#362 taking max of connected radiation monitors
This commit is contained in:
@@ -121,6 +121,11 @@ local function handle_unit_mount(smem, println_ts, iface, type, device, unit)
|
||||
log.error(util.c("environment detector '", unit.name, "' cannot init, no valid assignment provided in config"))
|
||||
end
|
||||
|
||||
if (unit.index == false) or unit.index < 1 then
|
||||
invalid = true
|
||||
log.error(util.c("environment detector '", unit.name, "' cannot init, invalid index provided in config"))
|
||||
end
|
||||
|
||||
unit.type = RTU_UNIT_TYPE.ENV_DETECTOR
|
||||
else
|
||||
resend_advert = false
|
||||
|
||||
Reference in New Issue