@@ -710,6 +710,10 @@ local function config_view(display)
|
||||
tool_ctl.p_desc_ext.set_value("Before adding lots of SNAs: multiply the \"PEAK\" rate on the flow monitor (after connecting at least 1 SNA) by 10 to get the mB/t of waste that they can process. Enough SNAs to provide 2x to 3x of your max burn rate should be a good margin to catch up after night or cloudy weather. Too many devices (such as SNAs) on one RTU can cause lag.")
|
||||
elseif type == "dynamicValve" then
|
||||
tool_ctl.p_prompt.set_value("This is the # dynamic tank for...")
|
||||
tool_ctl.p_assign_btn.show()
|
||||
tool_ctl.p_assign_btn.redraw()
|
||||
tool_ctl.p_assign_end.show()
|
||||
tool_ctl.p_assign_end.redraw()
|
||||
tool_ctl.p_idx.show()
|
||||
tool_ctl.p_idx.redraw()
|
||||
tool_ctl.p_idx.set_max(4)
|
||||
@@ -724,23 +728,19 @@ local function config_view(display)
|
||||
tool_ctl.p_unit.enable()
|
||||
end
|
||||
|
||||
tool_ctl.p_assign_btn.show()
|
||||
tool_ctl.p_assign_btn.redraw()
|
||||
tool_ctl.p_assign_end.show()
|
||||
tool_ctl.p_assign_end.redraw()
|
||||
tool_ctl.p_desc.reposition(1, 8)
|
||||
tool_ctl.p_desc.set_value("Each reactor unit can have at most 1 tank and the facility can have at most 4. Each facility tank must have a unique # 1 through 4, regardless of where it is connected. Only a total of 4 tanks can be displayed on the flow monitor.")
|
||||
elseif type == "environmentDetector" then
|
||||
tool_ctl.p_prompt.set_value("This is the # environment detector for...")
|
||||
tool_ctl.p_assign_btn.show()
|
||||
tool_ctl.p_assign_btn.redraw()
|
||||
tool_ctl.p_assign_end.show()
|
||||
tool_ctl.p_assign_end.redraw()
|
||||
tool_ctl.p_idx.show()
|
||||
tool_ctl.p_idx.redraw()
|
||||
tool_ctl.p_idx.set_max(99)
|
||||
tool_ctl.p_unit.reposition(18, 6)
|
||||
if tool_ctl.p_assign_btn.get_value() == 1 then tool_ctl.p_unit.disable() else tool_ctl.p_unit.enable() end
|
||||
tool_ctl.p_assign_btn.show()
|
||||
tool_ctl.p_assign_btn.redraw()
|
||||
tool_ctl.p_assign_end.show()
|
||||
tool_ctl.p_assign_end.redraw()
|
||||
tool_ctl.p_desc.reposition(1, 8)
|
||||
tool_ctl.p_desc.set_value("You can connect more than one environment detector for a particular unit or the facility. In that case, the maximum radiation reading from those assigned to that particular unit or the facility will be used for alarms and display.")
|
||||
elseif type == "inductionPort" or type == "spsPort" then
|
||||
@@ -882,6 +882,8 @@ local function config_view(display)
|
||||
tool_ctl.p_err.show()
|
||||
return
|
||||
else index = idx end
|
||||
elseif peri_type == "dynamicValve" then
|
||||
index = 1
|
||||
elseif peri_type == "environmentDetector" then
|
||||
if not (util.is_int(idx) and idx > 0) then
|
||||
tool_ctl.p_err.set_value("Index must be greater than 0.")
|
||||
|
||||