#159 linked up redstone I/O
This commit is contained in:
@@ -3,6 +3,8 @@ local rsio = require("scada-common.rsio")
|
||||
local types = require("scada-common.types")
|
||||
local util = require("scada-common.util")
|
||||
|
||||
local plc = require("supervisor.session.plc")
|
||||
|
||||
local ALARM_STATE = types.ALARM_STATE
|
||||
|
||||
local TRI_FAIL = types.TRI_FAIL
|
||||
@@ -10,6 +12,8 @@ local DUMPING_MODE = types.DUMPING_MODE
|
||||
|
||||
local IO = rsio.IO
|
||||
|
||||
local PLC_S_CMDS = plc.PLC_S_CMDS
|
||||
|
||||
local aistate_string = {
|
||||
"INACTIVE",
|
||||
"TRIPPING",
|
||||
@@ -620,4 +624,71 @@ function logic.update_status_text(self)
|
||||
end
|
||||
end
|
||||
|
||||
-- handle unit redstone I/O
|
||||
---@param self _unit_self unit instance
|
||||
function logic.handle_redstone(self)
|
||||
-- reactor controls
|
||||
if self.plc_s ~= nil then
|
||||
if (not self.plc_cache.rps_status.manual) and self.io_ctl.digital_read(IO.R_SCRAM) then
|
||||
-- reactor SCRAM requested but not yet done; perform it
|
||||
self.plc_s.in_queue.push_command(PLC_S_CMDS.SCRAM)
|
||||
end
|
||||
|
||||
if self.plc_cache.rps_trip and self.io_ctl.digital_read(IO.R_RESET) then
|
||||
-- reactor RPS reset requested but not yet done; perform it
|
||||
self.plc_s.in_queue.push_command(PLC_S_CMDS.RPS_RESET)
|
||||
end
|
||||
|
||||
if (not self.db.annunciator.AutoControl) and (not self.plc_cache.active) and
|
||||
(not self.plc_cache.rps_trip) and self.io_ctl.digital_read(IO.R_ACTIVE) then
|
||||
-- reactor enable requested and allowable, but not yet done; perform it
|
||||
self.plc_s.in_queue.push_command(PLC_S_CMDS.ENABLE)
|
||||
end
|
||||
end
|
||||
|
||||
-- check for request to ack all alarms
|
||||
if self.io_ctl.digital_read(IO.U_ACK) then
|
||||
for i = 1, #self.db.alarm_states do
|
||||
if self.db.alarm_states[i] == ALARM_STATE.TRIPPED then
|
||||
self.db.alarm_states[i] = ALARM_STATE.ACKED
|
||||
end
|
||||
end
|
||||
end
|
||||
|
||||
-- write reactor status outputs
|
||||
self.io_ctl.digital_write(IO.R_ACTIVE, self.plc_cache.active)
|
||||
self.io_ctl.digital_write(IO.R_AUTO_CTRL, self.db.annunciator.AutoControl)
|
||||
self.io_ctl.digital_write(IO.R_SCRAMMED, self.plc_cache.rps_trip)
|
||||
self.io_ctl.digital_write(IO.R_AUTO_SCRAM, self.plc_cache.rps_status.automatic)
|
||||
self.io_ctl.digital_write(IO.R_DMG_CRIT, self.plc_cache.rps_status.dmg_crit)
|
||||
self.io_ctl.digital_write(IO.R_HIGH_TEMP, self.plc_cache.rps_status.high_temp)
|
||||
self.io_ctl.digital_write(IO.R_NO_COOLANT, self.plc_cache.rps_status.no_cool)
|
||||
self.io_ctl.digital_write(IO.R_EXCESS_HC, self.plc_cache.rps_status.ex_hcool)
|
||||
self.io_ctl.digital_write(IO.R_EXCESS_WS, self.plc_cache.rps_status.ex_waste)
|
||||
self.io_ctl.digital_write(IO.R_INSUFF_FUEL, self.plc_cache.rps_status.no_fuel)
|
||||
self.io_ctl.digital_write(IO.R_PLC_FAULT, self.plc_cache.rps_status.fault)
|
||||
self.io_ctl.digital_write(IO.R_PLC_TIMEOUT, self.plc_cache.rps_status.timeout)
|
||||
|
||||
-- write unit outputs
|
||||
|
||||
local has_alarm = false
|
||||
for i = 1, #self.db.alarm_states do
|
||||
if self.db.alarm_states[i] == ALARM_STATE.TRIPPED then
|
||||
has_alarm = true
|
||||
break
|
||||
end
|
||||
end
|
||||
|
||||
self.io_ctl.digital_write(IO.U_ALARM, has_alarm)
|
||||
|
||||
-- check if emergency coolant is needed
|
||||
if self.plc_cache.rps_status.no_cool then
|
||||
self.valves.emer_cool.open()
|
||||
elseif not self.plc_cache.rps_trip then
|
||||
-- can't turn off on sufficient coolant level since it might drop again
|
||||
-- turn off once system is OK again
|
||||
self.valves.emer_cool.close()
|
||||
end
|
||||
end
|
||||
|
||||
return logic
|
||||
|
||||
Reference in New Issue