#184 supervisor graphics updates for new system, added PLC and CRD pages on supervisor front panel
This commit is contained in:
@@ -6,39 +6,102 @@ local psil = require("scada-common.psil")
|
||||
|
||||
local databus = {}
|
||||
|
||||
-- databus PSIL
|
||||
databus.ps = psil.create()
|
||||
|
||||
local dbus_iface = {
|
||||
ps = psil.create(),
|
||||
session_entries = { rtu = {}, plc = {}, coord = {}, diag = {} }
|
||||
session_entries = { rtu = {}, diag = {} }
|
||||
}
|
||||
|
||||
-- call to toggle heartbeat signal
|
||||
function databus.heartbeat() dbus_iface.ps.toggle("heartbeat") end
|
||||
function databus.heartbeat() databus.ps.toggle("heartbeat") end
|
||||
|
||||
-- transmit firmware versions across the bus
|
||||
---@param plc_v string supervisor version
|
||||
---@param comms_v string comms version
|
||||
function databus.tx_versions(plc_v, comms_v)
|
||||
dbus_iface.ps.publish("version", plc_v)
|
||||
dbus_iface.ps.publish("comms_version", comms_v)
|
||||
databus.ps.publish("version", plc_v)
|
||||
databus.ps.publish("comms_version", comms_v)
|
||||
end
|
||||
|
||||
-- transmit hardware status for modem connection state
|
||||
---@param has_modem boolean
|
||||
function databus.tx_hw_modem(has_modem)
|
||||
dbus_iface.ps.publish("has_modem", has_modem)
|
||||
databus.ps.publish("has_modem", has_modem)
|
||||
end
|
||||
|
||||
function databus.tx_svs_connection(type, data)
|
||||
-- transmit PLC firmware version and session connection state
|
||||
---@param reactor_id integer reactor unit ID
|
||||
---@param fw string firmware version
|
||||
---@param channel integer PLC remote port
|
||||
function databus.tx_plc_connected(reactor_id, fw, channel)
|
||||
databus.ps.publish("plc_" .. reactor_id .. "_fw", fw)
|
||||
databus.ps.publish("plc_" .. reactor_id .. "_conn", true)
|
||||
databus.ps.publish("plc_" .. reactor_id .. "_chan", tostring(channel))
|
||||
end
|
||||
|
||||
function databus.tx_svs_disconnection(type, data)
|
||||
-- transmit PLC session connection state
|
||||
---@param reactor_id integer reactor unit ID
|
||||
function databus.tx_plc_disconnected(reactor_id)
|
||||
databus.ps.publish("plc_" .. reactor_id .. "_fw", " ------- ")
|
||||
databus.ps.publish("plc_" .. reactor_id .. "_conn", false)
|
||||
databus.ps.publish("plc_" .. reactor_id .. "_chan", " --- ")
|
||||
databus.ps.publish("plc_" .. reactor_id .. "_rtt", 0)
|
||||
databus.ps.publish("plc_" .. reactor_id .. "_rtt_color", colors.lightGray)
|
||||
end
|
||||
|
||||
-- transmit PLC session RTT
|
||||
---@param reactor_id integer reactor unit ID
|
||||
---@param rtt integer round trip time
|
||||
function databus.tx_plc_rtt(reactor_id, rtt)
|
||||
databus.ps.publish("plc_" .. reactor_id .. "_rtt", rtt)
|
||||
|
||||
if rtt > 700 then
|
||||
databus.ps.publish("plc_" .. reactor_id .. "_rtt_color", colors.red)
|
||||
elseif rtt > 300 then
|
||||
databus.ps.publish("plc_" .. reactor_id .. "_rtt_color", colors.yellow_hc)
|
||||
else
|
||||
databus.ps.publish("plc_" .. reactor_id .. "_rtt_color", colors.green)
|
||||
end
|
||||
end
|
||||
|
||||
-- transmit coordinator firmware version and session connection state
|
||||
---@param fw string firmware version
|
||||
---@param channel integer coordinator remote port
|
||||
function databus.tx_crd_connected(fw, channel)
|
||||
databus.ps.publish("crd_fw", fw)
|
||||
databus.ps.publish("crd_conn", true)
|
||||
databus.ps.publish("crd_chan", tostring(channel))
|
||||
end
|
||||
|
||||
-- transmit coordinator session connection state
|
||||
function databus.tx_crd_disconnected()
|
||||
databus.ps.publish("crd_fw", " ------- ")
|
||||
databus.ps.publish("crd_conn", false)
|
||||
databus.ps.publish("crd_chan", "---")
|
||||
databus.ps.publish("crd_rtt", 0)
|
||||
databus.ps.publish("crd_rtt_color", colors.lightGray)
|
||||
end
|
||||
|
||||
-- transmit coordinator session RTT
|
||||
---@param rtt integer round trip time
|
||||
function databus.tx_crd_rtt(rtt)
|
||||
databus.ps.publish("crd_rtt", rtt)
|
||||
|
||||
if rtt > 700 then
|
||||
databus.ps.publish("crd_rtt_color", colors.red)
|
||||
elseif rtt > 300 then
|
||||
databus.ps.publish("crd_rtt_color", colors.yellow_hc)
|
||||
else
|
||||
databus.ps.publish("crd_rtt_color", colors.green)
|
||||
end
|
||||
end
|
||||
|
||||
-- link a function to receive data from the bus
|
||||
---@param field string field name
|
||||
---@param func function function to link
|
||||
function databus.rx_field(field, func)
|
||||
dbus_iface.ps.subscribe(field, func)
|
||||
databus.ps.subscribe(field, func)
|
||||
end
|
||||
|
||||
return databus
|
||||
|
||||
Reference in New Issue