#10 #133 alarm system logic and display, change to comms to support alarm actions, get_x get_y to graphics elements, bugfixes to coord establish and rtu establish, flashing trilight and alarm light indicators
This commit is contained in:
@@ -4,9 +4,15 @@ local log = require("scada-common.log")
|
||||
|
||||
local unit = {}
|
||||
|
||||
local ALARM = types.ALARM
|
||||
local PRIO = types.ALARM_PRIORITY
|
||||
local ALARM_STATE = types.ALARM_STATE
|
||||
|
||||
local TRI_FAIL = types.TRI_FAIL
|
||||
local DUMPING_MODE = types.DUMPING_MODE
|
||||
|
||||
local FLOW_STABILITY_DELAY_MS = 15000
|
||||
|
||||
local DT_KEYS = {
|
||||
ReactorTemp = "RTP",
|
||||
ReactorFuel = "RFL",
|
||||
@@ -21,6 +27,32 @@ local DT_KEYS = {
|
||||
TurbinePower = "TPR"
|
||||
}
|
||||
|
||||
---@alias ALARM_INT_STATE integer
|
||||
local AISTATE = {
|
||||
INACTIVE = 0,
|
||||
TRIPPING = 1,
|
||||
TRIPPED = 2,
|
||||
ACKED = 3,
|
||||
RING_BACK = 4,
|
||||
RING_BACK_TRIPPING = 5
|
||||
}
|
||||
|
||||
local aistate_string = {
|
||||
"INACTIVE",
|
||||
"TRIPPING",
|
||||
"TRIPPED",
|
||||
"ACKED",
|
||||
"RING_BACK",
|
||||
"RING_BACK_TRIPPING"
|
||||
}
|
||||
|
||||
---@class alarm_def
|
||||
---@field state ALARM_INT_STATE internal alarm state
|
||||
---@field trip_time integer time (ms) when first tripped
|
||||
---@field hold_time integer time (s) to hold before tripping
|
||||
---@field id ALARM alarm ID
|
||||
---@field tier integer alarm urgency tier (0 = highest)
|
||||
|
||||
-- create a new reactor unit
|
||||
---@param for_reactor integer reactor unit number
|
||||
---@param num_boilers integer number of boilers expected
|
||||
@@ -30,12 +62,49 @@ function unit.new(for_reactor, num_boilers, num_turbines)
|
||||
r_id = for_reactor,
|
||||
plc_s = nil, ---@class plc_session_struct
|
||||
plc_i = nil, ---@class plc_session
|
||||
counts = { boilers = num_boilers, turbines = num_turbines },
|
||||
turbines = {},
|
||||
boilers = {},
|
||||
redstone = {},
|
||||
deltas = {},
|
||||
last_heartbeat = 0,
|
||||
-- logic for alarms
|
||||
had_reactor = false,
|
||||
start_time = 0,
|
||||
plc_cache = {
|
||||
ok = false,
|
||||
rps_trip = false,
|
||||
rps_status = {}, ---@type rps_status
|
||||
damage = 0,
|
||||
temp = 0,
|
||||
waste = 0
|
||||
},
|
||||
---@class alarm_monitors
|
||||
alarms = {
|
||||
-- reactor lost under the condition of meltdown imminent
|
||||
ContainmentBreach = { state = AISTATE.INACTIVE, trip_time = 0, hold_time = 0, id = ALARM.ContainmentBreach, tier = PRIO.CRITICAL },
|
||||
-- radiation monitor alarm for this unit
|
||||
ContainmentRadiation = { state = AISTATE.INACTIVE, trip_time = 0, hold_time = 0, id = ALARM.ContainmentRadiation, tier = PRIO.CRITICAL },
|
||||
-- reactor offline after being online
|
||||
ReactorLost = { state = AISTATE.INACTIVE, trip_time = 0, hold_time = 0, id = ALARM.ReactorLost, tier = PRIO.URGENT },
|
||||
-- damage >100%
|
||||
CriticalDamage = { state = AISTATE.INACTIVE, trip_time = 0, hold_time = 0, id = ALARM.CriticalDamage, tier = PRIO.CRITICAL },
|
||||
-- reactor damage increasing
|
||||
ReactorDamage = { state = AISTATE.INACTIVE, trip_time = 0, hold_time = 0, id = ALARM.ReactorDamage, tier = PRIO.EMERGENCY },
|
||||
-- reactor >1200K
|
||||
ReactorOverTemp = { state = AISTATE.INACTIVE, trip_time = 0, hold_time = 0, id = ALARM.ReactorOverTemp, tier = PRIO.URGENT },
|
||||
-- reactor >1100K
|
||||
ReactorHighTemp = { state = AISTATE.INACTIVE, trip_time = 0, hold_time = 2, id = ALARM.ReactorHighTemp, tier = PRIO.TIMELY },
|
||||
-- waste = 100%
|
||||
ReactorWasteLeak = { state = AISTATE.INACTIVE, trip_time = 0, hold_time = 0, id = ALARM.ReactorWasteLeak, tier = PRIO.EMERGENCY },
|
||||
-- waste >85%
|
||||
ReactorHighWaste = { state = AISTATE.INACTIVE, trip_time = 0, hold_time = 2, id = ALARM.ReactorHighWaste, tier = PRIO.TIMELY },
|
||||
-- RPS trip occured
|
||||
RPSTransient = { state = AISTATE.INACTIVE, trip_time = 0, hold_time = 0, id = ALARM.RPSTransient, tier = PRIO.URGENT },
|
||||
-- BoilRateMismatch, CoolantFeedMismatch, SteamFeedMismatch, MaxWaterReturnFeed
|
||||
RCSTransient = { state = AISTATE.INACTIVE, trip_time = 0, hold_time = 5, id = ALARM.RCSTransient, tier = PRIO.TIMELY },
|
||||
-- "It's just a routine turbin' trip!" -Bill Gibson
|
||||
TurbineTrip = { state = AISTATE.INACTIVE, trip_time = 0, hold_time = 0, id = ALARM.TurbineTrip, tier = PRIO.URGENT }
|
||||
},
|
||||
db = {
|
||||
---@class annunciator
|
||||
annunciator = {
|
||||
@@ -47,6 +116,7 @@ function unit.new(for_reactor, num_boilers, num_turbines)
|
||||
AutoReactorSCRAM = false,
|
||||
RCPTrip = false,
|
||||
RCSFlowLow = false,
|
||||
CoolantLevelLow = false,
|
||||
ReactorTempHigh = false,
|
||||
ReactorHighDeltaT = false,
|
||||
FuelInputRateLow = false,
|
||||
@@ -55,6 +125,7 @@ function unit.new(for_reactor, num_boilers, num_turbines)
|
||||
-- boiler
|
||||
BoilerOnline = {},
|
||||
HeatingRateLow = {},
|
||||
WaterLevelLow = {},
|
||||
BoilRateMismatch = false,
|
||||
CoolantFeedMismatch = false,
|
||||
-- turbine
|
||||
@@ -64,6 +135,21 @@ function unit.new(for_reactor, num_boilers, num_turbines)
|
||||
SteamDumpOpen = {},
|
||||
TurbineOverSpeed = {},
|
||||
TurbineTrip = {}
|
||||
},
|
||||
---@class alarms
|
||||
alarm_states = {
|
||||
ALARM_STATE.INACTIVE,
|
||||
ALARM_STATE.INACTIVE,
|
||||
ALARM_STATE.INACTIVE,
|
||||
ALARM_STATE.INACTIVE,
|
||||
ALARM_STATE.INACTIVE,
|
||||
ALARM_STATE.INACTIVE,
|
||||
ALARM_STATE.INACTIVE,
|
||||
ALARM_STATE.INACTIVE,
|
||||
ALARM_STATE.INACTIVE,
|
||||
ALARM_STATE.INACTIVE,
|
||||
ALARM_STATE.INACTIVE,
|
||||
ALARM_STATE.INACTIVE
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -125,6 +211,92 @@ function unit.new(for_reactor, num_boilers, num_turbines)
|
||||
end
|
||||
end
|
||||
|
||||
-- update an alarm state given conditions
|
||||
---@param tripped boolean if the alarm condition is still active
|
||||
---@param alarm alarm_def alarm table
|
||||
local function _update_alarm_state(tripped, alarm)
|
||||
local int_state = alarm.state
|
||||
local ext_state = self.db.alarm_states[alarm.id]
|
||||
|
||||
-- alarm inactive
|
||||
if int_state == AISTATE.INACTIVE then
|
||||
if tripped then
|
||||
alarm.trip_time = util.time_ms()
|
||||
if alarm.hold_time > 0 then
|
||||
alarm.state = AISTATE.TRIPPING
|
||||
self.db.alarm_states[alarm.id] = ALARM_STATE.INACTIVE
|
||||
else
|
||||
alarm.state = AISTATE.TRIPPED
|
||||
self.db.alarm_states[alarm.id] = ALARM_STATE.TRIPPED
|
||||
log.info(util.c("UNIT ", self.r_id, " ALARM ", alarm.id, " (", types.alarm_string[alarm.id], "): TRIPPED [PRIORITY ",
|
||||
types.alarm_prio_string[alarm.tier + 1],"]"))
|
||||
end
|
||||
else
|
||||
alarm.trip_time = util.time_ms()
|
||||
self.db.alarm_states[alarm.id] = ALARM_STATE.INACTIVE
|
||||
end
|
||||
-- alarm condition met, but not yet for required hold time
|
||||
elseif (int_state == AISTATE.TRIPPING) or (int_state == AISTATE.RING_BACK_TRIPPING) then
|
||||
if tripped then
|
||||
local elapsed = util.time_ms() - alarm.trip_time
|
||||
if elapsed > (alarm.hold_time * 1000) then
|
||||
alarm.state = AISTATE.TRIPPED
|
||||
self.db.alarm_states[alarm.id] = ALARM_STATE.TRIPPED
|
||||
log.info(util.c("UNIT ", self.r_id, " ALARM ", alarm.id, " (", types.alarm_string[alarm.id], "): TRIPPED [PRIORITY ",
|
||||
types.alarm_prio_string[alarm.tier + 1],"]"))
|
||||
end
|
||||
elseif int_state == AISTATE.RING_BACK_TRIPPING then
|
||||
alarm.trip_time = 0
|
||||
alarm.state = AISTATE.RING_BACK
|
||||
self.db.alarm_states[alarm.id] = ALARM_STATE.RING_BACK
|
||||
else
|
||||
alarm.trip_time = 0
|
||||
alarm.state = AISTATE.INACTIVE
|
||||
self.db.alarm_states[alarm.id] = ALARM_STATE.INACTIVE
|
||||
end
|
||||
-- alarm tripped and alarming
|
||||
elseif int_state == AISTATE.TRIPPED then
|
||||
if tripped then
|
||||
if ext_state == ALARM_STATE.ACKED then
|
||||
-- was acked by coordinator
|
||||
alarm.state = AISTATE.ACKED
|
||||
end
|
||||
else
|
||||
alarm.state = AISTATE.RING_BACK
|
||||
self.db.alarm_states[alarm.id] = ALARM_STATE.RING_BACK
|
||||
end
|
||||
-- alarm acknowledged but still tripped
|
||||
elseif int_state == AISTATE.ACKED then
|
||||
if not tripped then
|
||||
alarm.state = AISTATE.RING_BACK
|
||||
self.db.alarm_states[alarm.id] = ALARM_STATE.RING_BACK
|
||||
end
|
||||
-- alarm no longer tripped, operator must reset to clear
|
||||
elseif int_state == AISTATE.RING_BACK then
|
||||
if tripped then
|
||||
alarm.trip_time = util.time_ms()
|
||||
if alarm.hold_time > 0 then
|
||||
alarm.state = AISTATE.RING_BACK_TRIPPING
|
||||
else
|
||||
alarm.state = AISTATE.TRIPPED
|
||||
self.db.alarm_states[alarm.id] = ALARM_STATE.TRIPPED
|
||||
end
|
||||
elseif ext_state == ALARM_STATE.INACTIVE then
|
||||
-- was reset by coordinator
|
||||
alarm.state = AISTATE.INACTIVE
|
||||
alarm.trip_time = 0
|
||||
end
|
||||
else
|
||||
log.error(util.c("invalid alarm state for unit ", self.r_id, " alarm ", alarm.id), true)
|
||||
end
|
||||
|
||||
-- check for state change
|
||||
if alarm.state ~= int_state then
|
||||
local change_str = util.c(aistate_string[int_state + 1], " -> ", aistate_string[alarm.state + 1])
|
||||
log.debug(util.c("UNIT ", self.r_id, " ALARM ", alarm.id, " (", types.alarm_string[alarm.id], "): ", change_str))
|
||||
end
|
||||
end
|
||||
|
||||
-- update all delta computations
|
||||
local function _dt__compute_all()
|
||||
if self.plc_s ~= nil then
|
||||
@@ -181,6 +353,21 @@ function unit.new(for_reactor, num_boilers, num_turbines)
|
||||
if self.plc_s ~= nil then
|
||||
local plc_db = self.plc_i.get_db()
|
||||
|
||||
-- record reactor start time (some alarms are delayed during reactor heatup)
|
||||
if self.start_time == 0 and plc_db.mek_status.status then
|
||||
self.start_time = util.time_ms()
|
||||
elseif not plc_db.mek_status.status then
|
||||
self.start_time = 0
|
||||
end
|
||||
|
||||
-- record reactor stats
|
||||
self.plc_cache.ok = not (plc_db.rps_status.fault or plc_db.rps_status.sys_fail or plc_db.rps_status.force_dis)
|
||||
self.plc_cache.rps_trip = plc_db.rps_tripped
|
||||
self.plc_cache.rps_status = plc_db.rps_status
|
||||
self.plc_cache.damage = plc_db.mek_status.damage
|
||||
self.plc_cache.temp = plc_db.mek_status.temp
|
||||
self.plc_cache.waste = plc_db.mek_status.waste_fill
|
||||
|
||||
-- heartbeat blink about every second
|
||||
if self.last_heartbeat + 1000 < plc_db.last_status_update then
|
||||
self.db.annunciator.PLCHeartbeat = not self.db.annunciator.PLCHeartbeat
|
||||
@@ -201,9 +388,11 @@ function unit.new(for_reactor, num_boilers, num_turbines)
|
||||
self.db.annunciator.HighStartupRate = not plc_db.mek_status.status and plc_db.mek_status.burn_rate > 40
|
||||
|
||||
-- if no boilers, use reactor heating rate to check for boil rate mismatch
|
||||
if self.counts.boilers == 0 then
|
||||
if num_boilers == 0 then
|
||||
total_boil_rate = plc_db.mek_status.heating_rate
|
||||
end
|
||||
else
|
||||
self.plc_cache.ok = false
|
||||
end
|
||||
|
||||
-------------
|
||||
@@ -211,13 +400,13 @@ function unit.new(for_reactor, num_boilers, num_turbines)
|
||||
-------------
|
||||
|
||||
-- clear boiler online flags
|
||||
for i = 1, self.counts.boilers do self.db.annunciator.BoilerOnline[i] = false end
|
||||
for i = 1, num_boilers do self.db.annunciator.BoilerOnline[i] = false end
|
||||
|
||||
-- aggregated statistics
|
||||
local boiler_steam_dt_sum = 0.0
|
||||
local boiler_water_dt_sum = 0.0
|
||||
|
||||
if self.counts.boilers > 0 then
|
||||
if num_boilers > 0 then
|
||||
-- go through boilers for stats and online
|
||||
for i = 1, #self.boilers do
|
||||
local session = self.boilers[i] ---@type unit_session
|
||||
@@ -259,7 +448,7 @@ function unit.new(for_reactor, num_boilers, num_turbines)
|
||||
-- check coolant feed mismatch if using boilers, otherwise calculate with reactor
|
||||
local cfmismatch = false
|
||||
|
||||
if self.counts.boilers > 0 then
|
||||
if num_boilers > 0 then
|
||||
for i = 1, #self.boilers do
|
||||
local boiler = self.boilers[i] ---@type unit_session
|
||||
local idx = boiler.get_device_idx()
|
||||
@@ -290,7 +479,7 @@ function unit.new(for_reactor, num_boilers, num_turbines)
|
||||
--------------
|
||||
|
||||
-- clear turbine online flags
|
||||
for i = 1, self.counts.turbines do self.db.annunciator.TurbineOnline[i] = false end
|
||||
for i = 1, num_turbines do self.db.annunciator.TurbineOnline[i] = false end
|
||||
|
||||
-- aggregated statistics
|
||||
local total_flow_rate = 0
|
||||
@@ -359,6 +548,75 @@ function unit.new(for_reactor, num_boilers, num_turbines)
|
||||
end
|
||||
end
|
||||
|
||||
-- evaluate alarm conditions
|
||||
local function _update_alarms()
|
||||
local annunc = self.db.annunciator
|
||||
local plc_cache = self.plc_cache
|
||||
|
||||
-- Containment Breach
|
||||
-- lost plc with critical damage (rip plc, you will be missed)
|
||||
_update_alarm_state((not plc_cache.ok) and (plc_cache.damage > 99), self.alarms.ContainmentBreach)
|
||||
|
||||
-- Containment Radiation
|
||||
---@todo containment radiation alarm
|
||||
_update_alarm_state(false, self.alarms.ContainmentRadiation)
|
||||
|
||||
-- Reactor Lost
|
||||
_update_alarm_state(self.had_reactor and self.plc_s == nil, self.alarms.ReactorLost)
|
||||
|
||||
-- Critical Damage
|
||||
_update_alarm_state(plc_cache.damage >= 100, self.alarms.CriticalDamage)
|
||||
|
||||
-- Reactor Damage
|
||||
_update_alarm_state(plc_cache.damage > 0, self.alarms.ReactorDamage)
|
||||
|
||||
-- Over-Temperature
|
||||
_update_alarm_state(plc_cache.temp >= 1200, self.alarms.ReactorOverTemp)
|
||||
|
||||
-- High Temperature
|
||||
_update_alarm_state(plc_cache.temp > 1150, self.alarms.ReactorHighTemp)
|
||||
|
||||
-- Waste Leak
|
||||
_update_alarm_state(plc_cache.waste >= 0.99, self.alarms.ReactorWasteLeak)
|
||||
|
||||
-- High Waste
|
||||
_update_alarm_state(plc_cache.waste > 0.50, self.alarms.ReactorHighWaste)
|
||||
|
||||
-- RPS Transient (excludes timeouts and manual trips)
|
||||
local rps_alarm = false
|
||||
if plc_cache.rps_status.manual ~= nil then
|
||||
if plc_cache.rps_trip then
|
||||
for key, val in pairs(plc_cache.rps_status) do
|
||||
if key ~= "manual" and key ~= "timeout" then
|
||||
rps_alarm = rps_alarm or val
|
||||
end
|
||||
end
|
||||
end
|
||||
end
|
||||
|
||||
_update_alarm_state(rps_alarm, self.alarms.RPSTransient)
|
||||
|
||||
-- RCS Transient
|
||||
local any_low = false
|
||||
local any_over = false
|
||||
for i = 1, #annunc.WaterLevelLow do any_low = any_low or annunc.WaterLevelLow[i] end
|
||||
for i = 1, #annunc.TurbineOverSpeed do any_over = any_over or annunc.TurbineOverSpeed[i] end
|
||||
|
||||
local rcs_trans = any_low or any_over or annunc.RCPTrip or annunc.RCSFlowLow or annunc.MaxWaterReturnFeed
|
||||
|
||||
-- flow is ramping up right after reactor start, annunciator indicators for these states may not indicate a real issue
|
||||
if util.time_ms() - self.start_time > FLOW_STABILITY_DELAY_MS then
|
||||
rcs_trans = rcs_trans or annunc.BoilRateMismatch or annunc.CoolantFeedMismatch or annunc.SteamFeedMismatch
|
||||
end
|
||||
|
||||
_update_alarm_state(rcs_trans, self.alarms.RCSTransient)
|
||||
|
||||
-- Turbine Trip
|
||||
local any_trip = false
|
||||
for i = 1, #annunc.TurbineTrip do any_trip = any_trip or annunc.TurbineTrip[i] end
|
||||
_update_alarm_state(any_trip, self.alarms.TurbineTrip)
|
||||
end
|
||||
|
||||
-- unlink disconnected units
|
||||
---@param sessions table
|
||||
local function _unlink_disconnected_units(sessions)
|
||||
@@ -372,6 +630,7 @@ function unit.new(for_reactor, num_boilers, num_turbines)
|
||||
-- link the PLC
|
||||
---@param plc_session plc_session_struct
|
||||
function public.link_plc_session(plc_session)
|
||||
self.had_reactor = true
|
||||
self.plc_s = plc_session
|
||||
self.plc_i = plc_session.instance
|
||||
|
||||
@@ -443,6 +702,7 @@ function unit.new(for_reactor, num_boilers, num_turbines)
|
||||
-- unlink PLC if session was closed
|
||||
if self.plc_s ~= nil and not self.plc_s.open then
|
||||
self.plc_s = nil
|
||||
self.plc_i = nil
|
||||
end
|
||||
|
||||
-- unlink RTU unit sessions if they are closed
|
||||
@@ -451,6 +711,36 @@ function unit.new(for_reactor, num_boilers, num_turbines)
|
||||
|
||||
-- update annunciator logic
|
||||
_update_annunciator()
|
||||
|
||||
-- update alarm status
|
||||
_update_alarms()
|
||||
end
|
||||
|
||||
-- ACK/RESET ALARMS --
|
||||
|
||||
-- acknowledge all alarms (if possible)
|
||||
function public.ack_all()
|
||||
for i = 1, #self.db.alarm_states do
|
||||
if self.db.alarm_states[i] == ALARM_STATE.TRIPPED then
|
||||
self.db.alarm_states[i] = ALARM_STATE.ACKED
|
||||
end
|
||||
end
|
||||
end
|
||||
|
||||
-- acknowledge an alarm (if possible)
|
||||
---@param id ALARM alarm ID
|
||||
function public.ack_alarm(id)
|
||||
if (type(id) == "number") and (self.db.alarm_states[id] == ALARM_STATE.TRIPPED) then
|
||||
self.db.alarm_states[id] = ALARM_STATE.ACKED
|
||||
end
|
||||
end
|
||||
|
||||
-- reset an alarm (if possible)
|
||||
---@param id ALARM alarm ID
|
||||
function public.reset_alarm(id)
|
||||
if (type(id) == "number") and (self.db.alarm_states[id] == ALARM_STATE.RING_BACK) then
|
||||
self.db.alarm_states[id] = ALARM_STATE.INACTIVE
|
||||
end
|
||||
end
|
||||
|
||||
-- READ STATES/PROPERTIES --
|
||||
@@ -526,6 +816,9 @@ function unit.new(for_reactor, num_boilers, num_turbines)
|
||||
-- get the annunciator status
|
||||
function public.get_annunciator() return self.db.annunciator end
|
||||
|
||||
-- get the alarm states
|
||||
function public.get_alarms() return self.db.alarm_states end
|
||||
|
||||
-- get the reactor ID
|
||||
function public.get_id() return self.r_id end
|
||||
|
||||
|
||||