#7 work on PLC session comms, bugfixes with comms, general supervisor bugfixes
This commit is contained in:
@@ -5,6 +5,7 @@
|
||||
|
||||
local PROTOCOLS = comms.PROTOCOLS
|
||||
local RPLC_TYPES = comms.RPLC_TYPES
|
||||
local RPLC_LINKING = comms.RPLC_LINKING
|
||||
local SCADA_MGMT_TYPES = comms.SCADA_MGMT_TYPES
|
||||
local RTU_ADVERT_TYPES = comms.RTU_ADVERT_TYPES
|
||||
|
||||
@@ -64,7 +65,7 @@ function superv_comms(num_reactors, modem, dev_listen, coord_listen)
|
||||
-- parse a packet
|
||||
local parse_packet = function(side, sender, reply_to, message, distance)
|
||||
local pkt = nil
|
||||
local s_pkt = scada_packet()
|
||||
local s_pkt = comms.scada_packet()
|
||||
|
||||
-- parse packet as generic SCADA packet
|
||||
s_pkt.receive(side, sender, reply_to, message, distance)
|
||||
@@ -104,21 +105,22 @@ function superv_comms(num_reactors, modem, dev_listen, coord_listen)
|
||||
|
||||
local handle_packet = function(packet)
|
||||
if packet ~= nil then
|
||||
local sender = packet.scada_frame.sender()
|
||||
local receiver = packet.scada_frame.receiver()
|
||||
local l_port = packet.scada_frame.local_port()
|
||||
local r_port = packet.scada_frame.remote_port()
|
||||
local protocol = packet.scada_frame.protocol()
|
||||
|
||||
-- device (RTU/PLC) listening channel
|
||||
if receiver == self.dev_listen then
|
||||
if l_port == self.dev_listen then
|
||||
if protocol == PROTOCOLS.MODBUS_TCP then
|
||||
-- MODBUS response
|
||||
elseif protocol == PROTOCOLS.RPLC then
|
||||
-- reactor PLC packet
|
||||
local session = svsessions.find_session(SESSION_TYPE.PLC_SESSION, sender)
|
||||
local session = svsessions.find_session(SESSION_TYPE.PLC_SESSION, r_port)
|
||||
if session then
|
||||
if packet.type == RPLC_TYPES.LINK_REQ then
|
||||
-- new device on this port? that's a collision
|
||||
_send_plc_linking(sender, { RPLC_LINKING.COLLISION })
|
||||
log._debug("PLC_LNK: request from existing connection received on " .. r_port .. ", responding with collision")
|
||||
_send_plc_linking(r_port, { RPLC_LINKING.COLLISION })
|
||||
else
|
||||
-- pass the packet onto the session handler
|
||||
session.in_queue.push_packet(packet)
|
||||
@@ -126,18 +128,25 @@ function superv_comms(num_reactors, modem, dev_listen, coord_listen)
|
||||
else
|
||||
-- unknown session, is this a linking request?
|
||||
if packet.type == RPLC_TYPES.LINK_REQ then
|
||||
-- this is a linking request
|
||||
local plc_id = svsessions.establish_plc_session(sender)
|
||||
if plc_id == false then
|
||||
-- reactor already has a PLC assigned
|
||||
_send_plc_linking(sender, { RPLC_LINKING.COLLISION })
|
||||
if packet.length == 1 then
|
||||
-- this is a linking request
|
||||
local plc_id = svsessions.establish_plc_session(l_port, r_port, packet.data[1])
|
||||
if plc_id == false then
|
||||
-- reactor already has a PLC assigned
|
||||
log._debug("PLC_LNK: assignment collision with reactor " .. packet.data[1])
|
||||
_send_plc_linking(r_port, { RPLC_LINKING.COLLISION })
|
||||
else
|
||||
-- got an ID; assigned to a reactor successfully
|
||||
log._debug("PLC_LNK: allowed for device at " .. r_port)
|
||||
_send_plc_linking(r_port, { RPLC_LINKING.ALLOW })
|
||||
end
|
||||
else
|
||||
-- got an ID; assigned to a reactor successfully
|
||||
_send_plc_linking(sender, { RPLC_LINKING.ALLOW })
|
||||
log._debug("PLC_LNK: new linking packet length mismatch")
|
||||
end
|
||||
else
|
||||
-- force a re-link
|
||||
_send_plc_linking(sender, { RPLC_LINKING.DENY })
|
||||
log._debug("PLC_LNK: no session but not a link, force relink")
|
||||
_send_plc_linking(r_port, { RPLC_LINKING.DENY })
|
||||
end
|
||||
end
|
||||
elseif protocol == PROTOCOLS.SCADA_MGMT then
|
||||
@@ -146,7 +155,7 @@ function superv_comms(num_reactors, modem, dev_listen, coord_listen)
|
||||
log._debug("illegal packet type " .. protocol .. " on device listening channel")
|
||||
end
|
||||
-- coordinator listening channel
|
||||
elseif receiver == self.coord_listen then
|
||||
elseif l_port == self.coord_listen then
|
||||
if protocol == PROTOCOLS.SCADA_MGMT then
|
||||
-- SCADA management packet
|
||||
elseif protocol == PROTOCOLS.COORD_DATA then
|
||||
@@ -155,7 +164,7 @@ function superv_comms(num_reactors, modem, dev_listen, coord_listen)
|
||||
log._debug("illegal packet type " .. protocol .. " on coordinator listening channel")
|
||||
end
|
||||
else
|
||||
log._error("received packet on unused channel " .. receiver, true)
|
||||
log._error("received packet on unused channel " .. l_port, true)
|
||||
end
|
||||
end
|
||||
end
|
||||
|
||||
Reference in New Issue
Block a user