true,
|
||||
reactor_formed = true,
|
||||
no_reactor = true,
|
||||
no_modem = true
|
||||
no_reactor = true,
|
||||
no_modem = true
|
||||
},
|
||||
|
||||
-- control setpoints
|
||||
@@ -118,10 +106,10 @@ local function main()
|
||||
|
||||
-- system objects
|
||||
plc_sys = {
|
||||
rps = nil, ---@type rps
|
||||
nic = nil, ---@type nic
|
||||
plc_comms = nil, ---@type plc_comms
|
||||
conn_watchdog = nil ---@type watchdog
|
||||
rps = nil, ---@type rps
|
||||
nic = nil, ---@type nic
|
||||
plc_comms = nil, ---@type plc_comms
|
||||
conn_watchdog = nil---@type watchdog
|
||||
},
|
||||
|
||||
-- message queues
|
||||
@@ -196,18 +184,17 @@ local function main()
|
||||
|
||||
if plc_state.init_ok then
|
||||
-- init reactor protection system
|
||||
smem_sys.rps = plc.rps_init(smem_dev.reactor, plc_state.reactor_formed, config.EMERGENCY_COOL)
|
||||
smem_sys.rps = plc.rps_init(smem_dev.reactor, plc_state.reactor_formed)
|
||||
log.debug("init> rps init")
|
||||
|
||||
if __shared_memory.networked then
|
||||
-- comms watchdog
|
||||
smem_sys.conn_watchdog = util.new_watchdog(config.COMMS_TIMEOUT)
|
||||
smem_sys.conn_watchdog = util.new_watchdog(config.ConnTimeout)
|
||||
log.debug("init> conn watchdog started")
|
||||
|
||||
-- create network interface then setup comms
|
||||
smem_sys.nic = network.nic(smem_dev.modem)
|
||||
smem_sys.plc_comms = plc.comms(config.REACTOR_ID, R_PLC_VERSION, smem_sys.nic, config.PLC_CHANNEL, config.SVR_CHANNEL,
|
||||
config.TRUSTED_RANGE, smem_dev.reactor, smem_sys.rps, smem_sys.conn_watchdog)
|
||||
smem_sys.plc_comms = plc.comms(R_PLC_VERSION, smem_sys.nic, smem_dev.reactor, smem_sys.rps, smem_sys.conn_watchdog)
|
||||
log.debug("init> comms init")
|
||||
else
|
||||
_println_no_fp("init> starting in offline mode")
|
||||
@@ -215,7 +202,7 @@ local function main()
|
||||
end
|
||||
|
||||
-- notify user of emergency coolant configuration status
|
||||
if config.EMERGENCY_COOL ~= nil then
|
||||
if config.EmerCoolEnable then
|
||||
println("init> emergency coolant control ready")
|
||||
log.info("init> running with emergency coolant control available")
|
||||
end
|
||||
|
||||
Reference in New Issue