#8 RTU session for emachine and turbine, RTU session creation, adjusted sequence number logic in svsessions
This commit is contained in:
@@ -26,7 +26,6 @@ local println_ts = util.println_ts
|
||||
---@param coord_listen integer
|
||||
supervisor.comms = function (num_reactors, modem, dev_listen, coord_listen)
|
||||
local self = {
|
||||
ln_seq_num = 0,
|
||||
num_reactors = num_reactors,
|
||||
modem = modem,
|
||||
dev_listen = dev_listen,
|
||||
@@ -59,15 +58,27 @@ supervisor.comms = function (num_reactors, modem, dev_listen, coord_listen)
|
||||
-- send PLC link request responses
|
||||
---@param dest integer
|
||||
---@param msg table
|
||||
local _send_plc_linking = function (dest, msg)
|
||||
local _send_plc_linking = function (seq_id, dest, msg)
|
||||
local s_pkt = comms.scada_packet()
|
||||
local r_pkt = comms.rplc_packet()
|
||||
|
||||
r_pkt.make(0, RPLC_TYPES.LINK_REQ, msg)
|
||||
s_pkt.make(self.ln_seq_num, PROTOCOLS.RPLC, r_pkt.raw_sendable())
|
||||
s_pkt.make(seq_id, PROTOCOLS.RPLC, r_pkt.raw_sendable())
|
||||
|
||||
self.modem.transmit(dest, self.dev_listen, s_pkt.raw_sendable())
|
||||
end
|
||||
|
||||
-- send RTU advertisement responses
|
||||
---@param seq_id integer
|
||||
---@param dest integer
|
||||
local _send_remote_linked = function (seq_id, dest)
|
||||
local s_pkt = comms.scada_packet()
|
||||
local m_pkt = comms.mgmt_packet()
|
||||
|
||||
m_pkt.make(SCADA_MGMT_TYPES.REMOTE_LINKED, {})
|
||||
s_pkt.make(seq_id, PROTOCOLS.SCADA_MGMT, m_pkt.raw_sendable())
|
||||
|
||||
self.modem.transmit(dest, self.dev_listen, s_pkt.raw_sendable())
|
||||
self.ln_seq_num = self.ln_seq_num + 1
|
||||
end
|
||||
|
||||
-- PUBLIC FUNCTIONS --
|
||||
@@ -143,18 +154,27 @@ supervisor.comms = function (num_reactors, modem, dev_listen, coord_listen)
|
||||
|
||||
if protocol == PROTOCOLS.MODBUS_TCP then
|
||||
-- MODBUS response
|
||||
if session ~= nil then
|
||||
-- pass the packet onto the session handler
|
||||
session.in_queue.push_packet(packet)
|
||||
else
|
||||
-- any other packet should be session related, discard it
|
||||
log.debug("discarding MODBUS_TCP packet without a known session")
|
||||
end
|
||||
elseif protocol == PROTOCOLS.RPLC then
|
||||
-- reactor PLC packet
|
||||
if session ~= nil then
|
||||
if packet.type == RPLC_TYPES.LINK_REQ then
|
||||
-- new device on this port? that's a collision
|
||||
log.debug("PLC_LNK: request from existing connection received on " .. r_port .. ", responding with collision")
|
||||
_send_plc_linking(r_port, { RPLC_LINKING.COLLISION })
|
||||
_send_plc_linking(packet.scada_frame.seq_num() + 1, r_port, { RPLC_LINKING.COLLISION })
|
||||
else
|
||||
-- pass the packet onto the session handler
|
||||
session.in_queue.push_packet(packet)
|
||||
end
|
||||
else
|
||||
local next_seq_id = packet.scada_frame.seq_num() + 1
|
||||
|
||||
-- unknown session, is this a linking request?
|
||||
if packet.type == RPLC_TYPES.LINK_REQ then
|
||||
if packet.length == 1 then
|
||||
@@ -163,12 +183,12 @@ supervisor.comms = function (num_reactors, modem, dev_listen, coord_listen)
|
||||
if plc_id == false then
|
||||
-- reactor already has a PLC assigned
|
||||
log.debug("PLC_LNK: assignment collision with reactor " .. packet.data[1])
|
||||
_send_plc_linking(r_port, { RPLC_LINKING.COLLISION })
|
||||
_send_plc_linking(next_seq_id, r_port, { RPLC_LINKING.COLLISION })
|
||||
else
|
||||
-- got an ID; assigned to a reactor successfully
|
||||
println("connected to reactor " .. packet.data[1] .. " PLC (port " .. r_port .. ")")
|
||||
log.debug("PLC_LNK: allowed for device at " .. r_port)
|
||||
_send_plc_linking(r_port, { RPLC_LINKING.ALLOW })
|
||||
_send_plc_linking(next_seq_id, r_port, { RPLC_LINKING.ALLOW })
|
||||
end
|
||||
else
|
||||
log.debug("PLC_LNK: new linking packet length mismatch")
|
||||
@@ -176,7 +196,7 @@ supervisor.comms = function (num_reactors, modem, dev_listen, coord_listen)
|
||||
else
|
||||
-- force a re-link
|
||||
log.debug("PLC_LNK: no session but not a link, force relink")
|
||||
_send_plc_linking(r_port, { RPLC_LINKING.DENY })
|
||||
_send_plc_linking(next_seq_id, r_port, { RPLC_LINKING.DENY })
|
||||
end
|
||||
end
|
||||
elseif protocol == PROTOCOLS.SCADA_MGMT then
|
||||
@@ -184,6 +204,18 @@ supervisor.comms = function (num_reactors, modem, dev_listen, coord_listen)
|
||||
if session ~= nil then
|
||||
-- pass the packet onto the session handler
|
||||
session.in_queue.push_packet(packet)
|
||||
else
|
||||
-- is this an RTU advertisement?
|
||||
if packet.type == SCADA_MGMT_TYPES.RTU_ADVERT then
|
||||
local rtu_id = svsessions.establish_rtu_session(l_port, r_port, packet.data)
|
||||
|
||||
println("connected to RTU (port " .. r_port .. ")")
|
||||
log.debug("RTU_ADVERT: linked " .. r_port)
|
||||
_send_remote_linked(packet.scada_frame.seq_num() + 1, r_port)
|
||||
else
|
||||
-- any other packet should be session related, discard it
|
||||
log.debug("discarding SCADA_MGMT packet without a known session")
|
||||
end
|
||||
end
|
||||
else
|
||||
log.debug("illegal packet type " .. protocol .. " on device listening channel")
|
||||
|
||||
Reference in New Issue