#20 process target charge level
This commit is contained in:
@@ -30,9 +30,9 @@ local START_STATUS = {
|
||||
BLADE_MISMATCH = 2
|
||||
}
|
||||
|
||||
local charge_Kp = 1.0
|
||||
local charge_Kp = 0.275
|
||||
local charge_Ki = 0.0
|
||||
local charge_Kd = 0.0
|
||||
local charge_Kd = 4.5
|
||||
|
||||
local rate_Kp = 2.45
|
||||
local rate_Ki = 0.4825
|
||||
@@ -80,9 +80,9 @@ function facility.new(num_reactors, cooling_conf)
|
||||
last_time = 0.0,
|
||||
-- statistics
|
||||
im_stat_init = false,
|
||||
avg_charge = util.mov_avg(10, 0.0),
|
||||
avg_inflow = util.mov_avg(10, 0.0),
|
||||
avg_outflow = util.mov_avg(10, 0.0)
|
||||
avg_charge = util.mov_avg(3, 0.0),
|
||||
avg_inflow = util.mov_avg(6, 0.0),
|
||||
avg_outflow = util.mov_avg(6, 0.0)
|
||||
}
|
||||
|
||||
-- create units
|
||||
@@ -290,8 +290,6 @@ function facility.new(num_reactors, cooling_conf)
|
||||
self.start_fail = START_STATUS.NO_UNITS
|
||||
else
|
||||
self.charge_conversion = blade_count * POWER_PER_BLADE
|
||||
|
||||
log.debug(util.c("FAC: starting auto control: chg_conv = ", self.charge_conversion, ", blade_count = ", blade_count, ", max_burn = ", self.max_burn_combined))
|
||||
end
|
||||
elseif self.mode == PROCESS.INACTIVE then
|
||||
for i = 1, #self.prio_defs do
|
||||
@@ -357,29 +355,20 @@ function facility.new(num_reactors, cooling_conf)
|
||||
self.saturated = self.burn_target == self.max_burn_combined or unallocated > 0
|
||||
elseif self.mode == PROCESS.CHARGE then
|
||||
-- target a level of charge
|
||||
-- convert to kFE to make constants not microscopic
|
||||
local error = (self.charge_setpoint - avg_charge) / 1000000
|
||||
|
||||
if state_changed then
|
||||
self.time_start = now
|
||||
self.last_time = now
|
||||
log.debug(util.c("FAC: CHARGE mode first call completed"))
|
||||
elseif self.waiting_on_ramp then
|
||||
if _all_units_ramped() then
|
||||
self.waiting_on_ramp = false
|
||||
self.last_error = 0
|
||||
self.accumulator = 0
|
||||
|
||||
self.time_start = now
|
||||
self.last_time = now
|
||||
self.last_error = 0
|
||||
self.accumulator = 0
|
||||
self.status_text = { "CHARGE MODE", "running control loop" }
|
||||
log.info(util.c("FAC: CHARGE mode starting PID control"))
|
||||
elseif self.last_update ~= charge_update then
|
||||
-- convert to kFE to make constants not microscopic
|
||||
local error = util.round((self.charge_setpoint - avg_charge) / 1000) / 1000
|
||||
|
||||
self.status_text = { "CHARGE MODE", "running control loop" }
|
||||
log.info(util.c("FAC: CHARGE mode initial ramp completed"))
|
||||
end
|
||||
end
|
||||
|
||||
if not self.waiting_on_ramp and self.last_update ~= rate_update then
|
||||
-- stop accumulator when saturated to avoid windup, deadband accumulator at 1kFE to avoid windup
|
||||
if (not self.saturated) and (math.abs(error) >= 0.001) then
|
||||
-- stop accumulator when saturated to avoid windup
|
||||
if not self.saturated then
|
||||
self.accumulator = self.accumulator + (error * (now - self.last_time))
|
||||
end
|
||||
|
||||
@@ -398,16 +387,13 @@ function facility.new(num_reactors, cooling_conf)
|
||||
|
||||
self.saturated = output ~= out_c
|
||||
|
||||
log.debug(util.sprintf("PROC_CHRG[%f] { CHRG[%f] ERR[%f] INT[%f] => OUT[%f] OUT_C[%f] <= P[%f] I[%f] D[%d] }",
|
||||
log.debug(util.sprintf("CHARGE[%f] { CHRG[%f] ERR[%f] INT[%f] => OUT[%f] OUT_C[%f] <= P[%f] I[%f] D[%d] }",
|
||||
runtime, avg_charge, error, integral, output, out_c, P, I, D))
|
||||
|
||||
_allocate_burn_rate(out_c, self.initial_ramp)
|
||||
_allocate_burn_rate(out_c, true)
|
||||
|
||||
self.last_time = now
|
||||
|
||||
if self.initial_ramp then
|
||||
self.waiting_on_ramp = true
|
||||
end
|
||||
self.last_error = error
|
||||
end
|
||||
|
||||
self.last_update = charge_update
|
||||
@@ -450,7 +436,7 @@ function facility.new(num_reactors, cooling_conf)
|
||||
-- convert to MFE (in rounded kFE) to make constants not microscopic
|
||||
local error = util.round((self.gen_rate_setpoint - avg_inflow) / 1000) / 1000
|
||||
|
||||
-- stop accumulator when saturated to avoid windup, deadband accumulator at 1kFE to avoid windup
|
||||
-- stop accumulator when saturated to avoid windup
|
||||
if not self.saturated then
|
||||
self.accumulator = self.accumulator + (error * (now - self.last_time))
|
||||
end
|
||||
@@ -656,7 +642,7 @@ function facility.new(num_reactors, cooling_conf)
|
||||
end
|
||||
|
||||
if (type(config.charge_target) == "number") and config.charge_target >= 0 then
|
||||
self.charge_setpoint = config.charge_target
|
||||
self.charge_setpoint = config.charge_target * 1000000 -- convert MFE to FE
|
||||
end
|
||||
|
||||
if (type(config.gen_target) == "number") and config.gen_target >= 0 then
|
||||
|
||||
Reference in New Issue