#488 HMAC acceleration and seq_num changes
This commit is contained in:
@@ -191,283 +191,282 @@ function supervisor.comms(_version, nic, fp_ok)
|
||||
end
|
||||
|
||||
-- handle a packet
|
||||
---@param packet modbus_frame|rplc_frame|mgmt_frame|crdn_frame|nil
|
||||
---@param packet modbus_frame|rplc_frame|mgmt_frame|crdn_frame
|
||||
function public.handle_packet(packet)
|
||||
if packet ~= nil then
|
||||
local l_chan = packet.scada_frame.local_channel()
|
||||
local r_chan = packet.scada_frame.remote_channel()
|
||||
local src_addr = packet.scada_frame.src_addr()
|
||||
local protocol = packet.scada_frame.protocol()
|
||||
local l_chan = packet.scada_frame.local_channel()
|
||||
local r_chan = packet.scada_frame.remote_channel()
|
||||
local src_addr = packet.scada_frame.src_addr()
|
||||
local protocol = packet.scada_frame.protocol()
|
||||
local i_seq_num = packet.scada_frame.seq_num() + 1
|
||||
|
||||
if l_chan ~= config.SVR_Channel then
|
||||
log.debug("received packet on unconfigured channel " .. l_chan, true)
|
||||
elseif r_chan == config.PLC_Channel then
|
||||
-- look for an associated session
|
||||
local session = svsessions.find_plc_session(src_addr)
|
||||
if l_chan ~= config.SVR_Channel then
|
||||
log.debug("received packet on unconfigured channel " .. l_chan, true)
|
||||
elseif r_chan == config.PLC_Channel then
|
||||
-- look for an associated session
|
||||
local session = svsessions.find_plc_session(src_addr)
|
||||
|
||||
if protocol == PROTOCOL.RPLC then
|
||||
---@cast packet rplc_frame
|
||||
-- reactor PLC packet
|
||||
if session ~= nil then
|
||||
-- pass the packet onto the session handler
|
||||
session.in_queue.push_packet(packet)
|
||||
else
|
||||
-- any other packet should be session related, discard it
|
||||
log.debug("discarding RPLC packet without a known session")
|
||||
end
|
||||
elseif protocol == PROTOCOL.SCADA_MGMT then
|
||||
---@cast packet mgmt_frame
|
||||
-- SCADA management packet
|
||||
if session ~= nil then
|
||||
-- pass the packet onto the session handler
|
||||
session.in_queue.push_packet(packet)
|
||||
elseif packet.type == MGMT_TYPE.ESTABLISH then
|
||||
-- establish a new session
|
||||
local last_ack = self.last_est_acks[src_addr]
|
||||
|
||||
-- validate packet and continue
|
||||
if packet.length >= 3 and type(packet.data[1]) == "string" and type(packet.data[2]) == "string" then
|
||||
local comms_v = packet.data[1]
|
||||
local firmware_v = packet.data[2]
|
||||
local dev_type = packet.data[3]
|
||||
|
||||
if comms_v ~= comms.version then
|
||||
if last_ack ~= ESTABLISH_ACK.BAD_VERSION then
|
||||
log.info(util.c("dropping PLC establish packet with incorrect comms version v", comms_v, " (expected v", comms.version, ")"))
|
||||
end
|
||||
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.BAD_VERSION)
|
||||
elseif dev_type == DEVICE_TYPE.PLC then
|
||||
-- PLC linking request
|
||||
if packet.length == 4 and type(packet.data[4]) == "number" then
|
||||
local reactor_id = packet.data[4]
|
||||
local plc_id = svsessions.establish_plc_session(src_addr, reactor_id, firmware_v)
|
||||
|
||||
if plc_id == false then
|
||||
-- reactor already has a PLC assigned
|
||||
if last_ack ~= ESTABLISH_ACK.COLLISION then
|
||||
log.warning(util.c("PLC_ESTABLISH: assignment collision with reactor ", reactor_id))
|
||||
end
|
||||
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.COLLISION)
|
||||
else
|
||||
-- got an ID; assigned to a reactor successfully
|
||||
println(util.c("PLC (", firmware_v, ") [@", src_addr, "] \xbb reactor ", reactor_id, " connected"))
|
||||
log.info(util.c("PLC_ESTABLISH: PLC (", firmware_v, ") [@", src_addr, "] reactor unit ", reactor_id, " PLC connected with session ID ", plc_id))
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.ALLOW)
|
||||
end
|
||||
else
|
||||
log.debug("PLC_ESTABLISH: packet length mismatch/bad parameter type")
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
|
||||
end
|
||||
else
|
||||
log.debug(util.c("illegal establish packet for device ", dev_type, " on PLC channel"))
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
|
||||
end
|
||||
else
|
||||
log.debug("invalid establish packet (on PLC channel)")
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
|
||||
end
|
||||
else
|
||||
-- any other packet should be session related, discard it
|
||||
log.debug(util.c("discarding PLC SCADA_MGMT packet without a known session from computer ", src_addr))
|
||||
end
|
||||
if protocol == PROTOCOL.RPLC then
|
||||
---@cast packet rplc_frame
|
||||
-- reactor PLC packet
|
||||
if session ~= nil then
|
||||
-- pass the packet onto the session handler
|
||||
session.in_queue.push_packet(packet)
|
||||
else
|
||||
log.debug(util.c("illegal packet type ", protocol, " on PLC channel"))
|
||||
-- any other packet should be session related, discard it
|
||||
log.debug("discarding RPLC packet without a known session")
|
||||
end
|
||||
elseif r_chan == config.RTU_Channel then
|
||||
-- look for an associated session
|
||||
local session = svsessions.find_rtu_session(src_addr)
|
||||
elseif protocol == PROTOCOL.SCADA_MGMT then
|
||||
---@cast packet mgmt_frame
|
||||
-- SCADA management packet
|
||||
if session ~= nil then
|
||||
-- pass the packet onto the session handler
|
||||
session.in_queue.push_packet(packet)
|
||||
elseif packet.type == MGMT_TYPE.ESTABLISH then
|
||||
-- establish a new session
|
||||
local last_ack = self.last_est_acks[src_addr]
|
||||
|
||||
if protocol == PROTOCOL.MODBUS_TCP then
|
||||
---@cast packet modbus_frame
|
||||
-- MODBUS response
|
||||
if session ~= nil then
|
||||
-- pass the packet onto the session handler
|
||||
session.in_queue.push_packet(packet)
|
||||
else
|
||||
-- any other packet should be session related, discard it
|
||||
log.debug("discarding MODBUS_TCP packet without a known session")
|
||||
end
|
||||
elseif protocol == PROTOCOL.SCADA_MGMT then
|
||||
---@cast packet mgmt_frame
|
||||
-- SCADA management packet
|
||||
if session ~= nil then
|
||||
-- pass the packet onto the session handler
|
||||
session.in_queue.push_packet(packet)
|
||||
elseif packet.type == MGMT_TYPE.ESTABLISH then
|
||||
-- establish a new session
|
||||
local last_ack = self.last_est_acks[src_addr]
|
||||
-- validate packet and continue
|
||||
if packet.length >= 3 and type(packet.data[1]) == "string" and type(packet.data[2]) == "string" then
|
||||
local comms_v = packet.data[1]
|
||||
local firmware_v = packet.data[2]
|
||||
local dev_type = packet.data[3]
|
||||
|
||||
-- validate packet and continue
|
||||
if packet.length >= 3 and type(packet.data[1]) == "string" and type(packet.data[2]) == "string" then
|
||||
local comms_v = packet.data[1]
|
||||
local firmware_v = packet.data[2]
|
||||
local dev_type = packet.data[3]
|
||||
|
||||
if comms_v ~= comms.version then
|
||||
if last_ack ~= ESTABLISH_ACK.BAD_VERSION then
|
||||
log.info(util.c("dropping RTU establish packet with incorrect comms version v", comms_v, " (expected v", comms.version, ")"))
|
||||
end
|
||||
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.BAD_VERSION)
|
||||
elseif dev_type == DEVICE_TYPE.RTU then
|
||||
if packet.length == 4 then
|
||||
-- this is an RTU advertisement for a new session
|
||||
local rtu_advert = packet.data[4]
|
||||
local s_id = svsessions.establish_rtu_session(src_addr, rtu_advert, firmware_v)
|
||||
|
||||
println(util.c("RTU (", firmware_v, ") [@", src_addr, "] \xbb connected"))
|
||||
log.info(util.c("RTU_ESTABLISH: RTU (",firmware_v, ") [@", src_addr, "] connected with session ID ", s_id))
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.ALLOW)
|
||||
else
|
||||
log.debug("RTU_ESTABLISH: packet length mismatch")
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
|
||||
end
|
||||
else
|
||||
log.debug(util.c("illegal establish packet for device ", dev_type, " on RTU channel"))
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
|
||||
if comms_v ~= comms.version then
|
||||
if last_ack ~= ESTABLISH_ACK.BAD_VERSION then
|
||||
log.info(util.c("dropping PLC establish packet with incorrect comms version v", comms_v, " (expected v", comms.version, ")"))
|
||||
end
|
||||
else
|
||||
log.debug("invalid establish packet (on RTU channel)")
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
|
||||
end
|
||||
else
|
||||
-- any other packet should be session related, discard it
|
||||
log.debug(util.c("discarding RTU SCADA_MGMT packet without a known session from computer ", src_addr))
|
||||
end
|
||||
else
|
||||
log.debug(util.c("illegal packet type ", protocol, " on RTU channel"))
|
||||
end
|
||||
elseif r_chan == config.CRD_Channel then
|
||||
-- look for an associated session
|
||||
local session = svsessions.find_crd_session(src_addr)
|
||||
|
||||
if protocol == PROTOCOL.SCADA_MGMT then
|
||||
---@cast packet mgmt_frame
|
||||
-- SCADA management packet
|
||||
if session ~= nil then
|
||||
-- pass the packet onto the session handler
|
||||
session.in_queue.push_packet(packet)
|
||||
elseif packet.type == MGMT_TYPE.ESTABLISH then
|
||||
-- establish a new session
|
||||
local last_ack = self.last_est_acks[src_addr]
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.BAD_VERSION)
|
||||
elseif dev_type == DEVICE_TYPE.PLC then
|
||||
-- PLC linking request
|
||||
if packet.length == 4 and type(packet.data[4]) == "number" then
|
||||
local reactor_id = packet.data[4]
|
||||
local plc_id = svsessions.establish_plc_session(src_addr, i_seq_num, reactor_id, firmware_v)
|
||||
|
||||
-- validate packet and continue
|
||||
if packet.length >= 3 and type(packet.data[1]) == "string" and type(packet.data[2]) == "string" then
|
||||
local comms_v = packet.data[1]
|
||||
local firmware_v = packet.data[2]
|
||||
local dev_type = packet.data[3]
|
||||
|
||||
if comms_v ~= comms.version then
|
||||
if last_ack ~= ESTABLISH_ACK.BAD_VERSION then
|
||||
log.info(util.c("dropping coordinator establish packet with incorrect comms version v", comms_v, " (expected v", comms.version, ")"))
|
||||
end
|
||||
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.BAD_VERSION)
|
||||
elseif dev_type == DEVICE_TYPE.CRD then
|
||||
-- this is an attempt to establish a new coordinator session
|
||||
local s_id = svsessions.establish_crd_session(src_addr, firmware_v)
|
||||
|
||||
if s_id ~= false then
|
||||
println(util.c("CRD (", firmware_v, ") [@", src_addr, "] \xbb connected"))
|
||||
log.info(util.c("CRD_ESTABLISH: coordinator (", firmware_v, ") [@", src_addr, "] connected with session ID ", s_id))
|
||||
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.ALLOW, { config.UnitCount, cooling_conf })
|
||||
else
|
||||
if plc_id == false then
|
||||
-- reactor already has a PLC assigned
|
||||
if last_ack ~= ESTABLISH_ACK.COLLISION then
|
||||
log.info("CRD_ESTABLISH: denied new coordinator [@" .. src_addr .. "] due to already being connected to another coordinator")
|
||||
log.warning(util.c("PLC_ESTABLISH: assignment collision with reactor ", reactor_id))
|
||||
end
|
||||
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.COLLISION)
|
||||
else
|
||||
-- got an ID; assigned to a reactor successfully
|
||||
println(util.c("PLC (", firmware_v, ") [@", src_addr, "] \xbb reactor ", reactor_id, " connected"))
|
||||
log.info(util.c("PLC_ESTABLISH: PLC (", firmware_v, ") [@", src_addr, "] reactor unit ", reactor_id, " PLC connected with session ID ", plc_id))
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.ALLOW)
|
||||
end
|
||||
else
|
||||
log.debug(util.c("illegal establish packet for device ", dev_type, " on coordinator channel"))
|
||||
log.debug("PLC_ESTABLISH: packet length mismatch/bad parameter type")
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
|
||||
end
|
||||
else
|
||||
log.debug("CRD_ESTABLISH: establish packet length mismatch")
|
||||
log.debug(util.c("illegal establish packet for device ", dev_type, " on PLC channel"))
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
|
||||
end
|
||||
else
|
||||
-- any other packet should be session related, discard it
|
||||
log.debug(util.c("discarding coordinator SCADA_MGMT packet without a known session from computer ", src_addr))
|
||||
end
|
||||
elseif protocol == PROTOCOL.SCADA_CRDN then
|
||||
---@cast packet crdn_frame
|
||||
-- coordinator packet
|
||||
if session ~= nil then
|
||||
-- pass the packet onto the session handler
|
||||
session.in_queue.push_packet(packet)
|
||||
else
|
||||
-- any other packet should be session related, discard it
|
||||
log.debug(util.c("discarding coordinator SCADA_CRDN packet without a known session from computer ", src_addr))
|
||||
log.debug("invalid establish packet (on PLC channel)")
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
|
||||
end
|
||||
else
|
||||
log.debug(util.c("illegal packet type ", protocol, " on coordinator channel"))
|
||||
end
|
||||
elseif r_chan == config.PKT_Channel then
|
||||
-- look for an associated session
|
||||
local session = svsessions.find_pdg_session(src_addr)
|
||||
|
||||
if protocol == PROTOCOL.SCADA_MGMT then
|
||||
---@cast packet mgmt_frame
|
||||
-- SCADA management packet
|
||||
if session ~= nil then
|
||||
-- pass the packet onto the session handler
|
||||
session.in_queue.push_packet(packet)
|
||||
elseif packet.type == MGMT_TYPE.ESTABLISH then
|
||||
-- establish a new session
|
||||
local last_ack = self.last_est_acks[src_addr]
|
||||
|
||||
-- validate packet and continue
|
||||
if packet.length >= 3 and type(packet.data[1]) == "string" and type(packet.data[2]) == "string" then
|
||||
local comms_v = packet.data[1]
|
||||
local firmware_v = packet.data[2]
|
||||
local dev_type = packet.data[3]
|
||||
|
||||
if comms_v ~= comms.version then
|
||||
if last_ack ~= ESTABLISH_ACK.BAD_VERSION then
|
||||
log.info(util.c("dropping PDG establish packet with incorrect comms version v", comms_v, " (expected v", comms.version, ")"))
|
||||
end
|
||||
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.BAD_VERSION)
|
||||
elseif dev_type == DEVICE_TYPE.PKT then
|
||||
-- this is an attempt to establish a new pocket diagnostic session
|
||||
local s_id = svsessions.establish_pdg_session(src_addr, firmware_v)
|
||||
|
||||
println(util.c("PKT (", firmware_v, ") [@", src_addr, "] \xbb connected"))
|
||||
log.info(util.c("PDG_ESTABLISH: pocket (", firmware_v, ") [@", src_addr, "] connected with session ID ", s_id))
|
||||
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.ALLOW)
|
||||
else
|
||||
log.debug(util.c("illegal establish packet for device ", dev_type, " on pocket channel"))
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
|
||||
end
|
||||
else
|
||||
log.debug("PDG_ESTABLISH: establish packet length mismatch")
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
|
||||
end
|
||||
else
|
||||
-- any other packet should be session related, discard it
|
||||
log.debug(util.c("discarding pocket SCADA_MGMT packet without a known session from computer ", src_addr))
|
||||
end
|
||||
elseif protocol == PROTOCOL.SCADA_CRDN then
|
||||
---@cast packet crdn_frame
|
||||
-- coordinator packet
|
||||
if session ~= nil then
|
||||
-- pass the packet onto the session handler
|
||||
session.in_queue.push_packet(packet)
|
||||
else
|
||||
-- any other packet should be session related, discard it
|
||||
log.debug(util.c("discarding pocket SCADA_CRDN packet without a known session from computer ", src_addr))
|
||||
end
|
||||
else
|
||||
log.debug(util.c("illegal packet type ", protocol, " on pocket channel"))
|
||||
-- any other packet should be session related, discard it
|
||||
log.debug(util.c("discarding PLC SCADA_MGMT packet without a known session from computer ", src_addr))
|
||||
end
|
||||
else
|
||||
log.debug("received packet for unknown channel " .. r_chan, true)
|
||||
log.debug(util.c("illegal packet type ", protocol, " on PLC channel"))
|
||||
end
|
||||
elseif r_chan == config.RTU_Channel then
|
||||
-- look for an associated session
|
||||
local session = svsessions.find_rtu_session(src_addr)
|
||||
|
||||
if protocol == PROTOCOL.MODBUS_TCP then
|
||||
---@cast packet modbus_frame
|
||||
-- MODBUS response
|
||||
if session ~= nil then
|
||||
-- pass the packet onto the session handler
|
||||
session.in_queue.push_packet(packet)
|
||||
else
|
||||
-- any other packet should be session related, discard it
|
||||
log.debug("discarding MODBUS_TCP packet without a known session")
|
||||
end
|
||||
elseif protocol == PROTOCOL.SCADA_MGMT then
|
||||
---@cast packet mgmt_frame
|
||||
-- SCADA management packet
|
||||
if session ~= nil then
|
||||
-- pass the packet onto the session handler
|
||||
session.in_queue.push_packet(packet)
|
||||
elseif packet.type == MGMT_TYPE.ESTABLISH then
|
||||
-- establish a new session
|
||||
local last_ack = self.last_est_acks[src_addr]
|
||||
|
||||
-- validate packet and continue
|
||||
if packet.length >= 3 and type(packet.data[1]) == "string" and type(packet.data[2]) == "string" then
|
||||
local comms_v = packet.data[1]
|
||||
local firmware_v = packet.data[2]
|
||||
local dev_type = packet.data[3]
|
||||
|
||||
if comms_v ~= comms.version then
|
||||
if last_ack ~= ESTABLISH_ACK.BAD_VERSION then
|
||||
log.info(util.c("dropping RTU establish packet with incorrect comms version v", comms_v, " (expected v", comms.version, ")"))
|
||||
end
|
||||
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.BAD_VERSION)
|
||||
elseif dev_type == DEVICE_TYPE.RTU then
|
||||
if packet.length == 4 then
|
||||
-- this is an RTU advertisement for a new session
|
||||
local rtu_advert = packet.data[4]
|
||||
local s_id = svsessions.establish_rtu_session(src_addr, i_seq_num, rtu_advert, firmware_v)
|
||||
|
||||
println(util.c("RTU (", firmware_v, ") [@", src_addr, "] \xbb connected"))
|
||||
log.info(util.c("RTU_ESTABLISH: RTU (",firmware_v, ") [@", src_addr, "] connected with session ID ", s_id))
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.ALLOW)
|
||||
else
|
||||
log.debug("RTU_ESTABLISH: packet length mismatch")
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
|
||||
end
|
||||
else
|
||||
log.debug(util.c("illegal establish packet for device ", dev_type, " on RTU channel"))
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
|
||||
end
|
||||
else
|
||||
log.debug("invalid establish packet (on RTU channel)")
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
|
||||
end
|
||||
else
|
||||
-- any other packet should be session related, discard it
|
||||
log.debug(util.c("discarding RTU SCADA_MGMT packet without a known session from computer ", src_addr))
|
||||
end
|
||||
else
|
||||
log.debug(util.c("illegal packet type ", protocol, " on RTU channel"))
|
||||
end
|
||||
elseif r_chan == config.CRD_Channel then
|
||||
-- look for an associated session
|
||||
local session = svsessions.find_crd_session(src_addr)
|
||||
|
||||
if protocol == PROTOCOL.SCADA_MGMT then
|
||||
---@cast packet mgmt_frame
|
||||
-- SCADA management packet
|
||||
if session ~= nil then
|
||||
-- pass the packet onto the session handler
|
||||
session.in_queue.push_packet(packet)
|
||||
elseif packet.type == MGMT_TYPE.ESTABLISH then
|
||||
-- establish a new session
|
||||
local last_ack = self.last_est_acks[src_addr]
|
||||
|
||||
-- validate packet and continue
|
||||
if packet.length >= 3 and type(packet.data[1]) == "string" and type(packet.data[2]) == "string" then
|
||||
local comms_v = packet.data[1]
|
||||
local firmware_v = packet.data[2]
|
||||
local dev_type = packet.data[3]
|
||||
|
||||
if comms_v ~= comms.version then
|
||||
if last_ack ~= ESTABLISH_ACK.BAD_VERSION then
|
||||
log.info(util.c("dropping coordinator establish packet with incorrect comms version v", comms_v, " (expected v", comms.version, ")"))
|
||||
end
|
||||
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.BAD_VERSION)
|
||||
elseif dev_type == DEVICE_TYPE.CRD then
|
||||
-- this is an attempt to establish a new coordinator session
|
||||
local s_id = svsessions.establish_crd_session(src_addr, i_seq_num, firmware_v)
|
||||
|
||||
if s_id ~= false then
|
||||
println(util.c("CRD (", firmware_v, ") [@", src_addr, "] \xbb connected"))
|
||||
log.info(util.c("CRD_ESTABLISH: coordinator (", firmware_v, ") [@", src_addr, "] connected with session ID ", s_id))
|
||||
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.ALLOW, { config.UnitCount, cooling_conf })
|
||||
else
|
||||
if last_ack ~= ESTABLISH_ACK.COLLISION then
|
||||
log.info("CRD_ESTABLISH: denied new coordinator [@" .. src_addr .. "] due to already being connected to another coordinator")
|
||||
end
|
||||
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.COLLISION)
|
||||
end
|
||||
else
|
||||
log.debug(util.c("illegal establish packet for device ", dev_type, " on coordinator channel"))
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
|
||||
end
|
||||
else
|
||||
log.debug("CRD_ESTABLISH: establish packet length mismatch")
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
|
||||
end
|
||||
else
|
||||
-- any other packet should be session related, discard it
|
||||
log.debug(util.c("discarding coordinator SCADA_MGMT packet without a known session from computer ", src_addr))
|
||||
end
|
||||
elseif protocol == PROTOCOL.SCADA_CRDN then
|
||||
---@cast packet crdn_frame
|
||||
-- coordinator packet
|
||||
if session ~= nil then
|
||||
-- pass the packet onto the session handler
|
||||
session.in_queue.push_packet(packet)
|
||||
else
|
||||
-- any other packet should be session related, discard it
|
||||
log.debug(util.c("discarding coordinator SCADA_CRDN packet without a known session from computer ", src_addr))
|
||||
end
|
||||
else
|
||||
log.debug(util.c("illegal packet type ", protocol, " on coordinator channel"))
|
||||
end
|
||||
elseif r_chan == config.PKT_Channel then
|
||||
-- look for an associated session
|
||||
local session = svsessions.find_pdg_session(src_addr)
|
||||
|
||||
if protocol == PROTOCOL.SCADA_MGMT then
|
||||
---@cast packet mgmt_frame
|
||||
-- SCADA management packet
|
||||
if session ~= nil then
|
||||
-- pass the packet onto the session handler
|
||||
session.in_queue.push_packet(packet)
|
||||
elseif packet.type == MGMT_TYPE.ESTABLISH then
|
||||
-- establish a new session
|
||||
local last_ack = self.last_est_acks[src_addr]
|
||||
|
||||
-- validate packet and continue
|
||||
if packet.length >= 3 and type(packet.data[1]) == "string" and type(packet.data[2]) == "string" then
|
||||
local comms_v = packet.data[1]
|
||||
local firmware_v = packet.data[2]
|
||||
local dev_type = packet.data[3]
|
||||
|
||||
if comms_v ~= comms.version then
|
||||
if last_ack ~= ESTABLISH_ACK.BAD_VERSION then
|
||||
log.info(util.c("dropping PDG establish packet with incorrect comms version v", comms_v, " (expected v", comms.version, ")"))
|
||||
end
|
||||
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.BAD_VERSION)
|
||||
elseif dev_type == DEVICE_TYPE.PKT then
|
||||
-- this is an attempt to establish a new pocket diagnostic session
|
||||
local s_id = svsessions.establish_pdg_session(src_addr, i_seq_num, firmware_v)
|
||||
|
||||
println(util.c("PKT (", firmware_v, ") [@", src_addr, "] \xbb connected"))
|
||||
log.info(util.c("PDG_ESTABLISH: pocket (", firmware_v, ") [@", src_addr, "] connected with session ID ", s_id))
|
||||
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.ALLOW)
|
||||
else
|
||||
log.debug(util.c("illegal establish packet for device ", dev_type, " on pocket channel"))
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
|
||||
end
|
||||
else
|
||||
log.debug("PDG_ESTABLISH: establish packet length mismatch")
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
|
||||
end
|
||||
else
|
||||
-- any other packet should be session related, discard it
|
||||
log.debug(util.c("discarding pocket SCADA_MGMT packet without a known session from computer ", src_addr))
|
||||
end
|
||||
elseif protocol == PROTOCOL.SCADA_CRDN then
|
||||
---@cast packet crdn_frame
|
||||
-- coordinator packet
|
||||
if session ~= nil then
|
||||
-- pass the packet onto the session handler
|
||||
session.in_queue.push_packet(packet)
|
||||
else
|
||||
-- any other packet should be session related, discard it
|
||||
log.debug(util.c("discarding pocket SCADA_CRDN packet without a known session from computer ", src_addr))
|
||||
end
|
||||
else
|
||||
log.debug(util.c("illegal packet type ", protocol, " on pocket channel"))
|
||||
end
|
||||
else
|
||||
log.debug("received packet for unknown channel " .. r_chan, true)
|
||||
end
|
||||
end
|
||||
|
||||
|
||||
Reference in New Issue
Block a user