Compare commits
112 Commits
v1.8.3-bet
...
v1.8.9-bet
| Author | SHA1 | Date | |
|---|---|---|---|
|
|
3c7fff28c9 | ||
|
|
d1e4ea586e | ||
|
|
4e789ab92d | ||
|
|
0892a57d35 | ||
|
|
1bc4828010 | ||
|
|
fb5a9d5d9e | ||
|
|
adbf1f2f78 | ||
|
|
2f99aaeedb | ||
|
|
f9917b786c | ||
|
|
d6185e0183 | ||
|
|
cdd31508d9 | ||
|
|
83d62991f8 | ||
|
|
f207a950e4 | ||
|
|
0b0051dc2f | ||
|
|
f152c37ea9 | ||
|
|
372fd426d8 | ||
|
|
8347afb6d0 | ||
|
|
10d0a9763a | ||
|
|
96691d773a | ||
|
|
910509d764 | ||
|
|
158cc39b80 | ||
|
|
940f71aa35 | ||
|
|
788cef8f86 | ||
|
|
baaef862ab | ||
|
|
96db709ced | ||
|
|
c47fa5433f | ||
|
|
440b724798 | ||
|
|
126d6eb163 | ||
|
|
8ac46faf36 | ||
|
|
f112746e12 | ||
|
|
76f21e925b | ||
|
|
a330249c7e | ||
|
|
bbc64c8dc2 | ||
|
|
bb062cf397 | ||
|
|
53bb36ce8d | ||
|
|
8237113577 | ||
|
|
02906ae707 | ||
|
|
6d0e777e68 | ||
|
|
36468c4043 | ||
|
|
1cf7375311 | ||
|
|
ca55948286 | ||
|
|
195f59178f | ||
|
|
e416faf313 | ||
|
|
20bff48cfd | ||
|
|
1a9892b291 | ||
|
|
827953c0a1 | ||
|
|
56e69e3a29 | ||
|
|
1984b63837 | ||
|
|
36b12d5dea | ||
|
|
3e83c8e2c6 | ||
|
|
1fa8c03dff | ||
|
|
d6de9c266b | ||
|
|
2142c1b4f7 | ||
|
|
cafba6c67a | ||
|
|
6eccebbe39 | ||
|
|
5e9f03c900 | ||
|
|
7374bb02d1 | ||
|
|
d19794ae4f | ||
|
|
108cf75cad | ||
|
|
34cbb6be39 | ||
|
|
907f27baf8 | ||
|
|
4710fa7cee | ||
|
|
bfa1f4d0c6 | ||
|
|
737e0d72b0 | ||
|
|
6edeb3e3b8 | ||
|
|
fb00e98a5b | ||
|
|
4f952eff83 | ||
|
|
1eede97c08 | ||
|
|
95419562ee | ||
|
|
7b85d947c4 | ||
|
|
08e670091a | ||
|
|
1348b632a8 | ||
|
|
8cd5162362 | ||
|
|
1c410a89d8 | ||
|
|
6a931fced4 | ||
|
|
622e2eeb90 | ||
|
|
42cd9fff0c | ||
|
|
2a85a438ba | ||
|
|
338b3b1615 | ||
|
|
363f164f47 | ||
|
|
739f04ece9 | ||
|
|
c6ade68ce2 | ||
|
|
7d60e259e2 | ||
|
|
cd71c6a9c1 | ||
|
|
26fe130609 | ||
|
|
95f87b1b05 | ||
|
|
aebdf3e8df | ||
|
|
5d4fc36256 | ||
|
|
b799d785b9 | ||
|
|
d55442fa53 | ||
|
|
c870b749a4 | ||
|
|
4421cbc0c5 | ||
|
|
b6a3305f23 | ||
|
|
5680260136 | ||
|
|
bc66ea6ecb | ||
|
|
1b20218445 | ||
|
|
466e442353 | ||
|
|
9e6751f47f | ||
|
|
f868923905 | ||
|
|
5d3fd6d939 | ||
|
|
37659d687e | ||
|
|
f23b7e2c2f | ||
|
|
55ccdd63d4 | ||
|
|
5c88890ed4 | ||
|
|
fa0185c9a4 | ||
|
|
e1ed9a8e5e | ||
|
|
9f7e3bc282 | ||
|
|
4ec060ba24 | ||
|
|
b1f1753a8d | ||
|
|
94a62f8c31 | ||
|
|
e6f49f256c | ||
|
|
a048b0aa4a |
1
.github/FUNDING.yml
vendored
Normal file
1
.github/FUNDING.yml
vendored
Normal file
@@ -0,0 +1 @@
|
||||
ko_fi: mikayla_f
|
||||
2
.github/workflows/check.yml
vendored
2
.github/workflows/check.yml
vendored
@@ -5,12 +5,10 @@ on:
|
||||
push:
|
||||
branches:
|
||||
- main
|
||||
- latest
|
||||
- devel
|
||||
pull_request:
|
||||
branches:
|
||||
- main
|
||||
- latest
|
||||
- devel
|
||||
jobs:
|
||||
check:
|
||||
|
||||
18
.github/workflows/manifest.yml
vendored
18
.github/workflows/manifest.yml
vendored
@@ -6,7 +6,6 @@ on:
|
||||
push:
|
||||
branches:
|
||||
- main
|
||||
- latest
|
||||
- devel
|
||||
|
||||
# Sets permissions of the GITHUB_TOKEN to allow deployment to GitHub Pages
|
||||
@@ -43,7 +42,7 @@ jobs:
|
||||
- name: Create outputs folders
|
||||
if: success() || failure()
|
||||
shell: bash
|
||||
run: mkdir deploy; mkdir deploy/manifests; mkdir deploy/manifests/main deploy/manifests/latest deploy/manifests/devel
|
||||
run: mkdir deploy; mkdir deploy/manifests; mkdir deploy/manifests/main deploy/manifests/devel
|
||||
- name: Generate manifest and shields for main branch
|
||||
id: manifest-main
|
||||
if: ${{ (success() || failure()) && steps.checkout-main.outcome == 'success' }}
|
||||
@@ -51,21 +50,6 @@ jobs:
|
||||
- name: Save main's manifest
|
||||
if: ${{ (success() || failure()) && steps.manifest-main.outcome == 'success' }}
|
||||
run: mv install_manifest.json deploy/manifests/main
|
||||
# Generate manifest for latest branch
|
||||
- name: Checkout latest
|
||||
id: checkout-latest
|
||||
if: success() || failure()
|
||||
uses: actions/checkout@v3
|
||||
with:
|
||||
ref: 'latest'
|
||||
clean: false
|
||||
- name: Generate manifest for latest
|
||||
id: manifest-latest
|
||||
if: ${{ (success() || failure()) && steps.checkout-latest.outcome == 'success' }}
|
||||
run: python imgen.py
|
||||
- name: Save latest's manifest
|
||||
if: ${{ (success() || failure()) && steps.manifest-latest.outcome == 'success' }}
|
||||
run: mv install_manifest.json deploy/manifests/latest
|
||||
# Generate manifest for devel branch
|
||||
- name: Checkout devel
|
||||
id: checkout-devel
|
||||
|
||||
2
LICENSE
2
LICENSE
@@ -1,6 +1,6 @@
|
||||
MIT License
|
||||
|
||||
Copyright © 2022 - 2023 Mikayla Fischler
|
||||
Copyright © 2022 - 2024 Mikayla Fischler
|
||||
|
||||
Permission is hereby granted, free of charge, to any person obtaining a copy
|
||||
of this software and associated documentation files (the "Software"), to deal
|
||||
|
||||
132
ccmsi.lua
132
ccmsi.lua
@@ -1,7 +1,7 @@
|
||||
--[[
|
||||
CC-MEK-SCADA Installer Utility
|
||||
|
||||
Copyright (c) 2023 Mikayla Fischler
|
||||
Copyright (c) 2023 - 2024 Mikayla Fischler
|
||||
|
||||
Permission is hereby granted, free of charge, to any person obtaining a copy of this software and
|
||||
associated documentation files (the "Software"), to deal in the Software without restriction,
|
||||
@@ -18,7 +18,7 @@ SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE.
|
||||
local function println(message) print(tostring(message)) end
|
||||
local function print(message) term.write(tostring(message)) end
|
||||
|
||||
local CCMSI_VERSION = "v1.11c"
|
||||
local CCMSI_VERSION = "v1.14"
|
||||
|
||||
local install_dir = "/.install-cache"
|
||||
local manifest_path = "https://mikaylafischler.github.io/cc-mek-scada/manifests/"
|
||||
@@ -26,7 +26,7 @@ local repo_path = "http://raw.githubusercontent.com/MikaylaFischler/cc-mek-scada
|
||||
|
||||
local opts = { ... }
|
||||
local mode, app, target
|
||||
local install_manifest = manifest_path .. "main/install_manifest.json"
|
||||
local install_manifest = manifest_path.."main/install_manifest.json"
|
||||
|
||||
local function red() term.setTextColor(colors.red) end
|
||||
local function orange() term.setTextColor(colors.orange) end
|
||||
@@ -59,17 +59,17 @@ local function ask_y_n(question, default)
|
||||
end
|
||||
|
||||
-- print out a white + blue text message
|
||||
local function pkg_message(message, package) white();print(message .. " ");blue();println(package);white() end
|
||||
local function pkg_message(message, package) white();print(message.." ");blue();println(package);white() end
|
||||
|
||||
-- indicate actions to be taken based on package differences for installs/updates
|
||||
local function show_pkg_change(name, v)
|
||||
if v.v_local ~= nil then
|
||||
if v.v_local ~= v.v_remote then
|
||||
print("[" .. name .. "] updating ");blue();print(v.v_local);white();print(" \xbb ");blue();println(v.v_remote);white()
|
||||
print("["..name.."] updating ");blue();print(v.v_local);white();print(" \xbb ");blue();println(v.v_remote);white()
|
||||
elseif mode == "install" then
|
||||
pkg_message("[" .. name .. "] reinstalling", v.v_local)
|
||||
pkg_message("["..name.."] reinstalling", v.v_local)
|
||||
end
|
||||
else pkg_message("[" .. name .. "] new install of", v.v_remote) end
|
||||
else pkg_message("["..name.."] new install of", v.v_remote) end
|
||||
return v.v_local ~= v.v_remote
|
||||
end
|
||||
|
||||
@@ -90,7 +90,7 @@ local function get_remote_manifest()
|
||||
local response, error = http.get(install_manifest)
|
||||
if response == nil then
|
||||
orange();println("Failed to get installation manifest from GitHub, cannot update or install.")
|
||||
red();println("HTTP error: " .. error);white()
|
||||
red();println("HTTP error: "..error);white()
|
||||
return false, {}
|
||||
end
|
||||
|
||||
@@ -155,46 +155,44 @@ local function _clean_dir(dir, tree)
|
||||
if tree == nil then tree = {} end
|
||||
local ls = fs.list(dir)
|
||||
for _, val in pairs(ls) do
|
||||
local path = dir .. "/" .. val
|
||||
local path = dir.."/"..val
|
||||
if fs.isDir(path) then
|
||||
_clean_dir(path, tree[val])
|
||||
if #fs.list(path) == 0 then fs.delete(path);println("deleted " .. path) end
|
||||
elseif (not _in_array(val, tree)) and (val ~= "config.lua" ) then ---@fixme remove condition after migration to settings files
|
||||
if #fs.list(path) == 0 then fs.delete(path);println("deleted "..path) end
|
||||
elseif (not _in_array(val, tree)) and (val ~= "config.lua" ) then
|
||||
fs.delete(path)
|
||||
println("deleted " .. path)
|
||||
println("deleted "..path)
|
||||
end
|
||||
end
|
||||
end
|
||||
|
||||
-- go through app/common directories to delete unused files
|
||||
local function clean(manifest)
|
||||
local root_ext = false
|
||||
local tree = gen_tree(manifest)
|
||||
|
||||
table.insert(tree, "install_manifest.json")
|
||||
table.insert(tree, "ccmsi.lua")
|
||||
table.insert(tree, "log.txt") ---@fixme fix after migration to settings files?
|
||||
|
||||
lgray()
|
||||
|
||||
local ls = fs.list("/")
|
||||
for _, val in pairs(ls) do
|
||||
if fs.isDir(val) then
|
||||
if tree[val] ~= nil then _clean_dir("/" .. val, tree[val]) end
|
||||
if #fs.list(val) == 0 then fs.delete(val);println("deleted " .. val) end
|
||||
if fs.isDriveRoot(val) then
|
||||
yellow();println("skipped mount '"..val.."'")
|
||||
elseif fs.isDir(val) then
|
||||
if tree[val] ~= nil then lgray();_clean_dir("/"..val, tree[val])
|
||||
else white(); if ask_y_n("delete the unused directory '"..val.."'") then lgray();_clean_dir("/"..val) end end
|
||||
if #fs.list(val) == 0 then fs.delete(val);lgray();println("deleted empty directory '"..val.."'") end
|
||||
elseif not _in_array(val, tree) and (string.find(val, ".settings") == nil) then
|
||||
root_ext = true
|
||||
yellow();println(val .. " not used")
|
||||
white();if ask_y_n("delete the unused file '"..val.."'") then fs.delete(val);lgray();println("deleted "..val) end
|
||||
end
|
||||
end
|
||||
|
||||
white()
|
||||
if root_ext then println("Files in root directory won't be automatically deleted.") end
|
||||
end
|
||||
|
||||
-- get and validate command line options
|
||||
|
||||
println("-- CC Mekanism SCADA Installer " .. CCMSI_VERSION .. " --")
|
||||
println("-- CC Mekanism SCADA Installer "..CCMSI_VERSION.." --")
|
||||
|
||||
if #opts == 0 or opts[1] == "help" then
|
||||
println("usage: ccmsi <mode> <app> <branch>")
|
||||
@@ -204,8 +202,8 @@ if #opts == 0 or opts[1] == "help" then
|
||||
yellow()
|
||||
println(" ccmsi check <branch> for target")
|
||||
lgray()
|
||||
println(" install - fresh install, overwrites config.lua")
|
||||
println(" update - update files EXCEPT for config.lua")
|
||||
println(" install - fresh install")
|
||||
println(" update - update files")
|
||||
println(" uninstall - delete files INCLUDING config/logs")
|
||||
white();println("<app>");lgray()
|
||||
println(" reactor-plc - reactor PLC firmware")
|
||||
@@ -215,7 +213,7 @@ if #opts == 0 or opts[1] == "help" then
|
||||
println(" pocket - pocket application")
|
||||
println(" installer - ccmsi installer (update only)")
|
||||
white();println("<branch>")
|
||||
lgray();println(" main (default) | latest | devel");white()
|
||||
lgray();println(" main (default) | devel");white()
|
||||
return
|
||||
else
|
||||
mode = get_opt(opts[1], { "check", "install", "update", "uninstall" })
|
||||
@@ -235,14 +233,14 @@ else
|
||||
|
||||
-- determine target
|
||||
if mode == "check" then target = opts[2] else target = opts[3] end
|
||||
if (target ~= "main") and (target ~= "latest") and (target ~= "devel") then
|
||||
if (target ~= "main") and (target ~= "devel") then
|
||||
if (target and target ~= "") then yellow();println("Unknown target, defaulting to 'main'");white() end
|
||||
target = "main"
|
||||
end
|
||||
|
||||
-- set paths
|
||||
install_manifest = manifest_path .. target .. "/install_manifest.json"
|
||||
repo_path = repo_path .. target .. "/"
|
||||
install_manifest = manifest_path..target.."/install_manifest.json"
|
||||
repo_path = repo_path..target.."/"
|
||||
end
|
||||
|
||||
-- run selected mode
|
||||
@@ -262,7 +260,7 @@ if mode == "check" then
|
||||
-- list all versions
|
||||
for key, value in pairs(manifest.versions) do
|
||||
term.setTextColor(colors.purple)
|
||||
print(string.format("%-14s", "[" .. key .. "]"))
|
||||
print(string.format("%-14s", "["..key.."]"))
|
||||
if key == "installer" or (local_ok and (local_manifest.versions[key] ~= nil)) then
|
||||
blue();print(local_manifest.versions[key])
|
||||
if value ~= local_manifest.versions[key] then
|
||||
@@ -317,10 +315,10 @@ elseif mode == "install" or mode == "update" then
|
||||
if not update_installer then yellow();println("A different version of the installer is available, it is recommended to update to it.");white() end
|
||||
if update_installer or ask_y_n("Would you like to update now") then
|
||||
lgray();println("GET ccmsi.lua")
|
||||
local dl, err = http.get(repo_path .. "ccmsi.lua")
|
||||
local dl, err = http.get(repo_path.."ccmsi.lua")
|
||||
|
||||
if dl == nil then
|
||||
red();println("HTTP Error " .. err)
|
||||
red();println("HTTP Error "..err)
|
||||
println("Installer download failed.");white()
|
||||
else
|
||||
local handle = fs.open(debug.getinfo(1, "S").source:sub(2), "w") -- this file, regardless of name or location
|
||||
@@ -344,12 +342,8 @@ elseif mode == "install" or mode == "update" then
|
||||
ver.lockbox.v_remote = manifest.versions.lockbox
|
||||
|
||||
green()
|
||||
if mode == "install" then
|
||||
println("Installing " .. app .. " files...")
|
||||
elseif mode == "update" then
|
||||
println("Updating " .. app .. " files... (keeping old config.lua)")
|
||||
end
|
||||
white()
|
||||
if mode == "install" then print("Installing ") else print("Updating ") end
|
||||
println(app.." files...");white()
|
||||
|
||||
ver.boot.changed = show_pkg_change("bootldr", ver.boot)
|
||||
ver.common.changed = show_pkg_change("common", ver.common)
|
||||
@@ -375,7 +369,6 @@ elseif mode == "install" or mode == "update" then
|
||||
local file_list = manifest.files
|
||||
local size_list = manifest.sizes
|
||||
local dependencies = manifest.depends[app]
|
||||
local config_file = app .. "/config.lua"
|
||||
|
||||
table.insert(dependencies, app)
|
||||
|
||||
@@ -422,15 +415,15 @@ elseif mode == "install" or mode == "update" then
|
||||
|
||||
local files = file_list[dependency]
|
||||
for _, file in pairs(files) do
|
||||
println("GET " .. file)
|
||||
local dl, err = http.get(repo_path .. file)
|
||||
println("GET "..file)
|
||||
local dl, err = http.get(repo_path..file)
|
||||
|
||||
if dl == nil then
|
||||
red();println("HTTP Error " .. err)
|
||||
red();println("HTTP Error "..err)
|
||||
success = false
|
||||
break
|
||||
else
|
||||
local handle = fs.open(install_dir .. "/" .. file, "w")
|
||||
local handle = fs.open(install_dir.."/"..file, "w")
|
||||
handle.write(dl.readAll())
|
||||
handle.close()
|
||||
end
|
||||
@@ -449,11 +442,9 @@ elseif mode == "install" or mode == "update" then
|
||||
|
||||
local files = file_list[dependency]
|
||||
for _, file in pairs(files) do
|
||||
if mode == "install" or file ~= config_file then
|
||||
local temp_file = install_dir .. "/" .. file
|
||||
if fs.exists(file) then fs.delete(file) end
|
||||
fs.move(temp_file, file)
|
||||
end
|
||||
local temp_file = install_dir.."/"..file
|
||||
if fs.exists(file) then fs.delete(file) end
|
||||
fs.move(temp_file, file)
|
||||
end
|
||||
end
|
||||
end
|
||||
@@ -486,19 +477,17 @@ elseif mode == "install" or mode == "update" then
|
||||
|
||||
local files = file_list[dependency]
|
||||
for _, file in pairs(files) do
|
||||
if mode == "install" or file ~= config_file then
|
||||
println("GET " .. file)
|
||||
local dl, err = http.get(repo_path .. file)
|
||||
println("GET "..file)
|
||||
local dl, err = http.get(repo_path..file)
|
||||
|
||||
if dl == nil then
|
||||
red();println("HTTP Error " .. err)
|
||||
success = false
|
||||
break
|
||||
else
|
||||
local handle = fs.open("/" .. file, "w")
|
||||
handle.write(dl.readAll())
|
||||
handle.close()
|
||||
end
|
||||
if dl == nil then
|
||||
red();println("HTTP Error "..err)
|
||||
success = false
|
||||
break
|
||||
else
|
||||
local handle = fs.open("/"..file, "w")
|
||||
handle.write(dl.readAll())
|
||||
handle.close()
|
||||
end
|
||||
end
|
||||
end
|
||||
@@ -528,11 +517,11 @@ elseif mode == "uninstall" then
|
||||
end
|
||||
|
||||
if manifest.versions[app] == nil then
|
||||
red();println("Error: '" .. app .. "' is not installed.")
|
||||
red();println("Error: '"..app.."' is not installed.")
|
||||
return
|
||||
end
|
||||
|
||||
orange();println("Uninstalling all " .. app .. " files...")
|
||||
orange();println("Uninstalling all "..app.." files...")
|
||||
|
||||
-- ask for confirmation
|
||||
if not ask_y_n("Continue", false) then return end
|
||||
@@ -547,16 +536,16 @@ elseif mode == "uninstall" then
|
||||
|
||||
-- delete log file
|
||||
local log_deleted = false
|
||||
local settings_file = app .. ".settings"
|
||||
local legacy_config_file = app .. "/config.lua"
|
||||
local settings_file = app..".settings"
|
||||
local legacy_config_file = app.."/config.lua"
|
||||
|
||||
lgray()
|
||||
if fs.exists(legacy_config_file) then
|
||||
log_deleted = pcall(function ()
|
||||
local config = require(app .. ".config")
|
||||
local config = require(app..".config")
|
||||
if fs.exists(config.LOG_PATH) then
|
||||
fs.delete(config.LOG_PATH)
|
||||
println("deleted log file " .. config.LOG_PATH)
|
||||
println("deleted log file "..config.LOG_PATH)
|
||||
end
|
||||
end)
|
||||
elseif fs.exists(settings_file) and settings.load(settings_file) then
|
||||
@@ -564,7 +553,7 @@ elseif mode == "uninstall" then
|
||||
if log ~= nil and fs.exists(log) then
|
||||
log_deleted = true
|
||||
fs.delete(log)
|
||||
println("deleted log file " .. log)
|
||||
println("deleted log file "..log)
|
||||
end
|
||||
end
|
||||
|
||||
@@ -578,7 +567,7 @@ elseif mode == "uninstall" then
|
||||
for _, dependency in pairs(dependencies) do
|
||||
local files = file_list[dependency]
|
||||
for _, file in pairs(files) do
|
||||
if fs.exists(file) then fs.delete(file);println("deleted " .. file) end
|
||||
if fs.exists(file) then fs.delete(file);println("deleted "..file) end
|
||||
end
|
||||
|
||||
local folder = files[1]
|
||||
@@ -589,13 +578,16 @@ elseif mode == "uninstall" then
|
||||
|
||||
if fs.isDir(folder) then
|
||||
fs.delete(folder)
|
||||
println("deleted directory " .. folder)
|
||||
println("deleted directory "..folder)
|
||||
end
|
||||
end
|
||||
|
||||
if fs.exists(legacy_config_file) then
|
||||
fs.delete(legacy_config_file);println("deleted "..legacy_config_file)
|
||||
end
|
||||
|
||||
if fs.exists(settings_file) then
|
||||
fs.delete(settings_file)
|
||||
println("deleted " .. settings_file)
|
||||
fs.delete(settings_file);println("deleted "..settings_file)
|
||||
end
|
||||
|
||||
fs.delete("install_manifest.json")
|
||||
|
||||
@@ -1,15 +1,10 @@
|
||||
print("CONFIGURE> SCANNING FOR CONFIGURATOR...")
|
||||
|
||||
if fs.exists("reactor-plc/configure.lua") then
|
||||
require("reactor-plc.configure").configure()
|
||||
elseif fs.exists("rtu/configure.lua") then
|
||||
require("rtu.configure").configure()
|
||||
elseif fs.exists("supervisor/startup.lua") then
|
||||
print("CONFIGURE> SUPERVISOR CONFIGURATOR NOT YET IMPLEMENTED IN BETA")
|
||||
elseif fs.exists("coordinator/startup.lua") then
|
||||
print("CONFIGURE> COORDINATOR CONFIGURATOR NOT YET IMPLEMENTED IN BETA")
|
||||
elseif fs.exists("pocket/startup.lua") then
|
||||
print("CONFIGURE> POCKET CONFIGURATOR NOT YET IMPLEMENTED IN BETA")
|
||||
if fs.exists("reactor-plc/configure.lua") then require("reactor-plc.configure").configure()
|
||||
elseif fs.exists("rtu/configure.lua") then require("rtu.configure").configure()
|
||||
elseif fs.exists("supervisor/configure.lua") then require("supervisor.configure").configure()
|
||||
elseif fs.exists("coordinator/configure.lua") then require("coordinator.configure").configure()
|
||||
elseif fs.exists("pocket/configure.lua") then require("pocket.configure").configure()
|
||||
else
|
||||
print("CONFIGURE> NO CONFIGURATOR FOUND")
|
||||
print("CONFIGURE> EXIT")
|
||||
|
||||
@@ -1,41 +0,0 @@
|
||||
local config = {}
|
||||
|
||||
-- supervisor comms channel
|
||||
config.SVR_CHANNEL = 16240
|
||||
-- coordinator comms channel
|
||||
config.CRD_CHANNEL = 16243
|
||||
-- pocket comms channel
|
||||
config.PKT_CHANNEL = 16244
|
||||
-- max trusted modem message distance (0 to disable check)
|
||||
config.TRUSTED_RANGE = 0
|
||||
-- time in seconds (>= 2) before assuming a remote device is no longer active
|
||||
config.SV_TIMEOUT = 5
|
||||
config.API_TIMEOUT = 5
|
||||
-- facility authentication key (do NOT use one of your passwords)
|
||||
-- this enables verifying that messages are authentic
|
||||
-- all devices on the same network must use the same key
|
||||
-- config.AUTH_KEY = "SCADAfacility123"
|
||||
|
||||
-- expected number of reactor units, used only to require that number of unit monitors
|
||||
config.NUM_UNITS = 4
|
||||
|
||||
-- alarm sounder volume (0.0 to 3.0, 1.0 being standard max volume, this is the option given to to speaker.play())
|
||||
-- note: alarm sine waves are at half saturation, so that multiple will be required to reach full scale
|
||||
config.SOUNDER_VOLUME = 1.0
|
||||
|
||||
-- true for 24 hour time on main view screen
|
||||
config.TIME_24_HOUR = true
|
||||
|
||||
-- disable flow view (for legacy layouts)
|
||||
config.DISABLE_FLOW_VIEW = false
|
||||
|
||||
-- log path
|
||||
config.LOG_PATH = "/log.txt"
|
||||
-- log mode
|
||||
-- 0 = APPEND (adds to existing file on start)
|
||||
-- 1 = NEW (replaces existing file on start)
|
||||
config.LOG_MODE = 0
|
||||
-- true to log verbose debug messages
|
||||
config.LOG_DEBUG = false
|
||||
|
||||
return config
|
||||
1322
coordinator/configure.lua
Normal file
1322
coordinator/configure.lua
Normal file
File diff suppressed because it is too large
Load Diff
@@ -9,11 +9,6 @@ local process = require("coordinator.process")
|
||||
|
||||
local apisessions = require("coordinator.session.apisessions")
|
||||
|
||||
local dialog = require("coordinator.ui.dialog")
|
||||
|
||||
local print = util.print
|
||||
local println = util.println
|
||||
|
||||
local PROTOCOL = comms.PROTOCOL
|
||||
local DEVICE_TYPE = comms.DEVICE_TYPE
|
||||
local ESTABLISH_ACK = comms.ESTABLISH_ACK
|
||||
@@ -26,182 +21,155 @@ local LINK_TIMEOUT = 60.0
|
||||
|
||||
local coordinator = {}
|
||||
|
||||
-- request the user to select a monitor
|
||||
---@nodiscard
|
||||
---@param names table available monitors
|
||||
---@return boolean|string|nil
|
||||
local function ask_monitor(names)
|
||||
println("available monitors:")
|
||||
for i = 1, #names do
|
||||
print(" " .. names[i])
|
||||
end
|
||||
println("")
|
||||
println("select a monitor or type c to cancel")
|
||||
---@type crd_config
|
||||
local config = {}
|
||||
|
||||
local iface = dialog.ask_options(names, "c")
|
||||
coordinator.config = config
|
||||
|
||||
if iface ~= false and iface ~= nil then
|
||||
util.filter_table(names, function (x) return x ~= iface end)
|
||||
-- load the coordinator configuration<br>
|
||||
-- status of 0 is OK, 1 is bad config, 2 is bad monitor config
|
||||
---@return 0|1|2 status, nil|monitors_struct|string monitors (or error message)
|
||||
function coordinator.load_config()
|
||||
if not settings.load("/coordinator.settings") then return 1 end
|
||||
|
||||
config.UnitCount = settings.get("UnitCount")
|
||||
config.SpeakerVolume = settings.get("SpeakerVolume")
|
||||
config.Time24Hour = settings.get("Time24Hour")
|
||||
config.TempScale = settings.get("TempScale")
|
||||
|
||||
config.DisableFlowView = settings.get("DisableFlowView")
|
||||
config.MainDisplay = settings.get("MainDisplay")
|
||||
config.FlowDisplay = settings.get("FlowDisplay")
|
||||
config.UnitDisplays = settings.get("UnitDisplays")
|
||||
|
||||
config.SVR_Channel = settings.get("SVR_Channel")
|
||||
config.CRD_Channel = settings.get("CRD_Channel")
|
||||
config.PKT_Channel = settings.get("PKT_Channel")
|
||||
config.SVR_Timeout = settings.get("SVR_Timeout")
|
||||
config.API_Timeout = settings.get("API_Timeout")
|
||||
config.TrustedRange = settings.get("TrustedRange")
|
||||
config.AuthKey = settings.get("AuthKey")
|
||||
|
||||
config.LogMode = settings.get("LogMode")
|
||||
config.LogPath = settings.get("LogPath")
|
||||
config.LogDebug = settings.get("LogDebug")
|
||||
|
||||
local cfv = util.new_validator()
|
||||
|
||||
cfv.assert_type_int(config.UnitCount)
|
||||
cfv.assert_range(config.UnitCount, 1, 4)
|
||||
cfv.assert_type_bool(config.Time24Hour)
|
||||
cfv.assert_type_int(config.TempScale)
|
||||
cfv.assert_range(config.TempScale, 1, 4)
|
||||
|
||||
cfv.assert_type_bool(config.DisableFlowView)
|
||||
cfv.assert_type_table(config.UnitDisplays)
|
||||
|
||||
cfv.assert_type_num(config.SpeakerVolume)
|
||||
cfv.assert_range(config.SpeakerVolume, 0, 3)
|
||||
|
||||
cfv.assert_channel(config.SVR_Channel)
|
||||
cfv.assert_channel(config.CRD_Channel)
|
||||
cfv.assert_channel(config.PKT_Channel)
|
||||
|
||||
cfv.assert_type_num(config.SVR_Timeout)
|
||||
cfv.assert_min(config.SVR_Timeout, 2)
|
||||
cfv.assert_type_num(config.API_Timeout)
|
||||
cfv.assert_min(config.API_Timeout, 2)
|
||||
|
||||
cfv.assert_type_num(config.TrustedRange)
|
||||
cfv.assert_min(config.TrustedRange, 0)
|
||||
cfv.assert_type_str(config.AuthKey)
|
||||
|
||||
if type(config.AuthKey) == "string" then
|
||||
local len = string.len(config.AuthKey)
|
||||
cfv.assert_eq(len == 0 or len >= 8, true)
|
||||
end
|
||||
|
||||
return iface
|
||||
end
|
||||
cfv.assert_type_int(config.LogMode)
|
||||
cfv.assert_range(config.LogMode, 0, 1)
|
||||
cfv.assert_type_str(config.LogPath)
|
||||
cfv.assert_type_bool(config.LogDebug)
|
||||
|
||||
-- Monitor Setup
|
||||
|
||||
-- configure monitor layout
|
||||
---@param num_units integer number of units expected
|
||||
---@param disable_flow_view boolean disable flow view (legacy)
|
||||
---@return boolean success, monitors_struct? monitors
|
||||
function coordinator.configure_monitors(num_units, disable_flow_view)
|
||||
---@class monitors_struct
|
||||
local monitors = {
|
||||
primary = nil, ---@type table|nil
|
||||
primary_name = "",
|
||||
flow = nil, ---@type table|nil
|
||||
main = nil, ---@type table|nil
|
||||
main_name = "",
|
||||
flow = nil, ---@type table|nil
|
||||
flow_name = "",
|
||||
unit_displays = {},
|
||||
unit_name_map = {}
|
||||
}
|
||||
|
||||
local monitors_avail = ppm.get_monitor_list()
|
||||
local names = {}
|
||||
local available = {}
|
||||
local mon_cfv = util.new_validator()
|
||||
|
||||
-- get all interface names
|
||||
for iface, _ in pairs(monitors_avail) do
|
||||
table.insert(names, iface)
|
||||
table.insert(available, iface)
|
||||
end
|
||||
local names = {}
|
||||
for iface, _ in pairs(ppm.get_monitor_list()) do table.insert(names, iface) end
|
||||
|
||||
-- we need a certain number of monitors (1 per unit + 1 primary display + 1 flow display)
|
||||
local num_displays_needed = num_units + util.trinary(disable_flow_view, 1, 2)
|
||||
if #names < num_displays_needed then
|
||||
local message = "not enough monitors connected (need " .. num_displays_needed .. ")"
|
||||
println(message)
|
||||
log.warning(message)
|
||||
return false
|
||||
end
|
||||
local function setup_monitors()
|
||||
mon_cfv.assert_type_str(config.MainDisplay)
|
||||
if not config.DisableFlowView then mon_cfv.assert_type_str(config.FlowDisplay) end
|
||||
mon_cfv.assert_eq(#config.UnitDisplays, config.UnitCount)
|
||||
|
||||
-- attempt to load settings
|
||||
if not settings.load("/coord.settings") then
|
||||
log.warning("configure_monitors(): failed to load coordinator settings file (may not exist yet)")
|
||||
else
|
||||
local _primary = settings.get("PRIMARY_DISPLAY")
|
||||
local _flow = settings.get("FLOW_DISPLAY")
|
||||
local _unitd = settings.get("UNIT_DISPLAYS")
|
||||
if mon_cfv.valid() then
|
||||
local w, h, _
|
||||
|
||||
-- filter out already assigned monitors
|
||||
util.filter_table(available, function (x) return x ~= _primary end)
|
||||
util.filter_table(available, function (x) return x ~= _flow end)
|
||||
if type(_unitd) == "table" then
|
||||
util.filter_table(available, function (x) return not util.table_contains(_unitd, x) end)
|
||||
end
|
||||
end
|
||||
|
||||
---------------------
|
||||
-- PRIMARY DISPLAY --
|
||||
---------------------
|
||||
|
||||
local iface_primary_display = settings.get("PRIMARY_DISPLAY") ---@type boolean|string|nil
|
||||
|
||||
if not util.table_contains(names, iface_primary_display) then
|
||||
println("primary display is not connected")
|
||||
local response = dialog.ask_y_n("would you like to change it", true)
|
||||
if response == false then return false end
|
||||
iface_primary_display = nil
|
||||
end
|
||||
|
||||
while iface_primary_display == nil and #available > 0 do
|
||||
iface_primary_display = ask_monitor(available)
|
||||
end
|
||||
|
||||
if type(iface_primary_display) ~= "string" then return false end
|
||||
|
||||
settings.set("PRIMARY_DISPLAY", iface_primary_display)
|
||||
util.filter_table(available, function (x) return x ~= iface_primary_display end)
|
||||
|
||||
monitors.primary = ppm.get_periph(iface_primary_display)
|
||||
monitors.primary_name = iface_primary_display
|
||||
|
||||
--------------------------
|
||||
-- FLOW MONITOR DISPLAY --
|
||||
--------------------------
|
||||
|
||||
if not disable_flow_view then
|
||||
local iface_flow_display = settings.get("FLOW_DISPLAY") ---@type boolean|string|nil
|
||||
|
||||
if not util.table_contains(names, iface_flow_display) then
|
||||
println("flow monitor display is not connected")
|
||||
local response = dialog.ask_y_n("would you like to change it", true)
|
||||
if response == false then return false end
|
||||
iface_flow_display = nil
|
||||
end
|
||||
|
||||
while iface_flow_display == nil and #available > 0 do
|
||||
iface_flow_display = ask_monitor(available)
|
||||
end
|
||||
|
||||
if type(iface_flow_display) ~= "string" then return false end
|
||||
|
||||
settings.set("FLOW_DISPLAY", iface_flow_display)
|
||||
util.filter_table(available, function (x) return x ~= iface_flow_display end)
|
||||
|
||||
monitors.flow = ppm.get_periph(iface_flow_display)
|
||||
monitors.flow_name = iface_flow_display
|
||||
end
|
||||
|
||||
-------------------
|
||||
-- UNIT DISPLAYS --
|
||||
-------------------
|
||||
|
||||
local unit_displays = settings.get("UNIT_DISPLAYS")
|
||||
|
||||
if unit_displays == nil then
|
||||
unit_displays = {}
|
||||
for i = 1, num_units do
|
||||
local display = nil
|
||||
|
||||
while display == nil and #available > 0 do
|
||||
println("please select monitor for unit #" .. i)
|
||||
display = ask_monitor(available)
|
||||
if not util.table_contains(names, config.MainDisplay) then
|
||||
return 2, "Main monitor is not connected."
|
||||
end
|
||||
|
||||
if display == false then return false end
|
||||
monitors.main = ppm.get_periph(config.MainDisplay)
|
||||
monitors.main_name = config.MainDisplay
|
||||
|
||||
unit_displays[i] = display
|
||||
end
|
||||
else
|
||||
-- make sure all displays are connected
|
||||
for i = 1, num_units do
|
||||
local display = unit_displays[i]
|
||||
|
||||
if not util.table_contains(names, display) then
|
||||
println("unit #" .. i .. " display is not connected")
|
||||
local response = dialog.ask_y_n("would you like to change it", true)
|
||||
if response == false then return false end
|
||||
display = nil
|
||||
monitors.main.setTextScale(0.5)
|
||||
w, _ = ppm.monitor_block_size(monitors.main.getSize())
|
||||
if w ~= 8 then
|
||||
return 2, util.c("Main monitor width is incorrect (was ", w, ", must be 8).")
|
||||
end
|
||||
|
||||
while display == nil and #available > 0 do
|
||||
display = ask_monitor(available)
|
||||
if not config.DisableFlowView then
|
||||
if not util.table_contains(names, config.FlowDisplay) then
|
||||
return 2, "Flow monitor is not connected."
|
||||
end
|
||||
|
||||
monitors.flow = ppm.get_periph(config.FlowDisplay)
|
||||
monitors.flow_name = config.FlowDisplay
|
||||
|
||||
monitors.flow.setTextScale(0.5)
|
||||
w, _ = ppm.monitor_block_size(monitors.flow.getSize())
|
||||
if w ~= 8 then
|
||||
return 2, util.c("Flow monitor width is incorrect (was ", w, ", must be 8).")
|
||||
end
|
||||
end
|
||||
|
||||
if display == false then return false end
|
||||
for i = 1, config.UnitCount do
|
||||
local display = config.UnitDisplays[i]
|
||||
if type(display) ~= "string" or not util.table_contains(names, display) then
|
||||
return 2, "Unit " .. i .. " monitor is not connected."
|
||||
end
|
||||
|
||||
unit_displays[i] = display
|
||||
end
|
||||
monitors.unit_displays[i] = ppm.get_periph(display)
|
||||
monitors.unit_name_map[i] = display
|
||||
|
||||
monitors.unit_displays[i].setTextScale(0.5)
|
||||
w, h = ppm.monitor_block_size(monitors.unit_displays[i].getSize())
|
||||
if w ~= 4 or h ~= 4 then
|
||||
return 2, util.c("Unit ", i, " monitor size is incorrect (was ", w, " by ", h,", must be 4 by 4).")
|
||||
end
|
||||
end
|
||||
else return 2, "Monitor configuration invalid." end
|
||||
end
|
||||
|
||||
settings.set("UNIT_DISPLAYS", unit_displays)
|
||||
if not settings.save("/coord.settings") then
|
||||
log.warning("configure_monitors(): failed to save coordinator settings file")
|
||||
end
|
||||
if cfv.valid() then
|
||||
local ok, result, message = pcall(setup_monitors)
|
||||
assert(ok, util.c("fatal error while trying to verify monitors: ", result))
|
||||
if result == 2 then return 2, message end
|
||||
else return 1 end
|
||||
|
||||
for i = 1, #unit_displays do
|
||||
monitors.unit_displays[i] = ppm.get_periph(unit_displays[i])
|
||||
monitors.unit_name_map[i] = unit_displays[i]
|
||||
end
|
||||
|
||||
return true, monitors
|
||||
return 0, monitors
|
||||
end
|
||||
|
||||
-- dmesg print wrapper
|
||||
@@ -246,13 +214,8 @@ end
|
||||
---@nodiscard
|
||||
---@param version string coordinator version
|
||||
---@param nic nic network interface device
|
||||
---@param num_units integer number of configured units for number of monitors, checked against SV
|
||||
---@param crd_channel integer port of configured supervisor
|
||||
---@param svr_channel integer listening port for supervisor replys
|
||||
---@param pkt_channel integer listening port for pocket API
|
||||
---@param range integer trusted device connection range
|
||||
---@param sv_watchdog watchdog
|
||||
function coordinator.comms(version, nic, num_units, crd_channel, svr_channel, pkt_channel, range, sv_watchdog)
|
||||
function coordinator.comms(version, nic, sv_watchdog)
|
||||
local self = {
|
||||
sv_linked = false,
|
||||
sv_addr = comms.BROADCAST,
|
||||
@@ -267,16 +230,16 @@ function coordinator.comms(version, nic, num_units, crd_channel, svr_channel, pk
|
||||
est_task_done = nil
|
||||
}
|
||||
|
||||
comms.set_trusted_range(range)
|
||||
|
||||
-- PRIVATE FUNCTIONS --
|
||||
comms.set_trusted_range(config.TrustedRange)
|
||||
|
||||
-- configure network channels
|
||||
nic.closeAll()
|
||||
nic.open(crd_channel)
|
||||
nic.open(config.CRD_Channel)
|
||||
|
||||
-- link nic to apisessions
|
||||
apisessions.init(nic)
|
||||
-- pass config to apisessions
|
||||
apisessions.init(nic, config)
|
||||
|
||||
-- PRIVATE FUNCTIONS --
|
||||
|
||||
-- send a packet to the supervisor
|
||||
---@param msg_type MGMT_TYPE|CRDN_TYPE
|
||||
@@ -296,7 +259,7 @@ function coordinator.comms(version, nic, num_units, crd_channel, svr_channel, pk
|
||||
pkt.make(msg_type, msg)
|
||||
s_pkt.make(self.sv_addr, self.sv_seq_num, protocol, pkt.raw_sendable())
|
||||
|
||||
nic.transmit(svr_channel, crd_channel, s_pkt)
|
||||
nic.transmit(config.SVR_Channel, config.CRD_Channel, s_pkt)
|
||||
self.sv_seq_num = self.sv_seq_num + 1
|
||||
end
|
||||
|
||||
@@ -310,7 +273,7 @@ function coordinator.comms(version, nic, num_units, crd_channel, svr_channel, pk
|
||||
m_pkt.make(MGMT_TYPE.ESTABLISH, { ack })
|
||||
s_pkt.make(packet.src_addr(), packet.seq_num() + 1, PROTOCOL.SCADA_MGMT, m_pkt.raw_sendable())
|
||||
|
||||
nic.transmit(pkt_channel, crd_channel, s_pkt)
|
||||
nic.transmit(config.PKT_Channel, config.CRD_Channel, s_pkt)
|
||||
self.last_api_est_acks[packet.src_addr()] = ack
|
||||
end
|
||||
|
||||
@@ -339,24 +302,24 @@ function coordinator.comms(version, nic, num_units, crd_channel, svr_channel, pk
|
||||
|
||||
if not self.sv_linked then
|
||||
if self.est_tick_waiting == nil then
|
||||
self.est_start = util.time_s()
|
||||
self.est_start = os.clock()
|
||||
self.est_last = self.est_start
|
||||
|
||||
self.est_tick_waiting, self.est_task_done =
|
||||
coordinator.log_comms_connecting("attempting to connect to configured supervisor on channel " .. svr_channel)
|
||||
coordinator.log_comms_connecting("attempting to connect to configured supervisor on channel " .. config.SVR_Channel)
|
||||
|
||||
_send_establish()
|
||||
else
|
||||
self.est_tick_waiting(math.max(0, LINK_TIMEOUT - (util.time_s() - self.est_start)))
|
||||
self.est_tick_waiting(math.max(0, LINK_TIMEOUT - (os.clock() - self.est_start)))
|
||||
end
|
||||
|
||||
if abort or (util.time_s() - self.est_start) >= LINK_TIMEOUT then
|
||||
if abort or (os.clock() - self.est_start) >= LINK_TIMEOUT then
|
||||
self.est_task_done(false)
|
||||
|
||||
if abort then
|
||||
coordinator.log_comms("supervisor connection attempt cancelled by user")
|
||||
elseif self.sv_config_err then
|
||||
coordinator.log_comms("supervisor cooling configuration invalid, check supervisor config file")
|
||||
coordinator.log_comms("supervisor unit count does not match coordinator unit count, check configs")
|
||||
elseif not self.sv_linked then
|
||||
if self.last_est_ack == ESTABLISH_ACK.DENY then
|
||||
coordinator.log_comms("supervisor connection attempt denied")
|
||||
@@ -371,11 +334,11 @@ function coordinator.comms(version, nic, num_units, crd_channel, svr_channel, pk
|
||||
|
||||
ok = false
|
||||
elseif self.sv_config_err then
|
||||
coordinator.log_comms("supervisor cooling configuration invalid, check supervisor config file")
|
||||
coordinator.log_comms("supervisor unit count does not match coordinator unit count, check configs")
|
||||
ok = false
|
||||
elseif (util.time_s() - self.est_last) > 1.0 then
|
||||
elseif (os.clock() - self.est_last) > 1.0 then
|
||||
_send_establish()
|
||||
self.est_last = util.time_s()
|
||||
self.est_last = os.clock()
|
||||
end
|
||||
elseif self.est_tick_waiting ~= nil then
|
||||
self.est_task_done(true)
|
||||
@@ -405,10 +368,10 @@ function coordinator.comms(version, nic, num_units, crd_channel, svr_channel, pk
|
||||
end
|
||||
|
||||
-- send the auto process control configuration with a start command
|
||||
---@param config coord_auto_config configuration
|
||||
function public.send_auto_start(config)
|
||||
---@param auto_cfg coord_auto_config configuration
|
||||
function public.send_auto_start(auto_cfg)
|
||||
_send_sv(PROTOCOL.SCADA_CRDN, CRDN_TYPE.FAC_CMD, {
|
||||
FAC_COMMAND.START, config.mode, config.burn_target, config.charge_target, config.gen_target, config.limits
|
||||
FAC_COMMAND.START, auto_cfg.mode, auto_cfg.burn_target, auto_cfg.charge_target, auto_cfg.gen_target, auto_cfg.limits
|
||||
})
|
||||
end
|
||||
|
||||
@@ -464,9 +427,9 @@ function coordinator.comms(version, nic, num_units, crd_channel, svr_channel, pk
|
||||
local src_addr = packet.scada_frame.src_addr()
|
||||
local protocol = packet.scada_frame.protocol()
|
||||
|
||||
if l_chan ~= crd_channel then
|
||||
if l_chan ~= config.CRD_Channel then
|
||||
log.debug("received packet on unconfigured channel " .. l_chan, true)
|
||||
elseif r_chan == pkt_channel then
|
||||
elseif r_chan == config.PKT_Channel then
|
||||
if not self.sv_linked then
|
||||
log.debug("discarding pocket API packet before linked to supervisor")
|
||||
elseif protocol == PROTOCOL.SCADA_CRDN then
|
||||
@@ -526,7 +489,7 @@ function coordinator.comms(version, nic, num_units, crd_channel, svr_channel, pk
|
||||
else
|
||||
log.debug("illegal packet type " .. protocol .. " on pocket channel", true)
|
||||
end
|
||||
elseif r_chan == svr_channel then
|
||||
elseif r_chan == config.SVR_Channel then
|
||||
-- check sequence number
|
||||
if self.sv_r_seq_num == nil then
|
||||
self.sv_r_seq_num = packet.scada_frame.seq_num()
|
||||
@@ -699,24 +662,24 @@ function coordinator.comms(version, nic, num_units, crd_channel, svr_channel, pk
|
||||
-- connection with supervisor established
|
||||
if packet.length == 2 then
|
||||
local est_ack = packet.data[1]
|
||||
local config = packet.data[2]
|
||||
local sv_config = packet.data[2]
|
||||
|
||||
if est_ack == ESTABLISH_ACK.ALLOW then
|
||||
-- reset to disconnected before validating
|
||||
iocontrol.fp_link_state(types.PANEL_LINK_STATE.DISCONNECTED)
|
||||
|
||||
if type(config) == "table" and #config == 2 then
|
||||
if type(sv_config) == "table" and #sv_config == 2 then
|
||||
-- get configuration
|
||||
|
||||
---@class facility_conf
|
||||
local conf = {
|
||||
num_units = config[1], ---@type integer
|
||||
cooling = config[2] ---@type sv_cooling_conf
|
||||
num_units = sv_config[1], ---@type integer
|
||||
cooling = sv_config[2] ---@type sv_cooling_conf
|
||||
}
|
||||
|
||||
if conf.num_units == num_units then
|
||||
if conf.num_units == config.UnitCount then
|
||||
-- init io controller
|
||||
iocontrol.init(conf, public)
|
||||
iocontrol.init(conf, public, config.TempScale)
|
||||
|
||||
self.sv_addr = src_addr
|
||||
self.sv_linked = true
|
||||
|
||||
@@ -47,7 +47,23 @@ end
|
||||
-- initialize the coordinator IO controller
|
||||
---@param conf facility_conf configuration
|
||||
---@param comms coord_comms comms reference
|
||||
function iocontrol.init(conf, comms)
|
||||
---@param temp_scale integer temperature unit (1 = K, 2 = C, 3 = F, 4 = R)
|
||||
function iocontrol.init(conf, comms, temp_scale)
|
||||
-- temperature unit label and conversion function (from Kelvin)
|
||||
if temp_scale == 2 then
|
||||
io.temp_label = "\xb0C"
|
||||
io.temp_convert = function (t) return t - 273.15 end
|
||||
elseif temp_scale == 3 then
|
||||
io.temp_label = "\xb0F"
|
||||
io.temp_convert = function (t) return (1.8 * (t - 273.15)) + 32 end
|
||||
elseif temp_scale == 4 then
|
||||
io.temp_label = "\xb0R"
|
||||
io.temp_convert = function (t) return 1.8 * t end
|
||||
else
|
||||
io.temp_label = "K"
|
||||
io.temp_convert = function (t) return t end
|
||||
end
|
||||
|
||||
-- facility data structure
|
||||
---@class ioctl_facility
|
||||
io.facility = {
|
||||
@@ -110,9 +126,9 @@ function iocontrol.init(conf, comms)
|
||||
-- determine tank information
|
||||
if io.facility.tank_mode == 0 then
|
||||
io.facility.tank_defs = {}
|
||||
-- on facility tank mode 0, setup tank defs to match unit TANK option
|
||||
-- on facility tank mode 0, setup tank defs to match unit tank option
|
||||
for i = 1, conf.num_units do
|
||||
io.facility.tank_defs[i] = util.trinary(conf.cooling.r_cool[i].TANK, 1, 0)
|
||||
io.facility.tank_defs[i] = util.trinary(conf.cooling.r_cool[i].TankConnection, 1, 0)
|
||||
end
|
||||
|
||||
io.facility.tank_list = { table.unpack(io.facility.tank_defs) }
|
||||
@@ -214,12 +230,15 @@ function iocontrol.init(conf, comms)
|
||||
num_boilers = 0,
|
||||
num_turbines = 0,
|
||||
num_snas = 0,
|
||||
has_tank = conf.cooling.r_cool[i].TANK,
|
||||
has_tank = conf.cooling.r_cool[i].TankConnection,
|
||||
|
||||
control_state = false,
|
||||
burn_rate_cmd = 0.0,
|
||||
radiation = types.new_zero_radiation_reading(),
|
||||
sna_prod_rate = 0.0,
|
||||
|
||||
sna_peak_rate = 0.0,
|
||||
sna_max_rate = 0.0,
|
||||
sna_out_rate = 0.0,
|
||||
|
||||
waste_mode = types.WASTE_MODE.MANUAL_PLUTONIUM,
|
||||
waste_product = types.WASTE_PRODUCT.PLUTONIUM,
|
||||
@@ -295,13 +314,13 @@ function iocontrol.init(conf, comms)
|
||||
end
|
||||
|
||||
-- create boiler tables
|
||||
for _ = 1, conf.cooling.r_cool[i].BOILERS do
|
||||
for _ = 1, conf.cooling.r_cool[i].BoilerCount do
|
||||
table.insert(entry.boiler_ps_tbl, psil.create())
|
||||
table.insert(entry.boiler_data_tbl, {})
|
||||
end
|
||||
|
||||
-- create turbine tables
|
||||
for _ = 1, conf.cooling.r_cool[i].TURBINES do
|
||||
for _ = 1, conf.cooling.r_cool[i].TurbineCount do
|
||||
table.insert(entry.turbine_ps_tbl, psil.create())
|
||||
table.insert(entry.turbine_data_tbl, {})
|
||||
end
|
||||
@@ -923,7 +942,7 @@ function iocontrol.update_unit_statuses(statuses)
|
||||
local boil_sum = 0
|
||||
|
||||
for id = 1, #unit.boiler_ps_tbl do
|
||||
if rtu_statuses.boilers[i] == nil then
|
||||
if rtu_statuses.boilers[id] == nil then
|
||||
-- disconnected
|
||||
unit.boiler_ps_tbl[id].publish("computed_status", 1)
|
||||
end
|
||||
@@ -966,7 +985,7 @@ function iocontrol.update_unit_statuses(statuses)
|
||||
local flow_sum = 0
|
||||
|
||||
for id = 1, #unit.turbine_ps_tbl do
|
||||
if rtu_statuses.turbines[i] == nil then
|
||||
if rtu_statuses.turbines[id] == nil then
|
||||
-- disconnected
|
||||
unit.turbine_ps_tbl[id].publish("computed_status", 1)
|
||||
end
|
||||
@@ -1009,7 +1028,7 @@ function iocontrol.update_unit_statuses(statuses)
|
||||
-- dynamic tank statuses
|
||||
if type(rtu_statuses.tanks) == "table" then
|
||||
for id = 1, #unit.tank_ps_tbl do
|
||||
if rtu_statuses.tanks[i] == nil then
|
||||
if rtu_statuses.tanks[id] == nil then
|
||||
-- disconnected
|
||||
unit.tank_ps_tbl[id].publish("computed_status", 1)
|
||||
end
|
||||
@@ -1048,12 +1067,14 @@ function iocontrol.update_unit_statuses(statuses)
|
||||
-- solar neutron activator status info
|
||||
if type(rtu_statuses.sna) == "table" then
|
||||
unit.num_snas = rtu_statuses.sna[1] ---@type integer
|
||||
unit.sna_prod_rate = rtu_statuses.sna[2] ---@type number
|
||||
unit.sna_peak_rate = rtu_statuses.sna[3] ---@type number
|
||||
unit.sna_peak_rate = rtu_statuses.sna[2] ---@type number
|
||||
unit.sna_max_rate = rtu_statuses.sna[3] ---@type number
|
||||
unit.sna_out_rate = rtu_statuses.sna[4] ---@type number
|
||||
|
||||
unit.unit_ps.publish("sna_count", unit.num_snas)
|
||||
unit.unit_ps.publish("sna_prod_rate", unit.sna_prod_rate)
|
||||
unit.unit_ps.publish("sna_peak_rate", unit.sna_peak_rate)
|
||||
unit.unit_ps.publish("sna_max_rate", unit.sna_max_rate)
|
||||
unit.unit_ps.publish("sna_out_rate", unit.sna_out_rate)
|
||||
|
||||
sna_count_sum = sna_count_sum + unit.num_snas
|
||||
else
|
||||
@@ -1201,7 +1222,7 @@ function iocontrol.update_unit_statuses(statuses)
|
||||
|
||||
local u_spent_rate = waste_rate
|
||||
local u_pu_rate = util.trinary(is_pu, waste_rate, 0.0)
|
||||
local u_po_rate = util.trinary(not is_pu, math.min(waste_rate, unit.sna_prod_rate), 0.0)
|
||||
local u_po_rate = unit.sna_out_rate
|
||||
|
||||
unit.unit_ps.publish("pu_rate", u_pu_rate)
|
||||
unit.unit_ps.publish("po_rate", u_po_rate)
|
||||
@@ -1209,14 +1230,15 @@ function iocontrol.update_unit_statuses(statuses)
|
||||
unit.unit_ps.publish("sna_in", util.trinary(is_pu, 0, burn_rate))
|
||||
|
||||
if unit.waste_product == types.WASTE_PRODUCT.POLONIUM then
|
||||
u_spent_rate = u_po_rate
|
||||
unit.unit_ps.publish("po_pl_rate", u_po_rate)
|
||||
unit.unit_ps.publish("po_am_rate", 0)
|
||||
po_pl_rate = po_pl_rate + u_po_rate
|
||||
elseif unit.waste_product == types.WASTE_PRODUCT.ANTI_MATTER then
|
||||
u_spent_rate = 0
|
||||
unit.unit_ps.publish("po_pl_rate", 0)
|
||||
unit.unit_ps.publish("po_am_rate", u_po_rate)
|
||||
po_am_rate = po_am_rate + u_po_rate
|
||||
u_spent_rate = 0
|
||||
else
|
||||
unit.unit_ps.publish("po_pl_rate", 0)
|
||||
unit.unit_ps.publish("po_am_rate", 0)
|
||||
|
||||
@@ -19,15 +19,20 @@ local process = {}
|
||||
local self = {
|
||||
io = nil, ---@type ioctl
|
||||
comms = nil, ---@type coord_comms
|
||||
---@class coord_auto_config
|
||||
config = {
|
||||
mode = PROCESS.INACTIVE,
|
||||
burn_target = 0.0,
|
||||
charge_target = 0.0,
|
||||
gen_target = 0.0,
|
||||
limits = {},
|
||||
waste_product = PRODUCT.PLUTONIUM,
|
||||
pu_fallback = false
|
||||
---@class coord_control_states
|
||||
control_states = {
|
||||
---@class coord_auto_config
|
||||
process = {
|
||||
mode = PROCESS.INACTIVE,
|
||||
burn_target = 0.0,
|
||||
charge_target = 0.0,
|
||||
gen_target = 0.0,
|
||||
limits = {},
|
||||
waste_product = PRODUCT.PLUTONIUM,
|
||||
pu_fallback = false
|
||||
},
|
||||
waste_modes = {},
|
||||
priority_groups = {}
|
||||
}
|
||||
}
|
||||
|
||||
@@ -42,63 +47,64 @@ function process.init(iocontrol, coord_comms)
|
||||
self.io = iocontrol
|
||||
self.comms = coord_comms
|
||||
|
||||
local ctl_proc = self.control_states.process
|
||||
|
||||
for i = 1, self.io.facility.num_units do
|
||||
self.config.limits[i] = 0.1
|
||||
ctl_proc.limits[i] = 0.1
|
||||
end
|
||||
|
||||
-- load settings
|
||||
if not settings.load("/coord.settings") then
|
||||
log.error("process.init(): failed to load coordinator settings file")
|
||||
end
|
||||
local ctrl_states = settings.get("ControlStates", {})
|
||||
local config = ctrl_states.process ---@type coord_auto_config
|
||||
|
||||
-- facility auto control configuration
|
||||
local config = settings.get("PROCESS") ---@type coord_auto_config|nil
|
||||
if type(config) == "table" then
|
||||
self.config.mode = config.mode
|
||||
self.config.burn_target = config.burn_target
|
||||
self.config.charge_target = config.charge_target
|
||||
self.config.gen_target = config.gen_target
|
||||
self.config.limits = config.limits
|
||||
self.config.waste_product = config.waste_product
|
||||
self.config.pu_fallback = config.pu_fallback
|
||||
ctl_proc.mode = config.mode
|
||||
ctl_proc.burn_target = config.burn_target
|
||||
ctl_proc.charge_target = config.charge_target
|
||||
ctl_proc.gen_target = config.gen_target
|
||||
ctl_proc.limits = config.limits
|
||||
ctl_proc.waste_product = config.waste_product
|
||||
ctl_proc.pu_fallback = config.pu_fallback
|
||||
|
||||
self.io.facility.ps.publish("process_mode", self.config.mode)
|
||||
self.io.facility.ps.publish("process_burn_target", self.config.burn_target)
|
||||
self.io.facility.ps.publish("process_charge_target", self.config.charge_target)
|
||||
self.io.facility.ps.publish("process_gen_target", self.config.gen_target)
|
||||
self.io.facility.ps.publish("process_waste_product", self.config.waste_product)
|
||||
self.io.facility.ps.publish("process_pu_fallback", self.config.pu_fallback)
|
||||
self.io.facility.ps.publish("process_mode", ctl_proc.mode)
|
||||
self.io.facility.ps.publish("process_burn_target", ctl_proc.burn_target)
|
||||
self.io.facility.ps.publish("process_charge_target", ctl_proc.charge_target)
|
||||
self.io.facility.ps.publish("process_gen_target", ctl_proc.gen_target)
|
||||
self.io.facility.ps.publish("process_waste_product", ctl_proc.waste_product)
|
||||
self.io.facility.ps.publish("process_pu_fallback", ctl_proc.pu_fallback)
|
||||
|
||||
for id = 1, math.min(#self.config.limits, self.io.facility.num_units) do
|
||||
for id = 1, math.min(#ctl_proc.limits, self.io.facility.num_units) do
|
||||
local unit = self.io.units[id] ---@type ioctl_unit
|
||||
unit.unit_ps.publish("burn_limit", self.config.limits[id])
|
||||
unit.unit_ps.publish("burn_limit", ctl_proc.limits[id])
|
||||
end
|
||||
|
||||
log.info("PROCESS: loaded auto control settings from coord.settings")
|
||||
log.info("PROCESS: loaded auto control settings")
|
||||
|
||||
-- notify supervisor of auto waste config
|
||||
self.comms.send_fac_command(FAC_COMMAND.SET_WASTE_MODE, self.config.waste_product)
|
||||
self.comms.send_fac_command(FAC_COMMAND.SET_PU_FB, self.config.pu_fallback)
|
||||
self.comms.send_fac_command(FAC_COMMAND.SET_WASTE_MODE, ctl_proc.waste_product)
|
||||
self.comms.send_fac_command(FAC_COMMAND.SET_PU_FB, ctl_proc.pu_fallback)
|
||||
end
|
||||
|
||||
-- unit waste states
|
||||
local waste_modes = settings.get("WASTE_MODES") ---@type table|nil
|
||||
local waste_modes = ctrl_states.waste_modes ---@type table|nil
|
||||
if type(waste_modes) == "table" then
|
||||
for id, mode in pairs(waste_modes) do
|
||||
self.control_states.waste_modes[id] = mode
|
||||
self.comms.send_unit_command(UNIT_COMMAND.SET_WASTE, id, mode)
|
||||
end
|
||||
|
||||
log.info("PROCESS: loaded unit waste mode settings from coord.settings")
|
||||
log.info("PROCESS: loaded unit waste mode settings")
|
||||
end
|
||||
|
||||
-- unit priority groups
|
||||
local prio_groups = settings.get("PRIORITY_GROUPS") ---@type table|nil
|
||||
local prio_groups = ctrl_states.priority_groups ---@type table|nil
|
||||
if type(prio_groups) == "table" then
|
||||
for id, group in pairs(prio_groups) do
|
||||
self.control_states.priority_groups[id] = group
|
||||
self.comms.send_unit_command(UNIT_COMMAND.SET_GROUP, id, group)
|
||||
end
|
||||
|
||||
log.info("PROCESS: loaded priority groups settings from coord.settings")
|
||||
log.info("PROCESS: loaded priority groups settings")
|
||||
end
|
||||
end
|
||||
|
||||
@@ -155,15 +161,10 @@ function process.set_unit_waste(id, mode)
|
||||
self.comms.send_unit_command(UNIT_COMMAND.SET_WASTE, id, mode)
|
||||
log.debug(util.c("PROCESS: UNIT[", id, "] SET WASTE ", mode))
|
||||
|
||||
local waste_mode = settings.get("WASTE_MODES") ---@type table|nil
|
||||
self.control_states.waste_modes[id] = mode
|
||||
settings.set("ControlStates", self.control_states)
|
||||
|
||||
if type(waste_mode) ~= "table" then waste_mode = {} end
|
||||
|
||||
waste_mode[id] = mode
|
||||
|
||||
settings.set("WASTE_MODES", waste_mode)
|
||||
|
||||
if not settings.save("/coord.settings") then
|
||||
if not settings.save("/coordinator.settings") then
|
||||
log.error("process.set_unit_waste(): failed to save coordinator settings file")
|
||||
end
|
||||
end
|
||||
@@ -198,15 +199,10 @@ function process.set_group(unit_id, group_id)
|
||||
self.comms.send_unit_command(UNIT_COMMAND.SET_GROUP, unit_id, group_id)
|
||||
log.debug(util.c("PROCESS: UNIT[", unit_id, "] SET GROUP ", group_id))
|
||||
|
||||
local prio_groups = settings.get("PRIORITY_GROUPS") ---@type table|nil
|
||||
self.control_states.priority_groups[unit_id] = group_id
|
||||
settings.set("ControlStates", self.control_states)
|
||||
|
||||
if type(prio_groups) ~= "table" then prio_groups = {} end
|
||||
|
||||
prio_groups[unit_id] = group_id
|
||||
|
||||
settings.set("PRIORITY_GROUPS", prio_groups)
|
||||
|
||||
if not settings.save("/coord.settings") then
|
||||
if not settings.save("/coordinator.settings") then
|
||||
log.error("process.set_group(): failed to save coordinator settings file")
|
||||
end
|
||||
end
|
||||
@@ -217,20 +213,14 @@ end
|
||||
|
||||
-- write auto process control to config file
|
||||
local function _write_auto_config()
|
||||
-- attempt to load settings
|
||||
if not settings.load("/coord.settings") then
|
||||
log.warning("process._write_auto_config(): failed to load coordinator settings file")
|
||||
end
|
||||
|
||||
-- save config
|
||||
settings.set("PROCESS", self.config)
|
||||
local saved = settings.save("/coord.settings")
|
||||
|
||||
settings.set("ControlStates", self.control_states)
|
||||
local saved = settings.save("/coordinator.settings")
|
||||
if not saved then
|
||||
log.warning("process._write_auto_config(): failed to save coordinator settings file")
|
||||
end
|
||||
|
||||
return not not saved
|
||||
return saved
|
||||
end
|
||||
|
||||
-- stop automatic process control
|
||||
@@ -241,7 +231,7 @@ end
|
||||
|
||||
-- start automatic process control
|
||||
function process.start_auto()
|
||||
self.comms.send_auto_start(self.config)
|
||||
self.comms.send_auto_start(self.control_states.process)
|
||||
log.debug("PROCESS: START AUTO CTL")
|
||||
end
|
||||
|
||||
@@ -253,7 +243,7 @@ function process.set_process_waste(product)
|
||||
log.debug(util.c("PROCESS: SET WASTE ", product))
|
||||
|
||||
-- update config table and save
|
||||
self.config.waste_product = product
|
||||
self.control_states.process.waste_product = product
|
||||
_write_auto_config()
|
||||
end
|
||||
|
||||
@@ -265,7 +255,7 @@ function process.set_pu_fallback(enabled)
|
||||
log.debug(util.c("PROCESS: SET PU FALLBACK ", enabled))
|
||||
|
||||
-- update config table and save
|
||||
self.config.pu_fallback = enabled
|
||||
self.control_states.process.pu_fallback = enabled
|
||||
_write_auto_config()
|
||||
end
|
||||
|
||||
@@ -279,11 +269,12 @@ function process.save(mode, burn_target, charge_target, gen_target, limits)
|
||||
log.debug("PROCESS: SAVE")
|
||||
|
||||
-- update config table
|
||||
self.config.mode = mode
|
||||
self.config.burn_target = burn_target
|
||||
self.config.charge_target = charge_target
|
||||
self.config.gen_target = gen_target
|
||||
self.config.limits = limits
|
||||
local ctl_proc = self.control_states.process
|
||||
ctl_proc.mode = mode
|
||||
ctl_proc.burn_target = burn_target
|
||||
ctl_proc.charge_target = charge_target
|
||||
ctl_proc.gen_target = gen_target
|
||||
ctl_proc.limits = limits
|
||||
|
||||
-- save config
|
||||
self.io.facility.save_cfg_ack(_write_auto_config())
|
||||
@@ -294,22 +285,23 @@ end
|
||||
function process.start_ack_handle(response)
|
||||
local ack = response[1]
|
||||
|
||||
self.config.mode = response[2]
|
||||
self.config.burn_target = response[3]
|
||||
self.config.charge_target = response[4]
|
||||
self.config.gen_target = response[5]
|
||||
local ctl_proc = self.control_states.process
|
||||
ctl_proc.mode = response[2]
|
||||
ctl_proc.burn_target = response[3]
|
||||
ctl_proc.charge_target = response[4]
|
||||
ctl_proc.gen_target = response[5]
|
||||
|
||||
for i = 1, math.min(#response[6], self.io.facility.num_units) do
|
||||
self.config.limits[i] = response[6][i]
|
||||
ctl_proc.limits[i] = response[6][i]
|
||||
|
||||
local unit = self.io.units[i] ---@type ioctl_unit
|
||||
unit.unit_ps.publish("burn_limit", self.config.limits[i])
|
||||
unit.unit_ps.publish("burn_limit", ctl_proc.limits[i])
|
||||
end
|
||||
|
||||
self.io.facility.ps.publish("process_mode", self.config.mode)
|
||||
self.io.facility.ps.publish("process_burn_target", self.config.burn_target)
|
||||
self.io.facility.ps.publish("process_charge_target", self.config.charge_target)
|
||||
self.io.facility.ps.publish("process_gen_target", self.config.gen_target)
|
||||
self.io.facility.ps.publish("process_mode", ctl_proc.mode)
|
||||
self.io.facility.ps.publish("process_burn_target", ctl_proc.burn_target)
|
||||
self.io.facility.ps.publish("process_charge_target", ctl_proc.charge_target)
|
||||
self.io.facility.ps.publish("process_gen_target", ctl_proc.gen_target)
|
||||
|
||||
self.io.facility.start_ack(ack)
|
||||
end
|
||||
@@ -317,14 +309,14 @@ end
|
||||
-- record waste product state after attempting to change it
|
||||
---@param response WASTE_PRODUCT supervisor waste product state
|
||||
function process.waste_ack_handle(response)
|
||||
self.config.waste_product = response
|
||||
self.control_states.process.waste_product = response
|
||||
self.io.facility.ps.publish("process_waste_product", response)
|
||||
end
|
||||
|
||||
-- record plutonium fallback state after attempting to change it
|
||||
---@param response boolean supervisor plutonium fallback state
|
||||
function process.pu_fb_ack_handle(response)
|
||||
self.config.pu_fallback = response
|
||||
self.control_states.process.pu_fallback = response
|
||||
self.io.facility.ps.publish("process_pu_fallback", response)
|
||||
end
|
||||
|
||||
|
||||
@@ -3,7 +3,6 @@
|
||||
--
|
||||
|
||||
local log = require("scada-common.log")
|
||||
local util = require("scada-common.util")
|
||||
|
||||
local iocontrol = require("coordinator.iocontrol")
|
||||
|
||||
@@ -53,6 +52,16 @@ local function _init_display(monitor)
|
||||
end
|
||||
end
|
||||
|
||||
-- print out that the monitor is too small
|
||||
---@param monitor table monitor
|
||||
local function _print_too_small(monitor)
|
||||
monitor.setCursorPos(1, 1)
|
||||
monitor.setBackgroundColor(colors.black)
|
||||
monitor.setTextColor(colors.red)
|
||||
monitor.clear()
|
||||
monitor.write("monitor too small")
|
||||
end
|
||||
|
||||
-- disable the flow view
|
||||
---@param disable boolean
|
||||
function renderer.legacy_disable_flow_view(disable)
|
||||
@@ -65,15 +74,15 @@ function renderer.set_displays(monitors)
|
||||
engine.monitors = monitors
|
||||
|
||||
-- report to front panel as connected
|
||||
iocontrol.fp_monitor_state("main", engine.monitors.primary ~= nil)
|
||||
iocontrol.fp_monitor_state("main", engine.monitors.main ~= nil)
|
||||
iocontrol.fp_monitor_state("flow", engine.monitors.flow ~= nil)
|
||||
for i = 1, #engine.monitors.unit_displays do iocontrol.fp_monitor_state(i, true) end
|
||||
end
|
||||
|
||||
-- init all displays in use by the renderer
|
||||
function renderer.init_displays()
|
||||
-- init primary and flow monitors
|
||||
_init_display(engine.monitors.primary)
|
||||
-- init main and flow monitors
|
||||
_init_display(engine.monitors.main)
|
||||
if not engine.disable_flow_view then _init_display(engine.monitors.flow) end
|
||||
|
||||
-- init unit displays
|
||||
@@ -93,43 +102,10 @@ function renderer.init_displays()
|
||||
end
|
||||
end
|
||||
|
||||
-- check main display width
|
||||
---@nodiscard
|
||||
---@return boolean width_okay
|
||||
function renderer.validate_main_display_width()
|
||||
local w, _ = engine.monitors.primary.getSize()
|
||||
return w == 164
|
||||
end
|
||||
|
||||
-- check flow display width
|
||||
---@nodiscard
|
||||
---@return boolean width_okay
|
||||
function renderer.validate_flow_display_width()
|
||||
local w, _ = engine.monitors.flow.getSize()
|
||||
return w == 164
|
||||
end
|
||||
|
||||
-- check display sizes
|
||||
---@nodiscard
|
||||
---@return boolean valid all unit display dimensions OK
|
||||
function renderer.validate_unit_display_sizes()
|
||||
local valid = true
|
||||
|
||||
for id, monitor in ipairs(engine.monitors.unit_displays) do
|
||||
local w, h = monitor.getSize()
|
||||
if w ~= 79 or h ~= 52 then
|
||||
log.warning(util.c("RENDERER: unit ", id, " display resolution not 79 wide by 52 tall: ", w, ", ", h))
|
||||
valid = false
|
||||
end
|
||||
end
|
||||
|
||||
return valid
|
||||
end
|
||||
|
||||
-- initialize the dmesg output window
|
||||
function renderer.init_dmesg()
|
||||
local disp_x, disp_y = engine.monitors.primary.getSize()
|
||||
engine.dmesg_window = window.create(engine.monitors.primary, 1, 1, disp_x, disp_y)
|
||||
local disp_w, disp_h = engine.monitors.main.getSize()
|
||||
engine.dmesg_window = window.create(engine.monitors.main, 1, 1, disp_w, disp_h)
|
||||
log.direct_dmesg(engine.dmesg_window)
|
||||
end
|
||||
|
||||
@@ -200,8 +176,8 @@ function renderer.try_start_ui()
|
||||
|
||||
status, msg = pcall(function ()
|
||||
-- show main view on main monitor
|
||||
if engine.monitors.primary ~= nil then
|
||||
engine.ui.main_display = DisplayBox{window=engine.monitors.primary,fg_bg=style.root}
|
||||
if engine.monitors.main ~= nil then
|
||||
engine.ui.main_display = DisplayBox{window=engine.monitors.main,fg_bg=style.root}
|
||||
main_view(engine.ui.main_display)
|
||||
end
|
||||
|
||||
@@ -276,43 +252,43 @@ function renderer.ui_ready() return engine.ui_ready end
|
||||
function renderer.handle_disconnect(device)
|
||||
local is_used = false
|
||||
|
||||
if engine.monitors ~= nil then
|
||||
if engine.monitors.primary == device then
|
||||
if engine.ui.main_display ~= nil then
|
||||
-- delete element tree and clear root UI elements
|
||||
engine.ui.main_display.delete()
|
||||
end
|
||||
if not engine.monitors then return false end
|
||||
|
||||
is_used = true
|
||||
engine.monitors.primary = nil
|
||||
engine.ui.main_display = nil
|
||||
if engine.monitors.main == device then
|
||||
if engine.ui.main_display ~= nil then
|
||||
-- delete element tree and clear root UI elements
|
||||
engine.ui.main_display.delete()
|
||||
end
|
||||
|
||||
iocontrol.fp_monitor_state("main", false)
|
||||
elseif engine.monitors.flow == device then
|
||||
if engine.ui.flow_display ~= nil then
|
||||
-- delete element tree and clear root UI elements
|
||||
engine.ui.flow_display.delete()
|
||||
end
|
||||
is_used = true
|
||||
engine.monitors.main = nil
|
||||
engine.ui.main_display = nil
|
||||
|
||||
is_used = true
|
||||
engine.monitors.flow = nil
|
||||
engine.ui.flow_display = nil
|
||||
iocontrol.fp_monitor_state("main", false)
|
||||
elseif engine.monitors.flow == device then
|
||||
if engine.ui.flow_display ~= nil then
|
||||
-- delete element tree and clear root UI elements
|
||||
engine.ui.flow_display.delete()
|
||||
end
|
||||
|
||||
iocontrol.fp_monitor_state("flow", false)
|
||||
else
|
||||
for idx, monitor in pairs(engine.monitors.unit_displays) do
|
||||
if monitor == device then
|
||||
if engine.ui.unit_displays[idx] ~= nil then
|
||||
engine.ui.unit_displays[idx].delete()
|
||||
end
|
||||
is_used = true
|
||||
engine.monitors.flow = nil
|
||||
engine.ui.flow_display = nil
|
||||
|
||||
is_used = true
|
||||
engine.monitors.unit_displays[idx] = nil
|
||||
engine.ui.unit_displays[idx] = nil
|
||||
|
||||
iocontrol.fp_monitor_state(idx, false)
|
||||
break
|
||||
iocontrol.fp_monitor_state("flow", false)
|
||||
else
|
||||
for idx, monitor in pairs(engine.monitors.unit_displays) do
|
||||
if monitor == device then
|
||||
if engine.ui.unit_displays[idx] ~= nil then
|
||||
engine.ui.unit_displays[idx].delete()
|
||||
end
|
||||
|
||||
is_used = true
|
||||
engine.monitors.unit_displays[idx] = nil
|
||||
engine.ui.unit_displays[idx] = nil
|
||||
|
||||
iocontrol.fp_monitor_state(idx, false)
|
||||
break
|
||||
end
|
||||
end
|
||||
end
|
||||
@@ -327,52 +303,29 @@ end
|
||||
function renderer.handle_reconnect(name, device)
|
||||
local is_used = false
|
||||
|
||||
if engine.monitors ~= nil then
|
||||
if engine.monitors.primary_name == name then
|
||||
is_used = true
|
||||
_init_display(device)
|
||||
engine.monitors.primary = device
|
||||
if not engine.monitors then return false end
|
||||
|
||||
local disp_x, disp_y = engine.monitors.primary.getSize()
|
||||
engine.dmesg_window.reposition(1, 1, disp_x, disp_y, engine.monitors.primary)
|
||||
-- note: handle_resize is a more adaptive way of re-initializing a connected monitor
|
||||
-- since it can handle a monitor being reconnected that isn't the right size
|
||||
|
||||
if engine.ui_ready and (engine.ui.main_display == nil) then
|
||||
engine.dmesg_window.setVisible(false)
|
||||
if engine.monitors.main_name == name then
|
||||
is_used = true
|
||||
engine.monitors.main = device
|
||||
|
||||
engine.ui.main_display = DisplayBox{window=device,fg_bg=style.root}
|
||||
main_view(engine.ui.main_display)
|
||||
else
|
||||
engine.dmesg_window.setVisible(true)
|
||||
engine.dmesg_window.redraw()
|
||||
end
|
||||
renderer.handle_resize(name)
|
||||
elseif engine.monitors.flow_name == name then
|
||||
is_used = true
|
||||
engine.monitors.flow = device
|
||||
|
||||
iocontrol.fp_monitor_state("main", true)
|
||||
elseif engine.monitors.flow_name == name then
|
||||
is_used = true
|
||||
_init_display(device)
|
||||
engine.monitors.flow = device
|
||||
renderer.handle_resize(name)
|
||||
else
|
||||
for idx, monitor in ipairs(engine.monitors.unit_name_map) do
|
||||
if monitor == name then
|
||||
is_used = true
|
||||
engine.monitors.unit_displays[idx] = device
|
||||
|
||||
if engine.ui_ready and (engine.ui.flow_display == nil) then
|
||||
engine.ui.flow_display = DisplayBox{window=device,fg_bg=style.root}
|
||||
flow_view(engine.ui.flow_display)
|
||||
end
|
||||
|
||||
iocontrol.fp_monitor_state("flow", true)
|
||||
else
|
||||
for idx, monitor in ipairs(engine.monitors.unit_name_map) do
|
||||
if monitor == name then
|
||||
is_used = true
|
||||
_init_display(device)
|
||||
engine.monitors.unit_displays[idx] = device
|
||||
|
||||
if engine.ui_ready and (engine.ui.unit_displays[idx] == nil) then
|
||||
engine.ui.unit_displays[idx] = DisplayBox{window=device,fg_bg=style.root}
|
||||
unit_view(engine.ui.unit_displays[idx], idx)
|
||||
end
|
||||
|
||||
iocontrol.fp_monitor_state(idx, true)
|
||||
break
|
||||
end
|
||||
renderer.handle_resize(name)
|
||||
break
|
||||
end
|
||||
end
|
||||
end
|
||||
@@ -380,6 +333,137 @@ function renderer.handle_reconnect(name, device)
|
||||
return is_used
|
||||
end
|
||||
|
||||
-- handle a monitor being resized<br>
|
||||
-- returns if this monitor is assigned + if the assigned screen still fits
|
||||
---@param name string monitor name
|
||||
---@return boolean is_used, boolean is_ok
|
||||
function renderer.handle_resize(name)
|
||||
local is_used = false
|
||||
local is_ok = true
|
||||
local ui = engine.ui
|
||||
|
||||
if not engine.monitors then return false, false end
|
||||
|
||||
if engine.monitors.main_name == name and engine.monitors.main then
|
||||
local device = engine.monitors.main ---@type table
|
||||
|
||||
-- this is necessary if the bottom left block was broken and on reconnect
|
||||
_init_display(device)
|
||||
|
||||
is_used = true
|
||||
|
||||
-- resize dmesg window if needed, but don't make it thinner
|
||||
local disp_w, disp_h = engine.monitors.main.getSize()
|
||||
local dmsg_w, _ = engine.dmesg_window.getSize()
|
||||
engine.dmesg_window.reposition(1, 1, math.max(disp_w, dmsg_w), disp_h, engine.monitors.main)
|
||||
|
||||
if ui.main_display then
|
||||
ui.main_display.delete()
|
||||
ui.main_display = nil
|
||||
end
|
||||
|
||||
iocontrol.fp_monitor_state("main", true)
|
||||
|
||||
engine.dmesg_window.setVisible(not engine.ui_ready)
|
||||
|
||||
if engine.ui_ready then
|
||||
local ok = pcall(function ()
|
||||
ui.main_display = DisplayBox{window=device,fg_bg=style.root}
|
||||
main_view(ui.main_display)
|
||||
end)
|
||||
|
||||
if not ok then
|
||||
if ui.main_display then
|
||||
ui.main_display.delete()
|
||||
ui.main_display = nil
|
||||
end
|
||||
|
||||
_print_too_small(device)
|
||||
|
||||
iocontrol.fp_monitor_state("main", false)
|
||||
is_ok = false
|
||||
end
|
||||
else engine.dmesg_window.redraw() end
|
||||
elseif engine.monitors.flow_name == name and engine.monitors.flow then
|
||||
local device = engine.monitors.flow ---@type table
|
||||
|
||||
-- this is necessary if the bottom left block was broken and on reconnect
|
||||
_init_display(device)
|
||||
|
||||
is_used = true
|
||||
|
||||
if ui.flow_display then
|
||||
ui.flow_display.delete()
|
||||
ui.flow_display = nil
|
||||
end
|
||||
|
||||
iocontrol.fp_monitor_state("flow", true)
|
||||
|
||||
if engine.ui_ready then
|
||||
engine.dmesg_window.setVisible(false)
|
||||
|
||||
local ok = pcall(function ()
|
||||
ui.flow_display = DisplayBox{window=device,fg_bg=style.root}
|
||||
flow_view(ui.flow_display)
|
||||
end)
|
||||
|
||||
if not ok then
|
||||
if ui.flow_display then
|
||||
ui.flow_display.delete()
|
||||
ui.flow_display = nil
|
||||
end
|
||||
|
||||
_print_too_small(device)
|
||||
|
||||
iocontrol.fp_monitor_state("flow", false)
|
||||
is_ok = false
|
||||
end
|
||||
end
|
||||
else
|
||||
for idx, monitor in ipairs(engine.monitors.unit_name_map) do
|
||||
local device = engine.monitors.unit_displays[idx]
|
||||
|
||||
if monitor == name and device then
|
||||
-- this is necessary if the bottom left block was broken and on reconnect
|
||||
_init_display(device)
|
||||
|
||||
is_used = true
|
||||
|
||||
if ui.unit_displays[idx] then
|
||||
ui.unit_displays[idx].delete()
|
||||
ui.unit_displays[idx] = nil
|
||||
end
|
||||
|
||||
iocontrol.fp_monitor_state(idx, true)
|
||||
|
||||
if engine.ui_ready then
|
||||
engine.dmesg_window.setVisible(false)
|
||||
|
||||
local ok = pcall(function ()
|
||||
ui.unit_displays[idx] = DisplayBox{window=device,fg_bg=style.root}
|
||||
unit_view(ui.unit_displays[idx], idx)
|
||||
end)
|
||||
|
||||
if not ok then
|
||||
if ui.unit_displays[idx] then
|
||||
ui.unit_displays[idx].delete()
|
||||
ui.unit_displays[idx] = nil
|
||||
end
|
||||
|
||||
_print_too_small(device)
|
||||
|
||||
iocontrol.fp_monitor_state(idx, false)
|
||||
is_ok = false
|
||||
end
|
||||
end
|
||||
|
||||
break
|
||||
end
|
||||
end
|
||||
end
|
||||
|
||||
return is_used, is_ok
|
||||
end
|
||||
|
||||
-- handle a touch event
|
||||
---@param event mouse_interaction|nil
|
||||
@@ -388,16 +472,15 @@ function renderer.handle_mouse(event)
|
||||
if engine.fp_ready and event.monitor == "terminal" then
|
||||
engine.ui.front_panel.handle_mouse(event)
|
||||
elseif engine.ui_ready then
|
||||
if event.monitor == engine.monitors.primary_name then
|
||||
engine.ui.main_display.handle_mouse(event)
|
||||
if event.monitor == engine.monitors.main_name then
|
||||
if engine.ui.main_display then engine.ui.main_display.handle_mouse(event) end
|
||||
elseif event.monitor == engine.monitors.flow_name then
|
||||
engine.ui.flow_display.handle_mouse(event)
|
||||
if engine.ui.flow_display then engine.ui.flow_display.handle_mouse(event) end
|
||||
else
|
||||
for id, monitor in ipairs(engine.monitors.unit_name_map) do
|
||||
if event.monitor == monitor then
|
||||
local layout = engine.ui.unit_displays[id] ---@type graphics_element
|
||||
layout.handle_mouse(event)
|
||||
break
|
||||
local display = engine.ui.unit_displays[id]
|
||||
if event.monitor == monitor and display then
|
||||
if display then display.handle_mouse(event) end
|
||||
end
|
||||
end
|
||||
end
|
||||
|
||||
@@ -3,7 +3,6 @@ local log = require("scada-common.log")
|
||||
local mqueue = require("scada-common.mqueue")
|
||||
local util = require("scada-common.util")
|
||||
|
||||
local config = require("coordinator.config")
|
||||
local iocontrol = require("coordinator.iocontrol")
|
||||
|
||||
local pocket = require("coordinator.session.pocket")
|
||||
@@ -11,7 +10,8 @@ local pocket = require("coordinator.session.pocket")
|
||||
local apisessions = {}
|
||||
|
||||
local self = {
|
||||
nic = nil,
|
||||
nic = nil, ---@type nic
|
||||
config = nil, ---@type crd_config
|
||||
next_id = 0,
|
||||
sessions = {}
|
||||
}
|
||||
@@ -32,7 +32,7 @@ local function _api_handle_outq(session)
|
||||
if msg ~= nil then
|
||||
if msg.qtype == mqueue.TYPE.PACKET then
|
||||
-- handle a packet to be sent
|
||||
self.nic.transmit(config.PKT_CHANNEL, config.CRD_CHANNEL, msg.message)
|
||||
self.nic.transmit(self.config.PKT_Channel, self.config.CRD_Channel, msg.message)
|
||||
elseif msg.qtype == mqueue.TYPE.COMMAND then
|
||||
-- handle instruction/notification
|
||||
elseif msg.qtype == mqueue.TYPE.DATA then
|
||||
@@ -59,7 +59,7 @@ local function _shutdown(session)
|
||||
while session.out_queue.ready() do
|
||||
local msg = session.out_queue.pop()
|
||||
if msg ~= nil and msg.qtype == mqueue.TYPE.PACKET then
|
||||
self.nic.transmit(config.PKT_CHANNEL, config.CRD_CHANNEL, msg.message)
|
||||
self.nic.transmit(self.config.PKT_Channel, self.config.CRD_Channel, msg.message)
|
||||
end
|
||||
end
|
||||
|
||||
@@ -69,9 +69,11 @@ end
|
||||
-- PUBLIC FUNCTIONS --
|
||||
|
||||
-- initialize apisessions
|
||||
---@param nic nic
|
||||
function apisessions.init(nic)
|
||||
---@param nic nic network interface
|
||||
---@param config crd_config coordinator config
|
||||
function apisessions.init(nic, config)
|
||||
self.nic = nic
|
||||
self.config = config
|
||||
end
|
||||
|
||||
-- find a session by remote port
|
||||
@@ -103,7 +105,7 @@ function apisessions.establish_session(source_addr, version)
|
||||
|
||||
local id = self.next_id
|
||||
|
||||
pkt_s.instance = pocket.new_session(id, source_addr, pkt_s.in_queue, pkt_s.out_queue, config.API_TIMEOUT)
|
||||
pkt_s.instance = pocket.new_session(id, source_addr, pkt_s.in_queue, pkt_s.out_queue, self.config.API_Timeout)
|
||||
table.insert(self.sessions, pkt_s)
|
||||
|
||||
local mt = {
|
||||
|
||||
@@ -14,7 +14,7 @@ local util = require("scada-common.util")
|
||||
|
||||
local core = require("graphics.core")
|
||||
|
||||
local config = require("coordinator.config")
|
||||
local configure = require("coordinator.configure")
|
||||
local coordinator = require("coordinator.coordinator")
|
||||
local iocontrol = require("coordinator.iocontrol")
|
||||
local renderer = require("coordinator.renderer")
|
||||
@@ -22,7 +22,9 @@ local sounder = require("coordinator.sounder")
|
||||
|
||||
local apisessions = require("coordinator.session.apisessions")
|
||||
|
||||
local COORDINATOR_VERSION = "v1.0.17"
|
||||
local COORDINATOR_VERSION = "v1.2.11"
|
||||
|
||||
local CHUNK_LOAD_DELAY_S = 30.0
|
||||
|
||||
local println = util.println
|
||||
local println_ts = util.println_ts
|
||||
@@ -34,32 +36,66 @@ local log_comms = coordinator.log_comms
|
||||
local log_crypto = coordinator.log_crypto
|
||||
|
||||
----------------------------------------
|
||||
-- config validation
|
||||
-- get configuration
|
||||
----------------------------------------
|
||||
|
||||
local cfv = util.new_validator()
|
||||
-- mount connected devices (required for monitor setup)
|
||||
ppm.mount_all()
|
||||
|
||||
cfv.assert_channel(config.SVR_CHANNEL)
|
||||
cfv.assert_channel(config.CRD_CHANNEL)
|
||||
cfv.assert_channel(config.PKT_CHANNEL)
|
||||
cfv.assert_type_int(config.TRUSTED_RANGE)
|
||||
cfv.assert_type_num(config.SV_TIMEOUT)
|
||||
cfv.assert_min(config.SV_TIMEOUT, 2)
|
||||
cfv.assert_type_num(config.API_TIMEOUT)
|
||||
cfv.assert_min(config.API_TIMEOUT, 2)
|
||||
cfv.assert_type_int(config.NUM_UNITS)
|
||||
cfv.assert_type_num(config.SOUNDER_VOLUME)
|
||||
cfv.assert_type_bool(config.TIME_24_HOUR)
|
||||
cfv.assert_type_str(config.LOG_PATH)
|
||||
cfv.assert_type_int(config.LOG_MODE)
|
||||
local wait_on_load = true
|
||||
local loaded, monitors = coordinator.load_config()
|
||||
|
||||
assert(cfv.valid(), "bad config file: missing/invalid fields")
|
||||
-- if the computer just started, its chunk may have just loaded (...or the user rebooted)
|
||||
-- if monitor config failed, maybe an adjacent chunk containing all or part of a monitor has not loaded yet, so keep trying
|
||||
while wait_on_load and loaded == 2 and os.clock() < CHUNK_LOAD_DELAY_S do
|
||||
term.clear()
|
||||
term.setCursorPos(1, 1)
|
||||
println("There was a monitor configuration problem at boot.\n")
|
||||
println("Startup will keep trying every 2s in case of chunk load delays.\n")
|
||||
println(util.sprintf("The configurator will be started in %ds if all attempts fail.\n", math.max(0, CHUNK_LOAD_DELAY_S - os.clock())))
|
||||
println("(click to skip to the configurator)")
|
||||
|
||||
local timer_id = util.start_timer(2)
|
||||
|
||||
while true do
|
||||
local event, param1 = util.pull_event()
|
||||
if event == "timer" and param1 == timer_id then
|
||||
-- remount and re-attempt
|
||||
ppm.mount_all()
|
||||
loaded, monitors = coordinator.load_config()
|
||||
break
|
||||
elseif event == "mouse_click" or event == "terminate" then
|
||||
wait_on_load = false
|
||||
break
|
||||
end
|
||||
end
|
||||
end
|
||||
|
||||
if loaded ~= 0 then
|
||||
-- try to reconfigure (user action)
|
||||
local success, error = configure.configure(loaded, monitors)
|
||||
if success then
|
||||
loaded, monitors = coordinator.load_config()
|
||||
if loaded ~= 0 then
|
||||
println(util.trinary(loaded == 2, "monitor configuration invalid", "failed to load a valid configuration") .. ", please reconfigure")
|
||||
return
|
||||
end
|
||||
else
|
||||
println("configuration error: " .. error)
|
||||
return
|
||||
end
|
||||
end
|
||||
|
||||
-- passed checks, good now
|
||||
---@cast monitors monitors_struct
|
||||
|
||||
local config = coordinator.config
|
||||
|
||||
----------------------------------------
|
||||
-- log init
|
||||
----------------------------------------
|
||||
|
||||
log.init(config.LOG_PATH, config.LOG_MODE, config.LOG_DEBUG == true)
|
||||
log.init(config.LogPath, config.LogMode, config.LogDebug)
|
||||
|
||||
log.info("========================================")
|
||||
log.info("BOOTING coordinator.startup " .. COORDINATOR_VERSION)
|
||||
@@ -77,39 +113,16 @@ local function main()
|
||||
-- system startup
|
||||
----------------------------------------
|
||||
|
||||
-- mount connected devices
|
||||
ppm.mount_all()
|
||||
-- log mounts now since mounting was done before logging was ready
|
||||
ppm.log_mounts()
|
||||
|
||||
-- report versions/init fp PSIL
|
||||
iocontrol.init_fp(COORDINATOR_VERSION, comms.version)
|
||||
|
||||
-- setup monitors
|
||||
local configured, monitors = coordinator.configure_monitors(config.NUM_UNITS, config.DISABLE_FLOW_VIEW == true)
|
||||
if not configured or monitors == nil then
|
||||
println("startup> monitor setup failed")
|
||||
log.fatal("monitor configuration failed")
|
||||
return
|
||||
end
|
||||
|
||||
-- init renderer
|
||||
renderer.legacy_disable_flow_view(config.DISABLE_FLOW_VIEW == true)
|
||||
renderer.legacy_disable_flow_view(config.DisableFlowView)
|
||||
renderer.set_displays(monitors)
|
||||
renderer.init_displays()
|
||||
|
||||
if not renderer.validate_main_display_width() then
|
||||
println("startup> main display must be 8 blocks wide")
|
||||
log.fatal("main display not wide enough")
|
||||
return
|
||||
elseif (config.DISABLE_FLOW_VIEW ~= true) and not renderer.validate_flow_display_width() then
|
||||
println("startup> flow display must be 8 blocks wide")
|
||||
log.fatal("flow display not wide enough")
|
||||
return
|
||||
elseif not renderer.validate_unit_display_sizes() then
|
||||
println("startup> one or more unit display dimensions incorrect; they must be 4x4 blocks")
|
||||
log.fatal("unit display dimensions incorrect")
|
||||
return
|
||||
end
|
||||
|
||||
renderer.init_dmesg()
|
||||
|
||||
-- lets get started!
|
||||
@@ -132,7 +145,7 @@ local function main()
|
||||
else
|
||||
local sounder_start = util.time_ms()
|
||||
log_boot("annunciator alarm speaker connected")
|
||||
sounder.init(speaker, config.SOUNDER_VOLUME)
|
||||
sounder.init(speaker, config.SpeakerVolume)
|
||||
log_boot("tone generation took " .. (util.time_ms() - sounder_start) .. "ms")
|
||||
log_sys("annunciator alarm configured")
|
||||
iocontrol.fp_has_speaker(true)
|
||||
@@ -143,8 +156,8 @@ local function main()
|
||||
----------------------------------------
|
||||
|
||||
-- message authentication init
|
||||
if type(config.AUTH_KEY) == "string" then
|
||||
local init_time = network.init_mac(config.AUTH_KEY)
|
||||
if type(config.AuthKey) == "string" and string.len(config.AuthKey) > 0 then
|
||||
local init_time = network.init_mac(config.AuthKey)
|
||||
log_crypto("HMAC init took " .. init_time .. "ms")
|
||||
end
|
||||
|
||||
@@ -161,14 +174,13 @@ local function main()
|
||||
end
|
||||
|
||||
-- create connection watchdog
|
||||
local conn_watchdog = util.new_watchdog(config.SV_TIMEOUT)
|
||||
local conn_watchdog = util.new_watchdog(config.SVR_Timeout)
|
||||
conn_watchdog.cancel()
|
||||
log.debug("startup> conn watchdog created")
|
||||
|
||||
-- create network interface then setup comms
|
||||
local nic = network.nic(modem)
|
||||
local coord_comms = coordinator.comms(COORDINATOR_VERSION, nic, config.NUM_UNITS, config.CRD_CHANNEL,
|
||||
config.SVR_CHANNEL, config.PKT_CHANNEL, config.TRUSTED_RANGE, conn_watchdog)
|
||||
local coord_comms = coordinator.comms(COORDINATOR_VERSION, nic, conn_watchdog)
|
||||
log.debug("startup> comms init")
|
||||
log_comms("comms initialized")
|
||||
|
||||
@@ -214,7 +226,7 @@ local function main()
|
||||
|
||||
local link_failed = false
|
||||
local ui_ok = true
|
||||
local date_format = util.trinary(config.TIME_24_HOUR, "%X \x04 %A, %B %d %Y", "%r \x04 %A, %B %d %Y")
|
||||
local date_format = util.trinary(config.Time24Hour, "%X \x04 %A, %B %d %Y", "%r \x04 %A, %B %d %Y")
|
||||
|
||||
-- start clock
|
||||
loop_clock.start()
|
||||
@@ -291,6 +303,11 @@ local function main()
|
||||
iocontrol.fp_has_speaker(true)
|
||||
end
|
||||
end
|
||||
elseif event == "monitor_resize" then
|
||||
local is_used, is_ok = renderer.handle_resize(param1)
|
||||
if is_used then
|
||||
log_sys(util.c("configured monitor ", param1, " resized, ", util.trinary(is_ok, "display still fits", "display no longer fits")))
|
||||
end
|
||||
elseif event == "timer" then
|
||||
if loop_clock.is_clock(param1) then
|
||||
-- main loop tick
|
||||
|
||||
@@ -1,5 +1,7 @@
|
||||
local style = require("coordinator.ui.style")
|
||||
|
||||
local iocontrol = require("coordinator.iocontrol")
|
||||
|
||||
local core = require("graphics.core")
|
||||
|
||||
local Rectangle = require("graphics.elements.rectangle")
|
||||
@@ -13,6 +15,7 @@ local cpair = core.cpair
|
||||
local border = core.border
|
||||
|
||||
local text_fg_bg = style.text_colors
|
||||
local lu_col = style.lu_colors
|
||||
|
||||
-- new boiler view
|
||||
---@param root graphics_element parent
|
||||
@@ -20,14 +23,16 @@ local text_fg_bg = style.text_colors
|
||||
---@param y integer top left y
|
||||
---@param ps psil ps interface
|
||||
local function new_view(root, x, y, ps)
|
||||
local db = iocontrol.get_db()
|
||||
|
||||
local boiler = Rectangle{parent=root,border=border(1,colors.gray,true),width=31,height=7,x=x,y=y}
|
||||
|
||||
local status = StateIndicator{parent=boiler,x=9,y=1,states=style.boiler.states,value=1,min_width=12}
|
||||
local temp = DataIndicator{parent=boiler,x=5,y=3,lu_colors=style.lu_col,label="Temp:",unit="K",format="%10.2f",value=0,width=22,fg_bg=text_fg_bg}
|
||||
local boil_r = DataIndicator{parent=boiler,x=5,y=4,lu_colors=style.lu_col,label="Boil:",unit="mB/t",format="%10.0f",value=0,commas=true,width=22,fg_bg=text_fg_bg}
|
||||
local temp = DataIndicator{parent=boiler,x=5,y=3,lu_colors=lu_col,label="Temp:",unit=db.temp_label,format="%10.2f",value=0,commas=true,width=22,fg_bg=text_fg_bg}
|
||||
local boil_r = DataIndicator{parent=boiler,x=5,y=4,lu_colors=lu_col,label="Boil:",unit="mB/t",format="%10.0f",value=0,commas=true,width=22,fg_bg=text_fg_bg}
|
||||
|
||||
status.register(ps, "computed_status", status.update)
|
||||
temp.register(ps, "temperature", temp.update)
|
||||
temp.register(ps, "temperature", function (t) temp.update(db.temp_convert(t)) end)
|
||||
boil_r.register(ps, "boil_rate", boil_r.update)
|
||||
|
||||
TextBox{parent=boiler,text="H",x=2,y=5,height=1,width=1,fg_bg=text_fg_bg}
|
||||
|
||||
@@ -1,5 +1,7 @@
|
||||
local types = require("scada-common.types")
|
||||
|
||||
local iocontrol = require("coordinator.iocontrol")
|
||||
|
||||
local style = require("coordinator.ui.style")
|
||||
|
||||
local core = require("graphics.core")
|
||||
@@ -23,15 +25,17 @@ local lu_col = style.lu_colors
|
||||
---@param y integer top left y
|
||||
---@param ps psil ps interface
|
||||
local function new_view(root, x, y, ps)
|
||||
local db = iocontrol.get_db()
|
||||
|
||||
local reactor = Rectangle{parent=root,border=border(1, colors.gray, true),width=30,height=7,x=x,y=y}
|
||||
|
||||
local status = StateIndicator{parent=reactor,x=6,y=1,states=style.reactor.states,value=1,min_width=16}
|
||||
local core_temp = DataIndicator{parent=reactor,x=2,y=3,lu_colors=lu_col,label="Core Temp:",unit="K",format="%10.2f",value=0,width=26,fg_bg=text_fg_bg}
|
||||
local core_temp = DataIndicator{parent=reactor,x=2,y=3,lu_colors=lu_col,label="Core Temp:",unit=db.temp_label,format="%10.2f",value=0,commas=true,width=26,fg_bg=text_fg_bg}
|
||||
local burn_r = DataIndicator{parent=reactor,x=2,y=4,lu_colors=lu_col,label="Burn Rate:",unit="mB/t",format="%10.2f",value=0,width=26,fg_bg=text_fg_bg}
|
||||
local heating_r = DataIndicator{parent=reactor,x=2,y=5,lu_colors=lu_col,label="Heating:",unit="mB/t",format="%12.0f",value=0,commas=true,width=26,fg_bg=text_fg_bg}
|
||||
|
||||
status.register(ps, "computed_status", status.update)
|
||||
core_temp.register(ps, "temp", core_temp.update)
|
||||
core_temp.register(ps, "temp", function (t) core_temp.update(db.temp_convert(t)) end)
|
||||
burn_r.register(ps, "act_burn_rate", burn_r.update)
|
||||
heating_r.register(ps, "heating_rate", heating_r.update)
|
||||
|
||||
|
||||
@@ -3,6 +3,7 @@
|
||||
--
|
||||
|
||||
local types = require("scada-common.types")
|
||||
local util = require("scada-common.util")
|
||||
|
||||
local iocontrol = require("coordinator.iocontrol")
|
||||
|
||||
@@ -51,8 +52,9 @@ local period = core.flasher.PERIOD
|
||||
---@param parent graphics_element parent
|
||||
---@param id integer
|
||||
local function init(parent, id)
|
||||
local unit = iocontrol.get_db().units[id] ---@type ioctl_unit
|
||||
local f_ps = iocontrol.get_db().facility.ps
|
||||
local db = iocontrol.get_db()
|
||||
local unit = db.units[id] ---@type ioctl_unit
|
||||
local f_ps = db.facility.ps
|
||||
|
||||
local main = Div{parent=parent,x=1,y=1}
|
||||
|
||||
@@ -114,8 +116,9 @@ local function init(parent, id)
|
||||
end)
|
||||
|
||||
TextBox{parent=main,x=32,y=22,text="Core Temp",height=1,width=9,fg_bg=style.label}
|
||||
local core_temp = DataIndicator{parent=main,x=32,label="",format="%11.2f",value=0,unit="K",lu_colors=lu_cpair,width=13,fg_bg=bw_fg_bg}
|
||||
core_temp.register(u_ps, "temp", core_temp.update)
|
||||
local fmt = util.trinary(string.len(db.temp_label) == 2, "%10.2f", "%11.2f")
|
||||
local core_temp = DataIndicator{parent=main,x=32,label="",format=fmt,value=0,commas=true,unit=db.temp_label,lu_colors=lu_cpair,width=13,fg_bg=bw_fg_bg}
|
||||
core_temp.register(u_ps, "temp", function (t) core_temp.update(db.temp_convert(t)) end)
|
||||
|
||||
TextBox{parent=main,x=32,y=25,text="Burn Rate",height=1,width=9,fg_bg=style.label}
|
||||
local act_burn_r = DataIndicator{parent=main,x=32,label="",format="%8.2f",value=0,unit="mB/t",lu_colors=lu_cpair,width=13,fg_bg=bw_fg_bg}
|
||||
@@ -257,7 +260,7 @@ local function init(parent, id)
|
||||
if unit.num_boilers > 0 then
|
||||
TextBox{parent=rcs_tags,x=1,text="B1",width=2,height=1,fg_bg=bw_fg_bg}
|
||||
local b1_wll = IndicatorLight{parent=rcs_annunc,label="Water Level Low",colors=ind_red}
|
||||
b1_wll.register(b_ps[1], "WasterLevelLow", b1_wll.update)
|
||||
b1_wll.register(b_ps[1], "WaterLevelLow", b1_wll.update)
|
||||
|
||||
TextBox{parent=rcs_tags,text="B1",width=2,height=1,fg_bg=bw_fg_bg}
|
||||
local b1_hr = IndicatorLight{parent=rcs_annunc,label="Heating Rate Low",colors=ind_yel}
|
||||
@@ -273,7 +276,7 @@ local function init(parent, id)
|
||||
|
||||
TextBox{parent=rcs_tags,text="B2",width=2,height=1,fg_bg=bw_fg_bg}
|
||||
local b2_wll = IndicatorLight{parent=rcs_annunc,label="Water Level Low",colors=ind_red}
|
||||
b2_wll.register(b_ps[2], "WasterLevelLow", b2_wll.update)
|
||||
b2_wll.register(b_ps[2], "WaterLevelLow", b2_wll.update)
|
||||
|
||||
TextBox{parent=rcs_tags,text="B2",width=2,height=1,fg_bg=bw_fg_bg}
|
||||
local b2_hr = IndicatorLight{parent=rcs_annunc,label="Heating Rate Low",colors=ind_yel}
|
||||
|
||||
@@ -181,10 +181,10 @@ local function make(parent, x, y, wide, unit)
|
||||
|
||||
local waste_rate = DataIndicator{parent=waste,x=1,y=3,lu_colors=lu_c,label="",unit="mB/t",format="%7.2f",value=0,width=12,fg_bg=bw_fg_bg}
|
||||
local pu_rate = DataIndicator{parent=waste,x=_wide(82,70),y=3,lu_colors=lu_c,label="",unit="mB/t",format="%7.3f",value=0,width=12,fg_bg=bw_fg_bg}
|
||||
local po_rate = DataIndicator{parent=waste,x=_wide(52,45),y=6,lu_colors=lu_c,label="",unit="mB/t",format="%7.3f",value=0,width=12,fg_bg=bw_fg_bg}
|
||||
local popl_rate = DataIndicator{parent=waste,x=_wide(82,70),y=6,lu_colors=lu_c,label="",unit="mB/t",format="%7.3f",value=0,width=12,fg_bg=bw_fg_bg}
|
||||
local poam_rate = DataIndicator{parent=waste,x=_wide(82,70),y=10,lu_colors=lu_c,label="",unit="mB/t",format="%7.3f",value=0,width=12,fg_bg=bw_fg_bg}
|
||||
local spent_rate = DataIndicator{parent=waste,x=_wide(117,99),y=3,lu_colors=lu_c,label="",unit="mB/t",format="%7.3f",value=0,width=12,fg_bg=bw_fg_bg}
|
||||
local po_rate = DataIndicator{parent=waste,x=_wide(52,45),y=6,lu_colors=lu_c,label="",unit="mB/t",format="%7.2f",value=0,width=12,fg_bg=bw_fg_bg}
|
||||
local popl_rate = DataIndicator{parent=waste,x=_wide(82,70),y=6,lu_colors=lu_c,label="",unit="mB/t",format="%7.2f",value=0,width=12,fg_bg=bw_fg_bg}
|
||||
local poam_rate = DataIndicator{parent=waste,x=_wide(82,70),y=10,lu_colors=lu_c,label="",unit="mB/t",format="%7.2f",value=0,width=12,fg_bg=bw_fg_bg}
|
||||
local spent_rate = DataIndicator{parent=waste,x=_wide(117,98),y=3,lu_colors=lu_c,label="",unit="mB/t",format="%8.3f",value=0,width=13,fg_bg=bw_fg_bg}
|
||||
|
||||
waste_rate.register(unit.unit_ps, "act_burn_rate", waste_rate.update)
|
||||
pu_rate.register(unit.unit_ps, "pu_rate", pu_rate.update)
|
||||
@@ -214,7 +214,7 @@ local function make(parent, x, y, wide, unit)
|
||||
sna_act.register(unit.unit_ps, "po_rate", function (r) sna_act.update(r > 0) end)
|
||||
sna_cnt.register(unit.unit_ps, "sna_count", sna_cnt.update)
|
||||
sna_pk.register(unit.unit_ps, "sna_peak_rate", sna_pk.update)
|
||||
sna_max.register(unit.unit_ps, "sna_prod_rate", sna_max.update)
|
||||
sna_max.register(unit.unit_ps, "sna_max_rate", sna_max.update)
|
||||
sna_in.register(unit.unit_ps, "sna_in", sna_in.update)
|
||||
|
||||
return root
|
||||
|
||||
@@ -1,52 +0,0 @@
|
||||
local completion = require("cc.completion")
|
||||
|
||||
local util = require("scada-common.util")
|
||||
|
||||
local print = util.print
|
||||
|
||||
local dialog = {}
|
||||
|
||||
-- ask the user yes or no
|
||||
---@nodiscard
|
||||
---@param question string
|
||||
---@param default boolean
|
||||
---@return boolean|nil
|
||||
function dialog.ask_y_n(question, default)
|
||||
print(question)
|
||||
|
||||
if default == true then
|
||||
print(" (Y/n)? ")
|
||||
else
|
||||
print(" (y/N)? ")
|
||||
end
|
||||
|
||||
local response = read(nil, nil)
|
||||
|
||||
if response == "" then
|
||||
return default
|
||||
elseif response == "Y" or response == "y" then
|
||||
return true
|
||||
elseif response == "N" or response == "n" then
|
||||
return false
|
||||
else
|
||||
return nil
|
||||
end
|
||||
end
|
||||
|
||||
-- ask the user for an input within a set of options
|
||||
---@nodiscard
|
||||
---@param options table
|
||||
---@param cancel string
|
||||
---@return boolean|string|nil
|
||||
function dialog.ask_options(options, cancel)
|
||||
print("> ")
|
||||
local response = read(nil, nil, function(text) return completion.choice(text, options) end)
|
||||
|
||||
if response == cancel then return false end
|
||||
|
||||
if util.table_contains(options, response) then
|
||||
return response
|
||||
else return nil end
|
||||
end
|
||||
|
||||
return dialog
|
||||
@@ -348,7 +348,7 @@ local function init(main)
|
||||
status.register(facility.sps_ps_tbl[1], "computed_status", status.update)
|
||||
|
||||
TextBox{parent=sps_box,x=2,y=3,text="Input Rate",height=1,width=10,fg_bg=style.label}
|
||||
local sps_in = DataIndicator{parent=sps_box,x=2,label="",format="%15.3f",value=0,unit="mB/t",lu_colors=lu_col,width=20,fg_bg=bw_fg_bg}
|
||||
local sps_in = DataIndicator{parent=sps_box,x=2,label="",format="%15.2f",value=0,unit="mB/t",lu_colors=lu_col,width=20,fg_bg=bw_fg_bg}
|
||||
|
||||
sps_in.register(facility.ps, "po_am_rate", sps_in.update)
|
||||
|
||||
@@ -370,8 +370,8 @@ local function init(main)
|
||||
TextBox{parent=main,x=145,y=21,text="PROC. WASTE",alignment=ALIGN.CENTER,width=19,height=1,fg_bg=wh_gray}
|
||||
local pr_waste = Rectangle{parent=main,x=145,y=22,border=border(1,colors.gray,true),width=19,height=5,thin=true,fg_bg=bw_fg_bg}
|
||||
local pu = DataIndicator{parent=pr_waste,lu_colors=lu_col,label="Pu",unit="mB/t",format="%9.3f",value=0,width=17}
|
||||
local po = DataIndicator{parent=pr_waste,lu_colors=lu_col,label="Po",unit="mB/t",format="%9.3f",value=0,width=17}
|
||||
local popl = DataIndicator{parent=pr_waste,lu_colors=lu_col,label="PoPl",unit="mB/t",format="%7.3f",value=0,width=17}
|
||||
local po = DataIndicator{parent=pr_waste,lu_colors=lu_col,label="Po",unit="mB/t",format="%9.2f",value=0,width=17}
|
||||
local popl = DataIndicator{parent=pr_waste,lu_colors=lu_col,label="PoPl",unit="mB/t",format="%7.2f",value=0,width=17}
|
||||
|
||||
pu.register(facility.ps, "pu_rate", pu.update)
|
||||
po.register(facility.ps, "po_rate", po.update)
|
||||
|
||||
@@ -7,7 +7,7 @@ local flasher = require("graphics.flasher")
|
||||
|
||||
local core = {}
|
||||
|
||||
core.version = "2.0.7"
|
||||
core.version = "2.1.1"
|
||||
|
||||
core.flasher = flasher
|
||||
core.events = events
|
||||
|
||||
@@ -843,9 +843,12 @@ function element.new(args, child_offset_x, child_offset_y)
|
||||
|
||||
-- re-draw this element and all its children
|
||||
function public.redraw()
|
||||
local bg, fg = protected.window.getBackgroundColor(), protected.window.getTextColor()
|
||||
protected.window.setBackgroundColor(protected.fg_bg.bkg)
|
||||
protected.window.setTextColor(protected.fg_bg.fgd)
|
||||
protected.window.clear()
|
||||
protected.window.setBackgroundColor(bg)
|
||||
protected.window.setTextColor(fg)
|
||||
protected.redraw()
|
||||
for _, child in pairs(protected.children) do child.get().redraw() end
|
||||
end
|
||||
|
||||
@@ -24,7 +24,7 @@ local function checkbox(args)
|
||||
|
||||
args.can_focus = true
|
||||
args.height = 1
|
||||
args.width = 3 + string.len(args.label)
|
||||
args.width = 2 + string.len(args.label)
|
||||
|
||||
-- create new graphics element base object
|
||||
local e = element.new(args)
|
||||
|
||||
@@ -1,5 +1,7 @@
|
||||
-- Numeric Value Entry Graphics Element
|
||||
|
||||
local util = require("scada-common.util")
|
||||
|
||||
local core = require("graphics.core")
|
||||
local element = require("graphics.element")
|
||||
|
||||
@@ -8,9 +10,11 @@ local MOUSE_CLICK = core.events.MOUSE_CLICK
|
||||
|
||||
---@class number_field_args
|
||||
---@field default? number default value, defaults to 0
|
||||
---@field min? number minimum, forced on unfocus
|
||||
---@field max? number maximum, forced on unfocus
|
||||
---@field max_digits? integer maximum number of digits, defaults to width
|
||||
---@field min? number minimum, enforced on unfocus
|
||||
---@field max? number maximum, enforced on unfocus
|
||||
---@field max_chars? integer maximum number of characters, defaults to width
|
||||
---@field max_int_digits? integer maximum number of integer digits, enforced on unfocus
|
||||
---@field max_frac_digits? integer maximum number of fractional digits, enforced on unfocus
|
||||
---@field allow_decimal? boolean true to allow decimals
|
||||
---@field allow_negative? boolean true to allow negative numbers
|
||||
---@field dis_fg_bg? cpair foreground/background colors when disabled
|
||||
@@ -26,6 +30,9 @@ local MOUSE_CLICK = core.events.MOUSE_CLICK
|
||||
---@param args number_field_args
|
||||
---@return graphics_element element, element_id id
|
||||
local function number_field(args)
|
||||
element.assert(args.max_int_digits == nil or (util.is_int(args.max_int_digits) and args.max_int_digits > 0), "max_int_digits must be an integer greater than zero if supplied")
|
||||
element.assert(args.max_frac_digits == nil or (util.is_int(args.max_frac_digits) and args.max_frac_digits > 0), "max_frac_digits must be an integer greater than zero if supplied")
|
||||
|
||||
args.height = 1
|
||||
args.can_focus = true
|
||||
|
||||
@@ -34,13 +41,13 @@ local function number_field(args)
|
||||
|
||||
local has_decimal = false
|
||||
|
||||
args.max_digits = args.max_digits or e.frame.w
|
||||
args.max_chars = args.max_chars or e.frame.w
|
||||
|
||||
-- set initial value
|
||||
e.value = "" .. (args.default or 0)
|
||||
|
||||
-- make an interactive field manager
|
||||
local ifield = core.new_ifield(e, args.max_digits, args.fg_bg, args.dis_fg_bg)
|
||||
local ifield = core.new_ifield(e, args.max_chars, args.fg_bg, args.dis_fg_bg)
|
||||
|
||||
-- handle mouse interaction
|
||||
---@param event mouse_interaction mouse event
|
||||
@@ -50,7 +57,7 @@ local function number_field(args)
|
||||
if core.events.was_clicked(event.type) then
|
||||
e.take_focus()
|
||||
|
||||
if event.type == MOUSE_CLICK.UP then
|
||||
if event.type == MOUSE_CLICK.UP and e.in_frame_bounds(event.current.x, event.current.y) then
|
||||
ifield.move_cursor(event.current.x)
|
||||
end
|
||||
elseif event.type == MOUSE_CLICK.DOUBLE_CLICK then
|
||||
@@ -62,7 +69,7 @@ local function number_field(args)
|
||||
-- handle keyboard interaction
|
||||
---@param event key_interaction key event
|
||||
function e.handle_key(event)
|
||||
if event.type == KEY_CLICK.CHAR and string.len(e.value) < args.max_digits then
|
||||
if event.type == KEY_CLICK.CHAR and string.len(e.value) < args.max_chars then
|
||||
if tonumber(event.name) then
|
||||
if e.value == 0 then e.value = "" end
|
||||
ifield.try_insert_char(event.name)
|
||||
@@ -127,6 +134,37 @@ local function number_field(args)
|
||||
local min = tonumber(args.min)
|
||||
|
||||
if type(val) == "number" then
|
||||
if args.max_int_digits or args.max_frac_digits then
|
||||
local str = e.value
|
||||
local ceil = false
|
||||
|
||||
if string.find(str, "-") then str = string.sub(e.value, 2) end
|
||||
local parts = util.strtok(str, ".")
|
||||
|
||||
if parts[1] and args.max_int_digits then
|
||||
if string.len(parts[1]) > args.max_int_digits then
|
||||
parts[1] = string.rep("9", args.max_int_digits)
|
||||
ceil = true
|
||||
end
|
||||
end
|
||||
|
||||
if args.allow_decimal and args.max_frac_digits then
|
||||
if ceil then
|
||||
parts[2] = string.rep("9", args.max_frac_digits)
|
||||
elseif parts[2] and (string.len(parts[2]) > args.max_frac_digits) then
|
||||
-- add a half of the highest precision fractional value in order to round using floor
|
||||
local scaled = math.fmod(val, 1) * (10 ^ (args.max_frac_digits))
|
||||
local value = math.floor(scaled + 0.5)
|
||||
local unscaled = value * (10 ^ (-args.max_frac_digits))
|
||||
parts[2] = string.sub(tostring(unscaled), 3) -- remove starting "0."
|
||||
end
|
||||
end
|
||||
|
||||
if parts[2] then parts[2] = "." .. parts[2] else parts[2] = "" end
|
||||
|
||||
val = tonumber((parts[1] or "") .. parts[2])
|
||||
end
|
||||
|
||||
if type(args.max) == "number" and val > max then
|
||||
e.value = "" .. max
|
||||
ifield.nav_start()
|
||||
|
||||
@@ -45,7 +45,7 @@ local function text_field(args)
|
||||
if core.events.was_clicked(event.type) then
|
||||
e.take_focus()
|
||||
|
||||
if event.type == MOUSE_CLICK.UP then
|
||||
if event.type == MOUSE_CLICK.UP and e.in_frame_bounds(event.current.x, event.current.y) then
|
||||
ifield.move_cursor(event.current.x)
|
||||
end
|
||||
elseif event.type == MOUSE_CLICK.DOUBLE_CLICK then
|
||||
|
||||
@@ -2,9 +2,7 @@ return {
|
||||
-- initialize booted environment
|
||||
init_env = function ()
|
||||
local _require, _env = require("cc.require"), setmetatable({}, { __index = _ENV })
|
||||
-- overwrite require/package globals
|
||||
require, package = _require.make(_env, "/")
|
||||
-- reset terminal
|
||||
term.clear(); term.setCursorPos(1, 1)
|
||||
end
|
||||
}
|
||||
|
||||
@@ -1,27 +0,0 @@
|
||||
local config = {}
|
||||
|
||||
-- supervisor comms channel
|
||||
config.SVR_CHANNEL = 16240
|
||||
-- coordinator comms channel
|
||||
config.CRD_CHANNEL = 16243
|
||||
-- pocket comms channel
|
||||
config.PKT_CHANNEL = 16244
|
||||
-- max trusted modem message distance (0 to disable check)
|
||||
config.TRUSTED_RANGE = 0
|
||||
-- time in seconds (>= 2) before assuming a remote device is no longer active
|
||||
config.COMMS_TIMEOUT = 5
|
||||
-- facility authentication key (do NOT use one of your passwords)
|
||||
-- this enables verifying that messages are authentic
|
||||
-- all devices on the same network must use the same key
|
||||
-- config.AUTH_KEY = "SCADAfacility123"
|
||||
|
||||
-- log path
|
||||
config.LOG_PATH = "/log.txt"
|
||||
-- log mode
|
||||
-- 0 = APPEND (adds to existing file on start)
|
||||
-- 1 = NEW (replaces existing file on start)
|
||||
config.LOG_MODE = 0
|
||||
-- true to log verbose debug messages
|
||||
config.LOG_DEBUG = false
|
||||
|
||||
return config
|
||||
578
pocket/configure.lua
Normal file
578
pocket/configure.lua
Normal file
@@ -0,0 +1,578 @@
|
||||
--
|
||||
-- Configuration GUI
|
||||
--
|
||||
|
||||
local log = require("scada-common.log")
|
||||
local tcd = require("scada-common.tcd")
|
||||
local util = require("scada-common.util")
|
||||
|
||||
local core = require("graphics.core")
|
||||
|
||||
local DisplayBox = require("graphics.elements.displaybox")
|
||||
local Div = require("graphics.elements.div")
|
||||
local ListBox = require("graphics.elements.listbox")
|
||||
local MultiPane = require("graphics.elements.multipane")
|
||||
local TextBox = require("graphics.elements.textbox")
|
||||
|
||||
local CheckBox = require("graphics.elements.controls.checkbox")
|
||||
local PushButton = require("graphics.elements.controls.push_button")
|
||||
local RadioButton = require("graphics.elements.controls.radio_button")
|
||||
|
||||
local NumberField = require("graphics.elements.form.number_field")
|
||||
local TextField = require("graphics.elements.form.text_field")
|
||||
|
||||
local println = util.println
|
||||
local tri = util.trinary
|
||||
|
||||
local cpair = core.cpair
|
||||
|
||||
local LEFT = core.ALIGN.LEFT
|
||||
local CENTER = core.ALIGN.CENTER
|
||||
local RIGHT = core.ALIGN.RIGHT
|
||||
|
||||
-- changes to the config data/format to let the user know
|
||||
local changes = {}
|
||||
|
||||
---@class pkt_configurator
|
||||
local configurator = {}
|
||||
|
||||
local style = {}
|
||||
|
||||
style.root = cpair(colors.black, colors.lightGray)
|
||||
style.header = cpair(colors.white, colors.gray)
|
||||
|
||||
style.colors = {
|
||||
{ c = colors.red, hex = 0xdf4949 },
|
||||
{ c = colors.orange, hex = 0xffb659 },
|
||||
{ c = colors.yellow, hex = 0xfffc79 },
|
||||
{ c = colors.lime, hex = 0x80ff80 },
|
||||
{ c = colors.green, hex = 0x4aee8a },
|
||||
{ c = colors.cyan, hex = 0x34bac8 },
|
||||
{ c = colors.lightBlue, hex = 0x6cc0f2 },
|
||||
{ c = colors.blue, hex = 0x0096ff },
|
||||
{ c = colors.purple, hex = 0xb156ee },
|
||||
{ c = colors.pink, hex = 0xf26ba2 },
|
||||
{ c = colors.magenta, hex = 0xf9488a },
|
||||
{ c = colors.lightGray, hex = 0xcacaca },
|
||||
{ c = colors.gray, hex = 0x575757 }
|
||||
}
|
||||
|
||||
local bw_fg_bg = cpair(colors.black, colors.white)
|
||||
local g_lg_fg_bg = cpair(colors.gray, colors.lightGray)
|
||||
local nav_fg_bg = bw_fg_bg
|
||||
local btn_act_fg_bg = cpair(colors.white, colors.gray)
|
||||
local dis_fg_bg = cpair(colors.lightGray,colors.white)
|
||||
|
||||
local tool_ctl = {
|
||||
ask_config = false,
|
||||
has_config = false,
|
||||
viewing_config = false,
|
||||
importing_legacy = false,
|
||||
|
||||
view_cfg = nil, ---@type graphics_element
|
||||
settings_apply = nil, ---@type graphics_element
|
||||
|
||||
set_networked = nil, ---@type function
|
||||
bundled_emcool = nil, ---@type function
|
||||
gen_summary = nil, ---@type function
|
||||
show_current_cfg = nil, ---@type function
|
||||
load_legacy = nil, ---@type function
|
||||
|
||||
show_auth_key = nil, ---@type function
|
||||
show_key_btn = nil, ---@type graphics_element
|
||||
auth_key_textbox = nil, ---@type graphics_element
|
||||
auth_key_value = ""
|
||||
}
|
||||
|
||||
---@class pkt_config
|
||||
local tmp_cfg = {
|
||||
SVR_Channel = nil, ---@type integer
|
||||
CRD_Channel = nil, ---@type integer
|
||||
PKT_Channel = nil, ---@type integer
|
||||
ConnTimeout = nil, ---@type number
|
||||
TrustedRange = nil, ---@type number
|
||||
AuthKey = nil, ---@type string|nil
|
||||
LogMode = 0,
|
||||
LogPath = "",
|
||||
LogDebug = false,
|
||||
}
|
||||
|
||||
---@class pkt_config
|
||||
local ini_cfg = {}
|
||||
---@class pkt_config
|
||||
local settings_cfg = {}
|
||||
|
||||
-- all settings fields, their nice names, and their default values
|
||||
local fields = {
|
||||
{ "SVR_Channel", "SVR Channel", 16240 },
|
||||
{ "CRD_Channel", "CRD Channel", 16243 },
|
||||
{ "PKT_Channel", "PKT Channel", 16244 },
|
||||
{ "ConnTimeout", "Connection Timeout", 5 },
|
||||
{ "TrustedRange", "Trusted Range", 0 },
|
||||
{ "AuthKey", "Facility Auth Key" , ""},
|
||||
{ "LogMode", "Log Mode", log.MODE.APPEND },
|
||||
{ "LogPath", "Log Path", "/log.txt" },
|
||||
{ "LogDebug","Log Debug Messages", false }
|
||||
}
|
||||
|
||||
-- load data from the settings file
|
||||
---@param target pkt_config
|
||||
---@param raw boolean? true to not use default values
|
||||
local function load_settings(target, raw)
|
||||
for _, v in pairs(fields) do settings.unset(v[1]) end
|
||||
|
||||
local loaded = settings.load("/pocket.settings")
|
||||
|
||||
for _, v in pairs(fields) do target[v[1]] = settings.get(v[1], tri(raw, nil, v[3])) end
|
||||
|
||||
return loaded
|
||||
end
|
||||
|
||||
-- create the config view
|
||||
---@param display graphics_element
|
||||
local function config_view(display)
|
||||
---@diagnostic disable-next-line: undefined-field
|
||||
local function exit() os.queueEvent("terminate") end
|
||||
|
||||
TextBox{parent=display,y=1,text="Pocket Configurator",alignment=CENTER,height=1,fg_bg=style.header}
|
||||
|
||||
local root_pane_div = Div{parent=display,x=1,y=2}
|
||||
|
||||
local main_page = Div{parent=root_pane_div,x=1,y=1}
|
||||
local net_cfg = Div{parent=root_pane_div,x=1,y=1}
|
||||
local log_cfg = Div{parent=root_pane_div,x=1,y=1}
|
||||
local summary = Div{parent=root_pane_div,x=1,y=1}
|
||||
local changelog = Div{parent=root_pane_div,x=1,y=1}
|
||||
|
||||
local main_pane = MultiPane{parent=root_pane_div,x=1,y=1,panes={main_page,net_cfg,log_cfg,summary,changelog}}
|
||||
|
||||
-- Main Page
|
||||
|
||||
local y_start = 7
|
||||
|
||||
TextBox{parent=main_page,x=2,y=2,height=4,text="Welcome to the Pocket configurator! Please select one of the following options."}
|
||||
|
||||
if tool_ctl.ask_config then
|
||||
TextBox{parent=main_page,x=2,y=y_start,height=4,width=49,text="Please configure before starting up.",fg_bg=cpair(colors.red,colors.lightGray)}
|
||||
y_start = y_start + 3
|
||||
end
|
||||
|
||||
local function view_config()
|
||||
tool_ctl.viewing_config = true
|
||||
tool_ctl.gen_summary(settings_cfg)
|
||||
tool_ctl.settings_apply.hide(true)
|
||||
main_pane.set_value(4)
|
||||
end
|
||||
|
||||
if fs.exists("/pocket/config.lua") then
|
||||
PushButton{parent=main_page,x=2,y=y_start,min_width=22,text="Import Legacy Config",callback=function()tool_ctl.load_legacy()end,fg_bg=cpair(colors.black,colors.cyan),active_fg_bg=btn_act_fg_bg}
|
||||
y_start = y_start + 2
|
||||
end
|
||||
|
||||
PushButton{parent=main_page,x=2,y=y_start,min_width=18,text="Configure Device",callback=function()main_pane.set_value(2)end,fg_bg=cpair(colors.black,colors.blue),active_fg_bg=btn_act_fg_bg}
|
||||
tool_ctl.view_cfg = PushButton{parent=main_page,x=2,y=y_start+2,min_width=20,text="View Configuration",callback=view_config,fg_bg=cpair(colors.black,colors.blue),active_fg_bg=btn_act_fg_bg,dis_fg_bg=dis_fg_bg}
|
||||
|
||||
if not tool_ctl.has_config then tool_ctl.view_cfg.disable() end
|
||||
|
||||
PushButton{parent=main_page,x=2,y=18,min_width=6,text="Exit",callback=exit,fg_bg=cpair(colors.black,colors.red),active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=main_page,x=14,y=18,min_width=12,text="Change Log",callback=function()main_pane.set_value(5)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
|
||||
--#region Network
|
||||
|
||||
local net_c_1 = Div{parent=net_cfg,x=2,y=4,width=24}
|
||||
local net_c_2 = Div{parent=net_cfg,x=2,y=4,width=24}
|
||||
local net_c_3 = Div{parent=net_cfg,x=2,y=4,width=24}
|
||||
local net_c_4 = Div{parent=net_cfg,x=2,y=4,width=24}
|
||||
|
||||
local net_pane = MultiPane{parent=net_cfg,x=1,y=4,panes={net_c_1,net_c_2,net_c_3,net_c_4}}
|
||||
|
||||
TextBox{parent=net_cfg,x=1,y=2,height=1,text=" Network Configuration",fg_bg=cpair(colors.black,colors.lightBlue)}
|
||||
|
||||
TextBox{parent=net_c_1,x=1,y=1,height=1,text="Set network channels."}
|
||||
TextBox{parent=net_c_1,x=1,y=3,height=4,text="Each of the named channels must be the same within a particular SCADA network.",fg_bg=g_lg_fg_bg}
|
||||
|
||||
TextBox{parent=net_c_1,x=1,y=8,height=1,width=18,text="Supervisor Channel"}
|
||||
local svr_chan = NumberField{parent=net_c_1,x=1,y=9,width=7,default=ini_cfg.SVR_Channel,min=1,max=65535,fg_bg=bw_fg_bg}
|
||||
TextBox{parent=net_c_1,x=9,y=9,height=4,text="[SVR_CHANNEL]",fg_bg=g_lg_fg_bg}
|
||||
|
||||
TextBox{parent=net_c_1,x=1,y=10,height=1,width=19,text="Coordinator Channel"}
|
||||
local crd_chan = NumberField{parent=net_c_1,x=1,y=11,width=7,default=ini_cfg.CRD_Channel,min=1,max=65535,fg_bg=bw_fg_bg}
|
||||
TextBox{parent=net_c_1,x=9,y=11,height=4,text="[CRD_CHANNEL]",fg_bg=g_lg_fg_bg}
|
||||
|
||||
TextBox{parent=net_c_1,x=1,y=12,height=1,width=14,text="Pocket Channel"}
|
||||
local pkt_chan = NumberField{parent=net_c_1,x=1,y=13,width=7,default=ini_cfg.PKT_Channel,min=1,max=65535,fg_bg=bw_fg_bg}
|
||||
TextBox{parent=net_c_1,x=9,y=13,height=4,text="[PKT_CHANNEL]",fg_bg=g_lg_fg_bg}
|
||||
|
||||
local chan_err = TextBox{parent=net_c_1,x=1,y=14,height=1,width=24,text="Please set all channels.",fg_bg=cpair(colors.red,colors.lightGray),hidden=true}
|
||||
|
||||
local function submit_channels()
|
||||
local svr_c, crd_c, pkt_c = tonumber(svr_chan.get_value()), tonumber(crd_chan.get_value()), tonumber(pkt_chan.get_value())
|
||||
if svr_c ~= nil and crd_c ~= nil and pkt_c ~= nil then
|
||||
tmp_cfg.SVR_Channel, tmp_cfg.CRD_Channel, tmp_cfg.PKT_Channel = svr_c, crd_c, pkt_c
|
||||
net_pane.set_value(2)
|
||||
chan_err.hide(true)
|
||||
else chan_err.show() end
|
||||
end
|
||||
|
||||
PushButton{parent=net_c_1,x=1,y=15,text="\x1b Back",callback=function()main_pane.set_value(1)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=net_c_1,x=19,y=15,text="Next \x1a",callback=submit_channels,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
|
||||
TextBox{parent=net_c_2,x=1,y=1,height=1,text="Set connection timeout."}
|
||||
TextBox{parent=net_c_2,x=1,y=3,height=7,text="You generally should not need to modify this. On slow servers, you can try to increase this to make the system wait longer before assuming a disconnection.",fg_bg=g_lg_fg_bg}
|
||||
|
||||
TextBox{parent=net_c_2,x=1,y=11,height=1,width=19,text="Connection Timeout"}
|
||||
local timeout = NumberField{parent=net_c_2,x=1,y=12,width=7,default=ini_cfg.ConnTimeout,min=2,max=25,max_chars=6,max_frac_digits=2,allow_decimal=true,fg_bg=bw_fg_bg}
|
||||
|
||||
TextBox{parent=net_c_2,x=9,y=12,height=2,text="seconds\n(default 5)",fg_bg=g_lg_fg_bg}
|
||||
|
||||
local ct_err = TextBox{parent=net_c_2,x=1,y=14,height=1,width=24,text="Please set timeout.",fg_bg=cpair(colors.red,colors.lightGray),hidden=true}
|
||||
|
||||
local function submit_timeouts()
|
||||
local timeout_val = tonumber(timeout.get_value())
|
||||
if timeout_val ~= nil then
|
||||
tmp_cfg.ConnTimeout = timeout_val
|
||||
net_pane.set_value(3)
|
||||
ct_err.hide(true)
|
||||
else ct_err.show() end
|
||||
end
|
||||
|
||||
PushButton{parent=net_c_2,x=1,y=15,text="\x1b Back",callback=function()net_pane.set_value(1)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=net_c_2,x=19,y=15,text="Next \x1a",callback=submit_timeouts,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
|
||||
TextBox{parent=net_c_3,x=1,y=1,height=1,text="Set the trusted range."}
|
||||
TextBox{parent=net_c_3,x=1,y=3,height=4,text="Setting this to a value larger than 0 prevents connections with devices that many blocks away.",fg_bg=g_lg_fg_bg}
|
||||
TextBox{parent=net_c_3,x=1,y=8,height=4,text="This is optional. You can disable this functionality by setting the value to 0.",fg_bg=g_lg_fg_bg}
|
||||
|
||||
local range = NumberField{parent=net_c_3,x=1,y=13,width=10,default=ini_cfg.TrustedRange,min=0,max_chars=20,allow_decimal=true,fg_bg=bw_fg_bg}
|
||||
|
||||
local tr_err = TextBox{parent=net_c_3,x=1,y=14,height=1,width=24,text="Set the trusted range.",fg_bg=cpair(colors.red,colors.lightGray),hidden=true}
|
||||
|
||||
local function submit_tr()
|
||||
local range_val = tonumber(range.get_value())
|
||||
if range_val ~= nil then
|
||||
tmp_cfg.TrustedRange = range_val
|
||||
net_pane.set_value(4)
|
||||
tr_err.hide(true)
|
||||
else tr_err.show() end
|
||||
end
|
||||
|
||||
PushButton{parent=net_c_3,x=1,y=15,text="\x1b Back",callback=function()net_pane.set_value(2)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=net_c_3,x=19,y=15,text="Next \x1a",callback=submit_tr,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
|
||||
TextBox{parent=net_c_4,x=1,y=1,height=4,text="Optionally, set the facility authentication key. Do NOT use one of your passwords."}
|
||||
TextBox{parent=net_c_4,x=1,y=6,height=6,text="This enables verifying that messages are authentic, so it is intended for security on multiplayer servers.",fg_bg=g_lg_fg_bg}
|
||||
|
||||
TextBox{parent=net_c_4,x=1,y=12,height=1,text="Facility Auth Key"}
|
||||
local key, _, censor = TextField{parent=net_c_4,x=1,y=13,max_len=64,value=ini_cfg.AuthKey,width=24,height=1,fg_bg=bw_fg_bg}
|
||||
|
||||
local function censor_key(enable) censor(util.trinary(enable, "*", nil)) end
|
||||
|
||||
-- declare back first so tabbing makes sense visually
|
||||
PushButton{parent=net_c_4,x=1,y=15,text="\x1b Back",callback=function()net_pane.set_value(3)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
|
||||
local hide_key = CheckBox{parent=net_c_4,x=8,y=15,label="Hide Key",box_fg_bg=cpair(colors.lightBlue,colors.black),callback=censor_key}
|
||||
|
||||
hide_key.set_value(true)
|
||||
censor_key(true)
|
||||
|
||||
local key_err = TextBox{parent=net_c_4,x=1,y=14,height=1,width=24,text="Length must be > 7.",fg_bg=cpair(colors.red,colors.lightGray),hidden=true}
|
||||
|
||||
local function submit_auth()
|
||||
local v = key.get_value()
|
||||
if string.len(v) == 0 or string.len(v) >= 8 then
|
||||
tmp_cfg.AuthKey = key.get_value()
|
||||
main_pane.set_value(3)
|
||||
key_err.hide(true)
|
||||
else key_err.show() end
|
||||
end
|
||||
|
||||
PushButton{parent=net_c_4,x=19,y=15,text="Next \x1a",callback=submit_auth,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
|
||||
--#endregion
|
||||
|
||||
--#region Logging
|
||||
|
||||
local log_c_1 = Div{parent=log_cfg,x=2,y=4,width=24}
|
||||
|
||||
TextBox{parent=log_cfg,x=1,y=2,height=1,text=" Logging Configuration",fg_bg=cpair(colors.black,colors.pink)}
|
||||
|
||||
TextBox{parent=log_c_1,x=1,y=1,height=1,text="Configure logging below."}
|
||||
|
||||
TextBox{parent=log_c_1,x=1,y=3,height=1,text="Log File Mode"}
|
||||
local mode = RadioButton{parent=log_c_1,x=1,y=4,default=ini_cfg.LogMode+1,options={"Append on Startup","Replace on Startup"},callback=function()end,radio_colors=cpair(colors.lightGray,colors.black),select_color=colors.pink}
|
||||
|
||||
TextBox{parent=log_c_1,x=1,y=7,height=1,text="Log File Path"}
|
||||
local path = TextField{parent=log_c_1,x=1,y=8,width=24,height=1,value=ini_cfg.LogPath,max_len=128,fg_bg=bw_fg_bg}
|
||||
|
||||
local en_dbg = CheckBox{parent=log_c_1,x=1,y=10,default=ini_cfg.LogDebug,label="Enable Debug Messages",box_fg_bg=cpair(colors.pink,colors.black)}
|
||||
TextBox{parent=log_c_1,x=3,y=11,height=4,text="This results in much larger log files. Use only as needed.",fg_bg=g_lg_fg_bg}
|
||||
|
||||
local path_err = TextBox{parent=log_c_1,x=1,y=14,height=1,width=24,text="Provide a log file path.",fg_bg=cpair(colors.red,colors.lightGray),hidden=true}
|
||||
|
||||
local function submit_log()
|
||||
if path.get_value() ~= "" then
|
||||
path_err.hide(true)
|
||||
tmp_cfg.LogMode = mode.get_value() - 1
|
||||
tmp_cfg.LogPath = path.get_value()
|
||||
tmp_cfg.LogDebug = en_dbg.get_value()
|
||||
tool_ctl.gen_summary(tmp_cfg)
|
||||
tool_ctl.viewing_config = false
|
||||
tool_ctl.importing_legacy = false
|
||||
tool_ctl.settings_apply.show()
|
||||
main_pane.set_value(4)
|
||||
else path_err.show() end
|
||||
end
|
||||
|
||||
PushButton{parent=log_c_1,x=1,y=15,text="\x1b Back",callback=function()main_pane.set_value(2)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=log_c_1,x=19,y=15,text="Next \x1a",callback=submit_log,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
|
||||
--#endregion
|
||||
|
||||
--#region Summary and Saving
|
||||
|
||||
local sum_c_1 = Div{parent=summary,x=2,y=4,width=24}
|
||||
local sum_c_2 = Div{parent=summary,x=2,y=4,width=24}
|
||||
local sum_c_3 = Div{parent=summary,x=2,y=4,width=24}
|
||||
local sum_c_4 = Div{parent=summary,x=2,y=4,width=24}
|
||||
|
||||
local sum_pane = MultiPane{parent=summary,x=1,y=4,panes={sum_c_1,sum_c_2,sum_c_3,sum_c_4}}
|
||||
|
||||
TextBox{parent=summary,x=1,y=2,height=1,text=" Summary",fg_bg=cpair(colors.black,colors.green)}
|
||||
|
||||
local setting_list = ListBox{parent=sum_c_1,x=1,y=1,height=11,width=24,scroll_height=100,fg_bg=bw_fg_bg,nav_fg_bg=g_lg_fg_bg,nav_active=cpair(colors.black,colors.gray)}
|
||||
|
||||
local function back_from_summary()
|
||||
if tool_ctl.viewing_config or tool_ctl.importing_legacy then
|
||||
main_pane.set_value(1)
|
||||
tool_ctl.viewing_config = false
|
||||
tool_ctl.importing_legacy = false
|
||||
tool_ctl.settings_apply.show()
|
||||
else
|
||||
main_pane.set_value(3)
|
||||
end
|
||||
end
|
||||
|
||||
---@param element graphics_element
|
||||
---@param data any
|
||||
local function try_set(element, data)
|
||||
if data ~= nil then element.set_value(data) end
|
||||
end
|
||||
|
||||
local function save_and_continue()
|
||||
for k, v in pairs(tmp_cfg) do settings.set(k, v) end
|
||||
|
||||
if settings.save("/pocket.settings") then
|
||||
load_settings(settings_cfg, true)
|
||||
load_settings(ini_cfg)
|
||||
|
||||
try_set(svr_chan, ini_cfg.SVR_Channel)
|
||||
try_set(crd_chan, ini_cfg.CRD_Channel)
|
||||
try_set(pkt_chan, ini_cfg.PKT_Channel)
|
||||
try_set(timeout, ini_cfg.ConnTimeout)
|
||||
try_set(range, ini_cfg.TrustedRange)
|
||||
try_set(key, ini_cfg.AuthKey)
|
||||
try_set(mode, ini_cfg.LogMode)
|
||||
try_set(path, ini_cfg.LogPath)
|
||||
try_set(en_dbg, ini_cfg.LogDebug)
|
||||
|
||||
tool_ctl.view_cfg.enable()
|
||||
|
||||
if tool_ctl.importing_legacy then
|
||||
tool_ctl.importing_legacy = false
|
||||
sum_pane.set_value(3)
|
||||
else
|
||||
sum_pane.set_value(2)
|
||||
end
|
||||
else
|
||||
sum_pane.set_value(4)
|
||||
end
|
||||
end
|
||||
|
||||
PushButton{parent=sum_c_1,x=1,y=15,text="\x1b Back",callback=back_from_summary,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
tool_ctl.show_key_btn = PushButton{parent=sum_c_1,x=1,y=13,min_width=17,text="Unhide Auth Key",callback=function()tool_ctl.show_auth_key()end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg,dis_fg_bg=dis_fg_bg}
|
||||
tool_ctl.settings_apply = PushButton{parent=sum_c_1,x=18,y=15,min_width=7,text="Apply",callback=save_and_continue,fg_bg=cpair(colors.black,colors.green),active_fg_bg=btn_act_fg_bg}
|
||||
|
||||
TextBox{parent=sum_c_2,x=1,y=1,height=1,text="Settings saved!"}
|
||||
|
||||
local function go_home()
|
||||
main_pane.set_value(1)
|
||||
net_pane.set_value(1)
|
||||
sum_pane.set_value(1)
|
||||
end
|
||||
|
||||
PushButton{parent=sum_c_2,x=1,y=15,min_width=6,text="Home",callback=go_home,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=sum_c_2,x=19,y=15,min_width=6,text="Exit",callback=exit,fg_bg=cpair(colors.black,colors.red),active_fg_bg=cpair(colors.white,colors.gray)}
|
||||
|
||||
TextBox{parent=sum_c_3,x=1,y=1,height=4,text="The old config.lua file will now be deleted, then the configurator will exit."}
|
||||
|
||||
local function delete_legacy()
|
||||
fs.delete("/pocket/config.lua")
|
||||
exit()
|
||||
end
|
||||
|
||||
PushButton{parent=sum_c_3,x=1,y=15,min_width=8,text="Cancel",callback=go_home,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=sum_c_3,x=19,y=15,min_width=6,text="OK",callback=delete_legacy,fg_bg=cpair(colors.black,colors.green),active_fg_bg=cpair(colors.white,colors.gray)}
|
||||
|
||||
TextBox{parent=sum_c_4,x=1,y=1,height=8,text="Failed to save the settings file.\n\nThere may not be enough space for the modification or server file permissions may be denying writes."}
|
||||
PushButton{parent=sum_c_4,x=1,y=15,min_width=6,text="Home",callback=go_home,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=sum_c_4,x=19,y=15,min_width=6,text="Exit",callback=exit,fg_bg=cpair(colors.black,colors.red),active_fg_bg=cpair(colors.white,colors.gray)}
|
||||
|
||||
--#endregion
|
||||
|
||||
-- Config Change Log
|
||||
|
||||
local cl = Div{parent=changelog,x=2,y=4,width=24}
|
||||
|
||||
TextBox{parent=changelog,x=1,y=2,height=1,text=" Config Change Log",fg_bg=bw_fg_bg}
|
||||
|
||||
local c_log = ListBox{parent=cl,x=1,y=1,height=13,width=24,scroll_height=100,fg_bg=bw_fg_bg,nav_fg_bg=g_lg_fg_bg,nav_active=cpair(colors.black,colors.gray)}
|
||||
|
||||
for _, change in ipairs(changes) do
|
||||
TextBox{parent=c_log,text=change[1],height=1,fg_bg=bw_fg_bg}
|
||||
for _, v in ipairs(change[2]) do
|
||||
local e = Div{parent=c_log,height=#util.strwrap(v,21)}
|
||||
TextBox{parent=e,y=1,x=1,text="- ",height=1,fg_bg=cpair(colors.gray,colors.white)}
|
||||
TextBox{parent=e,y=1,x=3,text=v,height=e.get_height(),fg_bg=cpair(colors.gray,colors.white)}
|
||||
end
|
||||
end
|
||||
|
||||
PushButton{parent=cl,x=1,y=15,text="\x1b Back",callback=function()main_pane.set_value(1)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
|
||||
-- set tool functions now that we have the elements
|
||||
|
||||
-- load a legacy config file
|
||||
function tool_ctl.load_legacy()
|
||||
local config = require("pocket.config")
|
||||
|
||||
tmp_cfg.SVR_Channel = config.SVR_CHANNEL
|
||||
tmp_cfg.CRD_Channel = config.CRD_CHANNEL
|
||||
tmp_cfg.PKT_Channel = config.PKT_CHANNEL
|
||||
tmp_cfg.ConnTimeout = config.COMMS_TIMEOUT
|
||||
tmp_cfg.TrustedRange = config.TRUSTED_RANGE
|
||||
tmp_cfg.AuthKey = config.AUTH_KEY or ""
|
||||
|
||||
tmp_cfg.LogMode = config.LOG_MODE
|
||||
tmp_cfg.LogPath = config.LOG_PATH
|
||||
tmp_cfg.LogDebug = config.LOG_DEBUG or false
|
||||
|
||||
tool_ctl.gen_summary(tmp_cfg)
|
||||
sum_pane.set_value(1)
|
||||
main_pane.set_value(4)
|
||||
tool_ctl.importing_legacy = true
|
||||
end
|
||||
|
||||
-- expose the auth key on the summary page
|
||||
function tool_ctl.show_auth_key()
|
||||
tool_ctl.show_key_btn.disable()
|
||||
tool_ctl.auth_key_textbox.set_value(tool_ctl.auth_key_value)
|
||||
end
|
||||
|
||||
-- generate the summary list
|
||||
---@param cfg pkt_config
|
||||
function tool_ctl.gen_summary(cfg)
|
||||
setting_list.remove_all()
|
||||
|
||||
local alternate = false
|
||||
local inner_width = setting_list.get_width() - 1
|
||||
|
||||
tool_ctl.show_key_btn.enable()
|
||||
tool_ctl.auth_key_value = cfg.AuthKey or "" -- to show auth key
|
||||
|
||||
for i = 1, #fields do
|
||||
local f = fields[i]
|
||||
local height = 1
|
||||
local label_w = string.len(f[2])
|
||||
local val_max_w = (inner_width - label_w) - 1
|
||||
local raw = cfg[f[1]]
|
||||
local val = util.strval(raw)
|
||||
|
||||
if f[1] == "AuthKey" then val = string.rep("*", string.len(val))
|
||||
elseif f[1] == "LogMode" then val = util.trinary(raw == log.MODE.APPEND, "append", "replace") end
|
||||
|
||||
if val == "nil" then val = "<not set>" end
|
||||
|
||||
local c = util.trinary(alternate, g_lg_fg_bg, cpair(colors.gray,colors.white))
|
||||
alternate = not alternate
|
||||
|
||||
if string.len(val) > val_max_w then
|
||||
local lines = util.strwrap(val, inner_width)
|
||||
height = #lines + 1
|
||||
end
|
||||
|
||||
local line = Div{parent=setting_list,height=height,fg_bg=c}
|
||||
TextBox{parent=line,text=f[2],width=string.len(f[2]),fg_bg=cpair(colors.black,line.get_fg_bg().bkg)}
|
||||
|
||||
local textbox
|
||||
if height > 1 then
|
||||
textbox = TextBox{parent=line,x=1,y=2,text=val,height=height-1,alignment=LEFT}
|
||||
else
|
||||
textbox = TextBox{parent=line,x=label_w+1,y=1,text=val,alignment=RIGHT}
|
||||
end
|
||||
|
||||
if f[1] == "AuthKey" then tool_ctl.auth_key_textbox = textbox end
|
||||
end
|
||||
end
|
||||
end
|
||||
|
||||
-- reset terminal screen
|
||||
local function reset_term()
|
||||
term.setTextColor(colors.white)
|
||||
term.setBackgroundColor(colors.black)
|
||||
term.clear()
|
||||
term.setCursorPos(1, 1)
|
||||
end
|
||||
|
||||
-- run the pcoket configurator
|
||||
---@param ask_config? boolean indicate if this is being called by the startup app due to an invalid configuration
|
||||
function configurator.configure(ask_config)
|
||||
tool_ctl.ask_config = ask_config == true
|
||||
|
||||
load_settings(settings_cfg, true)
|
||||
tool_ctl.has_config = load_settings(ini_cfg)
|
||||
|
||||
reset_term()
|
||||
|
||||
-- set overridden colors
|
||||
for i = 1, #style.colors do
|
||||
term.setPaletteColor(style.colors[i].c, style.colors[i].hex)
|
||||
end
|
||||
|
||||
local status, error = pcall(function ()
|
||||
local display = DisplayBox{window=term.current(),fg_bg=style.root}
|
||||
config_view(display)
|
||||
|
||||
while true do
|
||||
local event, param1, param2, param3 = util.pull_event()
|
||||
|
||||
-- handle event
|
||||
if event == "timer" then
|
||||
tcd.handle(param1)
|
||||
elseif event == "mouse_click" or event == "mouse_up" or event == "mouse_drag" or event == "mouse_scroll" or event == "double_click" then
|
||||
local m_e = core.events.new_mouse_event(event, param1, param2, param3)
|
||||
if m_e then display.handle_mouse(m_e) end
|
||||
elseif event == "char" or event == "key" or event == "key_up" then
|
||||
local k_e = core.events.new_key_event(event, param1, param2)
|
||||
if k_e then display.handle_key(k_e) end
|
||||
elseif event == "paste" then
|
||||
display.handle_paste(param1)
|
||||
end
|
||||
|
||||
if event == "terminate" then return end
|
||||
end
|
||||
end)
|
||||
|
||||
-- restore colors
|
||||
for i = 1, #style.colors do
|
||||
local r, g, b = term.nativePaletteColor(style.colors[i].c)
|
||||
term.setPaletteColor(style.colors[i].c, r, g, b)
|
||||
end
|
||||
|
||||
reset_term()
|
||||
if not status then
|
||||
println("configurator error: " .. error)
|
||||
end
|
||||
|
||||
return status, error
|
||||
end
|
||||
|
||||
return configurator
|
||||
@@ -13,17 +13,57 @@ local LINK_STATE = iocontrol.LINK_STATE
|
||||
|
||||
local pocket = {}
|
||||
|
||||
---@type pkt_config
|
||||
local config = {}
|
||||
|
||||
pocket.config = config
|
||||
|
||||
-- load the pocket configuration
|
||||
function pocket.load_config()
|
||||
if not settings.load("/pocket.settings") then return false end
|
||||
|
||||
config.SVR_Channel = settings.get("SVR_Channel")
|
||||
config.CRD_Channel = settings.get("CRD_Channel")
|
||||
config.PKT_Channel = settings.get("PKT_Channel")
|
||||
config.ConnTimeout = settings.get("ConnTimeout")
|
||||
config.TrustedRange = settings.get("TrustedRange")
|
||||
config.AuthKey = settings.get("AuthKey")
|
||||
|
||||
config.LogMode = settings.get("LogMode")
|
||||
config.LogPath = settings.get("LogPath")
|
||||
config.LogDebug = settings.get("LogDebug")
|
||||
|
||||
local cfv = util.new_validator()
|
||||
|
||||
cfv.assert_channel(config.SVR_Channel)
|
||||
cfv.assert_channel(config.CRD_Channel)
|
||||
cfv.assert_channel(config.PKT_Channel)
|
||||
cfv.assert_type_num(config.ConnTimeout)
|
||||
cfv.assert_min(config.ConnTimeout, 2)
|
||||
cfv.assert_type_num(config.TrustedRange)
|
||||
cfv.assert_min(config.TrustedRange, 0)
|
||||
cfv.assert_type_str(config.AuthKey)
|
||||
|
||||
if type(config.AuthKey) == "string" then
|
||||
local len = string.len(config.AuthKey)
|
||||
cfv.assert(len == 0 or len >= 8)
|
||||
end
|
||||
|
||||
cfv.assert_type_int(config.LogMode)
|
||||
cfv.assert_range(config.LogMode, 0, 1)
|
||||
cfv.assert_type_str(config.LogPath)
|
||||
cfv.assert_type_bool(config.LogDebug)
|
||||
|
||||
return cfv.valid()
|
||||
end
|
||||
|
||||
-- pocket coordinator + supervisor communications
|
||||
---@nodiscard
|
||||
---@param version string pocket version
|
||||
---@param nic nic network interface device
|
||||
---@param pkt_channel integer pocket comms channel
|
||||
---@param svr_channel integer supervisor access channel
|
||||
---@param crd_channel integer coordinator access channel
|
||||
---@param range integer trusted device connection range
|
||||
---@param sv_watchdog watchdog
|
||||
---@param api_watchdog watchdog
|
||||
function pocket.comms(version, nic, pkt_channel, svr_channel, crd_channel, range, sv_watchdog, api_watchdog)
|
||||
function pocket.comms(version, nic, sv_watchdog, api_watchdog)
|
||||
local self = {
|
||||
sv = {
|
||||
linked = false,
|
||||
@@ -42,13 +82,13 @@ function pocket.comms(version, nic, pkt_channel, svr_channel, crd_channel, range
|
||||
establish_delay_counter = 0
|
||||
}
|
||||
|
||||
comms.set_trusted_range(range)
|
||||
comms.set_trusted_range(config.TrustedRange)
|
||||
|
||||
-- PRIVATE FUNCTIONS --
|
||||
|
||||
-- configure network channels
|
||||
nic.closeAll()
|
||||
nic.open(pkt_channel)
|
||||
nic.open(config.PKT_Channel)
|
||||
|
||||
-- send a management packet to the supervisor
|
||||
---@param msg_type MGMT_TYPE
|
||||
@@ -60,7 +100,7 @@ function pocket.comms(version, nic, pkt_channel, svr_channel, crd_channel, range
|
||||
pkt.make(msg_type, msg)
|
||||
s_pkt.make(self.sv.addr, self.sv.seq_num, PROTOCOL.SCADA_MGMT, pkt.raw_sendable())
|
||||
|
||||
nic.transmit(svr_channel, pkt_channel, s_pkt)
|
||||
nic.transmit(config.SVR_Channel, config.PKT_Channel, s_pkt)
|
||||
self.sv.seq_num = self.sv.seq_num + 1
|
||||
end
|
||||
|
||||
@@ -74,7 +114,7 @@ function pocket.comms(version, nic, pkt_channel, svr_channel, crd_channel, range
|
||||
pkt.make(msg_type, msg)
|
||||
s_pkt.make(self.api.addr, self.api.seq_num, PROTOCOL.SCADA_MGMT, pkt.raw_sendable())
|
||||
|
||||
nic.transmit(crd_channel, pkt_channel, s_pkt)
|
||||
nic.transmit(config.CRD_Channel, config.PKT_Channel, s_pkt)
|
||||
self.api.seq_num = self.api.seq_num + 1
|
||||
end
|
||||
|
||||
@@ -217,9 +257,9 @@ function pocket.comms(version, nic, pkt_channel, svr_channel, crd_channel, range
|
||||
local protocol = packet.scada_frame.protocol()
|
||||
local src_addr = packet.scada_frame.src_addr()
|
||||
|
||||
if l_chan ~= pkt_channel then
|
||||
if l_chan ~= config.PKT_Channel then
|
||||
log.debug("received packet on unconfigured channel " .. l_chan, true)
|
||||
elseif r_chan == crd_channel then
|
||||
elseif r_chan == config.CRD_Channel then
|
||||
-- check sequence number
|
||||
if self.api.r_seq_num == nil then
|
||||
self.api.r_seq_num = packet.scada_frame.seq_num()
|
||||
@@ -308,7 +348,7 @@ function pocket.comms(version, nic, pkt_channel, svr_channel, crd_channel, range
|
||||
else
|
||||
log.debug("illegal packet type " .. protocol .. " from coordinator", true)
|
||||
end
|
||||
elseif r_chan == svr_channel then
|
||||
elseif r_chan == config.SVR_Channel then
|
||||
-- check sequence number
|
||||
if self.sv.r_seq_num == nil then
|
||||
self.sv.r_seq_num = packet.scada_frame.seq_num()
|
||||
|
||||
@@ -13,38 +13,41 @@ local util = require("scada-common.util")
|
||||
|
||||
local core = require("graphics.core")
|
||||
|
||||
local config = require("pocket.config")
|
||||
local configure = require("pocket.configure")
|
||||
local iocontrol = require("pocket.iocontrol")
|
||||
local pocket = require("pocket.pocket")
|
||||
local renderer = require("pocket.renderer")
|
||||
|
||||
local POCKET_VERSION = "v0.6.3-alpha"
|
||||
local POCKET_VERSION = "v0.7.1-alpha"
|
||||
|
||||
local println = util.println
|
||||
local println_ts = util.println_ts
|
||||
|
||||
----------------------------------------
|
||||
-- config validation
|
||||
-- get configuration
|
||||
----------------------------------------
|
||||
|
||||
local cfv = util.new_validator()
|
||||
if not pocket.load_config() then
|
||||
-- try to reconfigure (user action)
|
||||
local success, error = configure.configure(true)
|
||||
if success then
|
||||
if not pocket.load_config() then
|
||||
println("failed to load a valid configuration, please reconfigure")
|
||||
return
|
||||
end
|
||||
else
|
||||
println("configuration error: " .. error)
|
||||
return
|
||||
end
|
||||
end
|
||||
|
||||
cfv.assert_channel(config.SVR_CHANNEL)
|
||||
cfv.assert_channel(config.CRD_CHANNEL)
|
||||
cfv.assert_channel(config.PKT_CHANNEL)
|
||||
cfv.assert_type_int(config.TRUSTED_RANGE)
|
||||
cfv.assert_type_num(config.COMMS_TIMEOUT)
|
||||
cfv.assert_min(config.COMMS_TIMEOUT, 2)
|
||||
cfv.assert_type_str(config.LOG_PATH)
|
||||
cfv.assert_type_int(config.LOG_MODE)
|
||||
|
||||
assert(cfv.valid(), "bad config file: missing/invalid fields")
|
||||
local config = pocket.config
|
||||
|
||||
----------------------------------------
|
||||
-- log init
|
||||
----------------------------------------
|
||||
|
||||
log.init(config.LOG_PATH, config.LOG_MODE, config.LOG_DEBUG == true)
|
||||
log.init(config.LogPath, config.LogMode, config.LogDebug)
|
||||
|
||||
log.info("========================================")
|
||||
log.info("BOOTING pocket.startup " .. POCKET_VERSION)
|
||||
@@ -69,8 +72,8 @@ local function main()
|
||||
----------------------------------------
|
||||
|
||||
-- message authentication init
|
||||
if type(config.AUTH_KEY) == "string" then
|
||||
network.init_mac(config.AUTH_KEY)
|
||||
if type(config.AuthKey) == "string" and string.len(config.AuthKey) > 0 then
|
||||
network.init_mac(config.AuthKey)
|
||||
end
|
||||
|
||||
iocontrol.report_link_state(iocontrol.LINK_STATE.UNLINKED)
|
||||
@@ -85,8 +88,8 @@ local function main()
|
||||
|
||||
-- create connection watchdogs
|
||||
local conn_wd = {
|
||||
sv = util.new_watchdog(config.COMMS_TIMEOUT),
|
||||
api = util.new_watchdog(config.COMMS_TIMEOUT)
|
||||
sv = util.new_watchdog(config.ConnTimeout),
|
||||
api = util.new_watchdog(config.ConnTimeout)
|
||||
}
|
||||
|
||||
conn_wd.sv.cancel()
|
||||
@@ -96,8 +99,7 @@ local function main()
|
||||
|
||||
-- create network interface then setup comms
|
||||
local nic = network.nic(modem)
|
||||
local pocket_comms = pocket.comms(POCKET_VERSION, nic, config.PKT_CHANNEL, config.SVR_CHANNEL,
|
||||
config.CRD_CHANNEL, config.TRUSTED_RANGE, conn_wd.sv, conn_wd.api)
|
||||
local pocket_comms = pocket.comms(POCKET_VERSION, nic, conn_wd.sv, conn_wd.api)
|
||||
log.debug("startup> comms init")
|
||||
|
||||
-- base loop clock (2Hz, 10 ticks)
|
||||
|
||||
@@ -3,9 +3,9 @@
|
||||
--
|
||||
|
||||
local log = require("scada-common.log")
|
||||
local rsio = require("scada-common.rsio")
|
||||
local tcd = require("scada-common.tcd")
|
||||
local util = require("scada-common.util")
|
||||
local rsio = require("scada-common.rsio")
|
||||
|
||||
local core = require("graphics.core")
|
||||
|
||||
@@ -34,7 +34,8 @@ local RIGHT = core.ALIGN.RIGHT
|
||||
|
||||
-- changes to the config data/format to let the user know
|
||||
local changes = {
|
||||
{"v1.6.2", { "AuthKey minimum length is now 8 (if set)" } }
|
||||
{"v1.6.2", { "AuthKey minimum length is now 8 (if set)" } },
|
||||
{"v1.6.8", { "ConnTimeout can now have a fractional part" } }
|
||||
}
|
||||
|
||||
---@class plc_configurator
|
||||
@@ -92,13 +93,13 @@ local tmp_cfg = {
|
||||
Networked = false,
|
||||
UnitID = 0,
|
||||
EmerCoolEnable = false,
|
||||
EmerCoolSide = nil,
|
||||
EmerCoolColor = nil,
|
||||
SVR_Channel = nil,
|
||||
PLC_Channel = nil,
|
||||
ConnTimeout = nil,
|
||||
TrustedRange = nil,
|
||||
AuthKey = nil,
|
||||
EmerCoolSide = nil, ---@type string|nil
|
||||
EmerCoolColor = nil, ---@type color|nil
|
||||
SVR_Channel = nil, ---@type integer
|
||||
PLC_Channel = nil, ---@type integer
|
||||
ConnTimeout = nil, ---@type number
|
||||
TrustedRange = nil, ---@type number
|
||||
AuthKey = nil, ---@type string|nil
|
||||
LogMode = 0,
|
||||
LogPath = "",
|
||||
LogDebug = false,
|
||||
@@ -180,7 +181,7 @@ local function config_view(display)
|
||||
|
||||
local main_pane = MultiPane{parent=root_pane_div,x=1,y=1,panes={main_page,plc_cfg,net_cfg,log_cfg,summary,changelog}}
|
||||
|
||||
-- MAIN PAGE
|
||||
-- Main Page
|
||||
|
||||
local y_start = 5
|
||||
|
||||
@@ -211,7 +212,7 @@ local function config_view(display)
|
||||
PushButton{parent=main_page,x=2,y=17,min_width=6,text="Exit",callback=exit,fg_bg=cpair(colors.black,colors.red),active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=main_page,x=39,y=17,min_width=12,text="Change Log",callback=function()main_pane.set_value(6)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
|
||||
-- PLC CONFIG
|
||||
--#region PLC
|
||||
|
||||
local plc_c_1 = Div{parent=plc_cfg,x=2,y=4,width=49}
|
||||
local plc_c_2 = Div{parent=plc_cfg,x=2,y=4,width=49}
|
||||
@@ -232,14 +233,14 @@ local function config_view(display)
|
||||
plc_pane.set_value(2)
|
||||
end
|
||||
|
||||
PushButton{parent=plc_c_1,x=1,y=14,min_width=6,text="\x1b Back",callback=function()main_pane.set_value(1)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=plc_c_1,x=44,y=14,min_width=6,text="Next \x1a",callback=submit_networked,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=plc_c_1,x=1,y=14,text="\x1b Back",callback=function()main_pane.set_value(1)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=plc_c_1,x=44,y=14,text="Next \x1a",callback=submit_networked,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
|
||||
TextBox{parent=plc_c_2,x=1,y=1,height=1,text="Please enter the reactor unit ID for this PLC."}
|
||||
TextBox{parent=plc_c_2,x=1,y=3,height=3,text="If this is a networked PLC, currently only IDs 1 through 4 are acceptable.",fg_bg=g_lg_fg_bg}
|
||||
|
||||
TextBox{parent=plc_c_2,x=1,y=6,height=1,text="Unit #"}
|
||||
local u_id = NumberField{parent=plc_c_2,x=7,y=6,width=5,max_digits=3,default=ini_cfg.UnitID,min=1,fg_bg=bw_fg_bg}
|
||||
local u_id = NumberField{parent=plc_c_2,x=7,y=6,width=5,max_chars=3,default=ini_cfg.UnitID,min=1,fg_bg=bw_fg_bg}
|
||||
|
||||
local u_id_err = TextBox{parent=plc_c_2,x=8,y=14,height=1,width=35,text="Please set a unit ID.",fg_bg=cpair(colors.red,colors.lightGray),hidden=true}
|
||||
|
||||
@@ -252,10 +253,10 @@ local function config_view(display)
|
||||
else u_id_err.show() end
|
||||
end
|
||||
|
||||
PushButton{parent=plc_c_2,x=1,y=14,min_width=6,text="\x1b Back",callback=function()plc_pane.set_value(1)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=plc_c_2,x=44,y=14,min_width=6,text="Next \x1a",callback=submit_id,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=plc_c_2,x=1,y=14,text="\x1b Back",callback=function()plc_pane.set_value(1)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=plc_c_2,x=44,y=14,text="Next \x1a",callback=submit_id,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
|
||||
TextBox{parent=plc_c_3,x=1,y=1,height=4,text="When networked, the supervisor takes care of emergency coolant via RTUs. However, you can configure independent emergency coolant via the PLC. "}
|
||||
TextBox{parent=plc_c_3,x=1,y=1,height=4,text="When networked, the supervisor takes care of emergency coolant via RTUs. However, you can configure independent emergency coolant via the PLC."}
|
||||
TextBox{parent=plc_c_3,x=1,y=6,height=5,text="This independent control can be used with or without a supervisor. To configure, you would next select the interface of the redstone output connected to one or more mekanism pipes.",fg_bg=g_lg_fg_bg}
|
||||
|
||||
local en_em_cool = CheckBox{parent=plc_c_3,x=1,y=11,label="Enable PLC Emergency Coolant Control",default=ini_cfg.EmerCoolEnable,box_fg_bg=cpair(colors.orange,colors.black)}
|
||||
@@ -269,8 +270,8 @@ local function config_view(display)
|
||||
if tmp_cfg.EmerCoolEnable then plc_pane.set_value(4) else next_from_plc() end
|
||||
end
|
||||
|
||||
PushButton{parent=plc_c_3,x=1,y=14,min_width=6,text="\x1b Back",callback=function()plc_pane.set_value(2)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=plc_c_3,x=44,y=14,min_width=6,text="Next \x1a",callback=submit_en_emcool,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=plc_c_3,x=1,y=14,text="\x1b Back",callback=function()plc_pane.set_value(2)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=plc_c_3,x=44,y=14,text="Next \x1a",callback=submit_en_emcool,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
|
||||
TextBox{parent=plc_c_4,x=1,y=1,height=1,text="Emergency Coolant Redstone Output Side"}
|
||||
local side = Radio2D{parent=plc_c_4,x=1,y=2,rows=2,columns=3,default=side_to_idx(ini_cfg.EmerCoolSide),options=side_options,radio_colors=cpair(colors.lightGray,colors.black),select_color=colors.orange}
|
||||
@@ -286,10 +287,12 @@ local function config_view(display)
|
||||
next_from_plc()
|
||||
end
|
||||
|
||||
PushButton{parent=plc_c_4,x=1,y=14,min_width=6,text="\x1b Back",callback=function()plc_pane.set_value(3)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=plc_c_4,x=44,y=14,min_width=6,text="Next \x1a",callback=submit_emcool,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=plc_c_4,x=1,y=14,text="\x1b Back",callback=function()plc_pane.set_value(3)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=plc_c_4,x=44,y=14,text="Next \x1a",callback=submit_emcool,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
|
||||
-- NET CONFIG
|
||||
--#endregion
|
||||
|
||||
--#region Network
|
||||
|
||||
local net_c_1 = Div{parent=net_cfg,x=2,y=4,width=49}
|
||||
local net_c_2 = Div{parent=net_cfg,x=2,y=4,width=49}
|
||||
@@ -328,16 +331,16 @@ local function config_view(display)
|
||||
end
|
||||
end
|
||||
|
||||
PushButton{parent=net_c_1,x=1,y=14,min_width=6,text="\x1b Back",callback=function()main_pane.set_value(2)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=net_c_1,x=44,y=14,min_width=6,text="Next \x1a",callback=submit_channels,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=net_c_1,x=1,y=14,text="\x1b Back",callback=function()main_pane.set_value(2)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=net_c_1,x=44,y=14,text="Next \x1a",callback=submit_channels,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
|
||||
TextBox{parent=net_c_2,x=1,y=1,height=1,text="Connection Timeout"}
|
||||
local timeout = NumberField{parent=net_c_2,x=1,y=2,width=7,default=ini_cfg.ConnTimeout,min=2,max=25,fg_bg=bw_fg_bg}
|
||||
local timeout = NumberField{parent=net_c_2,x=1,y=2,width=7,default=ini_cfg.ConnTimeout,min=2,max=25,max_chars=6,max_frac_digits=2,allow_decimal=true,fg_bg=bw_fg_bg}
|
||||
TextBox{parent=net_c_2,x=9,y=2,height=2,text="seconds (default 5)",fg_bg=g_lg_fg_bg}
|
||||
TextBox{parent=net_c_2,x=1,y=3,height=4,text="You generally do not want or need to modify this. On slow servers, you can increase this to make the system wait longer before assuming a disconnection.",fg_bg=g_lg_fg_bg}
|
||||
|
||||
TextBox{parent=net_c_2,x=1,y=8,height=1,text="Trusted Range"}
|
||||
local range = NumberField{parent=net_c_2,x=1,y=9,width=10,default=ini_cfg.TrustedRange,min=0,max_digits=20,allow_decimal=true,fg_bg=bw_fg_bg}
|
||||
local range = NumberField{parent=net_c_2,x=1,y=9,width=10,default=ini_cfg.TrustedRange,min=0,max_chars=20,allow_decimal=true,fg_bg=bw_fg_bg}
|
||||
TextBox{parent=net_c_2,x=1,y=10,height=4,text="Setting this to a value larger than 0 prevents connections with devices that many meters (blocks) away in any direction.",fg_bg=g_lg_fg_bg}
|
||||
|
||||
local p2_err = TextBox{parent=net_c_2,x=8,y=14,height=1,width=35,text="",fg_bg=cpair(colors.red,colors.lightGray),hidden=true}
|
||||
@@ -359,8 +362,8 @@ local function config_view(display)
|
||||
end
|
||||
end
|
||||
|
||||
PushButton{parent=net_c_2,x=1,y=14,min_width=6,text="\x1b Back",callback=function()net_pane.set_value(1)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=net_c_2,x=44,y=14,min_width=6,text="Next \x1a",callback=submit_ct_tr,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=net_c_2,x=1,y=14,text="\x1b Back",callback=function()net_pane.set_value(1)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=net_c_2,x=44,y=14,text="Next \x1a",callback=submit_ct_tr,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
|
||||
TextBox{parent=net_c_3,x=1,y=1,height=2,text="Optionally, set the facility authentication key below. Do NOT use one of your passwords."}
|
||||
TextBox{parent=net_c_3,x=1,y=4,height=6,text="This enables verifying that messages are authentic, so it is intended for security on multiplayer servers. All devices on the same network MUST use the same key if any device has a key. This does result in some extra compution (can slow things down).",fg_bg=g_lg_fg_bg}
|
||||
@@ -386,10 +389,12 @@ local function config_view(display)
|
||||
else key_err.show() end
|
||||
end
|
||||
|
||||
PushButton{parent=net_c_3,x=1,y=14,min_width=6,text="\x1b Back",callback=function()net_pane.set_value(2)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=net_c_3,x=44,y=14,min_width=6,text="Next \x1a",callback=submit_auth,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=net_c_3,x=1,y=14,text="\x1b Back",callback=function()net_pane.set_value(2)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=net_c_3,x=44,y=14,text="Next \x1a",callback=submit_auth,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
|
||||
-- LOG CONFIG
|
||||
--#endregion
|
||||
|
||||
--#region Logging
|
||||
|
||||
local log_c_1 = Div{parent=log_cfg,x=2,y=4,width=49}
|
||||
|
||||
@@ -426,10 +431,12 @@ local function config_view(display)
|
||||
if tmp_cfg.Networked then main_pane.set_value(3) else main_pane.set_value(2) end
|
||||
end
|
||||
|
||||
PushButton{parent=log_c_1,x=1,y=14,min_width=6,text="\x1b Back",callback=back_from_log,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=log_c_1,x=44,y=14,min_width=6,text="Next \x1a",callback=submit_log,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=log_c_1,x=1,y=14,text="\x1b Back",callback=back_from_log,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=log_c_1,x=44,y=14,text="Next \x1a",callback=submit_log,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
|
||||
-- SUMMARY OF CHANGES
|
||||
--#endregion
|
||||
|
||||
--#region Summary and Saving
|
||||
|
||||
local sum_c_1 = Div{parent=summary,x=2,y=4,width=49}
|
||||
local sum_c_2 = Div{parent=summary,x=2,y=4,width=49}
|
||||
@@ -440,7 +447,7 @@ local function config_view(display)
|
||||
|
||||
TextBox{parent=summary,x=1,y=2,height=1,text=" Summary",fg_bg=cpair(colors.black,colors.green)}
|
||||
|
||||
local setting_list = ListBox{parent=sum_c_1,x=1,y=1,height=12,width=51,scroll_height=100,fg_bg=bw_fg_bg,nav_fg_bg=g_lg_fg_bg,nav_active=cpair(colors.black,colors.gray)}
|
||||
local setting_list = ListBox{parent=sum_c_1,x=1,y=1,height=12,width=49,scroll_height=100,fg_bg=bw_fg_bg,nav_fg_bg=g_lg_fg_bg,nav_active=cpair(colors.black,colors.gray)}
|
||||
|
||||
local function back_from_settings()
|
||||
if tool_ctl.viewing_config or tool_ctl.importing_legacy then
|
||||
@@ -462,9 +469,9 @@ local function config_view(display)
|
||||
local function save_and_continue()
|
||||
for k, v in pairs(tmp_cfg) do settings.set(k, v) end
|
||||
|
||||
if settings.save("reactor-plc.settings") then
|
||||
load_settings(ini_cfg)
|
||||
if settings.save("/reactor-plc.settings") then
|
||||
load_settings(settings_cfg, true)
|
||||
load_settings(ini_cfg)
|
||||
|
||||
try_set(networked, ini_cfg.Networked)
|
||||
try_set(u_id, ini_cfg.UnitID)
|
||||
@@ -494,7 +501,7 @@ local function config_view(display)
|
||||
end
|
||||
end
|
||||
|
||||
PushButton{parent=sum_c_1,x=1,y=14,min_width=6,text="\x1b Back",callback=back_from_settings,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=sum_c_1,x=1,y=14,text="\x1b Back",callback=back_from_settings,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
tool_ctl.show_key_btn = PushButton{parent=sum_c_1,x=8,y=14,min_width=17,text="Unhide Auth Key",callback=function()tool_ctl.show_auth_key()end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg,dis_fg_bg=cpair(colors.lightGray,colors.white)}
|
||||
tool_ctl.settings_apply = PushButton{parent=sum_c_1,x=43,y=14,min_width=7,text="Apply",callback=save_and_continue,fg_bg=cpair(colors.black,colors.green),active_fg_bg=btn_act_fg_bg}
|
||||
|
||||
@@ -524,13 +531,15 @@ local function config_view(display)
|
||||
PushButton{parent=sum_c_4,x=1,y=14,min_width=6,text="Home",callback=go_home,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=sum_c_4,x=44,y=14,min_width=6,text="Exit",callback=exit,fg_bg=cpair(colors.black,colors.red),active_fg_bg=cpair(colors.white,colors.gray)}
|
||||
|
||||
-- CONFIG CHANGE LOG
|
||||
--#endregion
|
||||
|
||||
-- Config Change Log
|
||||
|
||||
local cl = Div{parent=changelog,x=2,y=4,width=49}
|
||||
|
||||
TextBox{parent=changelog,x=1,y=2,height=1,text=" Config Change Log",fg_bg=bw_fg_bg}
|
||||
|
||||
local c_log = ListBox{parent=cl,x=1,y=1,height=12,width=51,scroll_height=100,fg_bg=bw_fg_bg,nav_fg_bg=g_lg_fg_bg,nav_active=cpair(colors.black,colors.gray)}
|
||||
local c_log = ListBox{parent=cl,x=1,y=1,height=12,width=49,scroll_height=100,fg_bg=bw_fg_bg,nav_fg_bg=g_lg_fg_bg,nav_active=cpair(colors.black,colors.gray)}
|
||||
|
||||
for _, change in ipairs(changes) do
|
||||
TextBox{parent=c_log,text=change[1],height=1,fg_bg=bw_fg_bg}
|
||||
@@ -541,7 +550,7 @@ local function config_view(display)
|
||||
end
|
||||
end
|
||||
|
||||
PushButton{parent=cl,x=1,y=14,min_width=6,text="\x1b Back",callback=function()main_pane.set_value(1)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=cl,x=1,y=14,text="\x1b Back",callback=function()main_pane.set_value(1)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
|
||||
-- set tool functions now that we have the elements
|
||||
|
||||
@@ -645,11 +654,12 @@ local function reset_term()
|
||||
end
|
||||
|
||||
-- run the reactor PLC configurator
|
||||
---@param ask_config? boolean indicate if this is being called by the PLC startup app due to an invalid configuration
|
||||
---@param ask_config? boolean indicate if this is being called by the startup app due to an invalid configuration
|
||||
function configurator.configure(ask_config)
|
||||
tool_ctl.ask_config = ask_config == true
|
||||
tool_ctl.has_config = load_settings(ini_cfg)
|
||||
|
||||
load_settings(settings_cfg, true)
|
||||
tool_ctl.has_config = load_settings(ini_cfg)
|
||||
|
||||
reset_term()
|
||||
|
||||
|
||||
@@ -70,9 +70,9 @@ function databus.tx_link_state(state)
|
||||
end
|
||||
|
||||
-- transmit reactor enable state across the bus
|
||||
---@param active boolean reactor active
|
||||
---@param active any reactor active
|
||||
function databus.tx_reactor_state(active)
|
||||
databus.ps.publish("reactor_active", active)
|
||||
databus.ps.publish("reactor_active", active == true)
|
||||
end
|
||||
|
||||
-- transmit RPS data across the bus
|
||||
|
||||
@@ -37,14 +37,17 @@ function plc.load_config()
|
||||
|
||||
config.Networked = settings.get("Networked")
|
||||
config.UnitID = settings.get("UnitID")
|
||||
|
||||
config.EmerCoolEnable = settings.get("EmerCoolEnable")
|
||||
config.EmerCoolSide = settings.get("EmerCoolSide")
|
||||
config.EmerCoolColor = settings.get("EmerCoolColor")
|
||||
|
||||
config.SVR_Channel = settings.get("SVR_Channel")
|
||||
config.PLC_Channel = settings.get("PLC_Channel")
|
||||
config.ConnTimeout = settings.get("ConnTimeout")
|
||||
config.TrustedRange = settings.get("TrustedRange")
|
||||
config.AuthKey = settings.get("AuthKey")
|
||||
|
||||
config.LogMode = settings.get("LogMode")
|
||||
config.LogPath = settings.get("LogPath")
|
||||
config.LogDebug = settings.get("LogDebug")
|
||||
@@ -58,7 +61,7 @@ function plc.load_config()
|
||||
if config.Networked == true then
|
||||
cfv.assert_channel(config.SVR_Channel)
|
||||
cfv.assert_channel(config.PLC_Channel)
|
||||
cfv.assert_type_int(config.ConnTimeout)
|
||||
cfv.assert_type_num(config.ConnTimeout)
|
||||
cfv.assert_min(config.ConnTimeout, 2)
|
||||
cfv.assert_type_num(config.TrustedRange)
|
||||
cfv.assert_min(config.TrustedRange, 0)
|
||||
@@ -71,6 +74,7 @@ function plc.load_config()
|
||||
end
|
||||
|
||||
cfv.assert_type_int(config.LogMode)
|
||||
cfv.assert_range(config.LogMode, 0, 1)
|
||||
cfv.assert_type_str(config.LogPath)
|
||||
cfv.assert_type_bool(config.LogDebug)
|
||||
|
||||
@@ -125,6 +129,21 @@ function plc.rps_init(reactor, is_formed)
|
||||
end
|
||||
end
|
||||
|
||||
-- check if the result of a peripheral call was OK, handle the failure if not
|
||||
---@nodiscard
|
||||
---@param result any PPM function call result
|
||||
---@return boolean succeeded if the result is OK, false if it was a PPM failure
|
||||
local function _check_and_handle_ppm_call(result)
|
||||
if result == ppm.ACCESS_FAULT then
|
||||
_set_fault()
|
||||
elseif result == ppm.UNDEFINED_FIELD then
|
||||
_set_fault()
|
||||
self.formed = false
|
||||
else return true end
|
||||
|
||||
return false
|
||||
end
|
||||
|
||||
-- set emergency coolant control (if configured)
|
||||
---@param state boolean true to enable emergency coolant, false to disable
|
||||
local function _set_emer_cool(state)
|
||||
@@ -163,25 +182,20 @@ function plc.rps_init(reactor, is_formed)
|
||||
-- check if the reactor is formed
|
||||
local function _is_formed()
|
||||
local formed = reactor.isFormed()
|
||||
if formed == ppm.ACCESS_FAULT then
|
||||
-- lost the peripheral or terminated, handled later
|
||||
_set_fault()
|
||||
else
|
||||
if _check_and_handle_ppm_call(formed) then
|
||||
self.formed = formed
|
||||
end
|
||||
|
||||
if not self.state[state_keys.sys_fail] then
|
||||
self.state[state_keys.sys_fail] = not formed
|
||||
end
|
||||
-- always update, since some ppm failures constitute not being formed
|
||||
if not self.state[state_keys.sys_fail] then
|
||||
self.state[state_keys.sys_fail] = not self.formed
|
||||
end
|
||||
end
|
||||
|
||||
-- check if the reactor is force disabled
|
||||
local function _is_force_disabled()
|
||||
local disabled = reactor.isForceDisabled()
|
||||
if disabled == ppm.ACCESS_FAULT then
|
||||
-- lost the peripheral or terminated, handled later
|
||||
_set_fault()
|
||||
else
|
||||
if _check_and_handle_ppm_call(disabled) then
|
||||
self.force_disabled = disabled
|
||||
|
||||
if not self.state[state_keys.force_disabled] then
|
||||
@@ -193,22 +207,16 @@ function plc.rps_init(reactor, is_formed)
|
||||
-- check for high damage
|
||||
local function _high_damage()
|
||||
local damage_percent = reactor.getDamagePercent()
|
||||
if damage_percent == ppm.ACCESS_FAULT then
|
||||
-- lost the peripheral or terminated, handled later
|
||||
_set_fault()
|
||||
elseif not self.state[state_keys.high_dmg] then
|
||||
if _check_and_handle_ppm_call(damage_percent) and not self.state[state_keys.high_dmg] then
|
||||
self.state[state_keys.high_dmg] = damage_percent >= RPS_LIMITS.MAX_DAMAGE_PERCENT
|
||||
end
|
||||
end
|
||||
|
||||
-- check if the reactor is at a critically high temperature
|
||||
local function _high_temp()
|
||||
-- mekanism: MAX_DAMAGE_TEMPERATURE = 1_200
|
||||
-- mekanism: MAX_DAMAGE_TEMPERATURE = 1200K
|
||||
local temp = reactor.getTemperature()
|
||||
if temp == ppm.ACCESS_FAULT then
|
||||
-- lost the peripheral or terminated, handled later
|
||||
_set_fault()
|
||||
elseif not self.state[state_keys.high_temp] then
|
||||
if _check_and_handle_ppm_call(temp) and not self.state[state_keys.high_temp] then
|
||||
self.state[state_keys.high_temp] = temp >= RPS_LIMITS.MAX_DAMAGE_TEMPERATURE
|
||||
end
|
||||
end
|
||||
@@ -216,10 +224,7 @@ function plc.rps_init(reactor, is_formed)
|
||||
-- check if there is very low coolant
|
||||
local function _low_coolant()
|
||||
local coolant_filled = reactor.getCoolantFilledPercentage()
|
||||
if coolant_filled == ppm.ACCESS_FAULT then
|
||||
-- lost the peripheral or terminated, handled later
|
||||
_set_fault()
|
||||
elseif not self.state[state_keys.low_coolant] then
|
||||
if _check_and_handle_ppm_call(coolant_filled) and not self.state[state_keys.low_coolant] then
|
||||
self.state[state_keys.low_coolant] = coolant_filled < RPS_LIMITS.MIN_COOLANT_FILL
|
||||
end
|
||||
end
|
||||
@@ -227,10 +232,7 @@ function plc.rps_init(reactor, is_formed)
|
||||
-- check for excess waste (>80% filled)
|
||||
local function _excess_waste()
|
||||
local w_filled = reactor.getWasteFilledPercentage()
|
||||
if w_filled == ppm.ACCESS_FAULT then
|
||||
-- lost the peripheral or terminated, handled later
|
||||
_set_fault()
|
||||
elseif not self.state[state_keys.ex_waste] then
|
||||
if _check_and_handle_ppm_call(w_filled) and not self.state[state_keys.ex_waste] then
|
||||
self.state[state_keys.ex_waste] = w_filled > RPS_LIMITS.MAX_WASTE_FILL
|
||||
end
|
||||
end
|
||||
@@ -238,10 +240,7 @@ function plc.rps_init(reactor, is_formed)
|
||||
-- check for heated coolant backup (>95% filled)
|
||||
local function _excess_heated_coolant()
|
||||
local hc_filled = reactor.getHeatedCoolantFilledPercentage()
|
||||
if hc_filled == ppm.ACCESS_FAULT then
|
||||
-- lost the peripheral or terminated, handled later
|
||||
_set_fault()
|
||||
elseif not self.state[state_keys.ex_hcoolant] then
|
||||
if _check_and_handle_ppm_call(hc_filled) and not self.state[state_keys.ex_hcoolant] then
|
||||
self.state[state_keys.ex_hcoolant] = hc_filled > RPS_LIMITS.MAX_HEATED_COLLANT_FILL
|
||||
end
|
||||
end
|
||||
@@ -249,10 +248,7 @@ function plc.rps_init(reactor, is_formed)
|
||||
-- check if there is no fuel
|
||||
local function _insufficient_fuel()
|
||||
local fuel = reactor.getFuelFilledPercentage()
|
||||
if fuel == ppm.ACCESS_FAULT then
|
||||
-- lost the peripheral or terminated, handled later
|
||||
_set_fault()
|
||||
elseif not self.state[state_keys.no_fuel] then
|
||||
if _check_and_handle_ppm_call(fuel) and not self.state[state_keys.no_fuel] then
|
||||
self.state[state_keys.no_fuel] = fuel <= RPS_LIMITS.NO_FUEL_FILL
|
||||
end
|
||||
end
|
||||
@@ -473,13 +469,22 @@ function plc.rps_init(reactor, is_formed)
|
||||
self.tripped = false
|
||||
self.trip_cause = RPS_TRIP_CAUSE.OK
|
||||
|
||||
for i = 1, #self.state do
|
||||
self.state[i] = false
|
||||
end
|
||||
for i = 1, #self.state do self.state[i] = false end
|
||||
|
||||
if not quiet then log.info("RPS: reset") end
|
||||
end
|
||||
|
||||
-- partial RPS reset that only clears fault and sys_fail
|
||||
function public.reset_formed()
|
||||
self.tripped = false
|
||||
self.trip_cause = RPS_TRIP_CAUSE.OK
|
||||
|
||||
self.state[state_keys.fault] = false
|
||||
self.state[state_keys.sys_fail] = false
|
||||
|
||||
log.info("RPS: partial reset on formed")
|
||||
end
|
||||
|
||||
-- reset the automatic and timeout trip flags, then clear trip if that was the trip cause
|
||||
function public.auto_reset()
|
||||
self.state[state_keys.automatic] = false
|
||||
|
||||
@@ -18,7 +18,7 @@ local plc = require("reactor-plc.plc")
|
||||
local renderer = require("reactor-plc.renderer")
|
||||
local threads = require("reactor-plc.threads")
|
||||
|
||||
local R_PLC_VERSION = "v1.6.4"
|
||||
local R_PLC_VERSION = "v1.6.14"
|
||||
|
||||
local println = util.println
|
||||
local println_ts = util.println_ts
|
||||
@@ -31,9 +31,13 @@ if not plc.load_config() then
|
||||
-- try to reconfigure (user action)
|
||||
local success, error = configure.configure(true)
|
||||
if success then
|
||||
assert(plc.load_config(), "failed to load valid reactor PLC configuration")
|
||||
if not plc.load_config() then
|
||||
println("failed to load a valid configuration, please reconfigure")
|
||||
return
|
||||
end
|
||||
else
|
||||
assert(success, "reactor PLC configuration error: " .. error)
|
||||
println("configuration error: " .. error)
|
||||
return
|
||||
end
|
||||
end
|
||||
|
||||
@@ -131,15 +135,22 @@ local function main()
|
||||
|
||||
-- we need a reactor, can at least do some things even if it isn't formed though
|
||||
if plc_state.no_reactor then
|
||||
println("init> fission reactor not found");
|
||||
println("init> fission reactor not found")
|
||||
log.warning("init> no reactor on startup")
|
||||
|
||||
plc_state.init_ok = false
|
||||
plc_state.degraded = true
|
||||
elseif not smem_dev.reactor.isFormed() then
|
||||
println("init> fission reactor not formed");
|
||||
println("init> fission reactor is not formed")
|
||||
log.warning("init> reactor logic adapter present, but reactor is not formed")
|
||||
|
||||
plc_state.degraded = true
|
||||
plc_state.reactor_formed = false
|
||||
elseif smem_dev.reactor.getStatus() == ppm.UNDEFINED_FIELD then
|
||||
-- reactor formed after ppm.mount_all was called
|
||||
println("init> fission reactor was not formed")
|
||||
log.warning("init> reactor reported formed, but multiblock functions are not available")
|
||||
|
||||
plc_state.degraded = true
|
||||
plc_state.reactor_formed = false
|
||||
end
|
||||
|
||||
@@ -125,9 +125,8 @@ function threads.thread__main(smem, init)
|
||||
plc_comms.reconnect_reactor(plc_dev.reactor)
|
||||
end
|
||||
|
||||
-- reset RPS for newly connected reactor
|
||||
-- without this, is_formed will be out of date and cause it to think its no longer formed again
|
||||
rps.reset()
|
||||
-- partial reset of RPS, specific to becoming formed
|
||||
rps.reset_formed()
|
||||
else
|
||||
-- fully lost the reactor now :(
|
||||
println_ts("reactor lost (failed reconnect)!")
|
||||
@@ -173,7 +172,8 @@ function threads.thread__main(smem, init)
|
||||
plc_state.degraded = true
|
||||
elseif networked and type == "modem" then
|
||||
-- we only care if this is our wireless modem
|
||||
if nic.is_modem(device) then
|
||||
-- note, check init_ok first since nic will be nil if it is false
|
||||
if plc_state.init_ok and nic.is_modem(device) then
|
||||
nic.disconnect()
|
||||
|
||||
println_ts("comms modem disconnected!")
|
||||
@@ -193,7 +193,7 @@ function threads.thread__main(smem, init)
|
||||
end
|
||||
end
|
||||
else
|
||||
log.warning("non-comms modem disconnected")
|
||||
log.warning("a modem was disconnected")
|
||||
end
|
||||
end
|
||||
end
|
||||
@@ -230,12 +230,12 @@ function threads.thread__main(smem, init)
|
||||
plc_comms.reconnect_reactor(plc_dev.reactor)
|
||||
end
|
||||
|
||||
-- reset RPS for newly connected reactor
|
||||
-- without this, is_formed will be out of date and cause it to think its no longer formed again
|
||||
rps.reset()
|
||||
-- partial reset of RPS, specific to becoming formed
|
||||
rps.reset_formed()
|
||||
end
|
||||
elseif networked and type == "modem" then
|
||||
if device.isWireless() and not nic.is_connected() then
|
||||
-- note, check init_ok first since nic will be nil if it is false
|
||||
if device.isWireless() and not (plc_state.init_ok and nic.is_connected()) then
|
||||
-- reconnected modem
|
||||
plc_dev.modem = device
|
||||
plc_state.no_modem = false
|
||||
|
||||
@@ -3,10 +3,10 @@
|
||||
--
|
||||
|
||||
local log = require("scada-common.log")
|
||||
local ppm = require("scada-common.ppm")
|
||||
local rsio = require("scada-common.rsio")
|
||||
local tcd = require("scada-common.tcd")
|
||||
local util = require("scada-common.util")
|
||||
local ppm = require("scada-common.ppm")
|
||||
|
||||
local core = require("graphics.core")
|
||||
|
||||
@@ -72,7 +72,9 @@ assert(#PORT_DESC == rsio.NUM_PORTS)
|
||||
assert(#PORT_DSGN == rsio.NUM_PORTS)
|
||||
|
||||
-- changes to the config data/format to let the user know
|
||||
local changes = {}
|
||||
local changes = {
|
||||
{"v1.7.9", { "ConnTimeout can now have a fractional part" } }
|
||||
}
|
||||
|
||||
---@class rtu_rs_definition
|
||||
---@field unit integer|nil
|
||||
@@ -125,6 +127,7 @@ local tool_ctl = {
|
||||
importing_any_dc = false,
|
||||
peri_cfg_editing = false, ---@type string|false
|
||||
peri_cfg_manual = false,
|
||||
rs_cfg_port = IO.F_SCRAM, ---@type IO_PORT
|
||||
rs_cfg_editing = false, ---@type integer|false
|
||||
|
||||
view_gw_cfg = nil, ---@type graphics_element
|
||||
@@ -161,6 +164,7 @@ local tool_ctl = {
|
||||
rs_cfg_selection = nil, ---@type graphics_element
|
||||
rs_cfg_unit_l = nil, ---@type graphics_element
|
||||
rs_cfg_unit = nil, ---@type graphics_element
|
||||
rs_cfg_side_l = nil, ---@type graphics_element
|
||||
rs_cfg_color = nil, ---@type graphics_element
|
||||
rs_cfg_shortcut = nil ---@type graphics_element
|
||||
}
|
||||
@@ -170,11 +174,11 @@ local tmp_cfg = {
|
||||
SpeakerVolume = 1.0,
|
||||
Peripherals = {},
|
||||
Redstone = {},
|
||||
SVR_Channel = nil,
|
||||
RTU_Channel = nil,
|
||||
ConnTimeout = nil,
|
||||
TrustedRange = nil,
|
||||
AuthKey = nil,
|
||||
SVR_Channel = nil, ---@type integer
|
||||
RTU_Channel = nil, ---@type integer
|
||||
ConnTimeout = nil, ---@type number
|
||||
TrustedRange = nil, ---@type number
|
||||
AuthKey = nil, ---@type string|nil
|
||||
LogMode = 0,
|
||||
LogPath = "",
|
||||
LogDebug = false
|
||||
@@ -269,7 +273,7 @@ local function config_view(display)
|
||||
|
||||
local main_pane = MultiPane{parent=root_pane_div,x=1,y=1,panes={main_page,spkr_cfg,net_cfg,log_cfg,summary,changelog,peri_cfg,rs_cfg}}
|
||||
|
||||
--#region MAIN PAGE
|
||||
--#region Main Page
|
||||
|
||||
local y_start = 2
|
||||
|
||||
@@ -320,7 +324,7 @@ local function config_view(display)
|
||||
|
||||
--#endregion
|
||||
|
||||
--#region SPEAKER CONFIG
|
||||
--#region Speakers
|
||||
|
||||
local spkr_c = Div{parent=spkr_cfg,x=2,y=4,width=49}
|
||||
|
||||
@@ -329,7 +333,7 @@ local function config_view(display)
|
||||
TextBox{parent=spkr_c,x=1,y=1,height=2,text="Speakers can be connected to this RTU gateway without RTU unit configuration entries."}
|
||||
TextBox{parent=spkr_c,x=1,y=4,height=3,text="You can change the speaker audio volume from the default. The range is 0.0 to 3.0, where 1.0 is standard volume."}
|
||||
|
||||
local s_vol = NumberField{parent=spkr_c,x=1,y=8,width=9,max_digits=7,allow_decimal=true,default=ini_cfg.SpeakerVolume,min=0,max=3,fg_bg=bw_fg_bg}
|
||||
local s_vol = NumberField{parent=spkr_c,x=1,y=8,width=9,max_chars=7,allow_decimal=true,default=ini_cfg.SpeakerVolume,min=0,max=3,fg_bg=bw_fg_bg}
|
||||
|
||||
TextBox{parent=spkr_c,x=1,y=10,height=3,text="Note: alarm sine waves are at half scale so that multiple will be required to reach full scale.",fg_bg=g_lg_fg_bg}
|
||||
|
||||
@@ -344,12 +348,12 @@ local function config_view(display)
|
||||
else s_vol_err.show() end
|
||||
end
|
||||
|
||||
PushButton{parent=spkr_c,x=1,y=14,min_width=6,text="\x1b Back",callback=function()main_pane.set_value(1)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=spkr_c,x=44,y=14,min_width=6,text="Next \x1a",callback=submit_vol,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=spkr_c,x=1,y=14,text="\x1b Back",callback=function()main_pane.set_value(1)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=spkr_c,x=44,y=14,text="Next \x1a",callback=submit_vol,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
|
||||
--#endregion
|
||||
|
||||
--#region NET CONFIG
|
||||
--#region Network
|
||||
|
||||
local net_c_1 = Div{parent=net_cfg,x=2,y=4,width=49}
|
||||
local net_c_2 = Div{parent=net_cfg,x=2,y=4,width=49}
|
||||
@@ -388,16 +392,16 @@ local function config_view(display)
|
||||
end
|
||||
end
|
||||
|
||||
PushButton{parent=net_c_1,x=1,y=14,min_width=6,text="\x1b Back",callback=function()main_pane.set_value(2)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=net_c_1,x=44,y=14,min_width=6,text="Next \x1a",callback=submit_channels,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=net_c_1,x=1,y=14,text="\x1b Back",callback=function()main_pane.set_value(2)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=net_c_1,x=44,y=14,text="Next \x1a",callback=submit_channels,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
|
||||
TextBox{parent=net_c_2,x=1,y=1,height=1,text="Connection Timeout"}
|
||||
local timeout = NumberField{parent=net_c_2,x=1,y=2,width=7,default=ini_cfg.ConnTimeout,min=2,max=25,fg_bg=bw_fg_bg}
|
||||
local timeout = NumberField{parent=net_c_2,x=1,y=2,width=7,default=ini_cfg.ConnTimeout,min=2,max=25,max_chars=6,max_frac_digits=2,allow_decimal=true,fg_bg=bw_fg_bg}
|
||||
TextBox{parent=net_c_2,x=9,y=2,height=2,text="seconds (default 5)",fg_bg=g_lg_fg_bg}
|
||||
TextBox{parent=net_c_2,x=1,y=3,height=4,text="You generally do not want or need to modify this. On slow servers, you can increase this to make the system wait longer before assuming a disconnection.",fg_bg=g_lg_fg_bg}
|
||||
|
||||
TextBox{parent=net_c_2,x=1,y=8,height=1,text="Trusted Range"}
|
||||
local range = NumberField{parent=net_c_2,x=1,y=9,width=10,default=ini_cfg.TrustedRange,min=0,max_digits=20,allow_decimal=true,fg_bg=bw_fg_bg}
|
||||
local range = NumberField{parent=net_c_2,x=1,y=9,width=10,default=ini_cfg.TrustedRange,min=0,max_chars=20,allow_decimal=true,fg_bg=bw_fg_bg}
|
||||
TextBox{parent=net_c_2,x=1,y=10,height=4,text="Setting this to a value larger than 0 prevents connections with devices that many meters (blocks) away in any direction.",fg_bg=g_lg_fg_bg}
|
||||
|
||||
local p2_err = TextBox{parent=net_c_2,x=8,y=14,height=1,width=35,text="",fg_bg=cpair(colors.red,colors.lightGray),hidden=true}
|
||||
@@ -419,8 +423,8 @@ local function config_view(display)
|
||||
end
|
||||
end
|
||||
|
||||
PushButton{parent=net_c_2,x=1,y=14,min_width=6,text="\x1b Back",callback=function()net_pane.set_value(1)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=net_c_2,x=44,y=14,min_width=6,text="Next \x1a",callback=submit_ct_tr,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=net_c_2,x=1,y=14,text="\x1b Back",callback=function()net_pane.set_value(1)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=net_c_2,x=44,y=14,text="Next \x1a",callback=submit_ct_tr,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
|
||||
TextBox{parent=net_c_3,x=1,y=1,height=2,text="Optionally, set the facility authentication key below. Do NOT use one of your passwords."}
|
||||
TextBox{parent=net_c_3,x=1,y=4,height=6,text="This enables verifying that messages are authentic, so it is intended for security on multiplayer servers. All devices on the same network MUST use the same key if any device has a key. This does result in some extra compution (can slow things down).",fg_bg=g_lg_fg_bg}
|
||||
@@ -446,12 +450,12 @@ local function config_view(display)
|
||||
else key_err.show() end
|
||||
end
|
||||
|
||||
PushButton{parent=net_c_3,x=1,y=14,min_width=6,text="\x1b Back",callback=function()net_pane.set_value(2)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=net_c_3,x=44,y=14,min_width=6,text="Next \x1a",callback=submit_auth,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=net_c_3,x=1,y=14,text="\x1b Back",callback=function()net_pane.set_value(2)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=net_c_3,x=44,y=14,text="Next \x1a",callback=submit_auth,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
|
||||
--#endregion
|
||||
|
||||
--#region LOG CONFIG
|
||||
--#region Logging
|
||||
|
||||
local log_c_1 = Div{parent=log_cfg,x=2,y=4,width=49}
|
||||
|
||||
@@ -485,12 +489,12 @@ local function config_view(display)
|
||||
else path_err.show() end
|
||||
end
|
||||
|
||||
PushButton{parent=log_c_1,x=1,y=14,min_width=6,text="\x1b Back",callback=function()main_pane.set_value(3)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=log_c_1,x=44,y=14,min_width=6,text="Next \x1a",callback=submit_log,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=log_c_1,x=1,y=14,text="\x1b Back",callback=function()main_pane.set_value(3)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=log_c_1,x=44,y=14,text="Next \x1a",callback=submit_log,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
|
||||
--#endregion
|
||||
|
||||
--#region SUMMARY OF CHANGES
|
||||
--#region Summary and Saving
|
||||
|
||||
local sum_c_1 = Div{parent=summary,x=2,y=4,width=49}
|
||||
local sum_c_2 = Div{parent=summary,x=2,y=4,width=49}
|
||||
@@ -504,7 +508,7 @@ local function config_view(display)
|
||||
|
||||
TextBox{parent=summary,x=1,y=2,height=1,text=" Summary",fg_bg=cpair(colors.black,colors.green)}
|
||||
|
||||
local setting_list = ListBox{parent=sum_c_1,x=1,y=1,height=12,width=51,scroll_height=100,fg_bg=bw_fg_bg,nav_fg_bg=g_lg_fg_bg,nav_active=cpair(colors.black,colors.gray)}
|
||||
local setting_list = ListBox{parent=sum_c_1,x=1,y=1,height=12,width=49,scroll_height=100,fg_bg=bw_fg_bg,nav_fg_bg=g_lg_fg_bg,nav_active=cpair(colors.black,colors.gray)}
|
||||
|
||||
local function back_from_settings()
|
||||
if tool_ctl.viewing_config or tool_ctl.importing_legacy then
|
||||
@@ -531,9 +535,13 @@ local function config_view(display)
|
||||
if not (exclude_conns and (k == "Peripherals" or k == "Redstone")) then settings.set(k, v) end
|
||||
end
|
||||
|
||||
if settings.save("rtu.settings") then
|
||||
load_settings(ini_cfg)
|
||||
-- always set these if missing
|
||||
if settings.get("Peripherals") == nil then settings.set("Peripherals", {}) end
|
||||
if settings.get("Redstone") == nil then settings.set("Redstone", {}) end
|
||||
|
||||
if settings.save("/rtu.settings") then
|
||||
load_settings(settings_cfg, true)
|
||||
load_settings(ini_cfg)
|
||||
|
||||
try_set(s_vol, ini_cfg.SpeakerVolume)
|
||||
try_set(svr_chan, ini_cfg.SVR_Channel)
|
||||
@@ -563,27 +571,27 @@ local function config_view(display)
|
||||
else sum_pane.set_value(6) end
|
||||
end
|
||||
|
||||
PushButton{parent=sum_c_1,x=1,y=14,min_width=6,text="\x1b Back",callback=back_from_settings,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=sum_c_1,x=1,y=14,text="\x1b Back",callback=back_from_settings,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
tool_ctl.show_key_btn = PushButton{parent=sum_c_1,x=8,y=14,min_width=17,text="Unhide Auth Key",callback=function()tool_ctl.show_auth_key()end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg,dis_fg_bg=cpair(colors.lightGray,colors.white)}
|
||||
tool_ctl.settings_apply = PushButton{parent=sum_c_1,x=43,y=14,min_width=7,text="Apply",callback=function()save_and_continue(true)end,fg_bg=cpair(colors.black,colors.green),active_fg_bg=btn_act_fg_bg}
|
||||
tool_ctl.settings_confirm = PushButton{parent=sum_c_1,x=41,y=14,min_width=9,text="Confirm",callback=function()sum_pane.set_value(2)end,fg_bg=cpair(colors.black,colors.green),active_fg_bg=btn_act_fg_bg}
|
||||
tool_ctl.settings_confirm.hide()
|
||||
|
||||
TextBox{parent=sum_c_2,x=1,y=1,height=1,text="The following peripherals will be imported:"}
|
||||
local peri_import_list = ListBox{parent=sum_c_2,x=1,y=3,height=10,width=51,scroll_height=1000,fg_bg=bw_fg_bg,nav_fg_bg=g_lg_fg_bg,nav_active=cpair(colors.black,colors.gray)}
|
||||
local peri_import_list = ListBox{parent=sum_c_2,x=1,y=3,height=10,width=49,scroll_height=1000,fg_bg=bw_fg_bg,nav_fg_bg=g_lg_fg_bg,nav_active=cpair(colors.black,colors.gray)}
|
||||
|
||||
PushButton{parent=sum_c_2,x=1,y=14,min_width=6,text="\x1b Back",callback=function()sum_pane.set_value(1)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=sum_c_2,x=1,y=14,text="\x1b Back",callback=function()sum_pane.set_value(1)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=sum_c_2,x=41,y=14,min_width=9,text="Confirm",callback=function()sum_pane.set_value(3)end,fg_bg=cpair(colors.black,colors.green),active_fg_bg=btn_act_fg_bg}
|
||||
|
||||
TextBox{parent=sum_c_3,x=1,y=1,height=1,text="The following redstone entries will be imported:"}
|
||||
local rs_import_list = ListBox{parent=sum_c_3,x=1,y=3,height=10,width=51,scroll_height=1000,fg_bg=bw_fg_bg,nav_fg_bg=g_lg_fg_bg,nav_active=cpair(colors.black,colors.gray)}
|
||||
local rs_import_list = ListBox{parent=sum_c_3,x=1,y=3,height=10,width=49,scroll_height=1000,fg_bg=bw_fg_bg,nav_fg_bg=g_lg_fg_bg,nav_active=cpair(colors.black,colors.gray)}
|
||||
|
||||
PushButton{parent=sum_c_3,x=1,y=14,min_width=6,text="\x1b Back",callback=function()sum_pane.set_value(2)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=sum_c_3,x=1,y=14,text="\x1b Back",callback=function()sum_pane.set_value(2)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=sum_c_3,x=43,y=14,min_width=7,text="Apply",callback=save_and_continue,fg_bg=cpair(colors.black,colors.green),active_fg_bg=btn_act_fg_bg}
|
||||
|
||||
TextBox{parent=sum_c_4,x=1,y=1,height=1,text="Settings saved!"}
|
||||
PushButton{parent=sum_c_4,x=1,y=14,min_width=6,text="Home",callback=function()tool_ctl.go_home()end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=sum_c_4,x=44,y=14,min_width=6,text="Exit",callback=exit,fg_bg=cpair(colors.black,colors.red),active_fg_bg=cpair(colors.white,colors.gray)}
|
||||
PushButton{parent=sum_c_4,x=1,y=14,min_width=6,text="Exit",callback=exit,fg_bg=cpair(colors.black,colors.red),active_fg_bg=cpair(colors.white,colors.gray)}
|
||||
PushButton{parent=sum_c_4,x=44,y=14,min_width=6,text="Home",callback=function()tool_ctl.go_home()end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
|
||||
TextBox{parent=sum_c_5,x=1,y=1,height=2,text="The old config.lua file will now be deleted, then the configurator will exit."}
|
||||
|
||||
@@ -601,18 +609,18 @@ local function config_view(display)
|
||||
|
||||
TextBox{parent=sum_c_7,x=1,y=1,height=8,text="Warning!\n\nSome of the devices in your old config file aren't currently connected. If the device isn't connected, the options can't be properly validated. Please either connect your devices and try again or complete the import without validation on those entry's settings."}
|
||||
TextBox{parent=sum_c_7,x=1,y=10,height=3,text="Afterwards, either (a) edit then save entries for currently disconnected devices to properly configure or (b) delete those entries."}
|
||||
PushButton{parent=sum_c_7,x=1,y=14,min_width=6,text="\x1b Back",callback=function()tool_ctl.go_home()end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=sum_c_7,x=1,y=14,text="\x1b Back",callback=function()tool_ctl.go_home()end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=sum_c_7,x=41,y=14,min_width=9,text="Confirm",callback=function()sum_pane.set_value(1)end,fg_bg=cpair(colors.black,colors.orange),active_fg_bg=btn_act_fg_bg}
|
||||
|
||||
--#endregion
|
||||
|
||||
--#region CONFIG CHANGE LOG
|
||||
--#region Config Change Log
|
||||
|
||||
local cl = Div{parent=changelog,x=2,y=4,width=49}
|
||||
|
||||
TextBox{parent=changelog,x=1,y=2,height=1,text=" Config Change Log",fg_bg=bw_fg_bg}
|
||||
|
||||
local c_log = ListBox{parent=cl,x=1,y=1,height=12,width=51,scroll_height=100,fg_bg=bw_fg_bg,nav_fg_bg=g_lg_fg_bg,nav_active=cpair(colors.black,colors.gray)}
|
||||
local c_log = ListBox{parent=cl,x=1,y=1,height=12,width=49,scroll_height=100,fg_bg=bw_fg_bg,nav_fg_bg=g_lg_fg_bg,nav_active=cpair(colors.black,colors.gray)}
|
||||
|
||||
for _, change in ipairs(changes) do
|
||||
TextBox{parent=c_log,text=change[1],height=1,fg_bg=bw_fg_bg}
|
||||
@@ -623,11 +631,11 @@ local function config_view(display)
|
||||
end
|
||||
end
|
||||
|
||||
PushButton{parent=cl,x=1,y=14,min_width=6,text="\x1b Back",callback=function()main_pane.set_value(1)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=cl,x=1,y=14,text="\x1b Back",callback=function()main_pane.set_value(1)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
|
||||
--#endregion
|
||||
|
||||
--#region DEVICES
|
||||
--#region Peripherals
|
||||
|
||||
local peri_c_1 = Div{parent=peri_cfg,x=2,y=4,width=49}
|
||||
local peri_c_2 = Div{parent=peri_cfg,x=2,y=4,width=49}
|
||||
@@ -641,7 +649,7 @@ local function config_view(display)
|
||||
|
||||
TextBox{parent=peri_cfg,x=1,y=2,height=1,text=" Peripheral Connections",fg_bg=cpair(colors.black,colors.purple)}
|
||||
|
||||
local peri_list = ListBox{parent=peri_c_1,x=1,y=1,height=12,width=51,scroll_height=1000,fg_bg=bw_fg_bg,nav_fg_bg=g_lg_fg_bg,nav_active=cpair(colors.black,colors.gray)}
|
||||
local peri_list = ListBox{parent=peri_c_1,x=1,y=1,height=12,width=49,scroll_height=1000,fg_bg=bw_fg_bg,nav_fg_bg=g_lg_fg_bg,nav_active=cpair(colors.black,colors.gray)}
|
||||
|
||||
local function peri_revert()
|
||||
tmp_cfg.Peripherals = deep_copy_peri(ini_cfg.Peripherals)
|
||||
@@ -651,31 +659,31 @@ local function config_view(display)
|
||||
local function peri_apply()
|
||||
settings.set("Peripherals", tmp_cfg.Peripherals)
|
||||
|
||||
if settings.save("rtu.settings") then
|
||||
load_settings(ini_cfg)
|
||||
if settings.save("/rtu.settings") then
|
||||
load_settings(settings_cfg, true)
|
||||
load_settings(ini_cfg)
|
||||
peri_pane.set_value(5)
|
||||
else
|
||||
peri_pane.set_value(6)
|
||||
end
|
||||
end
|
||||
|
||||
PushButton{parent=peri_c_1,x=1,y=14,min_width=6,text="\x1b Back",callback=function()main_pane.set_value(1)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=peri_c_1,x=1,y=14,text="\x1b Back",callback=function()main_pane.set_value(1)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=peri_c_1,x=8,y=14,min_width=16,text="Revert Changes",callback=peri_revert,fg_bg=cpair(colors.black,colors.yellow),active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=peri_c_1,x=35,y=14,min_width=7,text="Add +",callback=function()peri_pane.set_value(2)end,fg_bg=cpair(colors.black,colors.blue),active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=peri_c_1,x=43,y=14,min_width=7,text="Apply",callback=peri_apply,fg_bg=cpair(colors.black,colors.green),active_fg_bg=btn_act_fg_bg}
|
||||
|
||||
TextBox{parent=peri_c_2,x=1,y=1,height=1,text="Select one of the below devices to use."}
|
||||
|
||||
tool_ctl.ppm_devs = ListBox{parent=peri_c_2,x=1,y=3,height=10,width=51,scroll_height=1000,fg_bg=bw_fg_bg,nav_fg_bg=g_lg_fg_bg,nav_active=cpair(colors.black,colors.gray)}
|
||||
tool_ctl.ppm_devs = ListBox{parent=peri_c_2,x=1,y=3,height=10,width=49,scroll_height=1000,fg_bg=bw_fg_bg,nav_fg_bg=g_lg_fg_bg,nav_active=cpair(colors.black,colors.gray)}
|
||||
|
||||
PushButton{parent=peri_c_2,x=1,y=14,min_width=6,text="\x1b Back",callback=function()peri_pane.set_value(1)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=peri_c_2,x=1,y=14,text="\x1b Back",callback=function()peri_pane.set_value(1)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=peri_c_2,x=8,y=14,min_width=10,text="Manual +",callback=function()peri_pane.set_value(3)end,fg_bg=cpair(colors.black,colors.orange),active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=peri_c_2,x=26,y=14,min_width=24,text="I don't see my device!",callback=function()peri_pane.set_value(7)end,fg_bg=cpair(colors.black,colors.yellow),active_fg_bg=btn_act_fg_bg}
|
||||
|
||||
TextBox{parent=peri_c_7,x=1,y=1,height=10,text="Make sure your device is either touching the RTU or connected via wired modems. There should be a wired modem on a side of the RTU then one on the device, connected by a cable. The modem on the device needs to be right clicked to connect it (which will turn its border red), at which point the peripheral name will be shown in the chat."}
|
||||
TextBox{parent=peri_c_7,x=1,y=9,height=4,text="If it still does not show, it may not be compatible. Currently only Boilers, Turbines, Dynamic Tanks, SNAs, SPSs, Induction Matricies, and Environment Detectors are supported."}
|
||||
PushButton{parent=peri_c_7,x=1,y=14,min_width=6,text="\x1b Back",callback=function()peri_pane.set_value(2)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=peri_c_7,x=1,y=14,text="\x1b Back",callback=function()peri_pane.set_value(2)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
|
||||
local new_peri_attrs = { "", "" }
|
||||
local function new_peri(name, type)
|
||||
@@ -694,6 +702,7 @@ local function config_view(display)
|
||||
tool_ctl.p_idx.set_max(2)
|
||||
tool_ctl.p_unit.reposition(44, 4)
|
||||
tool_ctl.p_unit.enable()
|
||||
tool_ctl.p_unit.show()
|
||||
tool_ctl.p_assign_btn.hide(true)
|
||||
tool_ctl.p_assign_end.hide(true)
|
||||
tool_ctl.p_desc.reposition(1, 7)
|
||||
@@ -706,6 +715,7 @@ local function config_view(display)
|
||||
tool_ctl.p_idx.set_max(3)
|
||||
tool_ctl.p_unit.reposition(45, 4)
|
||||
tool_ctl.p_unit.enable()
|
||||
tool_ctl.p_unit.show()
|
||||
tool_ctl.p_assign_btn.hide(true)
|
||||
tool_ctl.p_assign_end.hide(true)
|
||||
tool_ctl.p_desc.reposition(1, 7)
|
||||
@@ -715,6 +725,7 @@ local function config_view(display)
|
||||
tool_ctl.p_prompt.set_value("This SNA is for reactor unit # .")
|
||||
tool_ctl.p_unit.reposition(31, 4)
|
||||
tool_ctl.p_unit.enable()
|
||||
tool_ctl.p_unit.show()
|
||||
tool_ctl.p_assign_btn.hide(true)
|
||||
tool_ctl.p_assign_end.hide(true)
|
||||
tool_ctl.p_desc_ext.set_value("Before adding lots of SNAs: multiply the \"PEAK\" rate on the flow monitor (after connecting at least 1 SNA) by 10 to get the mB/t of waste that they can process. Enough SNAs to provide 2x to 3x of your max burn rate should be a good margin to catch up after night or cloudy weather. Too many devices (such as SNAs) on one RTU can cause lag.")
|
||||
@@ -728,6 +739,8 @@ local function config_view(display)
|
||||
tool_ctl.p_idx.redraw()
|
||||
tool_ctl.p_idx.set_max(4)
|
||||
tool_ctl.p_unit.reposition(18, 6)
|
||||
tool_ctl.p_unit.enable()
|
||||
tool_ctl.p_unit.show()
|
||||
|
||||
if tool_ctl.p_assign_btn.get_value() == 1 then
|
||||
tool_ctl.p_idx.enable()
|
||||
@@ -750,6 +763,8 @@ local function config_view(display)
|
||||
tool_ctl.p_idx.redraw()
|
||||
tool_ctl.p_idx.set_max(99)
|
||||
tool_ctl.p_unit.reposition(18, 6)
|
||||
tool_ctl.p_unit.enable()
|
||||
tool_ctl.p_unit.show()
|
||||
if tool_ctl.p_assign_btn.get_value() == 1 then tool_ctl.p_unit.disable() else tool_ctl.p_unit.enable() end
|
||||
tool_ctl.p_desc.reposition(1, 8)
|
||||
tool_ctl.p_desc.set_value("You can connect more than one environment detector for a particular unit or the facility. In that case, the maximum radiation reading from those assigned to that particular unit or the facility will be used for alarms and display.")
|
||||
@@ -811,16 +826,16 @@ local function config_view(display)
|
||||
else man_p_err.show() end
|
||||
end
|
||||
|
||||
PushButton{parent=peri_c_3,x=1,y=14,min_width=6,text="\x1b Back",callback=function()peri_pane.set_value(2)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=peri_c_3,x=44,y=14,min_width=6,text="Next \x1a",callback=submit_manual_peri,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=peri_c_3,x=1,y=14,text="\x1b Back",callback=function()peri_pane.set_value(2)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=peri_c_3,x=44,y=14,text="Next \x1a",callback=submit_manual_peri,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
|
||||
tool_ctl.p_name_msg = TextBox{parent=peri_c_4,x=1,y=1,height=2,text=""}
|
||||
tool_ctl.p_prompt = TextBox{parent=peri_c_4,x=1,y=4,height=2,text=""}
|
||||
tool_ctl.p_idx = NumberField{parent=peri_c_4,x=14,y=4,width=4,max_digits=2,min=1,max=2,default=1,fg_bg=bw_fg_bg,dis_fg_bg=cpair(colors.lightGray,colors.white)}
|
||||
tool_ctl.p_idx = NumberField{parent=peri_c_4,x=14,y=4,width=4,max_chars=2,min=1,max=2,default=1,fg_bg=bw_fg_bg,dis_fg_bg=cpair(colors.lightGray,colors.white)}
|
||||
tool_ctl.p_assign_btn = RadioButton{parent=peri_c_4,x=1,y=5,default=1,options={"the facility.","a unit. (unit #"},callback=function(v)tool_ctl.p_assign(v)end,radio_colors=cpair(colors.lightGray,colors.black),select_color=colors.purple}
|
||||
tool_ctl.p_assign_end = TextBox{parent=peri_c_4,x=22,y=6,height=6,width=1,text=")"}
|
||||
|
||||
tool_ctl.p_unit = NumberField{parent=peri_c_4,x=44,y=4,width=4,max_digits=2,min=1,max=4,default=1,fg_bg=bw_fg_bg,dis_fg_bg=cpair(colors.lightGray,colors.white)}
|
||||
tool_ctl.p_unit = NumberField{parent=peri_c_4,x=44,y=4,width=4,max_chars=2,min=1,max=4,default=1,fg_bg=bw_fg_bg,dis_fg_bg=cpair(colors.lightGray,colors.white)}
|
||||
tool_ctl.p_unit.disable()
|
||||
|
||||
function tool_ctl.p_assign(opt)
|
||||
@@ -839,7 +854,7 @@ local function config_view(display)
|
||||
tool_ctl.p_desc = TextBox{parent=peri_c_4,x=1,y=7,height=6,text="",fg_bg=g_lg_fg_bg}
|
||||
tool_ctl.p_desc_ext = TextBox{parent=peri_c_4,x=1,y=6,height=7,text="",fg_bg=g_lg_fg_bg}
|
||||
|
||||
tool_ctl.p_err = TextBox{parent=peri_c_4,x=8,y=14,height=1,width=35,text="",fg_bg=cpair(colors.red,colors.lightGray),hidden=true}
|
||||
tool_ctl.p_err = TextBox{parent=peri_c_4,x=8,y=14,height=1,width=32,text="",fg_bg=cpair(colors.red,colors.lightGray),hidden=true}
|
||||
tool_ctl.p_err.hide(true)
|
||||
|
||||
local function back_from_peri_opts()
|
||||
@@ -868,7 +883,7 @@ local function config_view(display)
|
||||
if (peri_type == "dynamicValve" or peri_type == "environmentDetector") and for_facility then
|
||||
-- skip
|
||||
elseif not (util.is_int(u) and u > 0 and u < 5) then
|
||||
tool_ctl.p_err.set_value("Unit ID must be within 1 through 4.")
|
||||
tool_ctl.p_err.set_value("Unit ID must be within 1 to 4.")
|
||||
tool_ctl.p_err.show()
|
||||
return
|
||||
else unit = u end
|
||||
@@ -888,7 +903,7 @@ local function config_view(display)
|
||||
else index = idx end
|
||||
elseif peri_type == "dynamicValve" and for_facility then
|
||||
if not (util.is_int(idx) and idx > 0 and idx < 5) then
|
||||
tool_ctl.p_err.set_value("Index must be within 1 through 4.")
|
||||
tool_ctl.p_err.set_value("Index must be within 1 to 4.")
|
||||
tool_ctl.p_err.show()
|
||||
return
|
||||
else index = idx end
|
||||
@@ -916,24 +931,25 @@ local function config_view(display)
|
||||
|
||||
peri_pane.set_value(1)
|
||||
tool_ctl.gen_peri_summary(tmp_cfg)
|
||||
tool_ctl.update_peri_list()
|
||||
|
||||
tool_ctl.p_idx.set_value(1)
|
||||
end
|
||||
|
||||
PushButton{parent=peri_c_4,x=1,y=14,min_width=6,text="\x1b Back",callback=back_from_peri_opts,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=peri_c_4,x=1,y=14,text="\x1b Back",callback=back_from_peri_opts,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=peri_c_4,x=41,y=14,min_width=9,text="Confirm",callback=save_peri_entry,fg_bg=cpair(colors.black,colors.blue),active_fg_bg=btn_act_fg_bg}
|
||||
|
||||
TextBox{parent=peri_c_5,x=1,y=1,height=1,text="Settings saved!"}
|
||||
PushButton{parent=peri_c_5,x=1,y=14,min_width=6,text="\x1b Back",callback=function()peri_pane.set_value(1)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=peri_c_5,x=1,y=14,text="\x1b Back",callback=function()peri_pane.set_value(1)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=peri_c_5,x=44,y=14,min_width=6,text="Home",callback=function()tool_ctl.go_home()end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
|
||||
TextBox{parent=peri_c_6,x=1,y=1,height=5,text="Failed to save the settings file.\n\nThere may not be enough space for the modification or server file permissions may be denying writes."}
|
||||
PushButton{parent=peri_c_6,x=1,y=14,min_width=6,text="\x1b Back",callback=function()peri_pane.set_value(1)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=peri_c_6,x=1,y=14,text="\x1b Back",callback=function()peri_pane.set_value(1)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=peri_c_6,x=44,y=14,min_width=6,text="Home",callback=function()tool_ctl.go_home()end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
|
||||
--#endregion
|
||||
|
||||
--#region REDSTONE
|
||||
--#region Redstone
|
||||
|
||||
local rs_c_1 = Div{parent=rs_cfg,x=2,y=4,width=49}
|
||||
local rs_c_2 = Div{parent=rs_cfg,x=2,y=4,width=49}
|
||||
@@ -947,7 +963,7 @@ local function config_view(display)
|
||||
TextBox{parent=rs_cfg,x=1,y=2,height=1,text=" Redstone Connections",fg_bg=cpair(colors.black,colors.red)}
|
||||
|
||||
TextBox{parent=rs_c_1,x=1,y=1,height=1,text=" port side/color unit/facility",fg_bg=g_lg_fg_bg}
|
||||
local rs_list = ListBox{parent=rs_c_1,x=1,y=2,height=11,width=51,scroll_height=200,fg_bg=bw_fg_bg,nav_fg_bg=g_lg_fg_bg,nav_active=cpair(colors.black,colors.gray)}
|
||||
local rs_list = ListBox{parent=rs_c_1,x=1,y=2,height=11,width=49,scroll_height=200,fg_bg=bw_fg_bg,nav_fg_bg=g_lg_fg_bg,nav_active=cpair(colors.black,colors.gray)}
|
||||
|
||||
local function rs_revert()
|
||||
tmp_cfg.Redstone = deep_copy_rs(ini_cfg.Redstone)
|
||||
@@ -957,30 +973,29 @@ local function config_view(display)
|
||||
local function rs_apply()
|
||||
settings.set("Redstone", tmp_cfg.Redstone)
|
||||
|
||||
if settings.save("rtu.settings") then
|
||||
load_settings(ini_cfg)
|
||||
if settings.save("/rtu.settings") then
|
||||
load_settings(settings_cfg, true)
|
||||
load_settings(ini_cfg)
|
||||
rs_pane.set_value(4)
|
||||
else
|
||||
rs_pane.set_value(5)
|
||||
end
|
||||
end
|
||||
|
||||
PushButton{parent=rs_c_1,x=1,y=14,min_width=6,text="\x1b Back",callback=function()main_pane.set_value(1)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=rs_c_1,x=1,y=14,text="\x1b Back",callback=function()main_pane.set_value(1)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=rs_c_1,x=8,y=14,min_width=16,text="Revert Changes",callback=rs_revert,fg_bg=cpair(colors.black,colors.yellow),active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=rs_c_1,x=35,y=14,min_width=7,text="New +",callback=function()rs_pane.set_value(2)end,fg_bg=cpair(colors.black,colors.blue),active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=rs_c_1,x=43,y=14,min_width=7,text="Apply",callback=rs_apply,fg_bg=cpair(colors.black,colors.green),active_fg_bg=btn_act_fg_bg}
|
||||
|
||||
TextBox{parent=rs_c_6,x=1,y=1,height=5,text="You already configured this input. There can only be one entry for each input.\n\nPlease select a different port."}
|
||||
PushButton{parent=rs_c_6,x=1,y=14,min_width=6,text="\x1b Back",callback=function()rs_pane.set_value(2)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=rs_c_6,x=1,y=14,text="\x1b Back",callback=function()rs_pane.set_value(2)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
|
||||
TextBox{parent=rs_c_2,x=1,y=1,height=1,text="Select one of the below ports to use."}
|
||||
|
||||
local rs_ports = ListBox{parent=rs_c_2,x=1,y=3,height=10,width=51,scroll_height=200,fg_bg=bw_fg_bg,nav_fg_bg=g_lg_fg_bg,nav_active=cpair(colors.black,colors.gray)}
|
||||
local rs_ports = ListBox{parent=rs_c_2,x=1,y=3,height=10,width=49,scroll_height=200,fg_bg=bw_fg_bg,nav_fg_bg=g_lg_fg_bg,nav_active=cpair(colors.black,colors.gray)}
|
||||
|
||||
local new_rs_port = IO.F_SCRAM
|
||||
local function new_rs(port)
|
||||
if (rsio.get_io_mode(port) == rsio.IO_DIR.IN) then
|
||||
if (rsio.get_io_dir(port) == rsio.IO_DIR.IN) then
|
||||
for i = 1, #tmp_cfg.Redstone do
|
||||
if tmp_cfg.Redstone[i].port == port then
|
||||
rs_pane.set_value(6)
|
||||
@@ -996,9 +1011,11 @@ local function config_view(display)
|
||||
if port == -1 then
|
||||
tool_ctl.rs_cfg_color.hide(true)
|
||||
tool_ctl.rs_cfg_shortcut.show()
|
||||
tool_ctl.rs_cfg_side_l.set_value("Output Side")
|
||||
text = "You selected the ALL_WASTE shortcut."
|
||||
else
|
||||
tool_ctl.rs_cfg_shortcut.hide(true)
|
||||
tool_ctl.rs_cfg_side_l.set_value(util.trinary(rsio.get_io_dir(port) == rsio.IO_DIR.IN, "Input Side", "Output Side"))
|
||||
tool_ctl.rs_cfg_color.show()
|
||||
text = "You selected " .. rsio.to_string(port) .. " (for "
|
||||
if PORT_DSGN[port] == 1 then
|
||||
@@ -1013,7 +1030,7 @@ local function config_view(display)
|
||||
end
|
||||
|
||||
tool_ctl.rs_cfg_selection.set_value(text)
|
||||
new_rs_port = port
|
||||
tool_ctl.rs_cfg_port = port
|
||||
rs_pane.set_value(3)
|
||||
end
|
||||
|
||||
@@ -1024,22 +1041,22 @@ local function config_view(display)
|
||||
TextBox{parent=all_w_macro,x=22,y=1,height=1,text="Create all 4 waste entries",fg_bg=cpair(colors.gray,colors.white)}
|
||||
for i = 1, rsio.NUM_PORTS do
|
||||
local name = rsio.to_string(i)
|
||||
local io_dir = util.trinary(rsio.get_io_mode(i) == rsio.IO_DIR.IN, "[in]", "[out]")
|
||||
local btn_color = util.trinary(rsio.get_io_mode(i) == rsio.IO_DIR.IN, colors.yellow, colors.lightBlue)
|
||||
local io_dir = util.trinary(rsio.get_io_dir(i) == rsio.IO_DIR.IN, "[in]", "[out]")
|
||||
local btn_color = util.trinary(rsio.get_io_dir(i) == rsio.IO_DIR.IN, colors.yellow, colors.lightBlue)
|
||||
local entry = Div{parent=rs_ports,height=1}
|
||||
PushButton{parent=entry,x=1,y=1,min_width=14,alignment=LEFT,height=1,text=">"..name,callback=function()new_rs(i)end,fg_bg=cpair(colors.black,btn_color),active_fg_bg=cpair(colors.white,colors.black)}
|
||||
TextBox{parent=entry,x=16,y=1,width=5,height=1,text=io_dir,fg_bg=cpair(colors.lightGray,colors.white)}
|
||||
TextBox{parent=entry,x=22,y=1,height=1,text=PORT_DESC[i],fg_bg=cpair(colors.gray,colors.white)}
|
||||
end
|
||||
|
||||
PushButton{parent=rs_c_2,x=1,y=14,min_width=6,text="\x1b Back",callback=function()rs_pane.set_value(1)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=rs_c_2,x=1,y=14,text="\x1b Back",callback=function()rs_pane.set_value(1)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
|
||||
tool_ctl.rs_cfg_selection = TextBox{parent=rs_c_3,x=1,y=1,height=1,text=""}
|
||||
|
||||
tool_ctl.rs_cfg_unit_l = TextBox{parent=rs_c_3,x=27,y=3,width=7,height=1,text="Unit ID"}
|
||||
tool_ctl.rs_cfg_unit = NumberField{parent=rs_c_3,x=27,y=4,width=10,max_digits=2,min=1,max=4,fg_bg=bw_fg_bg}
|
||||
tool_ctl.rs_cfg_unit = NumberField{parent=rs_c_3,x=27,y=4,width=10,max_chars=2,min=1,max=4,fg_bg=bw_fg_bg}
|
||||
|
||||
TextBox{parent=rs_c_3,x=1,y=3,width=11,height=1,text="Output Side"}
|
||||
tool_ctl.rs_cfg_side_l = TextBox{parent=rs_c_3,x=1,y=3,width=11,height=1,text="Output Side"}
|
||||
local side = Radio2D{parent=rs_c_3,x=1,y=4,rows=2,columns=3,default=1,options=side_options,radio_colors=cpair(colors.lightGray,colors.black),select_color=colors.red}
|
||||
|
||||
local function set_bundled(bundled)
|
||||
@@ -1053,7 +1070,7 @@ local function config_view(display)
|
||||
tool_ctl.rs_cfg_color = Radio2D{parent=rs_c_3,x=1,y=9,rows=4,columns=4,default=1,options=color_options,radio_colors=cpair(colors.lightGray,colors.black),color_map=color_options_map,disable_color=colors.gray,disable_fg_bg=g_lg_fg_bg}
|
||||
tool_ctl.rs_cfg_color.disable()
|
||||
|
||||
local rs_err = TextBox{parent=rs_c_3,x=8,y=14,height=1,width=35,text="Unit ID must be within 1 through 4.",fg_bg=cpair(colors.red,colors.lightGray),hidden=true}
|
||||
local rs_err = TextBox{parent=rs_c_3,x=8,y=14,height=1,width=30,text="Unit ID must be within 1 to 4.",fg_bg=cpair(colors.red,colors.lightGray),hidden=true}
|
||||
rs_err.hide(true)
|
||||
|
||||
local function back_from_rs_opts()
|
||||
@@ -1062,16 +1079,17 @@ local function config_view(display)
|
||||
end
|
||||
|
||||
local function save_rs_entry()
|
||||
local port = tool_ctl.rs_cfg_port
|
||||
local u = tonumber(tool_ctl.rs_cfg_unit.get_value())
|
||||
|
||||
if PORT_DSGN[new_rs_port] == 0 or (util.is_int(u) and u > 0 and u < 5) then
|
||||
if PORT_DSGN[port] == 0 or (util.is_int(u) and u > 0 and u < 5) then
|
||||
rs_err.hide(true)
|
||||
|
||||
if new_rs_port >= 0 then
|
||||
if port >= 0 then
|
||||
---@type rtu_rs_definition
|
||||
local def = {
|
||||
unit = util.trinary(PORT_DSGN[new_rs_port] == 1, u, nil),
|
||||
port = new_rs_port,
|
||||
unit = util.trinary(PORT_DSGN[port] == 1, u, nil),
|
||||
port = port,
|
||||
side = side_options_map[side.get_value()],
|
||||
color = util.trinary(bundled.get_value(), color_options_map[tool_ctl.rs_cfg_color.get_value()], nil)
|
||||
}
|
||||
@@ -1082,7 +1100,7 @@ local function config_view(display)
|
||||
def.port = tmp_cfg.Redstone[tool_ctl.rs_cfg_editing].port
|
||||
tmp_cfg.Redstone[tool_ctl.rs_cfg_editing] = def
|
||||
end
|
||||
elseif new_rs_port == -1 then
|
||||
elseif port == -1 then
|
||||
local default_sides = { "left", "back", "right", "front" }
|
||||
local default_colors = { colors.red, colors.orange, colors.yellow, colors.lime }
|
||||
for i = 0, 3 do
|
||||
@@ -1105,15 +1123,15 @@ local function config_view(display)
|
||||
else rs_err.show() end
|
||||
end
|
||||
|
||||
PushButton{parent=rs_c_3,x=1,y=14,min_width=6,text="\x1b Back",callback=back_from_rs_opts,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=rs_c_3,x=1,y=14,text="\x1b Back",callback=back_from_rs_opts,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=rs_c_3,x=41,y=14,min_width=9,text="Confirm",callback=save_rs_entry,fg_bg=cpair(colors.black,colors.blue),active_fg_bg=btn_act_fg_bg}
|
||||
|
||||
TextBox{parent=rs_c_4,x=1,y=1,height=1,text="Settings saved!"}
|
||||
PushButton{parent=rs_c_4,x=1,y=14,min_width=6,text="\x1b Back",callback=function()rs_pane.set_value(1)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=rs_c_4,x=1,y=14,text="\x1b Back",callback=function()rs_pane.set_value(1)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=rs_c_4,x=44,y=14,min_width=6,text="Home",callback=function()tool_ctl.go_home()end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
|
||||
TextBox{parent=rs_c_5,x=1,y=1,height=5,text="Failed to save the settings file.\n\nThere may not be enough space for the modification or server file permissions may be denying writes."}
|
||||
PushButton{parent=rs_c_5,x=1,y=14,min_width=6,text="\x1b Back",callback=function()rs_pane.set_value(1)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=rs_c_5,x=1,y=14,text="\x1b Back",callback=function()rs_pane.set_value(1)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=rs_c_5,x=44,y=14,min_width=6,text="Home",callback=function()tool_ctl.go_home()end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
|
||||
--#endregion
|
||||
@@ -1126,7 +1144,7 @@ local function config_view(display)
|
||||
|
||||
tool_ctl.importing_any_dc = false
|
||||
|
||||
tmp_cfg.SpeakerVolume = config.SOUNDER_VOLUME
|
||||
tmp_cfg.SpeakerVolume = config.SOUNDER_VOLUME or 1
|
||||
tmp_cfg.SVR_Channel = config.SVR_CHANNEL
|
||||
tmp_cfg.RTU_Channel = config.RTU_CHANNEL
|
||||
tmp_cfg.ConnTimeout = config.COMMS_TIMEOUT
|
||||
@@ -1222,7 +1240,7 @@ local function config_view(display)
|
||||
table.insert(tmp_cfg.Redstone, def)
|
||||
|
||||
local name = rsio.to_string(def.port)
|
||||
local io_dir = util.trinary(rsio.get_io_mode(def.port) == rsio.IO_DIR.IN, "\x1a", "\x1b")
|
||||
local io_dir = util.trinary(rsio.get_io_dir(def.port) == rsio.IO_DIR.IN, "\x1a", "\x1b")
|
||||
local conn = def.side
|
||||
local unit = "facility"
|
||||
|
||||
@@ -1331,6 +1349,7 @@ local function config_view(display)
|
||||
local function delete_peri_entry(idx)
|
||||
table.remove(tmp_cfg.Peripherals, idx)
|
||||
tool_ctl.gen_peri_summary(tmp_cfg)
|
||||
tool_ctl.update_peri_list()
|
||||
end
|
||||
|
||||
-- generate the peripherals summary list
|
||||
@@ -1373,6 +1392,10 @@ local function config_view(display)
|
||||
local function edit_rs_entry(idx)
|
||||
local def = tmp_cfg.Redstone[idx] ---@type rtu_rs_definition
|
||||
|
||||
tool_ctl.rs_cfg_shortcut.hide(true)
|
||||
tool_ctl.rs_cfg_color.show()
|
||||
|
||||
tool_ctl.rs_cfg_port = def.port
|
||||
tool_ctl.rs_cfg_editing = idx
|
||||
|
||||
local text = "Editing " .. rsio.to_string(def.port) .. " (for "
|
||||
@@ -1396,6 +1419,7 @@ local function config_view(display)
|
||||
end
|
||||
|
||||
tool_ctl.rs_cfg_selection.set_value(text)
|
||||
tool_ctl.rs_cfg_side_l.set_value(util.trinary(rsio.get_io_dir(def.port) == rsio.IO_DIR.IN, "Input Side", "Output Side"))
|
||||
side.set_value(side_to_idx(def.side))
|
||||
bundled.set_value(def.color ~= nil)
|
||||
tool_ctl.rs_cfg_color.set_value(value)
|
||||
@@ -1442,12 +1466,12 @@ local function reset_term()
|
||||
end
|
||||
|
||||
-- run the RTU gateway configurator
|
||||
---@param ask_config? boolean indicate if this is being called by the RTU startup app due to an invalid configuration
|
||||
---@param ask_config? boolean indicate if this is being called by the startup app due to an invalid configuration
|
||||
function configurator.configure(ask_config)
|
||||
tool_ctl.ask_config = ask_config == true
|
||||
tool_ctl.has_config = load_settings(ini_cfg)
|
||||
load_settings(settings_cfg, true)
|
||||
|
||||
load_settings(settings_cfg, true)
|
||||
tool_ctl.has_config = load_settings(ini_cfg)
|
||||
tmp_cfg.Peripherals = deep_copy_peri(ini_cfg.Peripherals)
|
||||
tmp_cfg.Redstone = deep_copy_rs(ini_cfg.Redstone)
|
||||
|
||||
|
||||
@@ -110,7 +110,7 @@ local function init(panel, units)
|
||||
|
||||
-- unit name identifier (type + index)
|
||||
local function get_name(t) return util.c(UNIT_TYPE_LABELS[t + 1], " ", util.trinary(util.is_int(unit.index), unit.index, "")) end
|
||||
local name_box = TextBox{parent=unit_hw_statuses,y=i,x=3,text=get_name(unit.type),height=1}
|
||||
local name_box = TextBox{parent=unit_hw_statuses,y=i,x=3,text=get_name(unit.type),width=15,height=1}
|
||||
|
||||
name_box.register(databus.ps, "unit_type_" .. i, function (t) name_box.set_value(get_name(t)) end)
|
||||
|
||||
|
||||
@@ -41,9 +41,11 @@ function rtu.load_config()
|
||||
local cfv = util.new_validator()
|
||||
|
||||
cfv.assert_type_num(config.SpeakerVolume)
|
||||
cfv.assert_range(config.SpeakerVolume, 0, 3)
|
||||
|
||||
cfv.assert_channel(config.SVR_Channel)
|
||||
cfv.assert_channel(config.RTU_Channel)
|
||||
cfv.assert_type_int(config.ConnTimeout)
|
||||
cfv.assert_type_num(config.ConnTimeout)
|
||||
cfv.assert_min(config.ConnTimeout, 2)
|
||||
cfv.assert_type_num(config.TrustedRange)
|
||||
cfv.assert_min(config.TrustedRange, 0)
|
||||
@@ -55,9 +57,13 @@ function rtu.load_config()
|
||||
end
|
||||
|
||||
cfv.assert_type_int(config.LogMode)
|
||||
cfv.assert_range(config.LogMode, 0, 1)
|
||||
cfv.assert_type_str(config.LogPath)
|
||||
cfv.assert_type_bool(config.LogDebug)
|
||||
|
||||
cfv.assert_type_table(config.Peripherals)
|
||||
cfv.assert_type_table(config.Redstone)
|
||||
|
||||
return cfv.valid()
|
||||
end
|
||||
|
||||
|
||||
@@ -31,7 +31,7 @@ local sna_rtu = require("rtu.dev.sna_rtu")
|
||||
local sps_rtu = require("rtu.dev.sps_rtu")
|
||||
local turbinev_rtu = require("rtu.dev.turbinev_rtu")
|
||||
|
||||
local RTU_VERSION = "v1.7.2"
|
||||
local RTU_VERSION = "v1.7.14"
|
||||
|
||||
local RTU_UNIT_TYPE = types.RTU_UNIT_TYPE
|
||||
local RTU_UNIT_HW_STATE = databus.RTU_UNIT_HW_STATE
|
||||
@@ -47,9 +47,13 @@ if not rtu.load_config() then
|
||||
-- try to reconfigure (user action)
|
||||
local success, error = configure.configure(true)
|
||||
if success then
|
||||
assert(rtu.load_config(), "failed to load valid RTU configuration")
|
||||
if not rtu.load_config() then
|
||||
println("failed to load a valid configuration, please reconfigure")
|
||||
return
|
||||
end
|
||||
else
|
||||
assert(success, "RTU configuration error: " .. error)
|
||||
println("configuration error: " .. error)
|
||||
return
|
||||
end
|
||||
end
|
||||
|
||||
|
||||
@@ -17,7 +17,7 @@ local max_distance = nil
|
||||
local comms = {}
|
||||
|
||||
-- protocol/data version (protocol/data independent changes tracked by util.lua version)
|
||||
comms.version = "2.4.2"
|
||||
comms.version = "2.4.5"
|
||||
|
||||
---@enum PROTOCOL
|
||||
local PROTOCOL = {
|
||||
|
||||
@@ -7,7 +7,7 @@ local log = require("scada-common.log")
|
||||
local util = require("scada-common.util")
|
||||
|
||||
local md5 = require("lockbox.digest.md5")
|
||||
local sha256 = require("lockbox.digest.sha2_256")
|
||||
local sha1 = require("lockbox.digest.sha1")
|
||||
local pbkdf2 = require("lockbox.kdf.pbkdf2")
|
||||
local hmac = require("lockbox.mac.hmac")
|
||||
local stream = require("lockbox.util.stream")
|
||||
@@ -31,12 +31,12 @@ function network.init_mac(passkey)
|
||||
local key_deriv = pbkdf2()
|
||||
|
||||
-- setup PBKDF2
|
||||
key_deriv.setPassword(passkey)
|
||||
key_deriv.setPRF(hmac().setBlockSize(64).setDigest(sha1))
|
||||
key_deriv.setBlockLen(20)
|
||||
key_deriv.setDKeyLen(20)
|
||||
key_deriv.setIterations(256)
|
||||
key_deriv.setSalt("pepper")
|
||||
key_deriv.setIterations(32)
|
||||
key_deriv.setBlockLen(8)
|
||||
key_deriv.setDKeyLen(16)
|
||||
key_deriv.setPRF(hmac().setBlockSize(64).setDigest(sha256))
|
||||
key_deriv.setPassword(passkey)
|
||||
key_deriv.finish()
|
||||
|
||||
c_eng.key = array.fromHex(key_deriv.asHex())
|
||||
@@ -53,6 +53,11 @@ function network.init_mac(passkey)
|
||||
return init_time
|
||||
end
|
||||
|
||||
-- de-initialize message authentication system
|
||||
function network.deinit_mac()
|
||||
c_eng.key, c_eng.hmac = nil, nil
|
||||
end
|
||||
|
||||
-- generate HMAC of message
|
||||
---@nodiscard
|
||||
---@param message string initial value concatenated with ciphertext
|
||||
|
||||
@@ -9,7 +9,7 @@ local util = require("scada-common.util")
|
||||
local ppm = {}
|
||||
|
||||
local ACCESS_FAULT = nil ---@type nil
|
||||
local UNDEFINED_FIELD = "undefined field"
|
||||
local UNDEFINED_FIELD = "__PPM_UNDEF_FIELD__"
|
||||
local VIRTUAL_DEVICE_TYPE = "ppm_vdev"
|
||||
|
||||
ppm.ACCESS_FAULT = ACCESS_FAULT
|
||||
@@ -155,7 +155,7 @@ local function peri_init(iface)
|
||||
|
||||
self.fault_counts[key] = self.fault_counts[key] + 1
|
||||
|
||||
return (function () return ACCESS_FAULT end)
|
||||
return (function () return UNDEFINED_FIELD end)
|
||||
end
|
||||
}
|
||||
|
||||
@@ -300,6 +300,17 @@ function ppm.handle_unmount(iface)
|
||||
return pm_type, pm_dev
|
||||
end
|
||||
|
||||
-- log all mounts, to be used if `ppm.mount_all` is called before logging is ready
|
||||
function ppm.log_mounts()
|
||||
for iface, mount in pairs(ppm_sys.mounts) do
|
||||
log.info(util.c("PPM: had found a ", mount.type, " (", iface, ")"))
|
||||
end
|
||||
|
||||
if util.table_len(ppm_sys.mounts) == 0 then
|
||||
log.warning("PPM: no devices had been found")
|
||||
end
|
||||
end
|
||||
|
||||
-- GENERAL ACCESSORS --
|
||||
|
||||
-- list all available peripherals
|
||||
@@ -421,4 +432,15 @@ function ppm.get_monitor_list()
|
||||
return list
|
||||
end
|
||||
|
||||
-- HELPER FUNCTIONS
|
||||
|
||||
-- get the block size of a monitor given its width and height <b>at a text scale of 0.5</b>
|
||||
---@nodiscard
|
||||
---@param width integer character width
|
||||
---@param height integer character height
|
||||
---@return integer block_width, integer block_height
|
||||
function ppm.monitor_block_size(width, height)
|
||||
return math.floor((width - 15) / 21) + 1, math.floor((height - 10) / 14) + 1
|
||||
end
|
||||
|
||||
return ppm
|
||||
|
||||
@@ -127,7 +127,37 @@ local PORT_NAMES = {
|
||||
"U_EMER_COOL"
|
||||
}
|
||||
|
||||
local MODES = {
|
||||
IO_MODE.DIGITAL_IN, -- F_SCRAM
|
||||
IO_MODE.DIGITAL_IN, -- F_ACK
|
||||
IO_MODE.DIGITAL_IN, -- R_SCRAM
|
||||
IO_MODE.DIGITAL_IN, -- R_RESET
|
||||
IO_MODE.DIGITAL_IN, -- R_ENABLE
|
||||
IO_MODE.DIGITAL_IN, -- U_ACK
|
||||
IO_MODE.DIGITAL_OUT, -- F_ALARM
|
||||
IO_MODE.DIGITAL_OUT, -- F_ALARM_ANY
|
||||
IO_MODE.DIGITAL_OUT, -- WASTE_PU
|
||||
IO_MODE.DIGITAL_OUT, -- WASTE_PO
|
||||
IO_MODE.DIGITAL_OUT, -- WASTE_POPL
|
||||
IO_MODE.DIGITAL_OUT, -- WASTE_AM
|
||||
IO_MODE.DIGITAL_OUT, -- R_ACTIVE
|
||||
IO_MODE.DIGITAL_OUT, -- R_AUTO_CTRL
|
||||
IO_MODE.DIGITAL_OUT, -- R_SCRAMMED
|
||||
IO_MODE.DIGITAL_OUT, -- R_AUTO_SCRAM
|
||||
IO_MODE.DIGITAL_OUT, -- R_HIGH_DMG
|
||||
IO_MODE.DIGITAL_OUT, -- R_HIGH_TEMP
|
||||
IO_MODE.DIGITAL_OUT, -- R_LOW_COOLANT
|
||||
IO_MODE.DIGITAL_OUT, -- R_EXCESS_HC
|
||||
IO_MODE.DIGITAL_OUT, -- R_EXCESS_WS
|
||||
IO_MODE.DIGITAL_OUT, -- R_INSUFF_FUEL
|
||||
IO_MODE.DIGITAL_OUT, -- R_PLC_FAULT
|
||||
IO_MODE.DIGITAL_OUT, -- R_PLC_TIMEOUT
|
||||
IO_MODE.DIGITAL_OUT, -- U_ALARM
|
||||
IO_MODE.DIGITAL_OUT -- U_EMER_COOL
|
||||
}
|
||||
|
||||
assert(rsio.NUM_PORTS == #PORT_NAMES, "port names length incorrect")
|
||||
assert(rsio.NUM_PORTS == #MODES, "modes length incorrect")
|
||||
|
||||
-- port to string
|
||||
---@nodiscard
|
||||
@@ -209,45 +239,24 @@ local RS_DIO_MAP = {
|
||||
{ _in = _I_ACTIVE_LOW, _out = _O_ACTIVE_LOW, mode = IO_DIR.OUT }
|
||||
}
|
||||
|
||||
assert(rsio.NUM_PORTS == #RS_DIO_MAP, "RS_DIO_MAP length incorrect")
|
||||
|
||||
-- get the I/O direction of a port
|
||||
---@nodiscard
|
||||
---@param port IO_PORT
|
||||
---@return IO_DIR
|
||||
function rsio.get_io_dir(port)
|
||||
if rsio.is_valid_port(port) then return RS_DIO_MAP[port].mode
|
||||
else return IO_DIR.IN end
|
||||
end
|
||||
|
||||
-- get the mode of a port
|
||||
---@nodiscard
|
||||
---@param port IO_PORT
|
||||
---@return IO_MODE
|
||||
function rsio.get_io_mode(port)
|
||||
local modes = {
|
||||
IO_MODE.DIGITAL_IN, -- F_SCRAM
|
||||
IO_MODE.DIGITAL_IN, -- F_ACK
|
||||
IO_MODE.DIGITAL_IN, -- R_SCRAM
|
||||
IO_MODE.DIGITAL_IN, -- R_RESET
|
||||
IO_MODE.DIGITAL_IN, -- R_ENABLE
|
||||
IO_MODE.DIGITAL_IN, -- U_ACK
|
||||
IO_MODE.DIGITAL_OUT, -- F_ALARM
|
||||
IO_MODE.DIGITAL_OUT, -- F_ALARM_ANY
|
||||
IO_MODE.DIGITAL_OUT, -- WASTE_PU
|
||||
IO_MODE.DIGITAL_OUT, -- WASTE_PO
|
||||
IO_MODE.DIGITAL_OUT, -- WASTE_POPL
|
||||
IO_MODE.DIGITAL_OUT, -- WASTE_AM
|
||||
IO_MODE.DIGITAL_OUT, -- R_ACTIVE
|
||||
IO_MODE.DIGITAL_OUT, -- R_AUTO_CTRL
|
||||
IO_MODE.DIGITAL_OUT, -- R_SCRAMMED
|
||||
IO_MODE.DIGITAL_OUT, -- R_AUTO_SCRAM
|
||||
IO_MODE.DIGITAL_OUT, -- R_HIGH_DMG
|
||||
IO_MODE.DIGITAL_OUT, -- R_HIGH_TEMP
|
||||
IO_MODE.DIGITAL_OUT, -- R_LOW_COOLANT
|
||||
IO_MODE.DIGITAL_OUT, -- R_EXCESS_HC
|
||||
IO_MODE.DIGITAL_OUT, -- R_EXCESS_WS
|
||||
IO_MODE.DIGITAL_OUT, -- R_INSUFF_FUEL
|
||||
IO_MODE.DIGITAL_OUT, -- R_PLC_FAULT
|
||||
IO_MODE.DIGITAL_OUT, -- R_PLC_TIMEOUT
|
||||
IO_MODE.DIGITAL_OUT, -- U_ALARM
|
||||
IO_MODE.DIGITAL_OUT -- U_EMER_COOL
|
||||
}
|
||||
|
||||
if util.is_int(port) and port > 0 and port <= #modes then
|
||||
return modes[port]
|
||||
else
|
||||
return IO_MODE.ANALOG_IN
|
||||
end
|
||||
if rsio.is_valid_port(port) then return MODES[port]
|
||||
else return IO_MODE.ANALOG_IN end
|
||||
end
|
||||
|
||||
--#endregion
|
||||
@@ -261,7 +270,7 @@ local RS_SIDES = rs.getSides()
|
||||
---@param port IO_PORT
|
||||
---@return boolean valid
|
||||
function rsio.is_valid_port(port)
|
||||
return util.is_int(port) and (port > 0) and (port <= IO_PORT.U_EMER_COOL)
|
||||
return util.is_int(port) and port > 0 and port <= rsio.NUM_PORTS
|
||||
end
|
||||
|
||||
-- check if a side is valid
|
||||
|
||||
@@ -16,13 +16,13 @@ local type = type
|
||||
|
||||
local t_concat = table.concat
|
||||
local t_insert = table.insert
|
||||
local t_unpack = table.unpack
|
||||
local t_pack = table.pack
|
||||
|
||||
---@class util
|
||||
local util = {}
|
||||
|
||||
-- scada-common version
|
||||
util.version = "1.1.9"
|
||||
util.version = "1.1.18"
|
||||
|
||||
util.TICK_TIME_S = 0.05
|
||||
util.TICK_TIME_MS = 50
|
||||
@@ -78,6 +78,17 @@ function util.strval(val)
|
||||
else return tostring(val) end
|
||||
end
|
||||
|
||||
-- tokenize a string by a separator<br>
|
||||
-- does not behave exactly like C's strtok
|
||||
---@param str string string to tokenize
|
||||
---@param sep string separator to tokenize by
|
||||
---@return table token_list
|
||||
function util.strtok(str, sep)
|
||||
local list = {}
|
||||
for part in string.gmatch(str, "([^" .. sep .. "]+)") do t_insert(list, part) end
|
||||
return list
|
||||
end
|
||||
|
||||
-- repeat a space n times
|
||||
---@nodiscard
|
||||
---@param n integer
|
||||
@@ -104,17 +115,13 @@ end
|
||||
---@return table lines
|
||||
function util.strwrap(str, limit) return cc_strings.wrap(str, limit) end
|
||||
|
||||
-- luacheck: no unused args
|
||||
|
||||
-- concatenation with built-in to string
|
||||
---@nodiscard
|
||||
---@vararg any
|
||||
---@return string
|
||||
---@diagnostic disable-next-line: unused-vararg
|
||||
function util.concat(...)
|
||||
local strings = {}
|
||||
---@diagnostic disable-next-line: undefined-field
|
||||
for i = 1, arg.n do strings[i] = util.strval(arg[i]) end
|
||||
local args, strings = t_pack(...), {}
|
||||
for i = 1, args.n do strings[i] = util.strval(args[i]) end
|
||||
return t_concat(strings)
|
||||
end
|
||||
|
||||
@@ -125,10 +132,7 @@ util.c = util.concat
|
||||
---@nodiscard
|
||||
---@param format string
|
||||
---@vararg any
|
||||
---@diagnostic disable-next-line: unused-vararg
|
||||
function util.sprintf(format, ...) return string.format(format, t_unpack(arg)) end
|
||||
|
||||
-- luacheck: unused args
|
||||
function util.sprintf(format, ...) return string.format(format, ...) end
|
||||
|
||||
-- format a number string with commas as the thousands separator<br>
|
||||
-- subtracts from spaces at the start if present for each comma used
|
||||
@@ -280,11 +284,13 @@ function util.cancel_timer(timer) os.cancelTimer(timer) end
|
||||
|
||||
--#region PARALLELIZATION
|
||||
|
||||
-- protected sleep call so we still are in charge of catching termination
|
||||
---@param t integer seconds
|
||||
-- protected sleep call so we still are in charge of catching termination<br>
|
||||
-- returns the result of pcall
|
||||
---@param t number seconds
|
||||
---@return boolean success, any result, any ...
|
||||
--- EVENT_CONSUMER: this function consumes events
|
||||
---@diagnostic disable-next-line: undefined-field
|
||||
function util.psleep(t) pcall(os.sleep, t) end
|
||||
function util.psleep(t) return pcall(os.sleep, t) end
|
||||
|
||||
-- no-op to provide a brief pause (1 tick) to yield<br>
|
||||
--- EVENT_CONSUMER: this function consumes events
|
||||
@@ -344,6 +350,16 @@ function util.table_contains(t, element)
|
||||
return false
|
||||
end
|
||||
|
||||
-- count the length of a table, even if the values are not sequential or contain named keys
|
||||
---@nodiscard
|
||||
---@param t table
|
||||
---@return integer length
|
||||
function util.table_len(t)
|
||||
local n = 0
|
||||
for _, _ in pairs(t) do n = n + 1 end
|
||||
return n
|
||||
end
|
||||
|
||||
--#endregion
|
||||
|
||||
--#region MEKANISM POWER
|
||||
|
||||
@@ -2,7 +2,7 @@ local util = require("scada-common.util")
|
||||
|
||||
local println = util.println
|
||||
|
||||
local BOOTLOADER_VERSION = "0.4"
|
||||
local BOOTLOADER_VERSION = "1.0"
|
||||
|
||||
println("SCADA BOOTLOADER V" .. BOOTLOADER_VERSION)
|
||||
println("BOOT> SCANNING FOR APPLICATIONS...")
|
||||
|
||||
@@ -1,56 +0,0 @@
|
||||
local config = {}
|
||||
|
||||
-- supervisor comms channel
|
||||
config.SVR_CHANNEL = 16240
|
||||
-- PLC comms channel
|
||||
config.PLC_CHANNEL = 16241
|
||||
-- RTU/MODBUS comms channel
|
||||
config.RTU_CHANNEL = 16242
|
||||
-- coordinator comms channel
|
||||
config.CRD_CHANNEL = 16243
|
||||
-- pocket comms channel
|
||||
config.PKT_CHANNEL = 16244
|
||||
-- max trusted modem message distance
|
||||
-- (0 to disable check)
|
||||
config.TRUSTED_RANGE = 0
|
||||
-- time in seconds (>= 2) before assuming a remote
|
||||
-- device is no longer active
|
||||
config.PLC_TIMEOUT = 5
|
||||
config.RTU_TIMEOUT = 5
|
||||
config.CRD_TIMEOUT = 5
|
||||
config.PKT_TIMEOUT = 5
|
||||
-- facility authentication key
|
||||
-- (do NOT use one of your passwords)
|
||||
-- this enables verifying that messages are authentic
|
||||
-- all devices on this network must use this key
|
||||
-- config.AUTH_KEY = "SCADAfacility123"
|
||||
|
||||
-- expected number of reactors
|
||||
config.NUM_REACTORS = 4
|
||||
-- expected number of devices for each unit
|
||||
config.REACTOR_COOLING = {
|
||||
-- reactor unit 1
|
||||
{ BOILERS = 1, TURBINES = 1, TANK = false },
|
||||
-- reactor unit 2
|
||||
{ BOILERS = 1, TURBINES = 1, TANK = false },
|
||||
-- reactor unit 3
|
||||
{ BOILERS = 1, TURBINES = 1, TANK = false },
|
||||
-- reactor unit 4
|
||||
{ BOILERS = 1, TURBINES = 1, TANK = false }
|
||||
}
|
||||
-- advanced facility dynamic tank configuration
|
||||
-- (see wiki for details)
|
||||
-- by default, dynamic tanks are for each unit
|
||||
config.FAC_TANK_MODE = 0
|
||||
config.FAC_TANK_DEFS = { 0, 0, 0, 0 }
|
||||
|
||||
-- log path
|
||||
config.LOG_PATH = "/log.txt"
|
||||
-- log mode
|
||||
-- 0 = APPEND (adds to existing file on start)
|
||||
-- 1 = NEW (replaces existing file on start)
|
||||
config.LOG_MODE = 0
|
||||
-- true to log verbose debug messages
|
||||
config.LOG_DEBUG = false
|
||||
|
||||
return config
|
||||
1096
supervisor/configure.lua
Normal file
1096
supervisor/configure.lua
Normal file
File diff suppressed because it is too large
Load Diff
@@ -135,7 +135,7 @@ function facility.new(num_reactors, cooling_conf)
|
||||
|
||||
-- create units
|
||||
for i = 1, num_reactors do
|
||||
table.insert(self.units, unit.new(i, cooling_conf.r_cool[i].BOILERS, cooling_conf.r_cool[i].TURBINES))
|
||||
table.insert(self.units, unit.new(i, cooling_conf.r_cool[i].BoilerCount, cooling_conf.r_cool[i].TurbineCount))
|
||||
table.insert(self.group_map, 0)
|
||||
end
|
||||
|
||||
@@ -152,6 +152,8 @@ function facility.new(num_reactors, cooling_conf)
|
||||
table.insert(self.test_tone_states, false)
|
||||
end
|
||||
|
||||
-- PRIVATE FUNCTIONS --
|
||||
|
||||
-- check if all auto-controlled units completed ramping
|
||||
---@nodiscard
|
||||
local function _all_units_ramped()
|
||||
@@ -228,7 +230,7 @@ function facility.new(num_reactors, cooling_conf)
|
||||
---@class facility
|
||||
local public = {}
|
||||
|
||||
-- ADD/LINK DEVICES --
|
||||
--#region Add/Link Devices
|
||||
|
||||
-- link a redstone RTU session
|
||||
---@param rs_unit unit_session
|
||||
@@ -268,11 +270,9 @@ function facility.new(num_reactors, cooling_conf)
|
||||
for _, v in pairs(self.rtu_list) do util.filter_table(v, function (s) return s.get_session_id() ~= session end) end
|
||||
end
|
||||
|
||||
-- UPDATE --
|
||||
--#endregion
|
||||
|
||||
-- supervisor sessions reporting the list of active RTU sessions
|
||||
---@param rtu_sessions table session list of all connected RTUs
|
||||
function public.report_rtus(rtu_sessions) self.rtu_conn_count = #rtu_sessions end
|
||||
--#region Update
|
||||
|
||||
-- update (iterate) the facility management
|
||||
function public.update()
|
||||
@@ -323,7 +323,7 @@ function facility.new(num_reactors, cooling_conf)
|
||||
-- Run Process Control --
|
||||
-------------------------
|
||||
|
||||
--#region Process Control
|
||||
--#region
|
||||
|
||||
local avg_charge = self.avg_charge.compute()
|
||||
local avg_inflow = self.avg_inflow.compute()
|
||||
@@ -337,7 +337,7 @@ function facility.new(num_reactors, cooling_conf)
|
||||
if state_changed then
|
||||
self.saturated = false
|
||||
|
||||
log.debug("FAC: state changed from " .. PROCESS_NAMES[self.last_mode + 1] .. " to " .. PROCESS_NAMES[self.mode + 1])
|
||||
log.debug(util.c("FAC: state changed from ", PROCESS_NAMES[self.last_mode + 1], " to ", PROCESS_NAMES[self.mode + 1]))
|
||||
|
||||
if (self.last_mode == PROCESS.INACTIVE) or (self.last_mode == PROCESS.GEN_RATE_FAULT_IDLE) then
|
||||
self.start_fail = START_STATUS.OK
|
||||
@@ -375,6 +375,8 @@ function facility.new(num_reactors, cooling_conf)
|
||||
end
|
||||
end
|
||||
|
||||
log.debug(util.c("FAC: computed a max combined burn rate of ", self.max_burn_combined, "mB/t"))
|
||||
|
||||
if blade_count == nil then
|
||||
-- no units
|
||||
log.warning("FAC: cannot start process control with 0 units assigned")
|
||||
@@ -436,7 +438,7 @@ function facility.new(num_reactors, cooling_conf)
|
||||
self.saturated = true
|
||||
|
||||
self.status_text = { "MONITORED MODE", "running reactors at limit" }
|
||||
log.info(util.c("FAC: MAX_BURN process mode started"))
|
||||
log.info("FAC: MAX_BURN process mode started")
|
||||
end
|
||||
|
||||
_allocate_burn_rate(self.max_burn_combined, true)
|
||||
@@ -445,7 +447,7 @@ function facility.new(num_reactors, cooling_conf)
|
||||
if state_changed then
|
||||
self.time_start = now
|
||||
self.status_text = { "BURN RATE MODE", "running" }
|
||||
log.info(util.c("FAC: BURN_RATE process mode started"))
|
||||
log.info("FAC: BURN_RATE process mode started")
|
||||
end
|
||||
|
||||
local unallocated = _allocate_burn_rate(self.burn_target, true)
|
||||
@@ -459,7 +461,7 @@ function facility.new(num_reactors, cooling_conf)
|
||||
self.accumulator = 0
|
||||
|
||||
self.status_text = { "CHARGE MODE", "running control loop" }
|
||||
log.info(util.c("FAC: CHARGE mode starting PID control"))
|
||||
log.info("FAC: CHARGE mode starting PID control")
|
||||
elseif self.last_update ~= charge_update then
|
||||
-- convert to kFE to make constants not microscopic
|
||||
local error = util.round((self.charge_setpoint - avg_charge) / 1000) / 1000
|
||||
@@ -595,7 +597,7 @@ function facility.new(num_reactors, cooling_conf)
|
||||
-- Evaluate Automatic SCRAM --
|
||||
------------------------------
|
||||
|
||||
--#region Automatic SCRAM
|
||||
--#region
|
||||
|
||||
local astatus = self.ascram_status
|
||||
|
||||
@@ -614,7 +616,7 @@ function facility.new(num_reactors, cooling_conf)
|
||||
astatus.matrix_fill = (db.tanks.energy_fill >= ALARM_LIMS.CHARGE_HIGH) or (astatus.matrix_fill and db.tanks.energy_fill > ALARM_LIMS.CHARGE_RE_ENABLE)
|
||||
|
||||
if was_fill and not astatus.matrix_fill then
|
||||
log.info("FAC: charge state of induction matrix entered acceptable range <= " .. (ALARM_LIMS.CHARGE_RE_ENABLE * 100) .. "%")
|
||||
log.info(util.c("FAC: charge state of induction matrix entered acceptable range <= ", ALARM_LIMS.CHARGE_RE_ENABLE * 100, "%"))
|
||||
end
|
||||
|
||||
-- check for critical unit alarms
|
||||
@@ -725,6 +727,8 @@ function facility.new(num_reactors, cooling_conf)
|
||||
-- Handle Redstone I/O --
|
||||
-------------------------
|
||||
|
||||
--#region
|
||||
|
||||
if #self.redstone > 0 then
|
||||
-- handle facility SCRAM
|
||||
if self.io_ctl.digital_read(IO.F_SCRAM) then
|
||||
@@ -754,10 +758,14 @@ function facility.new(num_reactors, cooling_conf)
|
||||
self.io_ctl.digital_write(IO.F_ALARM_ANY, has_any_alarm)
|
||||
end
|
||||
|
||||
--#endregion
|
||||
|
||||
----------------
|
||||
-- Unit Tasks --
|
||||
----------------
|
||||
|
||||
--#region
|
||||
|
||||
local insufficent_po_rate = false
|
||||
local need_emcool = false
|
||||
|
||||
@@ -796,10 +804,14 @@ function facility.new(num_reactors, cooling_conf)
|
||||
end
|
||||
end
|
||||
|
||||
--#endregion
|
||||
|
||||
------------------------
|
||||
-- Update Alarm Tones --
|
||||
------------------------
|
||||
|
||||
--#region
|
||||
|
||||
local allow_test = self.allow_testing and self.test_tone_set
|
||||
|
||||
local alarms = { false, false, false, false, false, false, false, false, false, false, false, false }
|
||||
@@ -886,6 +898,8 @@ function facility.new(num_reactors, cooling_conf)
|
||||
self.test_tone_set = false
|
||||
self.test_tone_reset = true
|
||||
end
|
||||
|
||||
--#endregion
|
||||
end
|
||||
|
||||
-- call the update function of all units in the facility<br>
|
||||
@@ -898,7 +912,9 @@ function facility.new(num_reactors, cooling_conf)
|
||||
end
|
||||
end
|
||||
|
||||
-- COMMANDS --
|
||||
--#endregion
|
||||
|
||||
--#region Commands
|
||||
|
||||
-- SCRAM all reactor units
|
||||
function public.scram_all()
|
||||
@@ -986,7 +1002,9 @@ function facility.new(num_reactors, cooling_conf)
|
||||
}
|
||||
end
|
||||
|
||||
-- SETTINGS --
|
||||
--#endregion
|
||||
|
||||
--#region Settings
|
||||
|
||||
-- set the automatic control group of a unit
|
||||
---@param unit_id integer unit ID
|
||||
@@ -1027,7 +1045,9 @@ function facility.new(num_reactors, cooling_conf)
|
||||
return self.pu_fallback
|
||||
end
|
||||
|
||||
-- DIAGNOSTIC TESTING --
|
||||
--#endregion
|
||||
|
||||
--#region Diagnostic Testing
|
||||
|
||||
-- attempt to set a test tone state
|
||||
---@param id TONE|0 tone ID or 0 to disable all
|
||||
@@ -1067,7 +1087,9 @@ function facility.new(num_reactors, cooling_conf)
|
||||
return self.allow_testing, self.test_alarm_states
|
||||
end
|
||||
|
||||
-- READ STATES/PROPERTIES --
|
||||
--#endregion
|
||||
|
||||
--#region Read States/Properties
|
||||
|
||||
-- get current alarm tone on/off states
|
||||
---@nodiscard
|
||||
@@ -1181,6 +1203,12 @@ function facility.new(num_reactors, cooling_conf)
|
||||
return status
|
||||
end
|
||||
|
||||
--#endregion
|
||||
|
||||
-- supervisor sessions reporting the list of active RTU sessions
|
||||
---@param rtu_sessions table session list of all connected RTUs
|
||||
function public.report_rtus(rtu_sessions) self.rtu_conn_count = #rtu_sessions end
|
||||
|
||||
-- get the units in this facility
|
||||
---@nodiscard
|
||||
function public.get_units() return self.units end
|
||||
|
||||
@@ -4,8 +4,8 @@
|
||||
|
||||
local util = require("scada-common.util")
|
||||
|
||||
local config = require("supervisor.config")
|
||||
local databus = require("supervisor.databus")
|
||||
local supervisor = require("supervisor.supervisor")
|
||||
|
||||
local pgi = require("supervisor.panel.pgi")
|
||||
local style = require("supervisor.panel.style")
|
||||
@@ -88,7 +88,7 @@ local function init(panel)
|
||||
local plc_page = Div{parent=page_div,x=1,y=1,hidden=true}
|
||||
local plc_list = Div{parent=plc_page,x=2,y=2,width=49}
|
||||
|
||||
for i = 1, config.NUM_REACTORS do
|
||||
for i = 1, supervisor.config.UnitCount do
|
||||
local ps_prefix = "plc_" .. i .. "_"
|
||||
local plc_entry = Div{parent=plc_list,height=3,fg_bg=bw_fg_bg}
|
||||
|
||||
|
||||
@@ -2,16 +2,14 @@ local log = require("scada-common.log")
|
||||
local mqueue = require("scada-common.mqueue")
|
||||
local util = require("scada-common.util")
|
||||
|
||||
local config = require("supervisor.config")
|
||||
local databus = require("supervisor.databus")
|
||||
local facility = require("supervisor.facility")
|
||||
|
||||
local svqtypes = require("supervisor.session.svqtypes")
|
||||
|
||||
local coordinator = require("supervisor.session.coordinator")
|
||||
local plc = require("supervisor.session.plc")
|
||||
local pocket = require("supervisor.session.pocket")
|
||||
local rtu = require("supervisor.session.rtu")
|
||||
local svqtypes = require("supervisor.session.svqtypes")
|
||||
|
||||
-- Supervisor Sessions Handler
|
||||
|
||||
@@ -36,7 +34,7 @@ svsessions.SESSION_TYPE = SESSION_TYPE
|
||||
local self = {
|
||||
nic = nil, ---@type nic|nil
|
||||
fp_ok = false,
|
||||
num_reactors = 0,
|
||||
config = nil, ---@type svr_config
|
||||
facility = nil, ---@type facility|nil
|
||||
sessions = { rtu = {}, plc = {}, crd = {}, pdg = {} },
|
||||
next_ids = { rtu = 0, plc = 0, crd = 0, pdg = 0 }
|
||||
@@ -60,7 +58,7 @@ local function _sv_handle_outq(session)
|
||||
if msg ~= nil then
|
||||
if msg.qtype == mqueue.TYPE.PACKET then
|
||||
-- handle a packet to be sent
|
||||
self.nic.transmit(session.r_chan, config.SVR_CHANNEL, msg.message)
|
||||
self.nic.transmit(session.r_chan, self.config.SVR_Channel, msg.message)
|
||||
elseif msg.qtype == mqueue.TYPE.COMMAND then
|
||||
-- handle instruction/notification
|
||||
elseif msg.qtype == mqueue.TYPE.DATA then
|
||||
@@ -135,7 +133,7 @@ local function _shutdown(session)
|
||||
while session.out_queue.ready() do
|
||||
local msg = session.out_queue.pop()
|
||||
if msg ~= nil and msg.qtype == mqueue.TYPE.PACKET then
|
||||
self.nic.transmit(session.r_chan, config.SVR_CHANNEL, msg.message)
|
||||
self.nic.transmit(session.r_chan, self.config.SVR_Channel, msg.message)
|
||||
end
|
||||
end
|
||||
|
||||
@@ -197,13 +195,13 @@ end
|
||||
-- initialize svsessions
|
||||
---@param nic nic network interface device
|
||||
---@param fp_ok boolean front panel active
|
||||
---@param num_reactors integer number of reactors
|
||||
---@param config svr_config supervisor configuration
|
||||
---@param cooling_conf sv_cooling_conf cooling configuration definition
|
||||
function svsessions.init(nic, fp_ok, num_reactors, cooling_conf)
|
||||
function svsessions.init(nic, fp_ok, config, cooling_conf)
|
||||
self.nic = nic
|
||||
self.fp_ok = fp_ok
|
||||
self.num_reactors = num_reactors
|
||||
self.facility = facility.new(num_reactors, cooling_conf)
|
||||
self.config = config
|
||||
self.facility = facility.new(config.UnitCount, cooling_conf)
|
||||
end
|
||||
|
||||
-- find an RTU session by the computer ID
|
||||
@@ -280,14 +278,14 @@ end
|
||||
---@param version string
|
||||
---@return integer|false session_id
|
||||
function svsessions.establish_plc_session(source_addr, for_reactor, version)
|
||||
if svsessions.get_reactor_session(for_reactor) == nil and for_reactor >= 1 and for_reactor <= self.num_reactors then
|
||||
if svsessions.get_reactor_session(for_reactor) == nil and for_reactor >= 1 and for_reactor <= self.config.UnitCount then
|
||||
---@class plc_session_struct
|
||||
local plc_s = {
|
||||
s_type = "plc",
|
||||
open = true,
|
||||
reactor = for_reactor,
|
||||
version = version,
|
||||
r_chan = config.PLC_CHANNEL,
|
||||
r_chan = self.config.PLC_Channel,
|
||||
s_addr = source_addr,
|
||||
in_queue = mqueue.new(),
|
||||
out_queue = mqueue.new(),
|
||||
@@ -296,8 +294,7 @@ function svsessions.establish_plc_session(source_addr, for_reactor, version)
|
||||
|
||||
local id = self.next_ids.plc
|
||||
|
||||
plc_s.instance = plc.new_session(id, source_addr, for_reactor, plc_s.in_queue, plc_s.out_queue,
|
||||
config.PLC_TIMEOUT, self.fp_ok)
|
||||
plc_s.instance = plc.new_session(id, source_addr, for_reactor, plc_s.in_queue, plc_s.out_queue, self.config.PLC_Timeout, self.fp_ok)
|
||||
table.insert(self.sessions.plc, plc_s)
|
||||
|
||||
local units = self.facility.get_units()
|
||||
@@ -305,8 +302,7 @@ function svsessions.establish_plc_session(source_addr, for_reactor, version)
|
||||
|
||||
local mt = {
|
||||
---@param s plc_session_struct
|
||||
__tostring = function (s) return util.c("PLC [", s.instance.get_id(), "] for reactor #", s.reactor,
|
||||
" (@", s.s_addr, ")") end
|
||||
__tostring = function (s) return util.c("PLC [", s.instance.get_id(), "] for reactor #", s.reactor, " (@", s.s_addr, ")") end
|
||||
}
|
||||
|
||||
setmetatable(plc_s, mt)
|
||||
@@ -336,7 +332,7 @@ function svsessions.establish_rtu_session(source_addr, advertisement, version)
|
||||
s_type = "rtu",
|
||||
open = true,
|
||||
version = version,
|
||||
r_chan = config.RTU_CHANNEL,
|
||||
r_chan = self.config.RTU_Channel,
|
||||
s_addr = source_addr,
|
||||
in_queue = mqueue.new(),
|
||||
out_queue = mqueue.new(),
|
||||
@@ -345,8 +341,7 @@ function svsessions.establish_rtu_session(source_addr, advertisement, version)
|
||||
|
||||
local id = self.next_ids.rtu
|
||||
|
||||
rtu_s.instance = rtu.new_session(id, source_addr, rtu_s.in_queue, rtu_s.out_queue, config.RTU_TIMEOUT,
|
||||
advertisement, self.facility, self.fp_ok)
|
||||
rtu_s.instance = rtu.new_session(id, source_addr, rtu_s.in_queue, rtu_s.out_queue, self.config.RTU_Timeout, advertisement, self.facility, self.fp_ok)
|
||||
table.insert(self.sessions.rtu, rtu_s)
|
||||
|
||||
local mt = {
|
||||
@@ -377,7 +372,7 @@ function svsessions.establish_crd_session(source_addr, version)
|
||||
s_type = "crd",
|
||||
open = true,
|
||||
version = version,
|
||||
r_chan = config.CRD_CHANNEL,
|
||||
r_chan = self.config.CRD_Channel,
|
||||
s_addr = source_addr,
|
||||
in_queue = mqueue.new(),
|
||||
out_queue = mqueue.new(),
|
||||
@@ -386,8 +381,7 @@ function svsessions.establish_crd_session(source_addr, version)
|
||||
|
||||
local id = self.next_ids.crd
|
||||
|
||||
crd_s.instance = coordinator.new_session(id, source_addr, crd_s.in_queue, crd_s.out_queue, config.CRD_TIMEOUT,
|
||||
self.facility, self.fp_ok)
|
||||
crd_s.instance = coordinator.new_session(id, source_addr, crd_s.in_queue, crd_s.out_queue, self.config.CRD_Timeout, self.facility, self.fp_ok)
|
||||
table.insert(self.sessions.crd, crd_s)
|
||||
|
||||
local mt = {
|
||||
@@ -421,7 +415,7 @@ function svsessions.establish_pdg_session(source_addr, version)
|
||||
s_type = "pkt",
|
||||
open = true,
|
||||
version = version,
|
||||
r_chan = config.PKT_CHANNEL,
|
||||
r_chan = self.config.PKT_Channel,
|
||||
s_addr = source_addr,
|
||||
in_queue = mqueue.new(),
|
||||
out_queue = mqueue.new(),
|
||||
@@ -430,8 +424,7 @@ function svsessions.establish_pdg_session(source_addr, version)
|
||||
|
||||
local id = self.next_ids.pdg
|
||||
|
||||
pdg_s.instance = pocket.new_session(id, source_addr, pdg_s.in_queue, pdg_s.out_queue, config.PKT_TIMEOUT, self.facility,
|
||||
self.fp_ok)
|
||||
pdg_s.instance = pocket.new_session(id, source_addr, pdg_s.in_queue, pdg_s.out_queue, self.config.PKT_Timeout, self.facility, self.fp_ok)
|
||||
table.insert(self.sessions.pdg, pdg_s)
|
||||
|
||||
local mt = {
|
||||
|
||||
@@ -14,70 +14,71 @@ local util = require("scada-common.util")
|
||||
|
||||
local core = require("graphics.core")
|
||||
|
||||
local config = require("supervisor.config")
|
||||
local configure = require("supervisor.configure")
|
||||
local databus = require("supervisor.databus")
|
||||
local renderer = require("supervisor.renderer")
|
||||
local supervisor = require("supervisor.supervisor")
|
||||
|
||||
local svsessions = require("supervisor.session.svsessions")
|
||||
|
||||
local SUPERVISOR_VERSION = "v1.1.0"
|
||||
local SUPERVISOR_VERSION = "v1.2.11"
|
||||
|
||||
local println = util.println
|
||||
local println_ts = util.println_ts
|
||||
|
||||
----------------------------------------
|
||||
-- config validation
|
||||
-- get configuration
|
||||
----------------------------------------
|
||||
|
||||
if not supervisor.load_config() then
|
||||
-- try to reconfigure (user action)
|
||||
local success, error = configure.configure(true)
|
||||
if success then
|
||||
if not supervisor.load_config() then
|
||||
println("failed to load a valid configuration, please reconfigure")
|
||||
return
|
||||
end
|
||||
else
|
||||
println("configuration error: " .. error)
|
||||
return
|
||||
end
|
||||
end
|
||||
|
||||
local config = supervisor.config
|
||||
|
||||
local cfv = util.new_validator()
|
||||
|
||||
cfv.assert_channel(config.SVR_CHANNEL)
|
||||
cfv.assert_channel(config.PLC_CHANNEL)
|
||||
cfv.assert_channel(config.RTU_CHANNEL)
|
||||
cfv.assert_channel(config.CRD_CHANNEL)
|
||||
cfv.assert_channel(config.PKT_CHANNEL)
|
||||
cfv.assert_type_int(config.TRUSTED_RANGE)
|
||||
cfv.assert_type_num(config.PLC_TIMEOUT)
|
||||
cfv.assert_min(config.PLC_TIMEOUT, 2)
|
||||
cfv.assert_type_num(config.RTU_TIMEOUT)
|
||||
cfv.assert_min(config.RTU_TIMEOUT, 2)
|
||||
cfv.assert_type_num(config.CRD_TIMEOUT)
|
||||
cfv.assert_min(config.CRD_TIMEOUT, 2)
|
||||
cfv.assert_type_num(config.PKT_TIMEOUT)
|
||||
cfv.assert_min(config.PKT_TIMEOUT, 2)
|
||||
cfv.assert_type_int(config.NUM_REACTORS)
|
||||
cfv.assert_type_table(config.REACTOR_COOLING)
|
||||
cfv.assert_type_int(config.FAC_TANK_MODE)
|
||||
cfv.assert_type_table(config.FAC_TANK_DEFS)
|
||||
cfv.assert_type_str(config.LOG_PATH)
|
||||
cfv.assert_type_int(config.LOG_MODE)
|
||||
cfv.assert_eq(#config.CoolingConfig, config.UnitCount)
|
||||
assert(cfv.valid(), "startup> the number of reactor cooling configurations is different than the number of units")
|
||||
|
||||
assert(cfv.valid(), "bad config file: missing/invalid fields")
|
||||
for i = 1, config.UnitCount do
|
||||
cfv.assert_type_table(config.CoolingConfig[i])
|
||||
assert(cfv.valid(), "startup> missing cooling entry for reactor unit " .. i)
|
||||
cfv.assert_type_int(config.CoolingConfig[i].BoilerCount)
|
||||
cfv.assert_type_int(config.CoolingConfig[i].TurbineCount)
|
||||
cfv.assert_type_bool(config.CoolingConfig[i].TankConnection)
|
||||
assert(cfv.valid(), "startup> missing boiler/turbine/tank fields for reactor unit " .. i)
|
||||
cfv.assert_range(config.CoolingConfig[i].BoilerCount, 0, 2)
|
||||
cfv.assert_range(config.CoolingConfig[i].TurbineCount, 1, 3)
|
||||
assert(cfv.valid(), "startup> out-of-range number of boilers and/or turbines provided for reactor unit " .. i)
|
||||
end
|
||||
|
||||
assert((config.FAC_TANK_MODE == 0) or (config.NUM_REACTORS == #config.FAC_TANK_DEFS),
|
||||
"bad config file: FAC_TANK_DEFS length not equal to NUM_REACTORS")
|
||||
if config.FacilityTankMode > 0 then
|
||||
assert(config.UnitCount == #config.FacilityTankDefs, "startup> the number of facility tank definitions must be equal to the number of units in facility tank mode")
|
||||
|
||||
cfv.assert_eq(#config.REACTOR_COOLING, config.NUM_REACTORS)
|
||||
assert(cfv.valid(), "config: number of cooling configs different than number of units")
|
||||
|
||||
for i = 1, config.NUM_REACTORS do
|
||||
cfv.assert_type_table(config.REACTOR_COOLING[i])
|
||||
assert(cfv.valid(), "config: missing cooling entry for reactor " .. i)
|
||||
cfv.assert_type_int(config.REACTOR_COOLING[i].BOILERS)
|
||||
cfv.assert_type_int(config.REACTOR_COOLING[i].TURBINES)
|
||||
cfv.assert_type_bool(config.REACTOR_COOLING[i].TANK)
|
||||
assert(cfv.valid(), "config: missing boilers/turbines for reactor " .. i)
|
||||
cfv.assert_min(config.REACTOR_COOLING[i].BOILERS, 0)
|
||||
cfv.assert_min(config.REACTOR_COOLING[i].TURBINES, 1)
|
||||
assert(cfv.valid(), "config: bad number of boilers/turbines for reactor " .. i)
|
||||
for i = 1, config.UnitCount do
|
||||
local def = config.FacilityTankDefs[i]
|
||||
cfv.assert_type_int(def)
|
||||
cfv.assert_range(def, 0, 2)
|
||||
assert(cfv.valid(), "startup> invalid facility tank definition for reactor unit " .. i)
|
||||
end
|
||||
end
|
||||
|
||||
----------------------------------------
|
||||
-- log init
|
||||
----------------------------------------
|
||||
|
||||
log.init(config.LOG_PATH, config.LOG_MODE, config.LOG_DEBUG == true)
|
||||
log.init(config.LogPath, config.LogMode, config.LogDebug)
|
||||
|
||||
log.info("========================================")
|
||||
log.info("BOOTING supervisor.startup " .. SUPERVISOR_VERSION)
|
||||
@@ -102,8 +103,8 @@ local function main()
|
||||
ppm.mount_all()
|
||||
|
||||
-- message authentication init
|
||||
if type(config.AUTH_KEY) == "string" then
|
||||
network.init_mac(config.AUTH_KEY)
|
||||
if type(config.AuthKey) == "string" and string.len(config.AuthKey) > 0 then
|
||||
network.init_mac(config.AuthKey)
|
||||
end
|
||||
|
||||
-- get modem
|
||||
|
||||
@@ -2,8 +2,6 @@ local comms = require("scada-common.comms")
|
||||
local log = require("scada-common.log")
|
||||
local util = require("scada-common.util")
|
||||
|
||||
local config = require("supervisor.config")
|
||||
|
||||
local svsessions = require("supervisor.session.svsessions")
|
||||
|
||||
local supervisor = {}
|
||||
@@ -13,6 +11,79 @@ local DEVICE_TYPE = comms.DEVICE_TYPE
|
||||
local ESTABLISH_ACK = comms.ESTABLISH_ACK
|
||||
local MGMT_TYPE = comms.MGMT_TYPE
|
||||
|
||||
---@type svr_config
|
||||
local config = {}
|
||||
|
||||
supervisor.config = config
|
||||
|
||||
-- load the supervisor configuration
|
||||
function supervisor.load_config()
|
||||
if not settings.load("/supervisor.settings") then return false end
|
||||
|
||||
config.UnitCount = settings.get("UnitCount")
|
||||
config.CoolingConfig = settings.get("CoolingConfig")
|
||||
config.FacilityTankMode = settings.get("FacilityTankMode")
|
||||
config.FacilityTankDefs = settings.get("FacilityTankDefs")
|
||||
|
||||
config.SVR_Channel = settings.get("SVR_Channel")
|
||||
config.PLC_Channel = settings.get("PLC_Channel")
|
||||
config.RTU_Channel = settings.get("RTU_Channel")
|
||||
config.CRD_Channel = settings.get("CRD_Channel")
|
||||
config.PKT_Channel = settings.get("PKT_Channel")
|
||||
|
||||
config.PLC_Timeout = settings.get("PLC_Timeout")
|
||||
config.RTU_Timeout = settings.get("RTU_Timeout")
|
||||
config.CRD_Timeout = settings.get("CRD_Timeout")
|
||||
config.PKT_Timeout = settings.get("PKT_Timeout")
|
||||
|
||||
config.TrustedRange = settings.get("TrustedRange")
|
||||
config.AuthKey = settings.get("AuthKey")
|
||||
|
||||
config.LogMode = settings.get("LogMode")
|
||||
config.LogPath = settings.get("LogPath")
|
||||
config.LogDebug = settings.get("LogDebug")
|
||||
|
||||
local cfv = util.new_validator()
|
||||
|
||||
cfv.assert_type_int(config.UnitCount)
|
||||
cfv.assert_range(config.UnitCount, 1, 4)
|
||||
|
||||
cfv.assert_type_table(config.CoolingConfig)
|
||||
cfv.assert_type_table(config.FacilityTankDefs)
|
||||
cfv.assert_type_int(config.FacilityTankMode)
|
||||
cfv.assert_range(config.FacilityTankMode, 0, 8)
|
||||
|
||||
cfv.assert_channel(config.SVR_Channel)
|
||||
cfv.assert_channel(config.PLC_Channel)
|
||||
cfv.assert_channel(config.RTU_Channel)
|
||||
cfv.assert_channel(config.CRD_Channel)
|
||||
cfv.assert_channel(config.PKT_Channel)
|
||||
|
||||
cfv.assert_type_num(config.PLC_Timeout)
|
||||
cfv.assert_min(config.PLC_Timeout, 2)
|
||||
cfv.assert_type_num(config.RTU_Timeout)
|
||||
cfv.assert_min(config.RTU_Timeout, 2)
|
||||
cfv.assert_type_num(config.CRD_Timeout)
|
||||
cfv.assert_min(config.CRD_Timeout, 2)
|
||||
cfv.assert_type_num(config.PKT_Timeout)
|
||||
cfv.assert_min(config.PKT_Timeout, 2)
|
||||
|
||||
cfv.assert_type_num(config.TrustedRange)
|
||||
cfv.assert_min(config.TrustedRange, 0)
|
||||
|
||||
if type(config.AuthKey) == "string" then
|
||||
local len = string.len(config.AuthKey)
|
||||
cfv.assert_eq(len == 0 or len >= 8, true)
|
||||
end
|
||||
|
||||
cfv.assert_type_int(config.LogMode)
|
||||
cfv.assert_range(config.LogMode, 0, 1)
|
||||
cfv.assert_type_str(config.LogPath)
|
||||
cfv.assert_type_bool(config.LogDebug)
|
||||
|
||||
return cfv.valid()
|
||||
end
|
||||
|
||||
-- supervisory controller communications
|
||||
---@nodiscard
|
||||
---@param _version string supervisor version
|
||||
@@ -23,32 +94,23 @@ function supervisor.comms(_version, nic, fp_ok)
|
||||
-- print a log message to the terminal as long as the UI isn't running
|
||||
local function println(message) if not fp_ok then util.println_ts(message) end end
|
||||
|
||||
-- channel list from config
|
||||
local svr_channel = config.SVR_CHANNEL
|
||||
local plc_channel = config.PLC_CHANNEL
|
||||
local rtu_channel = config.RTU_CHANNEL
|
||||
local crd_channel = config.CRD_CHANNEL
|
||||
local pkt_channel = config.PKT_CHANNEL
|
||||
|
||||
-- configuration data
|
||||
local num_reactors = config.NUM_REACTORS
|
||||
---@class sv_cooling_conf
|
||||
local cooling_conf = { r_cool = config.REACTOR_COOLING, fac_tank_mode = config.FAC_TANK_MODE, fac_tank_defs = config.FAC_TANK_DEFS }
|
||||
local cooling_conf = { r_cool = config.CoolingConfig, fac_tank_mode = config.FacilityTankMode, fac_tank_defs = config.FacilityTankDefs }
|
||||
|
||||
local self = {
|
||||
last_est_acks = {}
|
||||
}
|
||||
|
||||
comms.set_trusted_range(config.TRUSTED_RANGE)
|
||||
comms.set_trusted_range(config.TrustedRange)
|
||||
|
||||
-- PRIVATE FUNCTIONS --
|
||||
|
||||
-- configure modem channels
|
||||
nic.closeAll()
|
||||
nic.open(svr_channel)
|
||||
nic.open(config.SVR_Channel)
|
||||
|
||||
-- pass modem, status, and config data to svsessions
|
||||
svsessions.init(nic, fp_ok, num_reactors, cooling_conf)
|
||||
svsessions.init(nic, fp_ok, config, cooling_conf)
|
||||
|
||||
-- send an establish request response
|
||||
---@param packet scada_packet
|
||||
@@ -61,7 +123,7 @@ function supervisor.comms(_version, nic, fp_ok)
|
||||
m_pkt.make(MGMT_TYPE.ESTABLISH, { ack, data })
|
||||
s_pkt.make(packet.src_addr(), packet.seq_num() + 1, PROTOCOL.SCADA_MGMT, m_pkt.raw_sendable())
|
||||
|
||||
nic.transmit(packet.remote_channel(), svr_channel, s_pkt)
|
||||
nic.transmit(packet.remote_channel(), config.SVR_Channel, s_pkt)
|
||||
self.last_est_acks[packet.src_addr()] = ack
|
||||
end
|
||||
|
||||
@@ -124,9 +186,9 @@ function supervisor.comms(_version, nic, fp_ok)
|
||||
local src_addr = packet.scada_frame.src_addr()
|
||||
local protocol = packet.scada_frame.protocol()
|
||||
|
||||
if l_chan ~= svr_channel then
|
||||
if l_chan ~= config.SVR_Channel then
|
||||
log.debug("received packet on unconfigured channel " .. l_chan, true)
|
||||
elseif r_chan == plc_channel then
|
||||
elseif r_chan == config.PLC_Channel then
|
||||
-- look for an associated session
|
||||
local session = svsessions.find_plc_session(src_addr)
|
||||
|
||||
@@ -137,9 +199,8 @@ function supervisor.comms(_version, nic, fp_ok)
|
||||
-- pass the packet onto the session handler
|
||||
session.in_queue.push_packet(packet)
|
||||
else
|
||||
-- unknown session, force a re-link
|
||||
log.debug("PLC_ESTABLISH: no session but not an establish, forcing relink")
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
|
||||
-- any other packet should be session related, discard it
|
||||
log.debug("discarding RPLC packet without a known session")
|
||||
end
|
||||
elseif protocol == PROTOCOL.SCADA_MGMT then
|
||||
---@cast packet mgmt_frame
|
||||
@@ -201,7 +262,7 @@ function supervisor.comms(_version, nic, fp_ok)
|
||||
else
|
||||
log.debug(util.c("illegal packet type ", protocol, " on PLC channel"))
|
||||
end
|
||||
elseif r_chan == rtu_channel then
|
||||
elseif r_chan == config.RTU_Channel then
|
||||
-- look for an associated session
|
||||
local session = svsessions.find_rtu_session(src_addr)
|
||||
|
||||
@@ -265,7 +326,7 @@ function supervisor.comms(_version, nic, fp_ok)
|
||||
else
|
||||
log.debug(util.c("illegal packet type ", protocol, " on RTU channel"))
|
||||
end
|
||||
elseif r_chan == crd_channel then
|
||||
elseif r_chan == config.CRD_Channel then
|
||||
-- look for an associated session
|
||||
local session = svsessions.find_crd_session(src_addr)
|
||||
|
||||
@@ -299,7 +360,7 @@ function supervisor.comms(_version, nic, fp_ok)
|
||||
println(util.c("CRD (", firmware_v, ") [@", src_addr, "] \xbb connected"))
|
||||
log.info(util.c("CRD_ESTABLISH: coordinator (", firmware_v, ") [@", src_addr, "] connected with session ID ", s_id))
|
||||
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.ALLOW, { num_reactors, cooling_conf })
|
||||
_send_establish(packet.scada_frame, ESTABLISH_ACK.ALLOW, { config.UnitCount, cooling_conf })
|
||||
else
|
||||
if last_ack ~= ESTABLISH_ACK.COLLISION then
|
||||
log.info("CRD_ESTABLISH: denied new coordinator [@" .. src_addr .. "] due to already being connected to another coordinator")
|
||||
@@ -332,7 +393,7 @@ function supervisor.comms(_version, nic, fp_ok)
|
||||
else
|
||||
log.debug(util.c("illegal packet type ", protocol, " on coordinator channel"))
|
||||
end
|
||||
elseif r_chan == pkt_channel then
|
||||
elseif r_chan == config.PKT_Channel then
|
||||
-- look for an associated session
|
||||
local session = svsessions.find_pdg_session(src_addr)
|
||||
|
||||
|
||||
@@ -77,7 +77,6 @@ function unit.new(reactor_id, num_boilers, num_turbines)
|
||||
tanks = {},
|
||||
snas = {},
|
||||
envd = {},
|
||||
sna_prod_rate = 0,
|
||||
-- redstone control
|
||||
io_ctl = nil, ---@type rs_controller
|
||||
valves = {}, ---@type unit_valves
|
||||
@@ -256,7 +255,7 @@ function unit.new(reactor_id, num_boilers, num_turbines)
|
||||
|
||||
-- PRIVATE FUNCTIONS --
|
||||
|
||||
--#region time derivative utility functions
|
||||
--#region Time Derivative Utility Functions
|
||||
|
||||
-- compute a change with respect to time of the given value
|
||||
---@param key string value key
|
||||
@@ -331,7 +330,7 @@ function unit.new(reactor_id, num_boilers, num_turbines)
|
||||
|
||||
--#endregion
|
||||
|
||||
--#region redstone I/O
|
||||
--#region Redstone I/O
|
||||
|
||||
-- create a generic valve interface
|
||||
---@nodiscard
|
||||
@@ -398,8 +397,7 @@ function unit.new(reactor_id, num_boilers, num_turbines)
|
||||
---@class reactor_unit
|
||||
local public = {}
|
||||
|
||||
-- ADD/LINK DEVICES --
|
||||
--#region
|
||||
--#region Add/Link Devices
|
||||
|
||||
-- link the PLC
|
||||
---@param plc_session plc_session_struct
|
||||
@@ -489,7 +487,7 @@ function unit.new(reactor_id, num_boilers, num_turbines)
|
||||
|
||||
--#endregion
|
||||
|
||||
-- UPDATE SESSION --
|
||||
--#region Update Session
|
||||
|
||||
-- update (iterate) this unit
|
||||
function public.update()
|
||||
@@ -557,13 +555,15 @@ function unit.new(reactor_id, num_boilers, num_turbines)
|
||||
end
|
||||
end
|
||||
|
||||
-- AUTO CONTROL OPERATIONS --
|
||||
--#region
|
||||
--#endregion
|
||||
|
||||
--#region Auto Control Operations
|
||||
|
||||
-- engage automatic control
|
||||
function public.auto_engage()
|
||||
self.auto_engaged = true
|
||||
if self.plc_i ~= nil then
|
||||
log.debug(util.c("UNIT ", self.r_id, ": engaged auto control"))
|
||||
self.plc_i.auto_lock(true)
|
||||
end
|
||||
end
|
||||
@@ -572,6 +572,7 @@ function unit.new(reactor_id, num_boilers, num_turbines)
|
||||
function public.auto_disengage()
|
||||
self.auto_engaged = false
|
||||
if self.plc_i ~= nil then
|
||||
log.debug(util.c("UNIT ", self.r_id, ": disengaged auto control"))
|
||||
self.plc_i.auto_lock(false)
|
||||
self.db.control.br100 = 0
|
||||
end
|
||||
@@ -582,12 +583,12 @@ function unit.new(reactor_id, num_boilers, num_turbines)
|
||||
---@nodiscard
|
||||
---@return integer lim_br100
|
||||
function public.auto_get_effective_limit()
|
||||
if (not self.db.control.ready) or self.db.control.degraded or self.plc_cache.rps_trip then
|
||||
self.db.control.br100 = 0
|
||||
local ctrl = self.db.control
|
||||
if (not ctrl.ready) or ctrl.degraded or self.plc_cache.rps_trip then
|
||||
-- log.debug(util.c("UNIT ", self.r_id, ": effective limit is zero! ready[", ctrl.ready, "] degraded[", ctrl.degraded, "] rps_trip[", self.plc_cache.rps_trip, "]"))
|
||||
ctrl.br100 = 0
|
||||
return 0
|
||||
else
|
||||
return self.db.control.lim_br100
|
||||
end
|
||||
else return ctrl.lim_br100 end
|
||||
end
|
||||
|
||||
-- set the automatic burn rate based on the last set burn rate in 100ths
|
||||
@@ -595,8 +596,8 @@ function unit.new(reactor_id, num_boilers, num_turbines)
|
||||
function public.auto_commit_br100(ramp)
|
||||
if self.auto_engaged then
|
||||
if self.plc_i ~= nil then
|
||||
log.debug(util.c("UNIT ", self.r_id, ": commit br100 of ", self.db.control.br100, " with ramp set to ", ramp))
|
||||
self.plc_i.auto_set_burn(self.db.control.br100 / 100, ramp)
|
||||
|
||||
if ramp then self.ramp_target_br100 = self.db.control.br100 end
|
||||
end
|
||||
end
|
||||
@@ -643,8 +644,7 @@ function unit.new(reactor_id, num_boilers, num_turbines)
|
||||
|
||||
--#endregion
|
||||
|
||||
-- OPERATIONS --
|
||||
--#region
|
||||
--#region Operations
|
||||
|
||||
-- queue a command to disable the reactor
|
||||
function public.disable()
|
||||
@@ -724,8 +724,7 @@ function unit.new(reactor_id, num_boilers, num_turbines)
|
||||
|
||||
--#endregion
|
||||
|
||||
-- READ STATES/PROPERTIES --
|
||||
--#region
|
||||
--#region Read States/Properties
|
||||
|
||||
-- check if an alarm of at least a certain priority level is tripped
|
||||
---@nodiscard
|
||||
@@ -855,13 +854,15 @@ function unit.new(reactor_id, num_boilers, num_turbines)
|
||||
status.tanks[tank.get_device_idx()] = { tank.is_faulted(), db.formed, db.state, db.tanks }
|
||||
end
|
||||
|
||||
-- basic SNA statistical information
|
||||
local total_peak = 0
|
||||
-- SNA statistical information
|
||||
local total_peak, total_avail, total_out = 0, 0, 0
|
||||
for i = 1, #self.snas do
|
||||
local db = self.snas[i].get_db() ---@type sna_session_db
|
||||
total_peak = total_peak + db.state.peak_production
|
||||
total_avail = total_avail + db.state.production_rate
|
||||
total_out = total_out + math.min(db.tanks.input.amount / 10, db.state.production_rate)
|
||||
end
|
||||
status.sna = { #self.snas, public.get_sna_rate(), total_peak }
|
||||
status.sna = { #self.snas, total_peak, total_avail, total_out }
|
||||
|
||||
-- radiation monitors (environment detectors)
|
||||
status.envds = {}
|
||||
@@ -874,7 +875,7 @@ function unit.new(reactor_id, num_boilers, num_turbines)
|
||||
return status
|
||||
end
|
||||
|
||||
-- get the current total [max] production rate is
|
||||
-- get the current total max production rate
|
||||
---@nodiscard
|
||||
---@return number total_avail_rate
|
||||
function public.get_sna_rate()
|
||||
|
||||
@@ -54,9 +54,7 @@ function logic.update_annunciator(self)
|
||||
-- variables for boiler, or reactor if no boilers used
|
||||
local total_boil_rate = 0.0
|
||||
|
||||
-------------
|
||||
-- REACTOR --
|
||||
-------------
|
||||
--#region Reactor
|
||||
|
||||
annunc.AutoControl = self.auto_engaged
|
||||
|
||||
@@ -143,9 +141,9 @@ function logic.update_annunciator(self)
|
||||
self.plc_cache.ok = false
|
||||
end
|
||||
|
||||
---------------
|
||||
-- MISC RTUs --
|
||||
---------------
|
||||
--#endregion
|
||||
|
||||
--#region Misc RTUs
|
||||
|
||||
local max_rad, any_faulted = 0, false
|
||||
|
||||
@@ -170,9 +168,9 @@ function logic.update_annunciator(self)
|
||||
end
|
||||
end
|
||||
|
||||
-------------
|
||||
-- BOILERS --
|
||||
-------------
|
||||
--#endregion
|
||||
|
||||
--#region Boilers
|
||||
|
||||
local boilers_ready = num_boilers == #self.boilers
|
||||
|
||||
@@ -230,9 +228,9 @@ function logic.update_annunciator(self)
|
||||
boiler_water_dt_sum = _get_dt(DT_KEYS.ReactorCCool)
|
||||
end
|
||||
|
||||
---------------------------
|
||||
-- COOLANT FEED MISMATCH --
|
||||
---------------------------
|
||||
--#endregion
|
||||
|
||||
--#region Coolant Feed Mismatch
|
||||
|
||||
-- check coolant feed mismatch if using boilers, otherwise calculate with reactor
|
||||
local cfmismatch = false
|
||||
@@ -263,9 +261,9 @@ function logic.update_annunciator(self)
|
||||
|
||||
annunc.CoolantFeedMismatch = cfmismatch
|
||||
|
||||
--------------
|
||||
-- TURBINES --
|
||||
--------------
|
||||
--#endregion
|
||||
|
||||
--#region Turbines
|
||||
|
||||
local turbines_ready = num_turbines == #self.turbines
|
||||
|
||||
@@ -340,6 +338,8 @@ function logic.update_annunciator(self)
|
||||
annunc.TurbineTrip[idx] = has_steam and db.state.flow_rate == 0
|
||||
end
|
||||
|
||||
--#endregion
|
||||
|
||||
-- update auto control ready state for this unit
|
||||
self.db.control.ready = plc_ready and boilers_ready and turbines_ready
|
||||
end
|
||||
|
||||
56
test/watch_psil_allocs.lua
Normal file
56
test/watch_psil_allocs.lua
Normal file
@@ -0,0 +1,56 @@
|
||||
-- add this to psil:
|
||||
|
||||
--[[
|
||||
-- count the number of subscribers in this PSIL instance
|
||||
---@return integer count
|
||||
function public.count()
|
||||
local c = 0
|
||||
for _, val in pairs(ic) do
|
||||
for _ = 1, #val.subscribers do c = c + 1 end
|
||||
end
|
||||
return c
|
||||
end
|
||||
]]--
|
||||
|
||||
|
||||
-- add this to coordinator iocontrol front panel heartbeat function:
|
||||
|
||||
--[[
|
||||
if io.facility then
|
||||
local count = io.facility.ps.count()
|
||||
|
||||
count = count + io.facility.env_d_ps.count()
|
||||
|
||||
for x = 1, #io.facility.induction_ps_tbl do
|
||||
count = count + io.facility.induction_ps_tbl[x].count()
|
||||
end
|
||||
|
||||
for x = 1, #io.facility.sps_ps_tbl do
|
||||
count = count + io.facility.sps_ps_tbl[x].count()
|
||||
end
|
||||
|
||||
for x = 1, #io.facility.tank_ps_tbl do
|
||||
count = count + io.facility.tank_ps_tbl[x].count()
|
||||
end
|
||||
|
||||
for i = 1, #io.units do
|
||||
local entry = io.units[i] ---@type ioctl_unit
|
||||
|
||||
count = count + entry.unit_ps.count()
|
||||
|
||||
for x = 1, #entry.boiler_ps_tbl do
|
||||
count = count + entry.boiler_ps_tbl[x].count()
|
||||
end
|
||||
|
||||
for x = 1, #entry.turbine_ps_tbl do
|
||||
count = count + entry.turbine_ps_tbl[x].count()
|
||||
end
|
||||
|
||||
for x = 1, #entry.tank_ps_tbl do
|
||||
count = count + entry.tank_ps_tbl[x].count()
|
||||
end
|
||||
end
|
||||
|
||||
log.debug(count)
|
||||
end
|
||||
]]--
|
||||
Reference in New Issue
Block a user