#488 HMAC acceleration and seq_num changes
This commit is contained in:
13
rtu/rtu.lua
13
rtu/rtu.lua
@@ -284,8 +284,7 @@ end
|
||||
function rtu.comms(version, nic, conn_watchdog)
|
||||
local self = {
|
||||
sv_addr = comms.BROADCAST,
|
||||
seq_num = 0,
|
||||
r_seq_num = nil,
|
||||
seq_num = util.time_ms() * 10, -- unique per peer, restarting will not re-use seq nums due to message rate
|
||||
txn_id = 0,
|
||||
last_est_ack = ESTABLISH_ACK.ALLOW
|
||||
}
|
||||
@@ -363,7 +362,6 @@ function rtu.comms(version, nic, conn_watchdog)
|
||||
function public.unlink(rtu_state)
|
||||
rtu_state.linked = false
|
||||
self.sv_addr = comms.BROADCAST
|
||||
self.r_seq_num = nil
|
||||
databus.tx_link_state(types.PANEL_LINK_STATE.DISCONNECTED)
|
||||
end
|
||||
|
||||
@@ -441,17 +439,15 @@ function rtu.comms(version, nic, conn_watchdog)
|
||||
|
||||
if l_chan == config.RTU_Channel then
|
||||
-- check sequence number
|
||||
if self.r_seq_num == nil then
|
||||
self.r_seq_num = packet.scada_frame.seq_num()
|
||||
elseif rtu_state.linked and ((self.r_seq_num + 1) ~= packet.scada_frame.seq_num()) then
|
||||
log.warning("sequence out-of-order: last = " .. self.r_seq_num .. ", new = " .. packet.scada_frame.seq_num())
|
||||
if self.seq_num ~= packet.scada_frame.seq_num() then
|
||||
log.warning("sequence out-of-order: last = " .. self.seq_num .. ", new = " .. packet.scada_frame.seq_num())
|
||||
return
|
||||
elseif rtu_state.linked and (src_addr ~= self.sv_addr) then
|
||||
log.debug("received packet from unknown computer " .. src_addr .. " while linked (expected " .. self.sv_addr ..
|
||||
"); channel in use by another system?")
|
||||
return
|
||||
else
|
||||
self.r_seq_num = packet.scada_frame.seq_num()
|
||||
self.seq_num = packet.scada_frame.seq_num() + 1
|
||||
end
|
||||
|
||||
-- feed watchdog on valid sequence number
|
||||
@@ -556,7 +552,6 @@ function rtu.comms(version, nic, conn_watchdog)
|
||||
-- establish allowed
|
||||
rtu_state.linked = true
|
||||
self.sv_addr = packet.scada_frame.src_addr()
|
||||
self.r_seq_num = nil
|
||||
println_ts("supervisor connection established")
|
||||
log.info("supervisor connection established")
|
||||
else
|
||||
|
||||
@@ -31,7 +31,7 @@ local sna_rtu = require("rtu.dev.sna_rtu")
|
||||
local sps_rtu = require("rtu.dev.sps_rtu")
|
||||
local turbinev_rtu = require("rtu.dev.turbinev_rtu")
|
||||
|
||||
local RTU_VERSION = "v1.9.6"
|
||||
local RTU_VERSION = "v1.10.0"
|
||||
|
||||
local RTU_UNIT_TYPE = types.RTU_UNIT_TYPE
|
||||
local RTU_UNIT_HW_STATE = databus.RTU_UNIT_HW_STATE
|
||||
|
||||
Reference in New Issue
Block a user