Compare commits

...

52 Commits

Author SHA1 Message Date
Mikayla
f59f484e7b Merge pull request #317 from MikaylaFischler/devel
2023.08.22 Release
2023-08-22 18:42:21 -04:00
Mikayla Fischler
0fe9b391d8 #313 installer self-update fix, added update command for it 2023-08-21 22:47:00 -04:00
Mikayla
97f0191875 #313 installer self update 2023-08-22 02:18:25 +00:00
Mikayla Fischler
70db8d782c fixed unit dynamic tank state indicator 2023-08-21 22:05:02 -04:00
Mikayla
2acd166c3e Merge pull request #316 from MikaylaFischler/232-waste-valve-and-flow-monitoring-display
232 Waste Valve and Flow Monitoring Display
2023-08-21 21:54:22 -04:00
Mikayla Fischler
c78f7e173a #232 cleanup, changed antimatter rate to be integer on main display 2023-08-21 21:53:31 -04:00
Mikayla Fischler
99a0b0a55a #232 documentation and refactor 2023-08-21 21:44:15 -04:00
Mikayla Fischler
6e51e70b62 #232 cleanup and fixes 2023-08-21 21:37:56 -04:00
Mikayla Fischler
fd2abad5cf changed some green/red indicators to be green/gray for contrast 2023-08-21 21:35:32 -04:00
Mikayla Fischler
b93c6b7c6e fixes per luacheck 2023-08-20 23:53:49 -04:00
Mikayla Fischler
8b3f558f68 Merge branch 'devel' into 232-waste-valve-and-flow-monitoring-display 2023-08-20 23:43:07 -04:00
Mikayla Fischler
8c5289867c #232 updated coordinator monitor disconnect/reconnect handling for changes 2023-08-20 23:28:48 -04:00
Mikayla Fischler
d179920565 #232 option to disable flow view screen for legacy setups 2023-08-20 23:23:23 -04:00
Mikayla Fischler
504ee0594f #315 switch off dynamic tank fill mode if emergency coolant is required 2023-08-20 22:56:51 -04:00
Mikayla Fischler
a92f182156 #232 fixed incorrect arrows on turbine flow view 2023-08-20 22:53:14 -04:00
Mikayla Fischler
c5d38a5584 #232 added container mode indicators for tanks 2023-08-20 17:30:34 -04:00
Mikayla Fischler
9bf07e6c3e completed work on updated pipenet 2023-08-20 17:04:14 -04:00
Mikayla Fischler
7656936982 #232 cleanup, added general stats 2023-08-20 16:52:12 -04:00
Mikayla Fischler
f477ad9426 #232 re-indexed valve IDs 2023-08-19 23:28:03 -04:00
Mikayla Fischler
59950e9d15 #232 connected valve indicators 2023-08-19 23:24:20 -04:00
Mikayla Fischler
11d86d92eb #232 bugfixes and linked up indicators to data 2023-08-19 20:06:37 -04:00
Mikayla Fischler
1275f61113 #232 refactor and fixed sv config verify 2023-08-19 13:42:07 -04:00
Mikayla Fischler
d17e2b8321 #232 completed display of flow/dynamic tank/sps, dynamically sized 2023-08-19 13:38:05 -04:00
Mikayla Fischler
ce780c3d72 added common color pairs to coordinator style 2023-08-13 00:51:37 -04:00
Mikayla Fischler
76ab4e17bf #232 WIP full flow view drawn out 2023-08-13 00:11:58 -04:00
Mikayla Fischler
ac1733c46e #314 20s grace period for coordinator render to finish to prevent timeouts 2023-08-12 15:16:37 -04:00
Mikayla
17731de61b #312 improved reactor peripheral handling 2023-08-11 14:20:13 +00:00
Mikayla Fischler
d85385c1fe #232 continued work on flow monitor, added SPS display 2023-08-10 23:31:38 -04:00
Mikayla Fischler
e0809f52a6 #232 WIP coordinator flow view 2023-08-09 23:26:06 -04:00
Mikayla Fischler
b2c55f9d4b #303 check modem message distance for nil 2023-08-02 10:13:54 -04:00
Mikayla
ba896ea163 Merge pull request #302 from MikaylaFischler/common-cleanup
Common Cleanup
2023-07-30 21:38:18 -04:00
Mikayla Fischler
1a64591256 #282 version the common directory 2023-07-30 20:46:04 -04:00
Mikayla Fischler
9ce75eb4bd #283 common cleanup, added lockbox version to crash dump, changed crash handler to pcall requires for graphics/lockbox 2023-07-30 12:24:54 -04:00
Mikayla
451f804f87 Merge pull request #301 from MikaylaFischler/rtu-speaker-system
RTU Speaker System and Pocket Diagnostics
2023-07-30 00:14:49 -04:00
Mikayla Fischler
724d13510d optimizations and cleanup for pull request 2023-07-30 00:13:26 -04:00
Mikayla Fischler
3f01ce7ec5 lowered SVS queue process time limit warning to debug level 2023-07-29 18:44:17 -04:00
Mikayla Fischler
df67795239 #290 pocket page management and alarm test tool, supervisor pocket diagnostics system 2023-07-29 18:16:59 -04:00
Mikayla Fischler
775d4dc95b #264 improvements to RTU speaker sounder 2023-07-29 17:57:51 -04:00
Mikayla Fischler
b3c7263bc4 #299 fixed mouse events passing to hidden elements 2023-07-29 00:25:20 -04:00
Mikayla Fischler
9f8732830c #264, #280 fixed sounder issues 2023-07-26 22:37:25 -04:00
Mikayla Fischler
1c87ef18a1 #297 added tone packet to valid MGMT packet types 2023-07-26 21:33:43 -04:00
Mikayla Fischler
f111b711c5 #264, #280 send tones to RTUs 2023-07-26 21:02:34 -04:00
Mikayla Fischler
92d1945bea #264 WIP RTU alarm sounders 2023-07-26 20:48:44 -04:00
Mikayla Fischler
4192ea426c #280 moved alarm sounder logic to supervisor and tone control to common 2023-07-26 20:48:11 -04:00
Mikayla
7bd8f34773 update README.md 2023-07-19 20:06:13 -04:00
Mikayla
bdbb3071b3 Merge pull request #294 from MikaylaFischler/devel
2023.07.19 Hotfix
2023-07-19 19:18:48 -04:00
Mikayla Fischler
def02a94d2 #293 fixed race condition with graphics element IDs 2023-07-19 11:27:33 -04:00
Mikayla Fischler
681bb0963e #291 RTU comms thread no longer yields every packet 2023-07-18 22:28:43 -04:00
Mikayla
8f7d7c3ead Merge pull request #288 from MikaylaFischler/devel
2023.07.17 Hotfix
2023-07-17 22:48:03 -04:00
Mikayla Fischler
c0f45cfb8b updated comments 2023-07-17 22:47:19 -04:00
Mikayla Fischler
455653074a #287 fixed coordinator not notifying supervisor of auto waste config 2023-07-17 22:09:21 -04:00
Mikayla Fischler
1202289fab #285 #286 mitigated false trips 2023-07-17 20:59:45 -04:00
63 changed files with 3122 additions and 1140 deletions

View File

@@ -18,6 +18,8 @@ Configurable ComputerCraft SCADA system for multi-reactor control of Mekanism fi
![Bootloader](https://img.shields.io/endpoint?url=https%3A%2F%2Fmikaylafischler.github.io%2Fcc-mek-scada%2Fbootloader.json)
![Comms](https://img.shields.io/endpoint?url=https%3A%2F%2Fmikaylafischler.github.io%2Fcc-mek-scada%2Fcomms.json)
![Graphics](https://img.shields.io/endpoint?url=https%3A%2F%2Fmikaylafischler.github.io%2Fcc-mek-scada%2Fgraphics.json)
![Lockbox](https://img.shields.io/endpoint?url=https%3A%2F%2Fmikaylafischler.github.io%2Fcc-mek-scada%2Flockbox.json)
![Reactor PLC](https://img.shields.io/endpoint?url=https%3A%2F%2Fmikaylafischler.github.io%2Fcc-mek-scada%2Freactor-plc.json)

127
ccmsi.lua
View File

@@ -1,8 +1,6 @@
--
-- ComputerCraft Mekanism SCADA System Installer Utility
--
--[[
CC-MEK-SCADA Installer Utility
Copyright (c) 2023 Mikayla Fischler
Permission is hereby granted, free of charge, to any person obtaining a copy of this software and
@@ -20,7 +18,7 @@ SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE.
local function println(message) print(tostring(message)) end
local function print(message) term.write(tostring(message)) end
local CCMSI_VERSION = "v1.7d"
local CCMSI_VERSION = "v1.9"
local install_dir = "/.install-cache"
local manifest_path = "https://mikaylafischler.github.io/cc-mek-scada/manifests/"
@@ -63,16 +61,15 @@ end
local function pkg_message(message, package) white();print(message .. " ");blue();println(package);white() end
-- indicate actions to be taken based on package differences for installs/updates
local function show_pkg_change(name, v_local, v_remote)
if v_local ~= nil then
if v_local ~= v_remote then
print("[" .. name .. "] updating ");blue();print(v_local);white();print(" \xbb ");blue();println(v_remote);white()
local function show_pkg_change(name, v)
if v.v_local ~= nil then
if v.v_local ~= v.v_remote then
print("[" .. name .. "] updating ");blue();print(v.v_local);white();print(" \xbb ");blue();println(v.v_remote);white()
elseif mode == "install" then
pkg_message("[" .. name .. "] reinstalling", v_local)
pkg_message("[" .. name .. "] reinstalling", v.v_local)
end
else
pkg_message("[" .. name .. "] new install of", v_remote)
end
else pkg_message("[" .. name .. "] new install of", v.v_remote) end
return v.v_local ~= v.v_remote
end
-- read the local manifest file
@@ -91,7 +88,7 @@ end
local function get_remote_manifest()
local response, error = http.get(install_manifest)
if response == nil then
orange();println("failed to get installation manifest from GitHub, cannot update or install")
orange();println("Failed to get installation manifest from GitHub, cannot update or install.")
red();println("HTTP error: " .. error);white()
return false, {}
end
@@ -216,8 +213,8 @@ if #opts == 0 or opts[1] == "help" then
println(" supervisor - supervisor server application")
println(" coordinator - coordinator application")
println(" pocket - pocket application")
white();println("<branch>");yellow()
println(" second parameter when used with check")
println(" installer - ccmsi installer (update only)")
white();println("<branch>")
lgray();println(" main (default) | latest | devel");white()
return
else
@@ -227,10 +224,13 @@ else
return
end
app = get_opt(opts[2], { "reactor-plc", "rtu", "supervisor", "coordinator", "pocket" })
app = get_opt(opts[2], { "reactor-plc", "rtu", "supervisor", "coordinator", "pocket", "installer" })
if app == nil and mode ~= "check" then
red();println("Unrecognized application.");white()
return
elseif app == "installer" and mode ~= "update" then
red();println("Installer app only supports 'update' option.");white()
return
end
-- determine target
@@ -276,7 +276,12 @@ if mode == "check" then
print(value);white();println(")")
end
end
if manifest.versions.installer ~= local_manifest.versions.installer then
yellow();println("\nA newer version of the installer is available, it is recommended to update (use 'ccmsi update installer').");white()
end
elseif mode == "install" or mode == "update" then
local update_installer = app == "installer"
local ok, manifest = get_remote_manifest()
if not ok then return end
@@ -284,38 +289,60 @@ elseif mode == "install" or mode == "update" then
app = { v_local = nil, v_remote = nil, changed = false },
boot = { v_local = nil, v_remote = nil, changed = false },
comms = { v_local = nil, v_remote = nil, changed = false },
common = { v_local = nil, v_remote = nil, changed = false },
graphics = { v_local = nil, v_remote = nil, changed = false },
lockbox = { v_local = nil, v_remote = nil, changed = false }
}
-- try to find local versions
local local_ok, local_manifest = read_local_manifest()
local local_ok, lmnf = read_local_manifest()
if not local_ok then
if mode == "update" then
red();println("failed to load local installation information, cannot update");white()
red();println("Failed to load local installation information, cannot update.");white()
return
end
else
ver.boot.v_local = local_manifest.versions.bootloader
ver.app.v_local = local_manifest.versions[app]
ver.comms.v_local = local_manifest.versions.comms
ver.graphics.v_local = local_manifest.versions.graphics
ver.lockbox.v_local = local_manifest.versions.lockbox
elseif not update_installer then
ver.boot.v_local = lmnf.versions.bootloader
ver.app.v_local = lmnf.versions[app]
ver.comms.v_local = lmnf.versions.comms
ver.common.v_local = lmnf.versions.common
ver.graphics.v_local = lmnf.versions.graphics
ver.lockbox.v_local = lmnf.versions.lockbox
if local_manifest.versions[app] == nil then
red();println("another application is already installed, please purge it before installing a new application");white()
if lmnf.versions[app] == nil then
red();println("Another application is already installed, please purge it before installing a new application.");white()
return
end
end
local_manifest.versions.installer = CCMSI_VERSION
if manifest.versions.installer ~= CCMSI_VERSION then
yellow();println("a newer version of the installer is available, it is recommended to download it");white()
lmnf.versions.installer = CCMSI_VERSION
if manifest.versions.installer ~= CCMSI_VERSION then
if not update_installer then yellow();println("A newer version of the installer is available, it is recommended to update to it.");white() end
if update_installer or ask_y_n("Would you like to update now") then
lgray();println("GET ccmsi.lua")
local dl, err = http.get(repo_path .. "ccmsi.lua")
if dl == nil then
red();println("HTTP Error " .. err)
println("Installer download failed.");white()
else
local handle = fs.open(debug.getinfo(1, "S").source:sub(2), "w") -- this file, regardless of name or location
handle.write(dl.readAll())
handle.close()
green();println("Installer updated successfully.");white()
end
return
end
elseif update_installer then
green();println("Installer already up-to-date.");white()
return
end
ver.boot.v_remote = manifest.versions.bootloader
ver.app.v_remote = manifest.versions[app]
ver.comms.v_remote = manifest.versions.comms
ver.common.v_remote = manifest.versions.common
ver.graphics.v_remote = manifest.versions.graphics
ver.lockbox.v_remote = manifest.versions.lockbox
@@ -327,28 +354,15 @@ elseif mode == "install" or mode == "update" then
end
white()
-- display bootloader version change information
show_pkg_change("bootldr", ver.boot.v_local, ver.boot.v_remote)
ver.boot.changed = ver.boot.v_local ~= ver.boot.v_remote
-- display app version change information
show_pkg_change(app, ver.app.v_local, ver.app.v_remote)
ver.app.changed = ver.app.v_local ~= ver.app.v_remote
-- display comms version change information
show_pkg_change("comms", ver.comms.v_local, ver.comms.v_remote)
ver.comms.changed = ver.comms.v_local ~= ver.comms.v_remote
ver.boot.changed = show_pkg_change("bootldr", ver.boot)
ver.common.changed = show_pkg_change("common", ver.common)
ver.comms.changed = show_pkg_change("comms", ver.comms)
if ver.comms.changed and ver.comms.v_local ~= nil then
print("[comms] ");yellow();println("other devices on the network will require an update");white()
end
-- display graphics version change information
show_pkg_change("graphics", ver.graphics.v_local, ver.graphics.v_remote)
ver.graphics.changed = ver.graphics.v_local ~= ver.graphics.v_remote
-- display lockbox version change information
show_pkg_change("lockbox", ver.lockbox.v_local, ver.lockbox.v_remote)
ver.lockbox.changed = ver.lockbox.v_local ~= ver.lockbox.v_remote
ver.app.changed = show_pkg_change(app, ver.app)
ver.graphics.changed = show_pkg_change("graphics", ver.graphics)
ver.lockbox.changed = show_pkg_change("lockbox", ver.lockbox)
-- ask for confirmation
if not ask_y_n("Continue", false) then return end
@@ -379,7 +393,7 @@ elseif mode == "install" or mode == "update" then
yellow();println("WARNING: Insufficient space available for a full download!");white()
println("Files can be downloaded one by one, so if you are replacing a current install this will not be a problem unless installation fails.")
if mode == "update" then println("If installation still fails, delete this device's log file or uninstall the app (not purge) and try again.") end
if not ask_y_n("Do you wish to continue?", false) then
if not ask_y_n("Do you wish to continue", false) then
println("Operation cancelled.")
return
end
@@ -392,16 +406,13 @@ elseif mode == "install" or mode == "update" then
if dependency == "system" then return not ver.boot.changed
elseif dependency == "graphics" then return not ver.graphics.changed
elseif dependency == "lockbox" then return not ver.lockbox.changed
elseif dependency == "common" then return not (ver.app.changed or ver.comms.changed)
elseif dependency == "common" then return not (ver.common.changed or ver.comms.changed)
elseif dependency == app then return not ver.app.changed
else return true end
end
if not single_file_mode then
if fs.exists(install_dir) then
fs.delete(install_dir)
fs.makeDir(install_dir)
end
if fs.exists(install_dir) then fs.delete(install_dir);fs.makeDir(install_dir) end
-- download all dependencies
for _, dependency in pairs(dependencies) do
@@ -417,7 +428,7 @@ elseif mode == "install" or mode == "update" then
local dl, err = http.get(repo_path .. file)
if dl == nil then
red();println("GET HTTP Error " .. err)
red();println("HTTP Error " .. err)
success = false
break
else
@@ -482,7 +493,7 @@ elseif mode == "install" or mode == "update" then
local dl, err = http.get(repo_path .. file)
if dl == nil then
red();println("GET HTTP Error " .. err)
red();println("HTTP Error " .. err)
success = false
break
else
@@ -552,7 +563,7 @@ elseif mode == "remove" or mode == "purge" then
end)
if not log_deleted then
red();println("failed to delete log file")
red();println("Failed to delete log file.")
white();println("press any key to continue...")
any_key();lgray()
end

View File

@@ -26,6 +26,9 @@ config.SOUNDER_VOLUME = 1.0
-- true for 24 hour time on main view screen
config.TIME_24_HOUR = true
-- disable flow view (for legacy layouts)
config.DISABLE_FLOW_VIEW = false
-- log path
config.LOG_PATH = "/log.txt"
-- log mode

View File

@@ -49,12 +49,15 @@ end
-- configure monitor layout
---@param num_units integer number of units expected
---@param disable_flow_view boolean disable flow view (legacy)
---@return boolean success, monitors_struct? monitors
function coordinator.configure_monitors(num_units)
function coordinator.configure_monitors(num_units, disable_flow_view)
---@class monitors_struct
local monitors = {
primary = nil,
primary_name = "",
flow = nil,
flow_name = "",
unit_displays = {},
unit_name_map = {}
}
@@ -69,8 +72,8 @@ function coordinator.configure_monitors(num_units)
table.insert(available, iface)
end
-- we need a certain number of monitors (1 per unit + 1 primary display)
local num_displays_needed = num_units + 1
-- we need a certain number of monitors (1 per unit + 1 primary display + 1 flow display)
local num_displays_needed = num_units + util.trinary(disable_flow_view, 1, 2)
if #names < num_displays_needed then
local message = "not enough monitors connected (need " .. num_displays_needed .. ")"
println(message)
@@ -83,10 +86,12 @@ function coordinator.configure_monitors(num_units)
log.warning("configure_monitors(): failed to load coordinator settings file (may not exist yet)")
else
local _primary = settings.get("PRIMARY_DISPLAY")
local _flow = settings.get("FLOW_DISPLAY")
local _unitd = settings.get("UNIT_DISPLAYS")
-- filter out already assigned monitors
util.filter_table(available, function (x) return x ~= _primary end)
util.filter_table(available, function (x) return x ~= _flow end)
if type(_unitd) == "table" then
util.filter_table(available, function (x) return not util.table_contains(_unitd, x) end)
end
@@ -106,7 +111,6 @@ function coordinator.configure_monitors(num_units)
end
while iface_primary_display == nil and #available > 0 do
-- lets get a monitor
iface_primary_display = ask_monitor(available)
end
@@ -118,6 +122,33 @@ function coordinator.configure_monitors(num_units)
monitors.primary = ppm.get_periph(iface_primary_display)
monitors.primary_name = iface_primary_display
--------------------------
-- FLOW MONITOR DISPLAY --
--------------------------
if not disable_flow_view then
local iface_flow_display = settings.get("FLOW_DISPLAY") ---@type boolean|string|nil
if not util.table_contains(names, iface_flow_display) then
println("flow monitor display is not connected")
local response = dialog.ask_y_n("would you like to change it", true)
if response == false then return false end
iface_flow_display = nil
end
while iface_flow_display == nil and #available > 0 do
iface_flow_display = ask_monitor(available)
end
if type(iface_flow_display) ~= "string" then return false end
settings.set("FLOW_DISPLAY", iface_flow_display)
util.filter_table(available, function (x) return x ~= iface_flow_display end)
monitors.flow = ppm.get_periph(iface_flow_display)
monitors.flow_name = iface_flow_display
end
-------------------
-- UNIT DISPLAYS --
-------------------
@@ -130,7 +161,6 @@ function coordinator.configure_monitors(num_units)
local display = nil
while display == nil and #available > 0 do
-- lets get a monitor
println("please select monitor for unit #" .. i)
display = ask_monitor(available)
end
@@ -152,7 +182,6 @@ function coordinator.configure_monitors(num_units)
end
while display == nil and #available > 0 do
-- lets get a monitor
display = ask_monitor(available)
end
@@ -217,12 +246,13 @@ end
---@nodiscard
---@param version string coordinator version
---@param nic nic network interface device
---@param num_units integer number of configured units for number of monitors, checked against SV
---@param crd_channel integer port of configured supervisor
---@param svr_channel integer listening port for supervisor replys
---@param pkt_channel integer listening port for pocket API
---@param range integer trusted device connection range
---@param sv_watchdog watchdog
function coordinator.comms(version, nic, crd_channel, svr_channel, pkt_channel, range, sv_watchdog)
function coordinator.comms(version, nic, num_units, crd_channel, svr_channel, pkt_channel, range, sv_watchdog)
local self = {
sv_linked = false,
sv_addr = comms.BROADCAST,
@@ -681,21 +711,16 @@ function coordinator.comms(version, nic, crd_channel, svr_channel, pkt_channel,
-- reset to disconnected before validating
iocontrol.fp_link_state(types.PANEL_LINK_STATE.DISCONNECTED)
if type(config) == "table" and #config > 1 then
if type(config) == "table" and #config == 2 then
-- get configuration
---@class facility_conf
local conf = {
num_units = config[1], ---@type integer
defs = {} -- boilers and turbines
cooling = config[2] ---@type sv_cooling_conf
}
if (#config - 1) == (conf.num_units * 2) then
-- record sequence of pairs of [#boilers, #turbines] per unit
for i = 2, #config do
table.insert(conf.defs, config[i])
end
if conf.num_units == num_units then
-- init io controller
iocontrol.init(conf, public)
@@ -707,7 +732,7 @@ function coordinator.comms(version, nic, crd_channel, svr_channel, pkt_channel,
iocontrol.fp_link_state(types.PANEL_LINK_STATE.LINKED)
else
self.sv_config_err = true
log.warning("invalid supervisor configuration definitions received, establish failed")
log.warning("supervisor config's number of units don't match coordinator's config, establish failed")
end
else
log.debug("invalid supervisor configuration table received, establish failed")

View File

@@ -38,9 +38,7 @@ local function __generic_ack(success) end
---@param comms_v string comms version
function iocontrol.init_fp(firmware_v, comms_v)
---@class ioctl_front_panel
io.fp = {
ps = psil.create()
}
io.fp = { ps = psil.create() }
io.fp.ps.publish("version", firmware_v)
io.fp.ps.publish("comms_version", comms_v)
@@ -50,9 +48,12 @@ end
---@param conf facility_conf configuration
---@param comms coord_comms comms reference
function iocontrol.init(conf, comms)
-- facility data structure
---@class ioctl_facility
io.facility = {
num_units = conf.num_units, ---@type integer
num_units = conf.num_units,
tank_mode = conf.cooling.fac_tank_mode,
tank_defs = conf.cooling.fac_tank_defs,
all_sys_ok = false,
rtu_count = 0,
@@ -83,6 +84,8 @@ function iocontrol.init(conf, comms)
scram_ack = __generic_ack,
ack_alarms_ack = __generic_ack,
alarm_tones = { false, false, false, false, false, false, false, false },
ps = psil.create(),
induction_ps_tbl = {},
@@ -104,6 +107,101 @@ function iocontrol.init(conf, comms)
table.insert(io.facility.sps_ps_tbl, psil.create())
table.insert(io.facility.sps_data_tbl, {})
-- determine tank information
if io.facility.tank_mode == 0 then
io.facility.tank_defs = {}
-- on facility tank mode 0, setup tank defs to match unit TANK option
for i = 1, conf.num_units do
io.facility.tank_defs[i] = util.trinary(conf.cooling.r_cool[i].TANK, 1, 0)
end
io.facility.tank_list = { table.unpack(io.facility.tank_defs) }
else
-- decode the layout of tanks from the connections definitions
local tank_mode = io.facility.tank_mode
local tank_defs = io.facility.tank_defs
local tank_list = { table.unpack(tank_defs) }
local function calc_fdef(start_idx, end_idx)
local first = 4
for i = start_idx, end_idx do
if io.facility.tank_defs[i] == 2 then
if i < first then first = i end
end
end
return first
end
if tank_mode == 1 then
-- (1) 1 total facility tank (A A A A)
local first_fdef = calc_fdef(1, #tank_defs)
for i = 1, #tank_defs do
if i > first_fdef and tank_defs[i] == 2 then
tank_list[i] = 0
end
end
elseif tank_mode == 2 then
-- (2) 2 total facility tanks (A A A B)
local first_fdef = calc_fdef(1, math.min(3, #tank_defs))
for i = 1, #tank_defs do
if (i ~= 4) and (i > first_fdef) and (tank_defs[i] == 2) then
tank_list[i] = 0
end
end
elseif tank_mode == 3 then
-- (3) 2 total facility tanks (A A B B)
for _, a in pairs({ 1, 3 }) do
local b = a + 1
if (tank_defs[a] == 2) and (tank_defs[b] == 2) then
tank_list[b] = 0
end
end
elseif tank_mode == 4 then
-- (4) 2 total facility tanks (A B B B)
local first_fdef = calc_fdef(2, #tank_defs)
for i = 1, #tank_defs do
if (i ~= 1) and (i > first_fdef) and (tank_defs[i] == 2) then
tank_list[i] = 0
end
end
elseif tank_mode == 5 then
-- (5) 3 total facility tanks (A A B C)
local first_fdef = calc_fdef(1, math.min(2, #tank_defs))
for i = 1, #tank_defs do
if (not (i == 3 or i == 4)) and (i > first_fdef) and (tank_defs[i] == 2) then
tank_list[i] = 0
end
end
elseif tank_mode == 6 then
-- (6) 3 total facility tanks (A B B C)
local first_fdef = calc_fdef(2, math.min(3, #tank_defs))
for i = 1, #tank_defs do
if (not (i == 1 or i == 4)) and (i > first_fdef) and (tank_defs[i] == 2) then
tank_list[i] = 0
end
end
elseif tank_mode == 7 then
-- (7) 3 total facility tanks (A B C C)
local first_fdef = calc_fdef(3, #tank_defs)
for i = 1, #tank_defs do
if (not (i == 1 or i == 2)) and (i > first_fdef) and (tank_defs[i] == 2) then
tank_list[i] = 0
end
end
end
io.facility.tank_list = tank_list
end
-- create facility tank tables
for i = 1, #io.facility.tank_list do
if io.facility.tank_list[i] == 2 then
table.insert(io.facility.tank_ps_tbl, psil.create())
table.insert(io.facility.tank_data_tbl, {})
end
end
-- create unit data structures
io.units = {}
for i = 1, conf.num_units do
local function ack(alarm) process.ack_alarm(i, alarm) end
@@ -116,6 +214,7 @@ function iocontrol.init(conf, comms)
num_boilers = 0,
num_turbines = 0,
num_snas = 0,
has_tank = conf.cooling.r_cool[i].TANK,
control_state = false,
burn_rate_cmd = 0.0,
@@ -190,18 +289,27 @@ function iocontrol.init(conf, comms)
tank_data_tbl = {}
}
-- on other facility modes, overwrite unit TANK option with facility tank defs
if io.facility.tank_mode ~= 0 then
entry.has_tank = conf.cooling.fac_tank_defs[i] > 0
end
-- create boiler tables
for _ = 1, conf.defs[(i * 2) - 1] do
local data = {} ---@type boilerv_session_db
for _ = 1, conf.cooling.r_cool[i].BOILERS do
table.insert(entry.boiler_ps_tbl, psil.create())
table.insert(entry.boiler_data_tbl, data)
table.insert(entry.boiler_data_tbl, {})
end
-- create turbine tables
for _ = 1, conf.defs[i * 2] do
local data = {} ---@type turbinev_session_db
for _ = 1, conf.cooling.r_cool[i].TURBINES do
table.insert(entry.turbine_ps_tbl, psil.create())
table.insert(entry.turbine_data_tbl, data)
table.insert(entry.turbine_data_tbl, {})
end
-- create tank tables
if io.facility.tank_defs[i] == 1 then
table.insert(entry.tank_ps_tbl, psil.create())
table.insert(entry.tank_data_tbl, {})
end
entry.num_boilers = #entry.boiler_data_tbl
@@ -232,11 +340,21 @@ function iocontrol.fp_has_speaker(has_speaker) io.fp.ps.publish("has_speaker", h
function iocontrol.fp_link_state(state) io.fp.ps.publish("link_state", state) end
-- report monitor connection state
---@param id integer unit ID or 0 for main
---@param id string|integer unit ID for unit monitor, "main" for main monitor, or "flow" for flow monitor
function iocontrol.fp_monitor_state(id, connected)
local name = "main_monitor"
if id > 0 then name = "unit_monitor_" .. id end
io.fp.ps.publish(name, connected)
local name = nil
if id == "main" then
name = "main_monitor"
elseif id == "flow" then
name = "flow_monitor"
elseif type(id) == "number" then
name = "unit_monitor_" .. id
end
if name ~= nil then
io.fp.ps.publish(name, connected)
end
end
-- report PKT firmware version and PKT session connection state
@@ -664,6 +782,16 @@ function iocontrol.update_facility_status(status)
end
fac.ps.publish("rtu_count", fac.rtu_count)
-- alarm tone commands
if (type(status[3]) == "table") and (#status[3] == 8) then
fac.alarm_tones = status[3]
sounder.set(fac.alarm_tones)
else
log.debug(log_header .. "alarm tones not a table or length mismatch")
valid = false
end
end
return valid
@@ -684,8 +812,7 @@ function iocontrol.update_unit_statuses(statuses)
else
local burn_rate_sum = 0.0
local sna_count_sum = 0
local pu_rate = 0.0
local po_rate = 0.0
local pu_rate, po_rate, po_pl_rate, po_am_rate, spent_rate = 0.0, 0.0, 0.0, 0.0, 0.0
-- get all unit statuses
for i = 1, #statuses do
@@ -696,7 +823,7 @@ function iocontrol.update_unit_statuses(statuses)
local burn_rate = 0.0
if type(status) ~= "table" or #status ~= 5 then
if type(status) ~= "table" or #status ~= 6 then
log.debug(log_header .. "invalid status entry in unit statuses (not a table or invalid length)")
valid = false
else
@@ -779,6 +906,8 @@ function iocontrol.update_unit_statuses(statuses)
if type(rtu_statuses) == "table" then
-- boiler statuses
if type(rtu_statuses.boilers) == "table" then
local boil_sum = 0
for id = 1, #unit.boiler_ps_tbl do
if rtu_statuses.boilers[i] == nil then
-- disconnected
@@ -796,6 +925,8 @@ function iocontrol.update_unit_statuses(statuses)
if rtu_faulted then
ps.publish("computed_status", 3) -- faulted
elseif data.formed then
boil_sum = boil_sum + data.state.boil_rate
if data.state.boil_rate > 0 then
ps.publish("computed_status", 5) -- active
else
@@ -809,6 +940,8 @@ function iocontrol.update_unit_statuses(statuses)
valid = false
end
end
unit.unit_ps.publish("boiler_boil_sum", boil_sum)
else
log.debug(log_header .. "boiler list not a table")
valid = false
@@ -816,6 +949,8 @@ function iocontrol.update_unit_statuses(statuses)
-- turbine statuses
if type(rtu_statuses.turbines) == "table" then
local flow_sum = 0
for id = 1, #unit.turbine_ps_tbl do
if rtu_statuses.turbines[i] == nil then
-- disconnected
@@ -833,6 +968,8 @@ function iocontrol.update_unit_statuses(statuses)
if rtu_faulted then
ps.publish("computed_status", 3) -- faulted
elseif data.formed then
flow_sum = flow_sum + data.state.flow_rate
if data.tanks.energy_fill >= 0.99 then
ps.publish("computed_status", 6) -- trip
elseif data.state.flow_rate < 100 then
@@ -848,6 +985,8 @@ function iocontrol.update_unit_statuses(statuses)
valid = false
end
end
unit.unit_ps.publish("turbine_flow_sum", flow_sum)
else
log.debug(log_header .. "turbine list not a table")
valid = false
@@ -877,7 +1016,7 @@ function iocontrol.update_unit_statuses(statuses)
elseif data.tanks.fill < 0.20 then
ps.publish("computed_status", 5) -- low
else
ps.publish("computed_status", 5) -- active
ps.publish("computed_status", 4) -- on-line
end
else
ps.publish("computed_status", 2) -- not formed
@@ -896,8 +1035,11 @@ function iocontrol.update_unit_statuses(statuses)
if type(rtu_statuses.sna) == "table" then
unit.num_snas = rtu_statuses.sna[1] ---@type integer
unit.sna_prod_rate = rtu_statuses.sna[2] ---@type number
unit.sna_peak_rate = rtu_statuses.sna[3] ---@type number
unit.unit_ps.publish("sna_count", unit.num_snas)
unit.unit_ps.publish("sna_prod_rate", unit.sna_prod_rate)
unit.unit_ps.publish("sna_peak_rate", unit.sna_peak_rate)
sna_count_sum = sna_count_sum + unit.num_snas
else
@@ -1002,10 +1144,63 @@ function iocontrol.update_unit_statuses(statuses)
valid = false
end
-- valve states
local valve_states = status[6]
if type(valve_states) == "table" then
if #valve_states == 5 then
unit.unit_ps.publish("V_pu_conn", valve_states[1] > 0)
unit.unit_ps.publish("V_pu_state", valve_states[1] == 2)
unit.unit_ps.publish("V_po_conn", valve_states[2] > 0)
unit.unit_ps.publish("V_po_state", valve_states[2] == 2)
unit.unit_ps.publish("V_pl_conn", valve_states[3] > 0)
unit.unit_ps.publish("V_pl_state", valve_states[3] == 2)
unit.unit_ps.publish("V_am_conn", valve_states[4] > 0)
unit.unit_ps.publish("V_am_state", valve_states[4] == 2)
unit.unit_ps.publish("V_emc_conn", valve_states[5] > 0)
unit.unit_ps.publish("V_emc_state", valve_states[5] == 2)
else
log.debug(log_header .. "valve states length mismatch")
valid = false
end
else
log.debug(log_header .. "valve states not a table")
valid = false
end
-- determine waste production for this unit, add to statistics
local is_pu = unit.waste_product == types.WASTE_PRODUCT.PLUTONIUM
pu_rate = pu_rate + util.trinary(is_pu, burn_rate / 10.0, 0.0)
po_rate = po_rate + util.trinary(not is_pu, math.min(burn_rate / 10.0, unit.sna_prod_rate), 0.0)
local waste_rate = burn_rate / 10.0
local u_spent_rate = waste_rate
local u_pu_rate = util.trinary(is_pu, waste_rate, 0.0)
local u_po_rate = util.trinary(not is_pu, math.min(waste_rate, unit.sna_prod_rate), 0.0)
unit.unit_ps.publish("pu_rate", u_pu_rate)
unit.unit_ps.publish("po_rate", u_po_rate)
unit.unit_ps.publish("sna_in", util.trinary(is_pu, 0, burn_rate))
if unit.waste_product == types.WASTE_PRODUCT.POLONIUM then
unit.unit_ps.publish("po_pl_rate", u_po_rate)
unit.unit_ps.publish("po_am_rate", 0)
po_pl_rate = po_pl_rate + u_po_rate
elseif unit.waste_product == types.WASTE_PRODUCT.ANTI_MATTER then
unit.unit_ps.publish("po_pl_rate", 0)
unit.unit_ps.publish("po_am_rate", u_po_rate)
po_am_rate = po_am_rate + u_po_rate
u_spent_rate = 0
else
unit.unit_ps.publish("po_pl_rate", 0)
unit.unit_ps.publish("po_am_rate", 0)
end
unit.unit_ps.publish("ws_rate", u_spent_rate)
pu_rate = pu_rate + u_pu_rate
po_rate = po_rate + u_po_rate
spent_rate = spent_rate + u_spent_rate
end
end
@@ -1013,9 +1208,9 @@ function iocontrol.update_unit_statuses(statuses)
io.facility.ps.publish("sna_count", sna_count_sum)
io.facility.ps.publish("pu_rate", pu_rate)
io.facility.ps.publish("po_rate", po_rate)
-- update alarm sounder
sounder.eval(io.units)
io.facility.ps.publish("po_pl_rate", po_pl_rate)
io.facility.ps.publish("po_am_rate", po_am_rate)
io.facility.ps.publish("spent_waste_rate", spent_rate)
end
return valid

View File

@@ -75,6 +75,10 @@ function process.init(iocontrol, coord_comms)
end
log.info("PROCESS: loaded auto control settings from coord.settings")
-- notify supervisor of auto waste config
self.comms.send_fac_command(FAC_COMMAND.SET_WASTE_MODE, self.config.waste_product)
self.comms.send_fac_command(FAC_COMMAND.SET_PU_FB, self.config.pu_fallback)
end
-- unit waste states

View File

@@ -10,6 +10,7 @@ local iocontrol = require("coordinator.iocontrol")
local style = require("coordinator.ui.style")
local pgi = require("coordinator.ui.pgi")
local flow_view = require("coordinator.ui.layout.flow_view")
local panel_view = require("coordinator.ui.layout.front_panel")
local main_view = require("coordinator.ui.layout.main_view")
local unit_view = require("coordinator.ui.layout.unit_view")
@@ -29,8 +30,10 @@ local engine = {
ui = {
front_panel = nil, ---@type graphics_element|nil
main_display = nil, ---@type graphics_element|nil
flow_display = nil, ---@type graphics_element|nil
unit_displays = {}
}
},
disable_flow_view = false
}
-- init a display to the "default", but set text scale to 0.5
@@ -48,20 +51,28 @@ local function _init_display(monitor)
end
end
-- disable the flow view
---@param disable boolean
function renderer.legacy_disable_flow_view(disable)
engine.disable_flow_view = disable
end
-- link to the monitor peripherals
---@param monitors monitors_struct
function renderer.set_displays(monitors)
engine.monitors = monitors
-- report to front panel as connected
iocontrol.fp_monitor_state(0, true)
iocontrol.fp_monitor_state("main", engine.monitors.primary ~= nil)
iocontrol.fp_monitor_state("flow", engine.monitors.flow ~= nil)
for i = 1, #engine.monitors.unit_displays do iocontrol.fp_monitor_state(i, true) end
end
-- init all displays in use by the renderer
function renderer.init_displays()
-- init primary monitor
-- init primary and flow monitors
_init_display(engine.monitors.primary)
if not engine.disable_flow_view then _init_display(engine.monitors.flow) end
-- init unit displays
for _, monitor in ipairs(engine.monitors.unit_displays) do
@@ -88,6 +99,14 @@ function renderer.validate_main_display_width()
return w == 164
end
-- check flow display width
---@nodiscard
---@return boolean width_okay
function renderer.validate_flow_display_width()
local w, _ = engine.monitors.flow.getSize()
return w == 164
end
-- check display sizes
---@nodiscard
---@return boolean valid all unit display dimensions OK
@@ -169,6 +188,12 @@ function renderer.start_ui()
main_view(engine.ui.main_display)
end
-- show flow view on flow monitor
if engine.monitors.flow ~= nil then
engine.ui.flow_display = DisplayBox{window=engine.monitors.flow,fg_bg=style.root}
flow_view(engine.ui.flow_display)
end
-- show unit views on unit displays
for idx, display in pairs(engine.monitors.unit_displays) do
engine.ui.unit_displays[idx] = DisplayBox{window=display,fg_bg=style.root}
@@ -192,6 +217,7 @@ function renderer.close_ui()
-- delete element trees
if engine.ui.main_display ~= nil then engine.ui.main_display.delete() end
if engine.ui.flow_display ~= nil then engine.ui.flow_display.delete() end
for _, display in pairs(engine.ui.unit_displays) do display.delete() end
-- report ui as not ready
@@ -199,6 +225,7 @@ function renderer.close_ui()
-- clear root UI elements
engine.ui.main_display = nil
engine.ui.flow_display = nil
engine.ui.unit_displays = {}
-- clear unit monitors
@@ -236,7 +263,18 @@ function renderer.handle_disconnect(device)
engine.monitors.primary = nil
engine.ui.main_display = nil
iocontrol.fp_monitor_state(0, false)
iocontrol.fp_monitor_state("main", false)
elseif engine.monitors.flow == device then
if engine.ui.flow_display ~= nil then
-- delete element tree and clear root UI elements
engine.ui.flow_display.delete()
end
is_used = true
engine.monitors.flow = nil
engine.ui.flow_display = nil
iocontrol.fp_monitor_state("flow", false)
else
for idx, monitor in pairs(engine.monitors.unit_displays) do
if monitor == device then
@@ -284,7 +322,18 @@ function renderer.handle_reconnect(name, device)
engine.dmesg_window.redraw()
end
iocontrol.fp_monitor_state(0, true)
iocontrol.fp_monitor_state("main", true)
elseif engine.monitors.flow_name == name then
is_used = true
_init_display(device)
engine.monitors.flow = device
if engine.ui_ready and (engine.ui.flow_display == nil) then
engine.ui.flow_display = DisplayBox{window=device,fg_bg=style.root}
flow_view(engine.ui.flow_display)
end
iocontrol.fp_monitor_state("flow", true)
else
for idx, monitor in ipairs(engine.monitors.unit_name_map) do
if monitor == name then
@@ -317,6 +366,8 @@ function renderer.handle_mouse(event)
elseif engine.ui_ready then
if event.monitor == engine.monitors.primary_name then
engine.ui.main_display.handle_mouse(event)
elseif event.monitor == engine.monitors.flow_name then
engine.ui.flow_display.handle_mouse(event)
else
for id, monitor in ipairs(engine.monitors.unit_name_map) do
if event.monitor == monitor then

View File

@@ -2,269 +2,25 @@
-- Alarm Sounder
--
local audio = require("scada-common.audio")
local log = require("scada-common.log")
local types = require("scada-common.types")
local util = require("scada-common.util")
local ALARM = types.ALARM
local ALARM_STATE = types.ALARM_STATE
---@class sounder
local sounder = {}
-- note: max samples = 0x20000 (128 * 1024 samples)
local _2_PI = 2 * math.pi -- 2 whole pies, hope you're hungry
local _DRATE = 48000 -- 48kHz audio
local _MAX_VAL = 127 / 2 -- max signed integer in this 8-bit audio
local _05s_SAMPLES = 24000 -- half a second worth of samples
local test_alarms = { false, false, false, false, false, false, false, false, false, false, false, false }
local alarm_ctl = {
speaker = nil,
volume = 0.5,
playing = false,
num_active = 0,
next_block = 1,
-- split audio up into 0.5s samples so specific components can be ended quicker
quad_buffer = { {}, {}, {}, {} }
stream = audio.new_stream()
}
-- sounds modeled after https://www.e2s.com/references-and-guidelines/listen-and-download-alarm-tones
local T_340Hz_Int_2Hz = 1
local T_544Hz_440Hz_Alt = 2
local T_660Hz_Int_125ms = 3
local T_745Hz_Int_1Hz = 4
local T_800Hz_Int = 5
local T_800Hz_1000Hz_Alt = 6
local T_1000Hz_Int = 7
local T_1800Hz_Int_4Hz = 8
local TONES = {
{ active = false, component = { {}, {}, {}, {} } }, -- 340Hz @ 2Hz Intermittent
{ active = false, component = { {}, {}, {}, {} } }, -- 544Hz 100mS / 440Hz 400mS Alternating
{ active = false, component = { {}, {}, {}, {} } }, -- 660Hz @ 125ms On 125ms Off
{ active = false, component = { {}, {}, {}, {} } }, -- 745Hz @ 1Hz Intermittent
{ active = false, component = { {}, {}, {}, {} } }, -- 800Hz @ 0.25s On 1.75s Off
{ active = false, component = { {}, {}, {}, {} } }, -- 800/1000Hz @ 0.25s Alternating
{ active = false, component = { {}, {}, {}, {} } }, -- 1KHz 1s on, 1s off Intermittent
{ active = false, component = { {}, {}, {}, {} } } -- 1.8KHz @ 4Hz Intermittent
}
-- calculate how many samples are in the given number of milliseconds
---@nodiscard
---@param ms integer milliseconds
---@return integer samples
local function ms_to_samples(ms) return math.floor(ms * 48) end
--#region Tone Generation (the Maths)
-- 340Hz @ 2Hz Intermittent
local function gen_tone_1()
local t, dt = 0, _2_PI * 340 / _DRATE
for i = 1, _05s_SAMPLES do
local val = math.floor(math.sin(t) * _MAX_VAL)
TONES[1].component[1][i] = val
TONES[1].component[3][i] = val
TONES[1].component[2][i] = 0
TONES[1].component[4][i] = 0
t = (t + dt) % _2_PI
end
end
-- 544Hz 100mS / 440Hz 400mS Alternating
local function gen_tone_2()
local t1, dt1 = 0, _2_PI * 544 / _DRATE
local t2, dt2 = 0, _2_PI * 440 / _DRATE
local alternate_at = ms_to_samples(100)
for i = 1, _05s_SAMPLES do
local value
if i <= alternate_at then
value = math.floor(math.sin(t1) * _MAX_VAL)
t1 = (t1 + dt1) % _2_PI
else
value = math.floor(math.sin(t2) * _MAX_VAL)
t2 = (t2 + dt2) % _2_PI
end
TONES[2].component[1][i] = value
TONES[2].component[2][i] = value
TONES[2].component[3][i] = value
TONES[2].component[4][i] = value
end
end
-- 660Hz @ 125ms On 125ms Off
local function gen_tone_3()
local elapsed_samples = 0
local alternate_after = ms_to_samples(125)
local alternate_at = alternate_after
local mode = true
local t, dt = 0, _2_PI * 660 / _DRATE
for set = 1, 4 do
for i = 1, _05s_SAMPLES do
if mode then
local val = math.floor(math.sin(t) * _MAX_VAL)
TONES[3].component[set][i] = val
t = (t + dt) % _2_PI
else
t = 0
TONES[3].component[set][i] = 0
end
if elapsed_samples == alternate_at then
mode = not mode
alternate_at = elapsed_samples + alternate_after
end
elapsed_samples = elapsed_samples + 1
end
end
end
-- 745Hz @ 1Hz Intermittent
local function gen_tone_4()
local t, dt = 0, _2_PI * 745 / _DRATE
for i = 1, _05s_SAMPLES do
local val = math.floor(math.sin(t) * _MAX_VAL)
TONES[4].component[1][i] = val
TONES[4].component[3][i] = val
TONES[4].component[2][i] = 0
TONES[4].component[4][i] = 0
t = (t + dt) % _2_PI
end
end
-- 800Hz @ 0.25s On 1.75s Off
local function gen_tone_5()
local t, dt = 0, _2_PI * 800 / _DRATE
local stop_at = ms_to_samples(250)
for i = 1, _05s_SAMPLES do
local val = math.floor(math.sin(t) * _MAX_VAL)
if i > stop_at then
TONES[5].component[1][i] = val
else
TONES[5].component[1][i] = 0
end
TONES[5].component[2][i] = 0
TONES[5].component[3][i] = 0
TONES[5].component[4][i] = 0
t = (t + dt) % _2_PI
end
end
-- 1000/800Hz @ 0.25s Alternating
local function gen_tone_6()
local t1, dt1 = 0, _2_PI * 1000 / _DRATE
local t2, dt2 = 0, _2_PI * 800 / _DRATE
local alternate_at = ms_to_samples(250)
for i = 1, _05s_SAMPLES do
local val
if i <= alternate_at then
val = math.floor(math.sin(t1) * _MAX_VAL)
t1 = (t1 + dt1) % _2_PI
else
val = math.floor(math.sin(t2) * _MAX_VAL)
t2 = (t2 + dt2) % _2_PI
end
TONES[6].component[1][i] = val
TONES[6].component[2][i] = val
TONES[6].component[3][i] = val
TONES[6].component[4][i] = val
end
end
-- 1KHz 1s on, 1s off Intermittent
local function gen_tone_7()
local t, dt = 0, _2_PI * 1000 / _DRATE
for i = 1, _05s_SAMPLES do
local val = math.floor(math.sin(t) * _MAX_VAL)
TONES[7].component[1][i] = val
TONES[7].component[2][i] = val
TONES[7].component[3][i] = 0
TONES[7].component[4][i] = 0
t = (t + dt) % _2_PI
end
end
-- 1800Hz @ 4Hz Intermittent
local function gen_tone_8()
local t, dt = 0, _2_PI * 1800 / _DRATE
local off_at = ms_to_samples(250)
for i = 1, _05s_SAMPLES do
local val = 0
if i <= off_at then
val = math.floor(math.sin(t) * _MAX_VAL)
t = (t + dt) % _2_PI
end
TONES[8].component[1][i] = val
TONES[8].component[2][i] = val
TONES[8].component[3][i] = val
TONES[8].component[4][i] = val
end
end
--#endregion
-- hard audio limiter
---@nodiscard
---@param output number output level
---@return number limited -128.0 to 127.0
local function limit(output)
return math.max(-128, math.min(127, output))
end
-- zero the alarm audio buffer
local function zero()
for i = 1, 4 do
for s = 1, _05s_SAMPLES do alarm_ctl.quad_buffer[i][s] = 0 end
end
end
-- add an alarm to the output buffer
---@param alarm_idx integer tone ID
local function add(alarm_idx)
alarm_ctl.num_active = alarm_ctl.num_active + 1
TONES[alarm_idx].active = true
for i = 1, 4 do
for s = 1, _05s_SAMPLES do
alarm_ctl.quad_buffer[i][s] = limit(alarm_ctl.quad_buffer[i][s] + TONES[alarm_idx].component[i][s])
end
end
end
-- start audio or continue audio on buffer empty
---@return boolean success successfully added buffer to audio output
local function play()
if not alarm_ctl.playing then
alarm_ctl.playing = true
alarm_ctl.next_block = 1
return sounder.continue()
else
return true
end
else return true end
end
-- initialize the annunciator alarm system
@@ -273,23 +29,10 @@ end
function sounder.init(speaker, volume)
alarm_ctl.speaker = speaker
alarm_ctl.speaker.stop()
alarm_ctl.volume = volume
alarm_ctl.playing = false
alarm_ctl.num_active = 0
alarm_ctl.next_block = 1
alarm_ctl.stream.stop()
zero()
-- generate tones
gen_tone_1()
gen_tone_2()
gen_tone_3()
gen_tone_4()
gen_tone_5()
gen_tone_6()
gen_tone_7()
gen_tone_8()
audio.generate_tones()
end
-- reconnect the speaker peripheral
@@ -297,173 +40,40 @@ end
function sounder.reconnect(speaker)
alarm_ctl.speaker = speaker
alarm_ctl.playing = false
alarm_ctl.next_block = 1
alarm_ctl.num_active = 0
for id = 1, #TONES do TONES[id].active = false end
alarm_ctl.stream.stop()
end
-- check alarm state to enable/disable alarms
---@param units table|nil unit list or nil to use test mode
function sounder.eval(units)
local changed = false
local any_active = false
local new_states = { false, false, false, false, false, false, false, false }
local alarms = { false, false, false, false, false, false, false, false, false, false, false, false }
-- set alarm tones
---@param states table alarm tone commands from supervisor
function sounder.set(states)
-- set tone states
for id = 1, #states do alarm_ctl.stream.set_active(id, states[id]) end
if units ~= nil then
-- check all alarms for all units
for i = 1, #units do
local unit = units[i] ---@type ioctl_unit
for id = 1, #unit.alarms do
alarms[id] = alarms[id] or (unit.alarms[id] == ALARM_STATE.TRIPPED)
end
end
else
alarms = test_alarms
end
-- containment breach is worst case CRITICAL alarm, this takes priority
if alarms[ALARM.ContainmentBreach] then
new_states[T_1800Hz_Int_4Hz] = true
else
-- critical damage is highest priority CRITICAL level alarm
if alarms[ALARM.CriticalDamage] then
new_states[T_660Hz_Int_125ms] = true
else
-- EMERGENCY level alarms + URGENT over temp
if alarms[ALARM.ReactorDamage] or alarms[ALARM.ReactorOverTemp] or alarms[ALARM.ReactorWasteLeak] then
new_states[T_544Hz_440Hz_Alt] = true
-- URGENT level turbine trip
elseif alarms[ALARM.TurbineTrip] then
new_states[T_745Hz_Int_1Hz] = true
-- URGENT level reactor lost
elseif alarms[ALARM.ReactorLost] then
new_states[T_340Hz_Int_2Hz] = true
-- TIMELY level alarms
elseif alarms[ALARM.ReactorHighTemp] or alarms[ALARM.ReactorHighWaste] or alarms[ALARM.RCSTransient] then
new_states[T_800Hz_Int] = true
end
end
-- check RPS transient URGENT level alarm
if alarms[ALARM.RPSTransient] then
new_states[T_1000Hz_Int] = true
-- disable really painful audio combination
new_states[T_340Hz_Int_2Hz] = false
end
end
-- radiation is a big concern, always play this CRITICAL level alarm if active
if alarms[ALARM.ContainmentRadiation] then
new_states[T_800Hz_1000Hz_Alt] = true
-- we are going to disable the RPS trip alarm audio due to conflict, and if it was enabled
-- then we can re-enable the reactor lost alarm audio since it doesn't painfully combine with this one
if new_states[T_1000Hz_Int] and alarms[ALARM.ReactorLost] then new_states[T_340Hz_Int_2Hz] = true end
-- it sounds *really* bad if this is in conjunction with these other tones, so disable them
new_states[T_745Hz_Int_1Hz] = false
new_states[T_800Hz_Int] = false
new_states[T_1000Hz_Int] = false
end
-- check if any changed, check if any active, update active flags
for id = 1, #TONES do
if new_states[id] ~= TONES[id].active then
TONES[id].active = new_states[id]
changed = true
end
if TONES[id].active then any_active = true end
end
-- zero and re-add tones if changed
if changed then
zero()
for id = 1, #TONES do
if TONES[id].active then add(id) end
end
end
if any_active then play() else sounder.stop() end
-- re-compute output if needed, then play audio if available
if alarm_ctl.stream.is_recompute_needed() then alarm_ctl.stream.compute_buffer() end
if alarm_ctl.stream.has_next_block() then play() else sounder.stop() end
end
-- stop all audio and clear output buffer
function sounder.stop()
alarm_ctl.playing = false
alarm_ctl.speaker.stop()
alarm_ctl.next_block = 1
alarm_ctl.num_active = 0
for id = 1, #TONES do TONES[id].active = false end
zero()
alarm_ctl.stream.stop()
end
-- continue audio on buffer empty
---@return boolean success successfully added buffer to audio output
function sounder.continue()
local success = false
if alarm_ctl.playing then
if alarm_ctl.speaker ~= nil and #alarm_ctl.quad_buffer[alarm_ctl.next_block] > 0 then
local success = alarm_ctl.speaker.playAudio(alarm_ctl.quad_buffer[alarm_ctl.next_block], alarm_ctl.volume)
alarm_ctl.next_block = alarm_ctl.next_block + 1
if alarm_ctl.next_block > 4 then alarm_ctl.next_block = 1 end
if not success then
log.debug("SOUNDER: error playing audio")
end
return success
else
return false
end
else
return false
end
end
--#region Test Functions
function sounder.test_1() add(1) play() end -- play tone T_340Hz_Int_2Hz
function sounder.test_2() add(2) play() end -- play tone T_544Hz_440Hz_Alt
function sounder.test_3() add(3) play() end -- play tone T_660Hz_Int_125ms
function sounder.test_4() add(4) play() end -- play tone T_745Hz_Int_1Hz
function sounder.test_5() add(5) play() end -- play tone T_800Hz_Int
function sounder.test_6() add(6) play() end -- play tone T_800Hz_1000Hz_Alt
function sounder.test_7() add(7) play() end -- play tone T_1000Hz_Int
function sounder.test_8() add(8) play() end -- play tone T_1800Hz_Int_4Hz
function sounder.test_breach(active) test_alarms[ALARM.ContainmentBreach] = active end ---@param active boolean
function sounder.test_rad(active) test_alarms[ALARM.ContainmentRadiation] = active end ---@param active boolean
function sounder.test_lost(active) test_alarms[ALARM.ReactorLost] = active end ---@param active boolean
function sounder.test_crit(active) test_alarms[ALARM.CriticalDamage] = active end ---@param active boolean
function sounder.test_dmg(active) test_alarms[ALARM.ReactorDamage] = active end ---@param active boolean
function sounder.test_overtemp(active) test_alarms[ALARM.ReactorOverTemp] = active end ---@param active boolean
function sounder.test_hightemp(active) test_alarms[ALARM.ReactorHighTemp] = active end ---@param active boolean
function sounder.test_wasteleak(active) test_alarms[ALARM.ReactorWasteLeak] = active end ---@param active boolean
function sounder.test_highwaste(active) test_alarms[ALARM.ReactorHighWaste] = active end ---@param active boolean
function sounder.test_rps(active) test_alarms[ALARM.RPSTransient] = active end ---@param active boolean
function sounder.test_rcs(active) test_alarms[ALARM.RCSTransient] = active end ---@param active boolean
function sounder.test_turbinet(active) test_alarms[ALARM.TurbineTrip] = active end ---@param active boolean
-- power rescaling limiter test
function sounder.test_power_scale()
local start = util.time_ms()
zero()
for id = 1, #TONES do
if TONES[id].active then
for i = 1, 4 do
for s = 1, _05s_SAMPLES do
alarm_ctl.quad_buffer[i][s] = limit(alarm_ctl.quad_buffer[i][s] +
(TONES[id].component[i][s] / math.sqrt(alarm_ctl.num_active)))
end
end
if alarm_ctl.speaker ~= nil and alarm_ctl.stream.has_next_block() then
success = alarm_ctl.speaker.playAudio(alarm_ctl.stream.get_next_block(), alarm_ctl.volume)
if not success then log.error("SOUNDER: error playing audio") end
end
end
log.debug("SOUNDER: power rescale test took " .. (util.time_ms() - start) .. "ms")
return success
end
--#endregion
return sounder

View File

@@ -22,7 +22,7 @@ local sounder = require("coordinator.sounder")
local apisessions = require("coordinator.session.apisessions")
local COORDINATOR_VERSION = "v0.21.0"
local COORDINATOR_VERSION = "v1.0.1"
local println = util.println
local println_ts = util.println_ts
@@ -84,7 +84,7 @@ local function main()
iocontrol.init_fp(COORDINATOR_VERSION, comms.version)
-- setup monitors
local configured, monitors = coordinator.configure_monitors(config.NUM_UNITS)
local configured, monitors = coordinator.configure_monitors(config.NUM_UNITS, config.DISABLE_FLOW_VIEW == true)
if not configured or monitors == nil then
println("startup> monitor setup failed")
log.fatal("monitor configuration failed")
@@ -92,6 +92,7 @@ local function main()
end
-- init renderer
renderer.legacy_disable_flow_view(config.DISABLE_FLOW_VIEW == true)
renderer.set_displays(monitors)
renderer.init_displays()
@@ -99,6 +100,10 @@ local function main()
println("startup> main display must be 8 blocks wide")
log.fatal("main display not wide enough")
return
elseif (config.DISABLE_FLOW_VIEW ~= true) and not renderer.validate_flow_display_width() then
println("startup> flow display must be 8 blocks wide")
log.fatal("flow display not wide enough")
return
elseif not renderer.validate_unit_display_sizes() then
println("startup> one or more unit display dimensions incorrect; they must be 4x4 blocks")
log.fatal("unit display dimensions incorrect")
@@ -162,8 +167,8 @@ local function main()
-- create network interface then setup comms
local nic = network.nic(modem)
local coord_comms = coordinator.comms(COORDINATOR_VERSION, nic, config.CRD_CHANNEL, config.SVR_CHANNEL,
config.PKT_CHANNEL, config.TRUSTED_RANGE, conn_watchdog)
local coord_comms = coordinator.comms(COORDINATOR_VERSION, nic, config.NUM_UNITS, config.CRD_CHANNEL,
config.SVR_CHANNEL, config.PKT_CHANNEL, config.TRUSTED_RANGE, conn_watchdog)
log.debug("startup> comms init")
log_comms("comms initialized")

View File

@@ -83,9 +83,7 @@ local function new_view(root, x, y, data, ps, id)
local function calc_saturation(val)
if (type(data.build) == "table") and (type(data.build.transfer_cap) == "number") and (data.build.transfer_cap > 0) then
return val / data.build.transfer_cap
else
return 0
end
else return 0 end
end
charge.register(ps, "energy_fill", charge.update)

View File

@@ -28,6 +28,16 @@ local TEXT_ALIGN = core.TEXT_ALIGN
local cpair = core.cpair
local border = core.border
local bw_fg_bg = style.bw_fg_bg
local lu_cpair = style.lu_colors
local hzd_fg_bg = style.hzd_fg_bg
local dis_colors = style.dis_colors
local ind_grn = style.ind_grn
local ind_yel = style.ind_yel
local ind_red = style.ind_red
local ind_wht = style.ind_wht
local period = core.flasher.PERIOD
-- new process control view
@@ -40,11 +50,6 @@ local function new_view(root, x, y)
local facility = iocontrol.get_db().facility
local units = iocontrol.get_db().units
local bw_fg_bg = cpair(colors.black, colors.white)
local hzd_fg_bg = cpair(colors.white, colors.gray)
local lu_cpair = cpair(colors.gray, colors.gray)
local dis_colors = cpair(colors.white, colors.lightGray)
local main = Div{parent=root,width=128,height=24,x=x,y=y}
local scram = HazardButton{parent=main,x=1,y=1,text="FAC SCRAM",accent=colors.yellow,dis_colors=dis_colors,callback=process.fac_scram,fg_bg=hzd_fg_bg}
@@ -53,10 +58,10 @@ local function new_view(root, x, y)
facility.scram_ack = scram.on_response
facility.ack_alarms_ack = ack_a.on_response
local all_ok = IndicatorLight{parent=main,y=5,label="Unit Systems Online",colors=cpair(colors.green,colors.red)}
local all_ok = IndicatorLight{parent=main,y=5,label="Unit Systems Online",colors=ind_grn}
local rad_mon = TriIndicatorLight{parent=main,label="Radiation Monitor",c1=colors.gray,c2=colors.yellow,c3=colors.green}
local ind_mat = IndicatorLight{parent=main,label="Induction Matrix",colors=cpair(colors.green,colors.gray)}
local sps = IndicatorLight{parent=main,label="SPS Connected",colors=cpair(colors.green,colors.gray)}
local ind_mat = IndicatorLight{parent=main,label="Induction Matrix",colors=ind_grn}
local sps = IndicatorLight{parent=main,label="SPS Connected",colors=ind_grn}
all_ok.register(facility.ps, "all_sys_ok", all_ok.update)
rad_mon.register(facility.ps, "rad_computed_status", rad_mon.update)
@@ -65,10 +70,10 @@ local function new_view(root, x, y)
main.line_break()
local auto_ready = IndicatorLight{parent=main,label="Configured Units Ready",colors=cpair(colors.green,colors.red)}
local auto_act = IndicatorLight{parent=main,label="Process Active",colors=cpair(colors.green,colors.gray)}
local auto_ramp = IndicatorLight{parent=main,label="Process Ramping",colors=cpair(colors.white,colors.gray),flash=true,period=period.BLINK_250_MS}
local auto_sat = IndicatorLight{parent=main,label="Min/Max Burn Rate",colors=cpair(colors.yellow,colors.gray)}
local auto_ready = IndicatorLight{parent=main,label="Configured Units Ready",colors=ind_grn}
local auto_act = IndicatorLight{parent=main,label="Process Active",colors=ind_grn}
local auto_ramp = IndicatorLight{parent=main,label="Process Ramping",colors=ind_wht,flash=true,period=period.BLINK_250_MS}
local auto_sat = IndicatorLight{parent=main,label="Min/Max Burn Rate",colors=ind_yel}
auto_ready.register(facility.ps, "auto_ready", auto_ready.update)
auto_act.register(facility.ps, "auto_active", auto_act.update)
@@ -77,12 +82,12 @@ local function new_view(root, x, y)
main.line_break()
local auto_scram = IndicatorLight{parent=main,label="Automatic SCRAM",colors=cpair(colors.red,colors.gray),flash=true,period=period.BLINK_250_MS}
local matrix_dc = IndicatorLight{parent=main,label="Matrix Disconnected",colors=cpair(colors.yellow,colors.gray),flash=true,period=period.BLINK_500_MS}
local matrix_fill = IndicatorLight{parent=main,label="Matrix Charge High",colors=cpair(colors.red,colors.gray),flash=true,period=period.BLINK_500_MS}
local unit_crit = IndicatorLight{parent=main,label="Unit Critical Alarm",colors=cpair(colors.red,colors.gray),flash=true,period=period.BLINK_250_MS}
local fac_rad_h = IndicatorLight{parent=main,label="Facility Radiation High",colors=cpair(colors.red,colors.gray),flash=true,period=period.BLINK_250_MS}
local gen_fault = IndicatorLight{parent=main,label="Gen. Control Fault",colors=cpair(colors.yellow,colors.gray),flash=true,period=period.BLINK_500_MS}
local auto_scram = IndicatorLight{parent=main,label="Automatic SCRAM",colors=ind_red,flash=true,period=period.BLINK_250_MS}
local matrix_dc = IndicatorLight{parent=main,label="Matrix Disconnected",colors=ind_yel,flash=true,period=period.BLINK_500_MS}
local matrix_fill = IndicatorLight{parent=main,label="Matrix Charge High",colors=ind_red,flash=true,period=period.BLINK_500_MS}
local unit_crit = IndicatorLight{parent=main,label="Unit Critical Alarm",colors=ind_red,flash=true,period=period.BLINK_250_MS}
local fac_rad_h = IndicatorLight{parent=main,label="Facility Radiation High",colors=ind_red,flash=true,period=period.BLINK_250_MS}
local gen_fault = IndicatorLight{parent=main,label="Gen. Control Fault",colors=ind_yel,flash=true,period=period.BLINK_500_MS}
auto_scram.register(facility.ps, "auto_scram", auto_scram.update)
matrix_dc.register(facility.ps, "as_matrix_dc", matrix_dc.update)
@@ -198,12 +203,12 @@ local function new_view(root, x, y)
local stat_div = Div{parent=proc,width=22,height=24,x=57,y=6}
for i = 1, 4 do
local tag_fg_bg = cpair(colors.gray,colors.white)
local ind_fg_bg = cpair(colors.lightGray,colors.white)
local tag_fg_bg = cpair(colors.gray, colors.white)
local ind_fg_bg = cpair(colors.lightGray, colors.white)
local ind_off = colors.lightGray
if i <= facility.num_units then
tag_fg_bg = cpair(colors.black,colors.cyan)
tag_fg_bg = cpair(colors.black, colors.cyan)
ind_fg_bg = bw_fg_bg
ind_off = colors.gray
end
@@ -307,7 +312,7 @@ local function new_view(root, x, y)
local unit = units[i] ---@type ioctl_unit
TextBox{parent=waste_status,y=i,text="U"..i.." Waste",width=8,height=1}
local a_waste = IndicatorLight{parent=waste_status,x=10,y=i,label="Auto",colors=cpair(colors.white,colors.gray)}
local a_waste = IndicatorLight{parent=waste_status,x=10,y=i,label="Auto",colors=ind_wht}
local waste_m = StateIndicator{parent=waste_status,x=17,y=i,states=style.waste.states_abbrv,value=1,min_width=6}
a_waste.register(unit.unit_ps, "U_AutoWaste", a_waste.update)
@@ -330,7 +335,7 @@ local function new_view(root, x, y)
waste_prod.register(facility.ps, "process_waste_product", waste_prod.set_value)
pu_fallback.register(facility.ps, "process_pu_fallback", pu_fallback.set_value)
local fb_active = IndicatorLight{parent=rect,x=2,y=9,label="Fallback Active",colors=cpair(colors.white,colors.gray)}
local fb_active = IndicatorLight{parent=rect,x=2,y=9,label="Fallback Active",colors=ind_wht}
fb_active.register(facility.ps, "pu_fallback_active", fb_active.update)
@@ -341,7 +346,7 @@ local function new_view(root, x, y)
local po_rate = DataIndicator{parent=rect,x=2,label="",unit="mB/t",format="%12.2f",value=0,lu_colors=lu_cpair,fg_bg=bw_fg_bg,width=17}
TextBox{parent=rect,x=2,y=17,text="Antimatter Rate",height=1,width=17,fg_bg=style.label}
local am_rate = DataIndicator{parent=rect,x=2,label="",unit="\xb5B/t",format="%12.2f",value=0,lu_colors=lu_cpair,fg_bg=bw_fg_bg,width=17}
local am_rate = DataIndicator{parent=rect,x=2,label="",unit="\xb5B/t",format="%12d",value=0,lu_colors=lu_cpair,fg_bg=bw_fg_bg,width=17}
pu_rate.register(facility.ps, "pu_rate", pu_rate.update)
po_rate.register(facility.ps, "po_rate", po_rate.update)

View File

@@ -31,7 +31,7 @@ local function new_view(root, x, y, ps)
local flow_rate = DataIndicator{parent=turbine,x=5,y=4,lu_colors=lu_col,label="",unit="mB/t",format="%10.0f",value=0,commas=true,width=16,fg_bg=text_fg_bg}
status.register(ps, "computed_status", status.update)
prod_rate.register(ps, "prod_rate", function (val) prod_rate.update(util.joules_to_fe(val)) end)
prod_rate.register(ps, "steam_input_rate", function (val) prod_rate.update(util.joules_to_fe(val)) end)
flow_rate.register(ps, "flow_rate", flow_rate.update)
local steam = VerticalBar{parent=turbine,x=2,y=1,fg_bg=cpair(colors.white,colors.gray),height=4,width=1}

View File

@@ -31,6 +31,15 @@ local TEXT_ALIGN = core.TEXT_ALIGN
local cpair = core.cpair
local border = core.border
local bw_fg_bg = style.bw_fg_bg
local lu_cpair = style.lu_colors
local hzd_fg_bg = style.hzd_fg_bg
local ind_grn = style.ind_grn
local ind_yel = style.ind_yel
local ind_red = style.ind_red
local ind_wht = style.ind_wht
local period = core.flasher.PERIOD
-- create a unit view
@@ -50,10 +59,6 @@ local function init(parent, id)
TextBox{parent=main,text="Reactor Unit #" .. id,alignment=TEXT_ALIGN.CENTER,height=1,fg_bg=style.header}
local bw_fg_bg = cpair(colors.black, colors.white)
local hzd_fg_bg = cpair(colors.white, colors.gray)
local lu_cpair = cpair(colors.gray, colors.gray)
-----------------------------
-- main stats and core map --
-----------------------------
@@ -140,7 +145,7 @@ local function init(parent, id)
-- connectivity
local plc_online = IndicatorLight{parent=annunciator,label="PLC Online",colors=cpair(colors.green,colors.red)}
local plc_hbeat = IndicatorLight{parent=annunciator,label="PLC Heartbeat",colors=cpair(colors.white,colors.gray)}
local plc_hbeat = IndicatorLight{parent=annunciator,label="PLC Heartbeat",colors=ind_wht}
local rad_mon = TriIndicatorLight{parent=annunciator,label="Radiation Monitor",c1=colors.gray,c2=colors.yellow,c3=colors.green}
plc_online.register(u_ps, "PLCOnline", plc_online.update)
@@ -150,25 +155,25 @@ local function init(parent, id)
annunciator.line_break()
-- operating state
local r_active = IndicatorLight{parent=annunciator,label="Active",colors=cpair(colors.green,colors.gray)}
local r_auto = IndicatorLight{parent=annunciator,label="Automatic Control",colors=cpair(colors.white,colors.gray)}
local r_active = IndicatorLight{parent=annunciator,label="Active",colors=ind_grn}
local r_auto = IndicatorLight{parent=annunciator,label="Automatic Control",colors=ind_wht}
r_active.register(u_ps, "status", r_active.update)
r_auto.register(u_ps, "AutoControl", r_auto.update)
-- main unit transient/warning annunciator panel
local r_scram = IndicatorLight{parent=annunciator,label="Reactor SCRAM",colors=cpair(colors.red,colors.gray)}
local r_mscrm = IndicatorLight{parent=annunciator,label="Manual Reactor SCRAM",colors=cpair(colors.red,colors.gray)}
local r_ascrm = IndicatorLight{parent=annunciator,label="Auto Reactor SCRAM",colors=cpair(colors.red,colors.gray)}
local rad_wrn = IndicatorLight{parent=annunciator,label="Radiation Warning",colors=cpair(colors.yellow,colors.gray)}
local r_rtrip = IndicatorLight{parent=annunciator,label="RCP Trip",colors=cpair(colors.red,colors.gray)}
local r_cflow = IndicatorLight{parent=annunciator,label="RCS Flow Low",colors=cpair(colors.yellow,colors.gray)}
local r_clow = IndicatorLight{parent=annunciator,label="Coolant Level Low",colors=cpair(colors.yellow,colors.gray)}
local r_temp = IndicatorLight{parent=annunciator,label="Reactor Temp. High",colors=cpair(colors.red,colors.gray)}
local r_rhdt = IndicatorLight{parent=annunciator,label="Reactor High Delta T",colors=cpair(colors.yellow,colors.gray)}
local r_firl = IndicatorLight{parent=annunciator,label="Fuel Input Rate Low",colors=cpair(colors.yellow,colors.gray)}
local r_wloc = IndicatorLight{parent=annunciator,label="Waste Line Occlusion",colors=cpair(colors.yellow,colors.gray)}
local r_hsrt = IndicatorLight{parent=annunciator,label="Startup Rate High",colors=cpair(colors.yellow,colors.gray)}
local r_scram = IndicatorLight{parent=annunciator,label="Reactor SCRAM",colors=ind_red}
local r_mscrm = IndicatorLight{parent=annunciator,label="Manual Reactor SCRAM",colors=ind_red}
local r_ascrm = IndicatorLight{parent=annunciator,label="Auto Reactor SCRAM",colors=ind_red}
local rad_wrn = IndicatorLight{parent=annunciator,label="Radiation Warning",colors=ind_yel}
local r_rtrip = IndicatorLight{parent=annunciator,label="RCP Trip",colors=ind_red}
local r_cflow = IndicatorLight{parent=annunciator,label="RCS Flow Low",colors=ind_yel}
local r_clow = IndicatorLight{parent=annunciator,label="Coolant Level Low",colors=ind_yel}
local r_temp = IndicatorLight{parent=annunciator,label="Reactor Temp. High",colors=ind_red}
local r_rhdt = IndicatorLight{parent=annunciator,label="Reactor High Delta T",colors=ind_yel}
local r_firl = IndicatorLight{parent=annunciator,label="Fuel Input Rate Low",colors=ind_yel}
local r_wloc = IndicatorLight{parent=annunciator,label="Waste Line Occlusion",colors=ind_yel}
local r_hsrt = IndicatorLight{parent=annunciator,label="Startup Rate High",colors=ind_yel}
r_scram.register(u_ps, "ReactorSCRAM", r_scram.update)
r_mscrm.register(u_ps, "ManualReactorSCRAM", r_mscrm.update)
@@ -189,15 +194,15 @@ local function init(parent, id)
local rps = Rectangle{parent=main,border=border(1,colors.cyan,true),thin=true,width=33,height=12,x=46,y=9}
local rps_annunc = Div{parent=rps,width=31,height=10,x=2,y=1}
local rps_trp = IndicatorLight{parent=rps_annunc,label="RPS Trip",colors=cpair(colors.red,colors.gray),flash=true,period=period.BLINK_250_MS}
local rps_dmg = IndicatorLight{parent=rps_annunc,label="Damage Level High",colors=cpair(colors.red,colors.gray),flash=true,period=period.BLINK_250_MS}
local rps_exh = IndicatorLight{parent=rps_annunc,label="Excess Heated Coolant",colors=cpair(colors.yellow,colors.gray)}
local rps_exw = IndicatorLight{parent=rps_annunc,label="Excess Waste",colors=cpair(colors.yellow,colors.gray)}
local rps_tmp = IndicatorLight{parent=rps_annunc,label="Core Temperature High",colors=cpair(colors.red,colors.gray),flash=true,period=period.BLINK_250_MS}
local rps_nof = IndicatorLight{parent=rps_annunc,label="No Fuel",colors=cpair(colors.yellow,colors.gray)}
local rps_loc = IndicatorLight{parent=rps_annunc,label="Coolant Level Low Low",colors=cpair(colors.yellow,colors.gray)}
local rps_flt = IndicatorLight{parent=rps_annunc,label="PPM Fault",colors=cpair(colors.yellow,colors.gray),flash=true,period=period.BLINK_500_MS}
local rps_tmo = IndicatorLight{parent=rps_annunc,label="Connection Timeout",colors=cpair(colors.yellow,colors.gray),flash=true,period=period.BLINK_500_MS}
local rps_trp = IndicatorLight{parent=rps_annunc,label="RPS Trip",colors=ind_red,flash=true,period=period.BLINK_250_MS}
local rps_dmg = IndicatorLight{parent=rps_annunc,label="Damage Level High",colors=ind_red,flash=true,period=period.BLINK_250_MS}
local rps_exh = IndicatorLight{parent=rps_annunc,label="Excess Heated Coolant",colors=ind_yel}
local rps_exw = IndicatorLight{parent=rps_annunc,label="Excess Waste",colors=ind_yel}
local rps_tmp = IndicatorLight{parent=rps_annunc,label="Core Temperature High",colors=ind_red,flash=true,period=period.BLINK_250_MS}
local rps_nof = IndicatorLight{parent=rps_annunc,label="No Fuel",colors=ind_yel}
local rps_loc = IndicatorLight{parent=rps_annunc,label="Coolant Level Low Low",colors=ind_yel}
local rps_flt = IndicatorLight{parent=rps_annunc,label="PPM Fault",colors=ind_yel,flash=true,period=period.BLINK_500_MS}
local rps_tmo = IndicatorLight{parent=rps_annunc,label="Connection Timeout",colors=ind_yel,flash=true,period=period.BLINK_500_MS}
local rps_sfl = IndicatorLight{parent=rps_annunc,label="System Failure",colors=cpair(colors.orange,colors.gray),flash=true,period=period.BLINK_500_MS}
rps_trp.register(u_ps, "rps_tripped", rps_trp.update)
@@ -218,12 +223,12 @@ local function init(parent, id)
local rcs_annunc = Div{parent=rcs,width=27,height=22,x=3,y=1}
local rcs_tags = Div{parent=rcs,width=2,height=16,x=1,y=7}
local c_flt = IndicatorLight{parent=rcs_annunc,label="RCS Hardware Fault",colors=cpair(colors.yellow,colors.gray)}
local c_flt = IndicatorLight{parent=rcs_annunc,label="RCS Hardware Fault",colors=ind_yel}
local c_emg = TriIndicatorLight{parent=rcs_annunc,label="Emergency Coolant",c1=colors.gray,c2=colors.white,c3=colors.green}
local c_cfm = IndicatorLight{parent=rcs_annunc,label="Coolant Feed Mismatch",colors=cpair(colors.yellow,colors.gray)}
local c_brm = IndicatorLight{parent=rcs_annunc,label="Boil Rate Mismatch",colors=cpair(colors.yellow,colors.gray)}
local c_sfm = IndicatorLight{parent=rcs_annunc,label="Steam Feed Mismatch",colors=cpair(colors.yellow,colors.gray)}
local c_mwrf = IndicatorLight{parent=rcs_annunc,label="Max Water Return Feed",colors=cpair(colors.yellow,colors.gray)}
local c_cfm = IndicatorLight{parent=rcs_annunc,label="Coolant Feed Mismatch",colors=ind_yel}
local c_brm = IndicatorLight{parent=rcs_annunc,label="Boil Rate Mismatch",colors=ind_yel}
local c_sfm = IndicatorLight{parent=rcs_annunc,label="Steam Feed Mismatch",colors=ind_yel}
local c_mwrf = IndicatorLight{parent=rcs_annunc,label="Max Water Return Feed",colors=ind_yel}
c_flt.register(u_ps, "RCSFault", c_flt.update)
c_emg.register(u_ps, "EmergencyCoolant", c_emg.update)
@@ -246,11 +251,11 @@ local function init(parent, id)
if unit.num_boilers > 0 then
TextBox{parent=rcs_tags,x=1,text="B1",width=2,height=1,fg_bg=bw_fg_bg}
local b1_wll = IndicatorLight{parent=rcs_annunc,label="Water Level Low",colors=cpair(colors.red,colors.gray)}
local b1_wll = IndicatorLight{parent=rcs_annunc,label="Water Level Low",colors=ind_red}
b1_wll.register(b_ps[1], "WasterLevelLow", b1_wll.update)
TextBox{parent=rcs_tags,text="B1",width=2,height=1,fg_bg=bw_fg_bg}
local b1_hr = IndicatorLight{parent=rcs_annunc,label="Heating Rate Low",colors=cpair(colors.yellow,colors.gray)}
local b1_hr = IndicatorLight{parent=rcs_annunc,label="Heating Rate Low",colors=ind_yel}
b1_hr.register(b_ps[1], "HeatingRateLow", b1_hr.update)
end
if unit.num_boilers > 1 then
@@ -262,11 +267,11 @@ local function init(parent, id)
end
TextBox{parent=rcs_tags,text="B2",width=2,height=1,fg_bg=bw_fg_bg}
local b2_wll = IndicatorLight{parent=rcs_annunc,label="Water Level Low",colors=cpair(colors.red,colors.gray)}
local b2_wll = IndicatorLight{parent=rcs_annunc,label="Water Level Low",colors=ind_red}
b2_wll.register(b_ps[2], "WasterLevelLow", b2_wll.update)
TextBox{parent=rcs_tags,text="B2",width=2,height=1,fg_bg=bw_fg_bg}
local b2_hr = IndicatorLight{parent=rcs_annunc,label="Heating Rate Low",colors=cpair(colors.yellow,colors.gray)}
local b2_hr = IndicatorLight{parent=rcs_annunc,label="Heating Rate Low",colors=ind_yel}
b2_hr.register(b_ps[2], "HeatingRateLow", b2_hr.update)
end
@@ -279,15 +284,15 @@ local function init(parent, id)
t1_sdo.register(t_ps[1], "SteamDumpOpen", t1_sdo.update)
TextBox{parent=rcs_tags,text="T1",width=2,height=1,fg_bg=bw_fg_bg}
local t1_tos = IndicatorLight{parent=rcs_annunc,label="Turbine Over Speed",colors=cpair(colors.red,colors.gray)}
local t1_tos = IndicatorLight{parent=rcs_annunc,label="Turbine Over Speed",colors=ind_red}
t1_tos.register(t_ps[1], "TurbineOverSpeed", t1_tos.update)
TextBox{parent=rcs_tags,text="T1",width=2,height=1,fg_bg=bw_fg_bg}
local t1_gtrp = IndicatorLight{parent=rcs_annunc,label="Generator Trip",colors=cpair(colors.yellow,colors.gray),flash=true,period=period.BLINK_250_MS}
local t1_gtrp = IndicatorLight{parent=rcs_annunc,label="Generator Trip",colors=ind_yel,flash=true,period=period.BLINK_250_MS}
t1_gtrp.register(t_ps[1], "GeneratorTrip", t1_gtrp.update)
TextBox{parent=rcs_tags,text="T1",width=2,height=1,fg_bg=bw_fg_bg}
local t1_trp = IndicatorLight{parent=rcs_annunc,label="Turbine Trip",colors=cpair(colors.red,colors.gray),flash=true,period=period.BLINK_250_MS}
local t1_trp = IndicatorLight{parent=rcs_annunc,label="Turbine Trip",colors=ind_red,flash=true,period=period.BLINK_250_MS}
t1_trp.register(t_ps[1], "TurbineTrip", t1_trp.update)
if unit.num_turbines > 1 then
@@ -300,15 +305,15 @@ local function init(parent, id)
t2_sdo.register(t_ps[2], "SteamDumpOpen", t2_sdo.update)
TextBox{parent=rcs_tags,text="T2",width=2,height=1,fg_bg=bw_fg_bg}
local t2_tos = IndicatorLight{parent=rcs_annunc,label="Turbine Over Speed",colors=cpair(colors.red,colors.gray)}
local t2_tos = IndicatorLight{parent=rcs_annunc,label="Turbine Over Speed",colors=ind_red}
t2_tos.register(t_ps[2], "TurbineOverSpeed", t2_tos.update)
TextBox{parent=rcs_tags,text="T2",width=2,height=1,fg_bg=bw_fg_bg}
local t2_gtrp = IndicatorLight{parent=rcs_annunc,label="Generator Trip",colors=cpair(colors.yellow,colors.gray),flash=true,period=period.BLINK_250_MS}
local t2_gtrp = IndicatorLight{parent=rcs_annunc,label="Generator Trip",colors=ind_yel,flash=true,period=period.BLINK_250_MS}
t2_gtrp.register(t_ps[2], "GeneratorTrip", t2_gtrp.update)
TextBox{parent=rcs_tags,text="T2",width=2,height=1,fg_bg=bw_fg_bg}
local t2_trp = IndicatorLight{parent=rcs_annunc,label="Turbine Trip",colors=cpair(colors.red,colors.gray),flash=true,period=period.BLINK_250_MS}
local t2_trp = IndicatorLight{parent=rcs_annunc,label="Turbine Trip",colors=ind_red,flash=true,period=period.BLINK_250_MS}
t2_trp.register(t_ps[2], "TurbineTrip", t2_trp.update)
end
@@ -320,15 +325,15 @@ local function init(parent, id)
t3_sdo.register(t_ps[3], "SteamDumpOpen", t3_sdo.update)
TextBox{parent=rcs_tags,text="T3",width=2,height=1,fg_bg=bw_fg_bg}
local t3_tos = IndicatorLight{parent=rcs_annunc,label="Turbine Over Speed",colors=cpair(colors.red,colors.gray)}
local t3_tos = IndicatorLight{parent=rcs_annunc,label="Turbine Over Speed",colors=ind_red}
t3_tos.register(t_ps[3], "TurbineOverSpeed", t3_tos.update)
TextBox{parent=rcs_tags,text="T3",width=2,height=1,fg_bg=bw_fg_bg}
local t3_gtrp = IndicatorLight{parent=rcs_annunc,label="Generator Trip",colors=cpair(colors.yellow,colors.gray),flash=true,period=period.BLINK_250_MS}
local t3_gtrp = IndicatorLight{parent=rcs_annunc,label="Generator Trip",colors=ind_yel,flash=true,period=period.BLINK_250_MS}
t3_gtrp.register(t_ps[3], "GeneratorTrip", t3_gtrp.update)
TextBox{parent=rcs_tags,text="T3",width=2,height=1,fg_bg=bw_fg_bg}
local t3_trp = IndicatorLight{parent=rcs_annunc,label="Turbine Trip",colors=cpair(colors.red,colors.gray),flash=true,period=period.BLINK_250_MS}
local t3_trp = IndicatorLight{parent=rcs_annunc,label="Turbine Trip",colors=ind_red,flash=true,period=period.BLINK_250_MS}
t3_trp.register(t_ps[3], "TurbineTrip", t3_trp.update)
end
@@ -343,7 +348,7 @@ local function init(parent, id)
TextBox{parent=burn_control,x=9,y=2,text="mB/t"}
local set_burn = function () unit.set_burn(burn_rate.get_value()) end
local set_burn_btn = PushButton{parent=burn_control,x=14,y=2,text="SET",min_width=5,fg_bg=cpair(colors.black,colors.yellow),active_fg_bg=cpair(colors.white,colors.gray),dis_fg_bg=dis_colors,callback=set_burn}
local set_burn_btn = PushButton{parent=burn_control,x=14,y=2,text="SET",min_width=5,fg_bg=cpair(colors.black,colors.yellow),active_fg_bg=style.wh_gray,dis_fg_bg=dis_colors,callback=set_burn}
burn_rate.register(u_ps, "burn_rate", burn_rate.set_value)
burn_rate.register(u_ps, "max_burn", burn_rate.set_max)
@@ -475,7 +480,7 @@ local function init(parent, id)
auto_div.line_break()
local function set_group() unit.set_group(group.get_value() - 1) end
local set_grp_btn = PushButton{parent=auto_div,text="SET",x=4,min_width=5,fg_bg=cpair(colors.black,colors.yellow),active_fg_bg=cpair(colors.white,colors.gray),dis_fg_bg=cpair(colors.gray,colors.white),callback=set_group}
local set_grp_btn = PushButton{parent=auto_div,text="SET",x=4,min_width=5,fg_bg=cpair(colors.black,colors.yellow),active_fg_bg=style.wh_gray,dis_fg_bg=cpair(colors.gray,colors.white),callback=set_group}
auto_div.line_break()
@@ -486,8 +491,8 @@ local function init(parent, id)
auto_div.line_break()
local a_rdy = IndicatorLight{parent=auto_div,label="Ready",x=2,colors=cpair(colors.green,colors.gray)}
local a_stb = IndicatorLight{parent=auto_div,label="Standby",x=2,colors=cpair(colors.white,colors.gray),flash=true,period=period.BLINK_1000_MS}
local a_rdy = IndicatorLight{parent=auto_div,label="Ready",x=2,colors=ind_grn}
local a_stb = IndicatorLight{parent=auto_div,label="Standby",x=2,colors=ind_wht,flash=true,period=period.BLINK_1000_MS}
a_rdy.register(u_ps, "U_AutoReady", a_rdy.update)

View File

@@ -0,0 +1,225 @@
--
-- Basic Unit Flow Overview
--
local util = require("scada-common.util")
local style = require("coordinator.ui.style")
local core = require("graphics.core")
local Div = require("graphics.elements.div")
local PipeNetwork = require("graphics.elements.pipenet")
local TextBox = require("graphics.elements.textbox")
local Rectangle = require("graphics.elements.rectangle")
local DataIndicator = require("graphics.elements.indicators.data")
local IndicatorLight = require("graphics.elements.indicators.light")
local TriIndicatorLight = require("graphics.elements.indicators.trilight")
local TEXT_ALIGN = core.TEXT_ALIGN
local sprintf = util.sprintf
local cpair = core.cpair
local border = core.border
local pipe = core.pipe
local wh_gray = style.wh_gray
local bw_fg_bg = style.bw_fg_bg
local text_c = style.text_colors
local lu_c = style.lu_colors
local ind_grn = style.ind_grn
local ind_wht = style.ind_wht
-- make a new unit flow window
---@param parent graphics_element parent
---@param x integer top left x
---@param y integer top left y
---@param wide boolean whether to render wide version
---@param unit ioctl_unit unit database entry
local function make(parent, x, y, wide, unit)
local height = 16
local v_start = 1 + ((unit.unit_id - 1) * 5)
local prv_start = 1 + ((unit.unit_id - 1) * 3)
local v_fields = { "pu", "po", "pl", "am" }
local v_names = {
sprintf("PV%02d-PU", v_start),
sprintf("PV%02d-PO", v_start + 1),
sprintf("PV%02d-PL", v_start + 2),
sprintf("PV%02d-AM", v_start + 3),
sprintf("PRV%02d", prv_start),
sprintf("PRV%02d", prv_start + 1),
sprintf("PRV%02d", prv_start + 2)
}
assert(parent.get_height() >= (y + height), "flow display not of sufficient vertical resolution (add an additional row of monitors) " .. y .. "," .. parent.get_height())
local function _wide(a, b) return util.trinary(wide, a, b) end
-- bounding box div
local root = Div{parent=parent,x=x,y=y,width=_wide(136, 114),height=height}
local lg_gray = cpair(colors.lightGray, colors.gray)
------------------
-- COOLING LOOP --
------------------
local reactor = Rectangle{parent=root,x=1,y=1,border=border(1,colors.gray,true),width=19,height=5,fg_bg=wh_gray}
TextBox{parent=reactor,y=1,text="FISSION REACTOR",alignment=TEXT_ALIGN.CENTER,height=1}
TextBox{parent=reactor,y=3,text="UNIT #"..unit.unit_id,alignment=TEXT_ALIGN.CENTER,height=1}
TextBox{parent=root,x=19,y=2,text="\x1b \x80 \x1a",width=1,height=3,fg_bg=lg_gray}
TextBox{parent=root,x=3,y=5,text="\x19",width=1,height=1,fg_bg=lg_gray}
local rc_pipes = {}
local emc_x = 42 -- emergency coolant connection x point
if unit.num_boilers > 0 then
table.insert(rc_pipes, pipe(0, 1, _wide(28, 19), 1, colors.lightBlue, true))
table.insert(rc_pipes, pipe(0, 3, _wide(28, 19), 3, colors.orange, true))
table.insert(rc_pipes, pipe(_wide(46 ,39), 1, _wide(72,58), 1, colors.blue, true))
table.insert(rc_pipes, pipe(_wide(46,39), 3, _wide(72,58), 3, colors.white, true))
else
emc_x = 3
table.insert(rc_pipes, pipe(0, 1, _wide(72,58), 1, colors.blue, true))
table.insert(rc_pipes, pipe(0, 3, _wide(72,58), 3, colors.white, true))
end
if unit.has_tank then
table.insert(rc_pipes, pipe(emc_x, 1, emc_x, 0, colors.blue, true, true))
end
local prv_yo = math.max(3 - unit.num_turbines, 0)
for i = 1, unit.num_turbines do
local py = 2 * (i - 1) + prv_yo
table.insert(rc_pipes, pipe(_wide(92, 78), py, _wide(104, 83), py, colors.white, true))
end
PipeNetwork{parent=root,x=20,y=1,pipes=rc_pipes,bg=colors.lightGray}
if unit.num_boilers > 0 then
local cc_rate = DataIndicator{parent=root,x=_wide(25,22),y=5,lu_colors=lu_c,label="",unit="mB/t",format="%11.0f",value=0,commas=true,width=16,fg_bg=bw_fg_bg}
local hc_rate = DataIndicator{parent=root,x=_wide(25,22),y=3,lu_colors=lu_c,label="",unit="mB/t",format="%11.0f",value=0,commas=true,width=16,fg_bg=bw_fg_bg}
cc_rate.register(unit.unit_ps, "boil_sum", cc_rate.update)
hc_rate.register(unit.unit_ps, "heating_rate", hc_rate.update)
local boiler = Rectangle{parent=root,x=_wide(47,40),y=1,border=border(1, colors.gray, true),width=19,height=5,fg_bg=wh_gray}
TextBox{parent=boiler,y=1,text="THERMO-ELECTRIC",alignment=TEXT_ALIGN.CENTER,height=1}
TextBox{parent=boiler,y=3,text="BOILERS",alignment=TEXT_ALIGN.CENTER,height=1}
TextBox{parent=root,x=_wide(47,40),y=2,text="\x1b \x80 \x1a",width=1,height=3,fg_bg=lg_gray}
TextBox{parent=root,x=_wide(65,58),y=2,text="\x1b \x80 \x1a",width=1,height=3,fg_bg=lg_gray}
local wt_rate = DataIndicator{parent=root,x=_wide(71,61),y=3,lu_colors=lu_c,label="",unit="mB/t",format="%11.0f",value=0,commas=true,width=16,fg_bg=bw_fg_bg}
local st_rate = DataIndicator{parent=root,x=_wide(71,61),y=5,lu_colors=lu_c,label="",unit="mB/t",format="%11.0f",value=0,commas=true,width=16,fg_bg=bw_fg_bg}
wt_rate.register(unit.unit_ps, "turbine_flow_sum", wt_rate.update)
st_rate.register(unit.unit_ps, "boil_sum", st_rate.update)
else
local wt_rate = DataIndicator{parent=root,x=28,y=3,lu_colors=lu_c,label="",unit="mB/t",format="%11.0f",value=0,commas=true,width=16,fg_bg=bw_fg_bg}
local st_rate = DataIndicator{parent=root,x=28,y=5,lu_colors=lu_c,label="",unit="mB/t",format="%11.0f",value=0,commas=true,width=16,fg_bg=bw_fg_bg}
wt_rate.register(unit.unit_ps, "turbine_flow_sum", wt_rate.update)
st_rate.register(unit.unit_ps, "heating_rate", st_rate.update)
end
local turbine = Rectangle{parent=root,x=_wide(93,79),y=1,border=border(1, colors.gray, true),width=19,height=5,fg_bg=wh_gray}
TextBox{parent=turbine,y=1,text="STEAM TURBINE",alignment=TEXT_ALIGN.CENTER,height=1}
TextBox{parent=turbine,y=3,text=util.trinary(unit.num_turbines>1,"GENERATORS","GENERATOR"),alignment=TEXT_ALIGN.CENTER,height=1}
TextBox{parent=root,x=_wide(93,79),y=2,text="\x1b \x80 \x1a",width=1,height=3,fg_bg=lg_gray}
for i = 1, unit.num_turbines do
local ry = 1 + (2 * (i - 1)) + prv_yo
TextBox{parent=root,x=_wide(125,103),y=ry,text="\x10\x11\x7f",fg_bg=text_c,width=3,height=1}
local state = TriIndicatorLight{parent=root,x=_wide(129,107),y=ry,label=v_names[i+4],c1=colors.gray,c2=colors.yellow,c3=colors.red}
state.register(unit.turbine_ps_tbl[i], "SteamDumpOpen", state.update)
end
----------------------
-- WASTE PROCESSING --
----------------------
local waste = Div{parent=root,x=3,y=6}
local waste_pipes = {
pipe(0, 0, _wide(19, 16), 1, colors.brown, true),
pipe(_wide(14, 13), 1, _wide(19, 17), 5, colors.brown, true),
pipe(_wide(22, 19), 1, _wide(49, 45), 1, colors.brown, true),
pipe(_wide(22, 19), 5, _wide(28, 24), 5, colors.brown, true),
pipe(_wide(64, 53), 1, _wide(95, 81), 1, colors.green, true),
pipe(_wide(48, 43), 4, _wide(71, 61), 4, colors.cyan, true),
pipe(_wide(66, 57), 4, _wide(71, 61), 8, colors.cyan, true),
pipe(_wide(74, 63), 4, _wide(95, 81), 4, colors.cyan, true),
pipe(_wide(74, 63), 8, _wide(133, 111), 8, colors.cyan, true),
pipe(_wide(108, 94), 1, _wide(132, 110), 6, colors.black, true, true),
pipe(_wide(108, 94), 4, _wide(111, 95), 1, colors.black, true, true),
pipe(_wide(132, 110), 6, _wide(130, 108), 6, colors.black, true, true)
}
PipeNetwork{parent=waste,x=1,y=1,pipes=waste_pipes,bg=colors.lightGray}
local function _valve(vx, vy, n)
TextBox{parent=waste,x=vx,y=vy,text="\x10\x11",fg_bg=text_c,width=2,height=1}
local conn = IndicatorLight{parent=waste,x=vx-3,y=vy+1,label=v_names[n],colors=ind_grn}
local open = IndicatorLight{parent=waste,x=vx-3,y=vy+2,label="OPEN",colors=ind_wht}
conn.register(unit.unit_ps, util.c("V_", v_fields[n], "_conn"), conn.update)
open.register(unit.unit_ps, util.c("V_", v_fields[n], "_state"), open.update)
end
local function _machine(mx, my, name)
local l = string.len(name) + 2
TextBox{parent=waste,x=mx,y=my,text=string.rep("\x8f",l),alignment=TEXT_ALIGN.CENTER,fg_bg=lg_gray,width=l,height=1}
TextBox{parent=waste,x=mx,y=my+1,text=name,alignment=TEXT_ALIGN.CENTER,fg_bg=wh_gray,width=l,height=1}
end
local waste_rate = DataIndicator{parent=waste,x=1,y=3,lu_colors=lu_c,label="",unit="mB/t",format="%7.2f",value=0,width=12,fg_bg=bw_fg_bg}
local pu_rate = DataIndicator{parent=waste,x=_wide(82,70),y=3,lu_colors=lu_c,label="",unit="mB/t",format="%7.3f",value=0,width=12,fg_bg=bw_fg_bg}
local po_rate = DataIndicator{parent=waste,x=_wide(52,45),y=6,lu_colors=lu_c,label="",unit="mB/t",format="%7.3f",value=0,width=12,fg_bg=bw_fg_bg}
local popl_rate = DataIndicator{parent=waste,x=_wide(82,70),y=6,lu_colors=lu_c,label="",unit="mB/t",format="%7.3f",value=0,width=12,fg_bg=bw_fg_bg}
local poam_rate = DataIndicator{parent=waste,x=_wide(82,70),y=10,lu_colors=lu_c,label="",unit="mB/t",format="%7.3f",value=0,width=12,fg_bg=bw_fg_bg}
local spent_rate = DataIndicator{parent=waste,x=_wide(117,99),y=3,lu_colors=lu_c,label="",unit="mB/t",format="%7.3f",value=0,width=12,fg_bg=bw_fg_bg}
waste_rate.register(unit.unit_ps, "act_burn_rate", waste_rate.update)
pu_rate.register(unit.unit_ps, "pu_rate", pu_rate.update)
po_rate.register(unit.unit_ps, "po_rate", po_rate.update)
popl_rate.register(unit.unit_ps, "po_pl_rate", popl_rate.update)
poam_rate.register(unit.unit_ps, "po_am_rate", poam_rate.update)
spent_rate.register(unit.unit_ps, "ws_rate", spent_rate.update)
_valve(_wide(21, 18), 2, 1)
_valve(_wide(21, 18), 6, 2)
_valve(_wide(73, 62), 5, 3)
_valve(_wide(73, 62), 9, 4)
_machine(_wide(51, 45), 1, "CENTRIFUGE \x1a");
_machine(_wide(97, 83), 1, "PRC [Pu] \x1a");
_machine(_wide(97, 83), 4, "PRC [Po] \x1a");
_machine(_wide(116, 94), 6, "SPENT WASTE \x1b")
TextBox{parent=waste,x=_wide(30,25),y=3,text="SNAs [Po]",alignment=TEXT_ALIGN.CENTER,width=19,height=1,fg_bg=wh_gray}
local sna_po = Rectangle{parent=waste,x=_wide(30,25),y=4,border=border(1,colors.gray,true),width=19,height=7,thin=true,fg_bg=bw_fg_bg}
local sna_act = IndicatorLight{parent=sna_po,label="ACTIVE",colors=ind_grn}
local sna_cnt = DataIndicator{parent=sna_po,x=12,y=1,lu_colors=lu_c,label="CNT",unit="",format="%2d",value=0,width=7}
local sna_pk = DataIndicator{parent=sna_po,y=3,lu_colors=lu_c,label="PEAK",unit="mB/t",format="%7.2f",value=0,width=17}
local sna_max = DataIndicator{parent=sna_po,lu_colors=lu_c,label="MAX",unit="mB/t",format="%8.2f",value=0,width=17}
local sna_in = DataIndicator{parent=sna_po,lu_colors=lu_c,label="IN",unit="mB/t",format="%9.2f",value=0,width=17}
sna_act.register(unit.unit_ps, "po_rate", function (r) sna_act.update(r > 0) end)
sna_cnt.register(unit.unit_ps, "sna_count", sna_cnt.update)
sna_pk.register(unit.unit_ps, "sna_peak_rate", sna_pk.update)
sna_max.register(unit.unit_ps, "sna_prod_rate", sna_max.update)
sna_in.register(unit.unit_ps, "sna_in", sna_in.update)
return root
end
return make

View File

@@ -0,0 +1,381 @@
--
-- Flow Monitor GUI
--
local types = require("scada-common.types")
local util = require("scada-common.util")
local iocontrol = require("coordinator.iocontrol")
local style = require("coordinator.ui.style")
local unit_flow = require("coordinator.ui.components.unit_flow")
local core = require("graphics.core")
local Div = require("graphics.elements.div")
local PipeNetwork = require("graphics.elements.pipenet")
local Rectangle = require("graphics.elements.rectangle")
local TextBox = require("graphics.elements.textbox")
local DataIndicator = require("graphics.elements.indicators.data")
local HorizontalBar = require("graphics.elements.indicators.hbar")
local IndicatorLight = require("graphics.elements.indicators.light")
local StateIndicator = require("graphics.elements.indicators.state")
local CONTAINER_MODE = types.CONTAINER_MODE
local TEXT_ALIGN = core.TEXT_ALIGN
local cpair = core.cpair
local border = core.border
local pipe = core.pipe
local wh_gray = style.wh_gray
local bw_fg_bg = style.bw_fg_bg
local text_col = style.text_colors
local lu_col = style.lu_colors
-- create new flow view
---@param main graphics_element main displaybox
local function init(main)
local facility = iocontrol.get_db().facility
local units = iocontrol.get_db().units
local tank_defs = facility.tank_defs
local tank_list = facility.tank_list
-- window header message
local header = TextBox{parent=main,y=1,text="Facility Coolant and Waste Flow Monitor",alignment=TEXT_ALIGN.CENTER,height=1,fg_bg=style.header}
-- max length example: "01:23:45 AM - Wednesday, September 28 2022"
local datetime = TextBox{parent=main,x=(header.get_width()-42),y=1,text="",alignment=TEXT_ALIGN.RIGHT,width=42,height=1,fg_bg=style.header}
datetime.register(facility.ps, "date_time", datetime.set_value)
local po_pipes = {}
local water_pipes = {}
-- get the y offset for this unit index
---@param idx integer unit index
local function y_ofs(idx) return ((idx - 1) * 20) end
-- determinte facility tank start/end from the definitions list
---@param start_idx integer start index of table iteration
---@param end_idx integer end index of table iteration
local function find_fdef(start_idx, end_idx)
local first, last = 4, 0
for i = start_idx, end_idx do
if tank_defs[i] == 2 then
last = i
if i < first then first = i end
end
end
return first, last
end
if facility.tank_mode == 0 or facility.tank_mode == 8 then
-- (0) tanks belong to reactor units OR (8) 4 total facility tanks (A B C D)
for i = 1, facility.num_units do
if units[i].has_tank then
local y = y_ofs(i)
table.insert(water_pipes, pipe(2, y, 2, y + 3, colors.blue, true))
table.insert(water_pipes, pipe(2, y, 21, y, colors.blue, true))
local u = units[i] ---@type ioctl_unit
local x = util.trinary(u.num_boilers == 0, 45, 84)
table.insert(water_pipes, pipe(21, y, x, y + 2, colors.blue, true, true))
end
end
else
-- setup connections for units with emergency coolant, always the same
for i = 1, #tank_defs do
if tank_defs[i] > 0 then
local y = y_ofs(i)
if tank_defs[i] == 2 then
table.insert(water_pipes, pipe(1, y, 21, y, colors.blue, true))
else
table.insert(water_pipes, pipe(2, y, 2, y + 3, colors.blue, true))
table.insert(water_pipes, pipe(2, y, 21, y, colors.blue, true))
end
local u = units[i] ---@type ioctl_unit
local x = util.trinary(u.num_boilers == 0, 45, 84)
table.insert(water_pipes, pipe(21, y, x, y + 2, colors.blue, true, true))
end
end
if facility.tank_mode == 1 then
-- (1) 1 total facility tank (A A A A)
local first_fdef, last_fdef = find_fdef(1, #tank_defs)
for i = 1, #tank_defs do
local y = y_ofs(i)
if i == first_fdef then
table.insert(water_pipes, pipe(0, y, 1, y + 5, colors.blue, true))
elseif i > first_fdef then
if i == last_fdef then
table.insert(water_pipes, pipe(0, y - 14, 0, y, colors.blue, true))
elseif i < last_fdef then
table.insert(water_pipes, pipe(0, y - 14, 0, y + 5, colors.blue, true))
end
end
end
elseif facility.tank_mode == 2 then
-- (2) 2 total facility tanks (A A A B)
local first_fdef, last_fdef = find_fdef(1, math.min(3, #tank_defs))
for i = 1, #tank_defs do
local y = y_ofs(i)
if i == 4 then
if tank_defs[i] == 2 then
table.insert(water_pipes, pipe(0, y, 1, y + 5, colors.blue, true))
end
elseif i == first_fdef then
table.insert(water_pipes, pipe(0, y, 1, y + 5, colors.blue, true))
elseif i > first_fdef then
if i == last_fdef then
table.insert(water_pipes, pipe(0, y - 14, 0, y, colors.blue, true))
elseif i < last_fdef then
table.insert(water_pipes, pipe(0, y - 14, 0, y + 5, colors.blue, true))
end
end
end
elseif facility.tank_mode == 3 then
-- (3) 2 total facility tanks (A A B B)
for _, a in pairs({ 1, 3 }) do
local b = a + 1
if tank_defs[a] == 2 then
table.insert(water_pipes, pipe(0, y_ofs(a), 1, y_ofs(a) + 6, colors.blue, true))
if tank_defs[b] == 2 then
table.insert(water_pipes, pipe(0, y_ofs(b) - 13, 1, y_ofs(b), colors.blue, true))
end
elseif tank_defs[b] == 2 then
table.insert(water_pipes, pipe(0, y_ofs(b), 1, y_ofs(b) + 6, colors.blue, true))
end
end
elseif facility.tank_mode == 4 then
-- (4) 2 total facility tanks (A B B B)
local first_fdef, last_fdef = find_fdef(2, #tank_defs)
for i = 1, #tank_defs do
local y = y_ofs(i)
if i == 1 then
if tank_defs[i] == 2 then
table.insert(water_pipes, pipe(0, y, 1, y + 5, colors.blue, true))
end
elseif i == first_fdef then
table.insert(water_pipes, pipe(0, y, 1, y + 5, colors.blue, true))
elseif i > first_fdef then
if i == last_fdef then
table.insert(water_pipes, pipe(0, y - 14, 0, y, colors.blue, true))
elseif i < last_fdef then
table.insert(water_pipes, pipe(0, y - 14, 0, y + 5, colors.blue, true))
end
end
end
elseif facility.tank_mode == 5 then
-- (5) 3 total facility tanks (A A B C)
local first_fdef, last_fdef = find_fdef(1, math.min(2, #tank_defs))
for i = 1, #tank_defs do
local y = y_ofs(i)
if i == 3 or i == 4 then
if tank_defs[i] == 2 then
table.insert(water_pipes, pipe(0, y, 1, y + 5, colors.blue, true))
end
elseif i == first_fdef then
table.insert(water_pipes, pipe(0, y, 1, y + 5, colors.blue, true))
elseif i > first_fdef then
if i == last_fdef then
table.insert(water_pipes, pipe(0, y - 14, 0, y, colors.blue, true))
elseif i < last_fdef then
table.insert(water_pipes, pipe(0, y - 14, 0, y + 5, colors.blue, true))
end
end
end
elseif facility.tank_mode == 6 then
-- (6) 3 total facility tanks (A B B C)
local first_fdef, last_fdef = find_fdef(2, math.min(3, #tank_defs))
for i = 1, #tank_defs do
local y = y_ofs(i)
if i == 1 or i == 4 then
if tank_defs[i] == 2 then
table.insert(water_pipes, pipe(0, y, 1, y + 5, colors.blue, true))
end
elseif i == first_fdef then
table.insert(water_pipes, pipe(0, y, 1, y + 5, colors.blue, true))
elseif i > first_fdef then
if i == last_fdef then
table.insert(water_pipes, pipe(0, y - 14, 0, y, colors.blue, true))
elseif i < last_fdef then
table.insert(water_pipes, pipe(0, y - 14, 0, y + 5, colors.blue, true))
end
end
end
elseif facility.tank_mode == 7 then
-- (7) 3 total facility tanks (A B C C)
local first_fdef, last_fdef = find_fdef(3, #tank_defs)
for i = 1, #tank_defs do
local y = y_ofs(i)
if i == 1 or i == 2 then
if tank_defs[i] == 2 then
table.insert(water_pipes, pipe(0, y, 1, y + 5, colors.blue, true))
end
elseif i == first_fdef then
table.insert(water_pipes, pipe(0, y, 1, y + 5, colors.blue, true))
elseif i > first_fdef then
if i == last_fdef then
table.insert(water_pipes, pipe(0, y - 14, 0, y, colors.blue, true))
elseif i < last_fdef then
table.insert(water_pipes, pipe(0, y - 14, 0, y + 5, colors.blue, true))
end
end
end
end
end
local flow_x = 3
if #water_pipes > 0 then
flow_x = 25
PipeNetwork{parent=main,x=2,y=3,pipes=water_pipes,bg=colors.lightGray}
end
for i = 1, facility.num_units do
local y_offset = y_ofs(i)
unit_flow(main, flow_x, 5 + y_offset, #water_pipes == 0, units[i])
table.insert(po_pipes, pipe(0, 3 + y_offset, 4, 0, colors.cyan, true, true))
end
PipeNetwork{parent=main,x=139,y=15,pipes=po_pipes,bg=colors.lightGray}
-----------------
-- tank valves --
-----------------
local next_f_id = 1
for i = 1, #tank_defs do
if tank_defs[i] > 0 then
local vy = 3 + y_ofs(i)
TextBox{parent=main,x=12,y=vy,text="\x10\x11",fg_bg=cpair(colors.black,colors.lightGray),width=2,height=1}
local conn = IndicatorLight{parent=main,x=9,y=vy+1,label=util.sprintf("PV%02d-EMC", i * 5),colors=style.ind_grn}
local open = IndicatorLight{parent=main,x=9,y=vy+2,label="OPEN",colors=style.ind_wht}
conn.register(units[i].unit_ps, "V_emc_conn", conn.update)
open.register(units[i].unit_ps, "V_emc_state", open.update)
end
end
-------------------
-- dynamic tanks --
-------------------
for i = 1, #tank_list do
if tank_list[i] > 0 then
local id = "U-" .. i
local f_id = next_f_id
if tank_list[i] == 2 then
id = "F-" .. next_f_id
next_f_id = next_f_id + 1
end
local y_offset = y_ofs(i)
local tank = Div{parent=main,x=3,y=7+y_offset,width=20,height=14}
TextBox{parent=tank,text=" ",height=1,x=1,y=1,fg_bg=cpair(colors.lightGray,colors.gray)}
TextBox{parent=tank,text="DYNAMIC TANK "..id,alignment=TEXT_ALIGN.CENTER,height=1,fg_bg=style.wh_gray}
local tank_box = Rectangle{parent=tank,border=border(1,colors.gray,true),width=20,height=12}
local status = StateIndicator{parent=tank_box,x=3,y=1,states=style.dtank.states,value=1,min_width=14}
TextBox{parent=tank_box,x=2,y=3,text="Fill",height=1,width=10,fg_bg=style.label}
local tank_pcnt = DataIndicator{parent=tank_box,x=10,y=3,label="",format="%5.2f",value=100,unit="%",lu_colors=lu_col,width=8,fg_bg=text_col}
local tank_amnt = DataIndicator{parent=tank_box,x=2,label="",format="%13d",value=0,unit="mB",lu_colors=lu_col,width=16,fg_bg=bw_fg_bg}
TextBox{parent=tank_box,x=2,y=6,text="Water Level",height=1,width=11,fg_bg=style.label}
local level = HorizontalBar{parent=tank_box,x=2,y=7,bar_fg_bg=cpair(colors.blue,colors.gray),height=1,width=16}
TextBox{parent=tank_box,x=2,y=9,text="In/Out Mode",height=1,width=11,fg_bg=style.label}
local can_fill = IndicatorLight{parent=tank_box,x=2,y=10,label="FILL",colors=style.ind_wht}
local can_empty = IndicatorLight{parent=tank_box,x=10,y=10,label="EMPTY",colors=style.ind_wht}
local function _can_fill(mode)
can_fill.update((mode == CONTAINER_MODE.BOTH) or (mode == CONTAINER_MODE.FILL))
end
local function _can_empty(mode)
can_empty.update((mode == CONTAINER_MODE.BOTH) or (mode == CONTAINER_MODE.EMPTY))
end
if tank_list[i] == 1 then
status.register(units[i].tank_ps_tbl[1], "computed_status", status.update)
tank_pcnt.register(units[i].tank_ps_tbl[1], "fill", function (f) tank_pcnt.update(f * 100) end)
tank_amnt.register(units[i].tank_ps_tbl[1], "stored", function (sto) tank_amnt.update(sto.amount) end)
level.register(units[i].tank_ps_tbl[1], "fill", level.update)
can_fill.register(units[i].tank_ps_tbl[1], "container_mode", _can_fill)
can_empty.register(units[i].tank_ps_tbl[1], "container_mode", _can_empty)
else
status.register(facility.tank_ps_tbl[f_id], "computed_status", status.update)
tank_pcnt.register(facility.tank_ps_tbl[f_id], "fill", function (f) tank_pcnt.update(f * 100) end)
tank_amnt.register(facility.tank_ps_tbl[f_id], "stored", function (sto) tank_amnt.update(sto.amount) end)
level.register(facility.tank_ps_tbl[f_id], "fill", level.update)
can_fill.register(facility.tank_ps_tbl[f_id], "container_mode", _can_fill)
can_empty.register(facility.tank_ps_tbl[f_id], "container_mode", _can_empty)
end
end
end
---------
-- SPS --
---------
local sps = Div{parent=main,x=140,y=3,height=12}
TextBox{parent=sps,text=" ",width=24,height=1,x=1,y=1,fg_bg=cpair(colors.lightGray,colors.gray)}
TextBox{parent=sps,text="SPS",alignment=TEXT_ALIGN.CENTER,width=24,height=1,fg_bg=wh_gray}
local sps_box = Rectangle{parent=sps,border=border(1,colors.gray,true),width=24,height=10}
local status = StateIndicator{parent=sps_box,x=5,y=1,states=style.sps.states,value=1,min_width=14}
status.register(facility.sps_ps_tbl[1], "computed_status", status.update)
TextBox{parent=sps_box,x=2,y=3,text="Input Rate",height=1,width=10,fg_bg=style.label}
local sps_in = DataIndicator{parent=sps_box,x=2,label="",format="%15.3f",value=0,unit="mB/t",lu_colors=lu_col,width=20,fg_bg=bw_fg_bg}
sps_in.register(facility.ps, "po_am_rate", sps_in.update)
TextBox{parent=sps_box,x=2,y=6,text="Production Rate",height=1,width=15,fg_bg=style.label}
local sps_rate = DataIndicator{parent=sps_box,x=2,label="",format="%15d",value=0,unit="\xb5B/t",lu_colors=lu_col,width=20,fg_bg=bw_fg_bg}
sps_rate.register(facility.sps_ps_tbl[1], "process_rate", function (r) sps_rate.update(r * 1000) end)
----------------
-- statistics --
----------------
TextBox{parent=main,x=145,y=16,text="PROC. WASTE",alignment=TEXT_ALIGN.CENTER,width=19,height=1,fg_bg=wh_gray}
local pr_waste = Rectangle{parent=main,x=145,y=17,border=border(1,colors.gray,true),width=19,height=5,thin=true,fg_bg=bw_fg_bg}
local pu = DataIndicator{parent=pr_waste,lu_colors=lu_col,label="Pu",unit="mB/t",format="%9.3f",value=0,width=17}
local po = DataIndicator{parent=pr_waste,lu_colors=lu_col,label="Po",unit="mB/t",format="%9.3f",value=0,width=17}
local popl = DataIndicator{parent=pr_waste,lu_colors=lu_col,label="PoPl",unit="mB/t",format="%7.3f",value=0,width=17}
pu.register(facility.ps, "pu_rate", pu.update)
po.register(facility.ps, "po_rate", po.update)
popl.register(facility.ps, "po_pl_rate", popl.update)
TextBox{parent=main,x=145,y=23,text="SPENT WASTE",alignment=TEXT_ALIGN.CENTER,width=19,height=1,fg_bg=wh_gray}
local sp_waste = Rectangle{parent=main,x=145,y=24,border=border(1,colors.gray,true),width=19,height=3,thin=true,fg_bg=bw_fg_bg}
local sum_sp_waste = DataIndicator{parent=sp_waste,lu_colors=lu_col,label="SUM",unit="mB/t",format="%8.3f",value=0,width=17}
sum_sp_waste.register(facility.ps, "spent_waste_rate", sum_sp_waste.update)
end
return init

View File

@@ -73,6 +73,9 @@ local function init(panel, num_units)
local main_monitor = LED{parent=monitors,label="MAIN MONITOR",colors=cpair(colors.green,colors.green_off)}
main_monitor.register(ps, "main_monitor", main_monitor.update)
local flow_monitor = LED{parent=monitors,label="FLOW MONITOR",colors=cpair(colors.green,colors.green_off)}
flow_monitor.register(ps, "flow_monitor", flow_monitor.update)
monitors.line_break()
for i = 1, num_units do

View File

@@ -52,6 +52,8 @@ function pgi.delete_pkt_entry(session_id)
if not success then
log.error(util.c("PGI: failed to delete PKT entry (", result, ")"), true)
end
else
log.debug(util.c("PGI: tried to delete unknown PKT entry ", session_id))
end
end

View File

@@ -68,7 +68,22 @@ style.colors = {
-- { c = colors.brown, hex = 0x7f664c }
}
-- MAIN LAYOUT --
-- COMMON COLOR PAIRS --
style.wh_gray = cpair(colors.white, colors.gray)
style.bw_fg_bg = cpair(colors.black, colors.white)
style.text_colors = cpair(colors.black, colors.lightGray)
style.lu_colors = cpair(colors.gray, colors.gray)
style.hzd_fg_bg = style.wh_gray
style.dis_colors = cpair(colors.white, colors.lightGray)
style.ind_grn = cpair(colors.green, colors.gray)
style.ind_yel = cpair(colors.yellow, colors.gray)
style.ind_red = cpair(colors.red, colors.gray)
style.ind_wht = style.wh_gray
-- UI COMPONENTS --
style.reactor = {
-- reactor states
@@ -206,7 +221,7 @@ style.sps = {
text = "RTU FAULT"
},
{
color = cpair(colors.black, colors.gray),
color = cpair(colors.white, colors.gray),
text = "IDLE"
},
{
@@ -216,6 +231,36 @@ style.sps = {
}
}
style.dtank = {
-- dynamic tank states
states = {
{
color = cpair(colors.black, colors.yellow),
text = "OFF-LINE"
},
{
color = cpair(colors.black, colors.orange),
text = "NOT FORMED"
},
{
color = cpair(colors.black, colors.orange),
text = "RTU FAULT"
},
{
color = cpair(colors.black, colors.green),
text = "ONLINE"
},
{
color = cpair(colors.black, colors.yellow),
text = "LOW FILL"
},
{
color = cpair(colors.black, colors.green),
text = "FILLED"
},
}
}
style.waste = {
-- auto waste processing states
states = {

View File

@@ -7,7 +7,7 @@ local flasher = require("graphics.flasher")
local core = {}
core.version = "1.0.1"
core.version = "1.1.1"
core.flasher = flasher
core.events = events

View File

@@ -20,6 +20,7 @@ local element = {}
---@alias graphics_args graphics_args_generic
---|waiting_args
---|app_button_args
---|checkbox_args
---|hazard_button_args
---|multi_button_args
@@ -71,7 +72,8 @@ function element.new(args, child_offset_x, child_offset_y)
p_window = nil, ---@type table
position = { x = 1, y = 1 }, ---@type coordinate_2d
bounds = { x1 = 1, y1 = 1, x2 = 1, y2 = 1 }, ---@class element_bounds
next_y = 1,
next_y = 1, -- next child y coordinate
next_id = 0, -- next child ID
subscriptions = {},
mt = {}
}
@@ -352,13 +354,14 @@ function element.new(args, child_offset_x, child_offset_y)
local child_element = child.get()
if key == nil then
table.insert(protected.children, child_element)
return #protected.children
else
protected.children[key] = child_element
return key
local id = key ---@type string|integer|nil
if id == nil then
id = self.next_id
self.next_id = self.next_id + 1
end
protected.children[id] = child_element
return id
end
-- remove a child element
@@ -513,19 +516,21 @@ function element.new(args, child_offset_x, child_offset_y)
-- FUNCTION CALLBACKS --
-- handle a monitor touch or mouse click
-- handle a monitor touch or mouse click if this element is visible
---@param event mouse_interaction mouse interaction event
function public.handle_mouse(event)
local x_ini, y_ini = event.initial.x, event.initial.y
if protected.window.isVisible() then
local x_ini, y_ini = event.initial.x, event.initial.y
local ini_in = protected.in_window_bounds(x_ini, y_ini)
local ini_in = protected.in_window_bounds(x_ini, y_ini)
if ini_in then
local event_T = core.events.mouse_transposed(event, self.position.x, self.position.y)
if ini_in then
local event_T = core.events.mouse_transposed(event, self.position.x, self.position.y)
-- handle the mouse event then pass to children
protected.handle_mouse(event_T)
for _, child in pairs(protected.children) do child.handle_mouse(event_T) end
-- handle the mouse event then pass to children
protected.handle_mouse(event_T)
for _, child in pairs(protected.children) do child.handle_mouse(event_T) end
end
end
end

View File

@@ -0,0 +1,130 @@
-- App Button Graphics Element
local tcd = require("scada-common.tcd")
local core = require("graphics.core")
local element = require("graphics.element")
local CLICK_TYPE = core.events.CLICK_TYPE
---@class app_button_args
---@field text string app icon text
---@field title string app title text
---@field callback function function to call on touch
---@field app_fg_bg cpair app icon foreground/background colors
---@field active_fg_bg? cpair foreground/background colors when pressed
---@field parent graphics_element
---@field id? string element id
---@field x? integer 1 if omitted
---@field y? integer auto incremented if omitted
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw
-- new app button
---@param args app_button_args
---@return graphics_element element, element_id id
local function app_button(args)
assert(type(args.text) == "string", "graphics.elements.controls.app: text is a required field")
assert(type(args.title) == "string", "graphics.elements.controls.app: title is a required field")
assert(type(args.callback) == "function", "graphics.elements.controls.app: callback is a required field")
assert(type(args.app_fg_bg) == "table", "graphics.elements.controls.app: app_fg_bg is a required field")
args.height = 4
args.width = 5
-- create new graphics element base object
local e = element.new(args)
-- write app title, centered
e.window.setCursorPos(1, 4)
e.window.setCursorPos(math.floor((e.frame.w - string.len(args.title)) / 2) + 1, 4)
e.window.write(args.title)
-- draw the app button
local function draw()
local fgd = args.app_fg_bg.fgd
local bkg = args.app_fg_bg.bkg
if e.value then
fgd = args.active_fg_bg.fgd
bkg = args.active_fg_bg.bkg
end
-- draw icon
e.window.setCursorPos(1, 1)
e.window.setTextColor(fgd)
e.window.setBackgroundColor(bkg)
e.window.write("\x9f\x83\x83\x83")
e.window.setTextColor(bkg)
e.window.setBackgroundColor(fgd)
e.window.write("\x90")
e.window.setTextColor(fgd)
e.window.setBackgroundColor(bkg)
e.window.setCursorPos(1, 2)
e.window.write("\x95 ")
e.window.setTextColor(bkg)
e.window.setBackgroundColor(fgd)
e.window.write("\x95")
e.window.setCursorPos(1, 3)
e.window.write("\x82\x8f\x8f\x8f\x81")
-- write the icon text
e.window.setCursorPos(3, 2)
e.window.setTextColor(fgd)
e.window.setBackgroundColor(bkg)
e.window.write(args.text)
end
-- draw the app button as pressed (if active_fg_bg set)
local function show_pressed()
if e.enabled and args.active_fg_bg ~= nil then
e.value = true
e.window.setTextColor(args.active_fg_bg.fgd)
e.window.setBackgroundColor(args.active_fg_bg.bkg)
draw()
end
end
-- draw the app button as unpressed (if active_fg_bg set)
local function show_unpressed()
if e.enabled and args.active_fg_bg ~= nil then
e.value = false
e.window.setTextColor(e.fg_bg.fgd)
e.window.setBackgroundColor(e.fg_bg.bkg)
draw()
end
end
-- handle mouse interaction
---@param event mouse_interaction mouse event
function e.handle_mouse(event)
if e.enabled then
if event.type == CLICK_TYPE.TAP then
show_pressed()
-- show as unpressed in 0.25 seconds
if args.active_fg_bg ~= nil then tcd.dispatch(0.25, show_unpressed) end
args.callback()
elseif event.type == CLICK_TYPE.DOWN then
show_pressed()
elseif event.type == CLICK_TYPE.UP then
show_unpressed()
if e.in_frame_bounds(event.current.x, event.current.y) then
args.callback()
end
end
end
end
-- set the value (true simulates pressing the app button)
---@param val boolean new value
function e.set_value(val)
if val then e.handle_mouse(core.events.mouse_generic(core.events.CLICK_TYPE.UP, 1, 1)) end
end
-- initial draw
draw()
return e.complete()
end
return app_button

View File

@@ -14,6 +14,12 @@ local element = require("graphics.element")
---@field y? integer auto incremented if omitted
---@field hidden? boolean true to hide on initial draw
---@class _pipe_map_entry
---@field atr boolean align top right (or bottom left for false)
---@field thin boolean thin pipe or not
---@field fg string foreground blit
---@field bg string background blit
-- new pipe network
---@param args pipenet_args
---@return graphics_element element, element_id id
@@ -44,102 +50,264 @@ local function pipenet(args)
-- create new graphics element base object
local e = element.new(args)
-- draw all pipes
-- determine if there are any thin pipes involved
local any_thin = false
for p = 1, #args.pipes do
local pipe = args.pipes[p] ---@type pipe
any_thin = args.pipes[p].thin
if any_thin then break end
end
local x = 1 + pipe.x1
local y = 1 + pipe.y1
if not any_thin then
-- draw all pipes
for p = 1, #args.pipes do
local pipe = args.pipes[p] ---@type pipe
local x_step = util.trinary(pipe.x1 >= pipe.x2, -1, 1)
local y_step = util.trinary(pipe.y1 >= pipe.y2, -1, 1)
local x = 1 + pipe.x1
local y = 1 + pipe.y1
e.window.setCursorPos(x, y)
local x_step = util.trinary(pipe.x1 >= pipe.x2, -1, 1)
local y_step = util.trinary(pipe.y1 >= pipe.y2, -1, 1)
local c = core.cpair(pipe.color, e.fg_bg.bkg)
if pipe.thin then
x_step = util.trinary(pipe.x1 == pipe.x2, 0, x_step)
y_step = util.trinary(pipe.y1 == pipe.y2, 0, y_step)
end
if pipe.align_tr then
-- cross width then height
for i = 1, pipe.w do
if pipe.thin then
if i == pipe.w then
-- corner
if y_step > 0 then
e.window.blit("\x93", c.blit_bkg, c.blit_fgd)
e.window.setCursorPos(x, y)
local c = core.cpair(pipe.color, e.fg_bg.bkg)
if pipe.align_tr then
-- cross width then height
for i = 1, pipe.w do
if pipe.thin then
if i == pipe.w then
-- corner
if y_step > 0 then
e.window.blit("\x93", c.blit_bkg, c.blit_fgd)
else
e.window.blit("\x8e", c.blit_fgd, c.blit_bkg)
end
else
e.window.blit("\x8e", c.blit_fgd, c.blit_bkg)
e.window.blit("\x8c", c.blit_fgd, c.blit_bkg)
end
else
if i == pipe.w and y_step > 0 then
-- corner
e.window.blit(" ", c.blit_bkg, c.blit_fgd)
else
e.window.blit("\x8f", c.blit_fgd, c.blit_bkg)
end
end
x = x + x_step
e.window.setCursorPos(x, y)
end
-- back up one
x = x - x_step
for _ = 1, pipe.h - 1 do
y = y + y_step
e.window.setCursorPos(x, y)
if pipe.thin then
e.window.blit("\x95", c.blit_bkg, c.blit_fgd)
else
e.window.blit(" ", c.blit_bkg, c.blit_fgd)
end
end
else
-- cross height then width
for i = 1, pipe.h do
if pipe.thin then
if i == pipe.h then
-- corner
if y_step < 0 then
e.window.blit("\x97", c.blit_bkg, c.blit_fgd)
elseif y_step > 0 then
e.window.blit("\x8d", c.blit_fgd, c.blit_bkg)
else
e.window.blit("\x8c", c.blit_fgd, c.blit_bkg)
end
else
e.window.blit("\x95", c.blit_fgd, c.blit_bkg)
end
else
if i == pipe.h and y_step < 0 then
-- corner
e.window.blit("\x83", c.blit_bkg, c.blit_fgd)
else
e.window.blit(" ", c.blit_bkg, c.blit_fgd)
end
end
y = y + y_step
e.window.setCursorPos(x, y)
end
-- back up one
y = y - y_step
for _ = 1, pipe.w - 1 do
x = x + x_step
e.window.setCursorPos(x, y)
if pipe.thin then
e.window.blit("\x8c", c.blit_fgd, c.blit_bkg)
end
else
if i == pipe.w and y_step > 0 then
-- corner
e.window.blit(" ", c.blit_bkg, c.blit_fgd)
else
e.window.blit("\x8f", c.blit_fgd, c.blit_bkg)
end
end
x = x + x_step
e.window.setCursorPos(x, y)
end
-- back up one
x = x - x_step
for _ = 1, pipe.h - 1 do
y = y + y_step
e.window.setCursorPos(x, y)
if pipe.thin then
e.window.blit("\x95", c.blit_bkg, c.blit_fgd)
else
e.window.blit(" ", c.blit_bkg, c.blit_fgd)
end
end
else
-- cross height then width
for i = 1, pipe.h do
if pipe.thin then
if i == pipe.h then
-- corner
if y_step < 0 then
e.window.blit("\x97", c.blit_bkg, c.blit_fgd)
else
e.window.blit("\x8d", c.blit_fgd, c.blit_bkg)
end
else
e.window.blit("\x95", c.blit_fgd, c.blit_bkg)
end
else
if i == pipe.h and y_step < 0 then
-- corner
e.window.blit("\x83", c.blit_bkg, c.blit_fgd)
else
e.window.blit(" ", c.blit_bkg, c.blit_fgd)
end
end
y = y + y_step
e.window.setCursorPos(x, y)
end
end
else
-- build map if using thin pipes, easist way to check adjacent blocks (cannot 'cheat' like with standard width)
local map = {}
-- back up one
y = y - y_step
-- allocate map
for x = 1, args.width do
table.insert(map, {})
for _ = 1, args.height do table.insert(map[x], false) end
end
for _ = 1, pipe.w - 1 do
x = x + x_step
e.window.setCursorPos(x, y)
-- build map
for p = 1, #args.pipes do
local pipe = args.pipes[p] ---@type pipe
if pipe.thin then
e.window.blit("\x8c", c.blit_fgd, c.blit_bkg)
else
e.window.blit("\x83", c.blit_bkg, c.blit_fgd)
local x = 1 + pipe.x1
local y = 1 + pipe.y1
local x_step = util.trinary(pipe.x1 >= pipe.x2, -1, 1)
local y_step = util.trinary(pipe.y1 >= pipe.y2, -1, 1)
local entry = { atr = pipe.align_tr, thin = pipe.thin, fg = colors.toBlit(pipe.color), bg = e.fg_bg.blit_bkg }
if pipe.align_tr then
-- cross width then height
for _ = 1, pipe.w do
map[x][y] = entry
x = x + x_step
end
x = x - x_step -- back up one
for _ = 1, pipe.h do
map[x][y] = entry
y = y + y_step
end
else
-- cross height then width
for _ = 1, pipe.h do
map[x][y] = entry
y = y + y_step
end
y = y - y_step -- back up one
for _ = 1, pipe.w do
map[x][y] = entry
x = x + x_step
end
end
end
-- render
for x = 1, args.width do
for y = 1, args.height do
local entry = map[x][y] ---@type _pipe_map_entry|false
local char
local invert = false
if entry ~= false then
local function check(cx, cy)
return (map[cx] ~= nil) and (map[cx][cy] ~= nil) and (map[cx][cy] ~= false) and (map[cx][cy].fg == entry.fg)
end
if entry.thin then
if check(x - 1, y) then -- if left
if check(x, y - 1) then -- if above
if check(x + 1, y) then -- if right
if check(x, y + 1) then -- if below
char = util.trinary(entry.atr, "\x91", "\x9d")
invert = entry.atr
else -- not below
char = util.trinary(entry.atr, "\x8e", "\x8d")
end
else -- not right
if check(x, y + 1) then -- if below
char = util.trinary(entry.atr, "\x91", "\x95")
invert = entry.atr
else -- not below
char = util.trinary(entry.atr, "\x8e", "\x85")
end
end
elseif check(x, y + 1) then-- not above, if below
if check(x + 1, y) then -- if right
char = util.trinary(entry.atr, "\x93", "\x9c")
invert = entry.atr
else -- not right
char = util.trinary(entry.atr, "\x93", "\x94")
invert = entry.atr
end
else -- not above, not below
char = "\x8c"
end
elseif check(x + 1, y) then -- not left, if right
if check(x, y - 1) then -- if above
if check(x, y + 1) then -- if below
char = util.trinary(entry.atr, "\x95", "\x9d")
invert = entry.atr
else -- not below
char = util.trinary(entry.atr, "\x8a", "\x8d")
end
else -- not above
if check(x, y + 1) then -- if below
char = util.trinary(entry.atr, "\x97", "\x9c")
invert = entry.atr
else -- not below
char = "\x8c"
end
end
else -- not left, not right
char = "\x95"
invert = entry.atr
end
else
if check(x, y - 1) then -- above
-- not below and (if left or right)
if (not check(x, y + 1)) and (check(x - 1, y) or check(x + 1, y)) then
char = util.trinary(entry.atr, "\x8f", " ")
invert = not entry.atr
else -- not below w/ sides only
char = " "
invert = true
end
elseif check(x, y + 1) then -- not above, if below
-- if left or right
if (check(x - 1, y) or check(x + 1, y)) then
char = "\x83"
invert = true
else -- not left or right
char = " "
invert = true
end
else -- not above, not below
char = util.trinary(entry.atr, "\x8f", "\x83")
invert = not entry.atr
end
end
e.window.setCursorPos(x, y)
if invert then
e.window.blit(char, entry.bg, entry.fg)
else
e.window.blit(char, entry.fg, entry.bg)
end
end
end
end
end
return e.complete()

View File

@@ -48,6 +48,7 @@ def make_manifest(size):
"versions" : {
"installer" : get_version("./ccmsi.lua"),
"bootloader" : get_version("./startup.lua"),
"common" : get_version("./scada-common/util.lua", True),
"comms" : get_version("./scada-common/comms.lua", True),
"graphics" : get_version("./graphics/core.lua", True),
"lockbox" : get_version("./lockbox/init.lua", True),

File diff suppressed because one or more lines are too long

View File

@@ -1,35 +0,0 @@
--
-- Core I/O - Pocket Central I/O Management
--
local psil = require("scada-common.psil")
local coreio = {}
---@class pocket_core_io
local io = {
ps = psil.create()
}
---@enum POCKET_LINK_STATE
local LINK_STATE = {
UNLINKED = 0,
SV_LINK_ONLY = 1,
API_LINK_ONLY = 2,
LINKED = 3
}
coreio.LINK_STATE = LINK_STATE
-- get the core PSIL
function coreio.core_ps()
return io.ps
end
-- set network link state
---@param state POCKET_LINK_STATE
function coreio.report_link_state(state)
io.ps.publish("link_state", state)
end
return coreio

106
pocket/iocontrol.lua Normal file
View File

@@ -0,0 +1,106 @@
--
-- I/O Control for Pocket Integration with Supervisor & Coordinator
--
local psil = require("scada-common.psil")
local types = require("scada-common.types")
local ALARM = types.ALARM
local iocontrol = {}
---@class pocket_ioctl
local io = {
ps = psil.create()
}
---@enum POCKET_LINK_STATE
local LINK_STATE = {
UNLINKED = 0,
SV_LINK_ONLY = 1,
API_LINK_ONLY = 2,
LINKED = 3
}
---@enum NAV_PAGE
local NAV_PAGE = {
HOME = 1,
UNITS = 2,
REACTORS = 3,
BOILERS = 4,
TURBINES = 5,
DIAG = 6,
D_ALARMS = 7
}
iocontrol.LINK_STATE = LINK_STATE
iocontrol.NAV_PAGE = NAV_PAGE
-- initialize facility-independent components of pocket iocontrol
---@param comms pocket_comms
function iocontrol.init_core(comms)
---@class pocket_ioctl_diag
io.diag = {}
-- alarm testing
io.diag.tone_test = {
test_1 = function (state) comms.diag__set_alarm_tone(1, state) end,
test_2 = function (state) comms.diag__set_alarm_tone(2, state) end,
test_3 = function (state) comms.diag__set_alarm_tone(3, state) end,
test_4 = function (state) comms.diag__set_alarm_tone(4, state) end,
test_5 = function (state) comms.diag__set_alarm_tone(5, state) end,
test_6 = function (state) comms.diag__set_alarm_tone(6, state) end,
test_7 = function (state) comms.diag__set_alarm_tone(7, state) end,
test_8 = function (state) comms.diag__set_alarm_tone(8, state) end,
stop_tones = function () comms.diag__set_alarm_tone(0, false) end,
test_breach = function (state) comms.diag__set_alarm(ALARM.ContainmentBreach, state) end,
test_rad = function (state) comms.diag__set_alarm(ALARM.ContainmentRadiation, state) end,
test_lost = function (state) comms.diag__set_alarm(ALARM.ReactorLost, state) end,
test_crit = function (state) comms.diag__set_alarm(ALARM.CriticalDamage, state) end,
test_dmg = function (state) comms.diag__set_alarm(ALARM.ReactorDamage, state) end,
test_overtemp = function (state) comms.diag__set_alarm(ALARM.ReactorOverTemp, state) end,
test_hightemp = function (state) comms.diag__set_alarm(ALARM.ReactorHighTemp, state) end,
test_wasteleak = function (state) comms.diag__set_alarm(ALARM.ReactorWasteLeak, state) end,
test_highwaste = function (state) comms.diag__set_alarm(ALARM.ReactorHighWaste, state) end,
test_rps = function (state) comms.diag__set_alarm(ALARM.RPSTransient, state) end,
test_rcs = function (state) comms.diag__set_alarm(ALARM.RCSTransient, state) end,
test_turbinet = function (state) comms.diag__set_alarm(ALARM.TurbineTrip, state) end,
stop_alarms = function () comms.diag__set_alarm(0, false) end,
get_tone_states = function () comms.diag__get_alarm_tones() end,
ready_warn = nil, ---@type graphics_element
tone_buttons = {},
alarm_buttons = {},
tone_indicators = {} -- indicators to update from supervisor tone states
}
---@class pocket_nav
io.nav = {
page = NAV_PAGE.HOME, ---@type NAV_PAGE
sub_pages = { NAV_PAGE.HOME, NAV_PAGE.UNITS, NAV_PAGE.REACTORS, NAV_PAGE.BOILERS, NAV_PAGE.TURBINES, NAV_PAGE.DIAG },
tasks = {}
}
-- add a task to be performed periodically while on a given page
---@param page NAV_PAGE page to add task to
---@param task function function to execute
function io.nav.register_task(page, task)
if io.nav.tasks[page] == nil then io.nav.tasks[page] = {} end
table.insert(io.nav.tasks[page], task)
end
end
-- initialize facility-dependent components of pocket iocontrol
function iocontrol.init_fac() end
-- set network link state
---@param state POCKET_LINK_STATE
function iocontrol.report_link_state(state) io.ps.publish("link_state", state) end
-- get the IO controller database
function iocontrol.get_db() return io end
return iocontrol

View File

@@ -1,16 +1,15 @@
local comms = require("scada-common.comms")
local log = require("scada-common.log")
local util = require("scada-common.util")
local comms = require("scada-common.comms")
local log = require("scada-common.log")
local util = require("scada-common.util")
local coreio = require("pocket.coreio")
local iocontrol = require("pocket.iocontrol")
local PROTOCOL = comms.PROTOCOL
local DEVICE_TYPE = comms.DEVICE_TYPE
local ESTABLISH_ACK = comms.ESTABLISH_ACK
local SCADA_MGMT_TYPE = comms.SCADA_MGMT_TYPE
-- local CAPI_TYPE = comms.CAPI_TYPE
local LINK_STATE = coreio.LINK_STATE
local LINK_STATE = iocontrol.LINK_STATE
local pocket = {}
@@ -79,20 +78,6 @@ function pocket.comms(version, nic, pkt_channel, svr_channel, crd_channel, range
self.api.seq_num = self.api.seq_num + 1
end
-- send a packet to the coordinator API
-----@param msg_type CAPI_TYPE
-----@param msg table
-- local function _send_api(msg_type, msg)
-- local s_pkt = comms.scada_packet()
-- local pkt = comms.capi_packet()
-- pkt.make(msg_type, msg)
-- s_pkt.make(self.api.addr, self.api.seq_num, PROTOCOL.COORD_API, pkt.raw_sendable())
-- nic.transmit(crd_channel, pkt_channel, s_pkt)
-- self.api.seq_num = self.api.seq_num + 1
-- end
-- attempt supervisor connection establishment
local function _send_sv_establish()
_send_sv(SCADA_MGMT_TYPE.ESTABLISH, { comms.version, version, DEVICE_TYPE.PKT })
@@ -147,7 +132,7 @@ function pocket.comms(version, nic, pkt_channel, svr_channel, crd_channel, range
-- attempt to re-link if any of the dependent links aren't active
function public.link_update()
if not self.sv.linked then
coreio.report_link_state(util.trinary(self.api.linked, LINK_STATE.API_LINK_ONLY, LINK_STATE.UNLINKED))
iocontrol.report_link_state(util.trinary(self.api.linked, LINK_STATE.API_LINK_ONLY, LINK_STATE.UNLINKED))
if self.establish_delay_counter <= 0 then
_send_sv_establish()
@@ -156,7 +141,7 @@ function pocket.comms(version, nic, pkt_channel, svr_channel, crd_channel, range
self.establish_delay_counter = self.establish_delay_counter - 1
end
elseif not self.api.linked then
coreio.report_link_state(LINK_STATE.SV_LINK_ONLY)
iocontrol.report_link_state(LINK_STATE.SV_LINK_ONLY)
if self.establish_delay_counter <= 0 then
_send_api_establish()
@@ -166,10 +151,29 @@ function pocket.comms(version, nic, pkt_channel, svr_channel, crd_channel, range
end
else
-- linked, all good!
coreio.report_link_state(LINK_STATE.LINKED)
iocontrol.report_link_state(LINK_STATE.LINKED)
end
end
-- supervisor get active alarm tones
function public.diag__get_alarm_tones()
if self.sv.linked then _send_sv(SCADA_MGMT_TYPE.DIAG_TONE_GET, {}) end
end
-- supervisor test alarm tones by tone
---@param id TONE|0 tone ID, or 0 to stop all
---@param state boolean tone state
function public.diag__set_alarm_tone(id, state)
if self.sv.linked then _send_sv(SCADA_MGMT_TYPE.DIAG_TONE_SET, { id, state }) end
end
-- supervisor test alarm tones by alarm
---@param id ALARM|0 alarm ID, 0 to stop all
---@param state boolean alarm state
function public.diag__set_alarm(id, state)
if self.sv.linked then _send_sv(SCADA_MGMT_TYPE.DIAG_ALARM_SET, { id, state }) end
end
-- parse a packet
---@param side string
---@param sender integer
@@ -205,6 +209,8 @@ function pocket.comms(version, nic, pkt_channel, svr_channel, crd_channel, range
-- handle a packet
---@param packet mgmt_frame|capi_frame|nil
function public.handle_packet(packet)
local diag = iocontrol.get_db().diag
if packet ~= nil then
local l_chan = packet.scada_frame.local_channel()
local r_chan = packet.scada_frame.remote_channel()
@@ -231,47 +237,9 @@ function pocket.comms(version, nic, pkt_channel, svr_channel, crd_channel, range
-- feed watchdog on valid sequence number
api_watchdog.feed()
if protocol == PROTOCOL.COORD_API then
---@cast packet capi_frame
elseif protocol == PROTOCOL.SCADA_MGMT then
if protocol == PROTOCOL.SCADA_MGMT then
---@cast packet mgmt_frame
if packet.type == SCADA_MGMT_TYPE.ESTABLISH then
-- connection with coordinator established
if packet.length == 1 then
local est_ack = packet.data[1]
if est_ack == ESTABLISH_ACK.ALLOW then
log.info("coordinator connection established")
self.establish_delay_counter = 0
self.api.linked = true
self.api.addr = src_addr
if self.sv.linked then
coreio.report_link_state(LINK_STATE.LINKED)
else
coreio.report_link_state(LINK_STATE.API_LINK_ONLY)
end
elseif est_ack == ESTABLISH_ACK.DENY then
if self.api.last_est_ack ~= est_ack then
log.info("coordinator connection denied")
end
elseif est_ack == ESTABLISH_ACK.COLLISION then
if self.api.last_est_ack ~= est_ack then
log.info("coordinator connection denied due to collision")
end
elseif est_ack == ESTABLISH_ACK.BAD_VERSION then
if self.api.last_est_ack ~= est_ack then
log.info("coordinator comms version mismatch")
end
else
log.debug("coordinator SCADA_MGMT establish packet reply unsupported")
end
self.api.last_est_ack = est_ack
else
log.debug("coordinator SCADA_MGMT establish packet length mismatch")
end
elseif self.api.linked then
if self.api.linked then
if packet.type == SCADA_MGMT_TYPE.KEEP_ALIVE then
-- keep alive request received, echo back
if packet.length == 1 then
@@ -298,6 +266,42 @@ function pocket.comms(version, nic, pkt_channel, svr_channel, crd_channel, range
else
log.debug("received unknown SCADA_MGMT packet type " .. packet.type .. " from coordinator")
end
elseif packet.type == SCADA_MGMT_TYPE.ESTABLISH then
-- connection with coordinator established
if packet.length == 1 then
local est_ack = packet.data[1]
if est_ack == ESTABLISH_ACK.ALLOW then
log.info("coordinator connection established")
self.establish_delay_counter = 0
self.api.linked = true
self.api.addr = src_addr
if self.sv.linked then
iocontrol.report_link_state(LINK_STATE.LINKED)
else
iocontrol.report_link_state(LINK_STATE.API_LINK_ONLY)
end
elseif est_ack == ESTABLISH_ACK.DENY then
if self.api.last_est_ack ~= est_ack then
log.info("coordinator connection denied")
end
elseif est_ack == ESTABLISH_ACK.COLLISION then
if self.api.last_est_ack ~= est_ack then
log.info("coordinator connection denied due to collision")
end
elseif est_ack == ESTABLISH_ACK.BAD_VERSION then
if self.api.last_est_ack ~= est_ack then
log.info("coordinator comms version mismatch")
end
else
log.debug("coordinator SCADA_MGMT establish packet reply unsupported")
end
self.api.last_est_ack = est_ack
else
log.debug("coordinator SCADA_MGMT establish packet length mismatch")
end
else
log.debug("discarding coordinator non-link SCADA_MGMT packet before linked")
end
@@ -325,43 +329,7 @@ function pocket.comms(version, nic, pkt_channel, svr_channel, crd_channel, range
-- handle packet
if protocol == PROTOCOL.SCADA_MGMT then
---@cast packet mgmt_frame
if packet.type == SCADA_MGMT_TYPE.ESTABLISH then
-- connection with supervisor established
if packet.length == 1 then
local est_ack = packet.data[1]
if est_ack == ESTABLISH_ACK.ALLOW then
log.info("supervisor connection established")
self.establish_delay_counter = 0
self.sv.linked = true
self.sv.addr = src_addr
if self.api.linked then
coreio.report_link_state(LINK_STATE.LINKED)
else
coreio.report_link_state(LINK_STATE.SV_LINK_ONLY)
end
elseif est_ack == ESTABLISH_ACK.DENY then
if self.sv.last_est_ack ~= est_ack then
log.info("supervisor connection denied")
end
elseif est_ack == ESTABLISH_ACK.COLLISION then
if self.sv.last_est_ack ~= est_ack then
log.info("supervisor connection denied due to collision")
end
elseif est_ack == ESTABLISH_ACK.BAD_VERSION then
if self.sv.last_est_ack ~= est_ack then
log.info("supervisor comms version mismatch")
end
else
log.debug("supervisor SCADA_MGMT establish packet reply unsupported")
end
self.sv.last_est_ack = est_ack
else
log.debug("supervisor SCADA_MGMT establish packet length mismatch")
end
elseif self.sv.linked then
if self.sv.linked then
if packet.type == SCADA_MGMT_TYPE.KEEP_ALIVE then
-- keep alive request received, echo back
if packet.length == 1 then
@@ -385,9 +353,90 @@ function pocket.comms(version, nic, pkt_channel, svr_channel, crd_channel, range
self.sv.r_seq_num = nil
self.sv.addr = comms.BROADCAST
log.info("supervisor server connection closed by remote host")
elseif packet.type == SCADA_MGMT_TYPE.DIAG_TONE_GET then
if packet.length == 8 then
for i = 1, #packet.data do
diag.tone_test.tone_indicators[i].update(packet.data[i] == true)
end
else
log.debug("supervisor SCADA diag alarm states packet length mismatch")
end
elseif packet.type == SCADA_MGMT_TYPE.DIAG_TONE_SET then
if packet.length == 1 and packet.data[1] == false then
diag.tone_test.ready_warn.set_value("testing denied")
log.debug("supervisor SCADA diag tone set failed")
elseif packet.length == 2 and type(packet.data[2]) == "table" then
local ready = packet.data[1]
local states = packet.data[2]
diag.tone_test.ready_warn.set_value(util.trinary(ready, "", "system not ready"))
for i = 1, #states do
if diag.tone_test.tone_buttons[i] ~= nil then
diag.tone_test.tone_buttons[i].set_value(states[i] == true)
diag.tone_test.tone_indicators[i].update(states[i] == true)
end
end
else
log.debug("supervisor SCADA diag tone set packet length/type mismatch")
end
elseif packet.type == SCADA_MGMT_TYPE.DIAG_ALARM_SET then
if packet.length == 1 and packet.data[1] == false then
diag.tone_test.ready_warn.set_value("testing denied")
log.debug("supervisor SCADA diag alarm set failed")
elseif packet.length == 2 and type(packet.data[2]) == "table" then
local ready = packet.data[1]
local states = packet.data[2]
diag.tone_test.ready_warn.set_value(util.trinary(ready, "", "system not ready"))
for i = 1, #states do
if diag.tone_test.alarm_buttons[i] ~= nil then
diag.tone_test.alarm_buttons[i].set_value(states[i] == true)
end
end
else
log.debug("supervisor SCADA diag alarm set packet length/type mismatch")
end
else
log.debug("received unknown SCADA_MGMT packet type " .. packet.type .. " from supervisor")
end
elseif packet.type == SCADA_MGMT_TYPE.ESTABLISH then
-- connection with supervisor established
if packet.length == 1 then
local est_ack = packet.data[1]
if est_ack == ESTABLISH_ACK.ALLOW then
log.info("supervisor connection established")
self.establish_delay_counter = 0
self.sv.linked = true
self.sv.addr = src_addr
if self.api.linked then
iocontrol.report_link_state(LINK_STATE.LINKED)
else
iocontrol.report_link_state(LINK_STATE.SV_LINK_ONLY)
end
elseif est_ack == ESTABLISH_ACK.DENY then
if self.sv.last_est_ack ~= est_ack then
log.info("supervisor connection denied")
end
elseif est_ack == ESTABLISH_ACK.COLLISION then
if self.sv.last_est_ack ~= est_ack then
log.info("supervisor connection denied due to collision")
end
elseif est_ack == ESTABLISH_ACK.BAD_VERSION then
if self.sv.last_est_ack ~= est_ack then
log.info("supervisor comms version mismatch")
end
else
log.debug("supervisor SCADA_MGMT establish packet reply unsupported")
end
self.sv.last_est_ack = est_ack
else
log.debug("supervisor SCADA_MGMT establish packet length mismatch")
end
else
log.debug("discarding supervisor non-link SCADA_MGMT packet before linked")
end

View File

@@ -4,21 +4,21 @@
require("/initenv").init_env()
local crash = require("scada-common.crash")
local log = require("scada-common.log")
local network = require("scada-common.network")
local ppm = require("scada-common.ppm")
local tcd = require("scada-common.tcd")
local util = require("scada-common.util")
local crash = require("scada-common.crash")
local log = require("scada-common.log")
local network = require("scada-common.network")
local ppm = require("scada-common.ppm")
local tcd = require("scada-common.tcd")
local util = require("scada-common.util")
local core = require("graphics.core")
local core = require("graphics.core")
local config = require("pocket.config")
local coreio = require("pocket.coreio")
local pocket = require("pocket.pocket")
local renderer = require("pocket.renderer")
local config = require("pocket.config")
local iocontrol = require("pocket.iocontrol")
local pocket = require("pocket.pocket")
local renderer = require("pocket.renderer")
local POCKET_VERSION = "alpha-v0.5.2"
local POCKET_VERSION = "v0.6.0-alpha"
local println = util.println
local println_ts = util.println_ts
@@ -73,7 +73,7 @@ local function main()
network.init_mac(config.AUTH_KEY)
end
coreio.report_link_state(coreio.LINK_STATE.UNLINKED)
iocontrol.report_link_state(iocontrol.LINK_STATE.UNLINKED)
-- get the communications modem
local modem = ppm.get_wireless_modem()
@@ -104,6 +104,9 @@ local function main()
local MAIN_CLOCK = 0.5
local loop_clock = util.new_clock(MAIN_CLOCK)
-- init I/O control
iocontrol.init_core(pocket_comms)
----------------------------------------
-- start the UI
----------------------------------------
@@ -128,6 +131,9 @@ local function main()
conn_wd.api.feed()
log.debug("startup> conn watchdog started")
local io_db = iocontrol.get_db()
local nav = io_db.nav
-- main event loop
while true do
local event, param1, param2, param3, param4, param5 = util.pull_event()
@@ -140,6 +146,13 @@ local function main()
-- relink if necessary
pocket_comms.link_update()
-- update any tasks for the active page
if (type(nav.tasks[nav.page]) == "table") then
for i = 1, #nav.tasks[nav.page] do
nav.tasks[nav.page][i]()
end
end
loop_clock.start()
elseif conn_wd.sv.is_timer(param1) then
-- supervisor watchdog timeout

View File

@@ -2,17 +2,18 @@
-- Pocket GUI Root
--
local coreio = require("pocket.coreio")
local iocontrol = require("pocket.iocontrol")
local style = require("pocket.ui.style")
local conn_waiting = require("pocket.ui.components.conn_waiting")
local home_page = require("pocket.ui.pages.home_page")
local unit_page = require("pocket.ui.pages.unit_page")
local reactor_page = require("pocket.ui.pages.reactor_page")
local boiler_page = require("pocket.ui.pages.boiler_page")
local diag_page = require("pocket.ui.pages.diag_page")
local home_page = require("pocket.ui.pages.home_page")
local reactor_page = require("pocket.ui.pages.reactor_page")
local turbine_page = require("pocket.ui.pages.turbine_page")
local unit_page = require("pocket.ui.pages.unit_page")
local core = require("graphics.core")
@@ -22,6 +23,9 @@ local TextBox = require("graphics.elements.textbox")
local Sidebar = require("graphics.elements.controls.sidebar")
local LINK_STATE = iocontrol.LINK_STATE
local NAV_PAGE = iocontrol.NAV_PAGE
local TEXT_ALIGN = core.TEXT_ALIGN
local cpair = core.cpair
@@ -29,6 +33,9 @@ local cpair = core.cpair
-- create new main view
---@param main graphics_element main displaybox
local function init(main)
local nav = iocontrol.get_db().nav
local ps = iocontrol.get_db().ps
-- window header message
TextBox{parent=main,y=1,text="",alignment=TEXT_ALIGN.LEFT,height=1,fg_bg=style.header}
@@ -45,10 +52,10 @@ local function init(main)
local root_pane = MultiPane{parent=root_pane_div,x=1,y=1,panes=root_panes}
root_pane.register(coreio.core_ps(), "link_state", function (state)
if state == coreio.LINK_STATE.UNLINKED or state == coreio.LINK_STATE.API_LINK_ONLY then
root_pane.register(ps, "link_state", function (state)
if state == LINK_STATE.UNLINKED or state == LINK_STATE.API_LINK_ONLY then
root_pane.set_value(1)
elseif state == coreio.LINK_STATE.SV_LINK_ONLY then
elseif state == LINK_STATE.SV_LINK_ONLY then
root_pane.set_value(2)
else
root_pane.set_value(3)
@@ -81,19 +88,36 @@ local function init(main)
{
char = "T",
color = cpair(colors.black,colors.white)
},
{
char = "D",
color = cpair(colors.black,colors.orange)
}
}
local pane_1 = home_page(page_div)
local pane_2 = unit_page(page_div)
local pane_3 = reactor_page(page_div)
local pane_4 = boiler_page(page_div)
local pane_5 = turbine_page(page_div)
local panes = { pane_1, pane_2, pane_3, pane_4, pane_5 }
local panes = { home_page(page_div), unit_page(page_div), reactor_page(page_div), boiler_page(page_div), turbine_page(page_div), diag_page(page_div) }
local page_pane = MultiPane{parent=page_div,x=1,y=1,panes=panes}
Sidebar{parent=main_pane,x=1,y=1,tabs=sidebar_tabs,fg_bg=cpair(colors.white,colors.gray),callback=page_pane.set_value}
local function navigate_sidebar(page)
if page == 1 then
nav.page = nav.sub_pages[NAV_PAGE.HOME]
elseif page == 2 then
nav.page = nav.sub_pages[NAV_PAGE.UNITS]
elseif page == 3 then
nav.page = nav.sub_pages[NAV_PAGE.REACTORS]
elseif page == 4 then
nav.page = nav.sub_pages[NAV_PAGE.BOILERS]
elseif page == 5 then
nav.page = nav.sub_pages[NAV_PAGE.TURBINES]
elseif page == 6 then
nav.page = nav.sub_pages[NAV_PAGE.DIAG]
end
page_pane.set_value(page)
end
Sidebar{parent=main_pane,x=1,y=1,tabs=sidebar_tabs,fg_bg=cpair(colors.white,colors.gray),callback=navigate_sidebar}
end
return init

View File

@@ -0,0 +1,147 @@
local iocontrol = require("pocket.iocontrol")
local core = require("graphics.core")
local Div = require("graphics.elements.div")
local MultiPane = require("graphics.elements.multipane")
local TextBox = require("graphics.elements.textbox")
local IndicatorLight = require("graphics.elements.indicators.light")
local App = require("graphics.elements.controls.app")
local Checkbox = require("graphics.elements.controls.checkbox")
local PushButton = require("graphics.elements.controls.push_button")
local SwitchButton = require("graphics.elements.controls.switch_button")
local cpair = core.cpair
local NAV_PAGE = iocontrol.NAV_PAGE
local TEXT_ALIGN = core.TEXT_ALIGN
-- new diagnostics page view
---@param root graphics_element parent
local function new_view(root)
local db = iocontrol.get_db()
local main = Div{parent=root,x=1,y=1}
local diag_home = Div{parent=main,x=1,y=1}
TextBox{parent=diag_home,text="Diagnostic Apps",x=1,y=2,height=1,alignment=TEXT_ALIGN.CENTER}
local alarm_test = Div{parent=main,x=1,y=1}
local panes = { diag_home, alarm_test }
local page_pane = MultiPane{parent=main,x=1,y=1,panes=panes}
local function navigate_diag()
page_pane.set_value(1)
db.nav.page = NAV_PAGE.DIAG
db.nav.sub_pages[NAV_PAGE.DIAG] = NAV_PAGE.DIAG
end
local function navigate_alarm()
page_pane.set_value(2)
db.nav.page = NAV_PAGE.D_ALARMS
db.nav.sub_pages[NAV_PAGE.DIAG] = NAV_PAGE.D_ALARMS
end
------------------------
-- Alarm Testing Page --
------------------------
db.nav.register_task(NAV_PAGE.D_ALARMS, db.diag.tone_test.get_tone_states)
local ttest = db.diag.tone_test
local c_wht_gray = cpair(colors.white, colors.gray)
local c_red_gray = cpair(colors.red, colors.gray)
local c_yel_gray = cpair(colors.yellow, colors.gray)
local c_blue_gray = cpair(colors.blue, colors.gray)
local audio = Div{parent=alarm_test,x=1,y=1}
TextBox{parent=audio,y=1,text="Alarm Sounder Tests",height=1,alignment=TEXT_ALIGN.CENTER}
ttest.ready_warn = TextBox{parent=audio,y=2,text="",height=1,alignment=TEXT_ALIGN.CENTER,fg_bg=cpair(colors.yellow,colors.black)}
PushButton{parent=audio,x=13,y=18,text="\x11 BACK",min_width=8,fg_bg=cpair(colors.black,colors.lightGray),active_fg_bg=c_wht_gray,callback=navigate_diag}
local tones = Div{parent=audio,x=2,y=3,height=10,width=8,fg_bg=cpair(colors.black,colors.yellow)}
TextBox{parent=tones,text="Tones",height=1,alignment=TEXT_ALIGN.CENTER,fg_bg=audio.get_fg_bg()}
local test_btns = {}
test_btns[1] = SwitchButton{parent=tones,text="TEST 1",min_width=8,active_fg_bg=c_wht_gray,callback=ttest.test_1}
test_btns[2] = SwitchButton{parent=tones,text="TEST 2",min_width=8,active_fg_bg=c_wht_gray,callback=ttest.test_2}
test_btns[3] = SwitchButton{parent=tones,text="TEST 3",min_width=8,active_fg_bg=c_wht_gray,callback=ttest.test_3}
test_btns[4] = SwitchButton{parent=tones,text="TEST 4",min_width=8,active_fg_bg=c_wht_gray,callback=ttest.test_4}
test_btns[5] = SwitchButton{parent=tones,text="TEST 5",min_width=8,active_fg_bg=c_wht_gray,callback=ttest.test_5}
test_btns[6] = SwitchButton{parent=tones,text="TEST 6",min_width=8,active_fg_bg=c_wht_gray,callback=ttest.test_6}
test_btns[7] = SwitchButton{parent=tones,text="TEST 7",min_width=8,active_fg_bg=c_wht_gray,callback=ttest.test_7}
test_btns[8] = SwitchButton{parent=tones,text="TEST 8",min_width=8,active_fg_bg=c_wht_gray,callback=ttest.test_8}
ttest.tone_buttons = test_btns
local function stop_all_tones()
for i = 1, #test_btns do test_btns[i].set_value(false) end
ttest.stop_tones()
end
PushButton{parent=tones,text="STOP",min_width=8,active_fg_bg=c_wht_gray,fg_bg=cpair(colors.black,colors.red),callback=stop_all_tones}
local alarms = Div{parent=audio,x=11,y=3,height=15,fg_bg=cpair(colors.lightGray,colors.black)}
TextBox{parent=alarms,text="Alarms (\x13)",height=1,alignment=TEXT_ALIGN.CENTER,fg_bg=audio.get_fg_bg()}
local alarm_btns = {}
alarm_btns[1] = Checkbox{parent=alarms,label="BREACH",min_width=15,box_fg_bg=c_red_gray,callback=ttest.test_breach}
alarm_btns[2] = Checkbox{parent=alarms,label="RADIATION",min_width=15,box_fg_bg=c_red_gray,callback=ttest.test_rad}
alarm_btns[3] = Checkbox{parent=alarms,label="RCT LOST",min_width=15,box_fg_bg=c_red_gray,callback=ttest.test_lost}
alarm_btns[4] = Checkbox{parent=alarms,label="CRIT DAMAGE",min_width=15,box_fg_bg=c_red_gray,callback=ttest.test_crit}
alarm_btns[5] = Checkbox{parent=alarms,label="DAMAGE",min_width=15,box_fg_bg=c_red_gray,callback=ttest.test_dmg}
alarm_btns[6] = Checkbox{parent=alarms,label="OVER TEMP",min_width=15,box_fg_bg=c_red_gray,callback=ttest.test_overtemp}
alarm_btns[7] = Checkbox{parent=alarms,label="HIGH TEMP",min_width=15,box_fg_bg=c_yel_gray,callback=ttest.test_hightemp}
alarm_btns[8] = Checkbox{parent=alarms,label="WASTE LEAK",min_width=15,box_fg_bg=c_red_gray,callback=ttest.test_wasteleak}
alarm_btns[9] = Checkbox{parent=alarms,label="WASTE HIGH",min_width=15,box_fg_bg=c_yel_gray,callback=ttest.test_highwaste}
alarm_btns[10] = Checkbox{parent=alarms,label="RPS TRANS",min_width=15,box_fg_bg=c_yel_gray,callback=ttest.test_rps}
alarm_btns[11] = Checkbox{parent=alarms,label="RCS TRANS",min_width=15,box_fg_bg=c_yel_gray,callback=ttest.test_rcs}
alarm_btns[12] = Checkbox{parent=alarms,label="TURBINE TRP",min_width=15,box_fg_bg=c_red_gray,callback=ttest.test_turbinet}
ttest.alarm_buttons = alarm_btns
local function stop_all_alarms()
for i = 1, #alarm_btns do alarm_btns[i].set_value(false) end
ttest.stop_alarms()
end
PushButton{parent=alarms,x=3,y=15,text="STOP \x13",min_width=8,fg_bg=cpair(colors.black,colors.red),active_fg_bg=c_wht_gray,callback=stop_all_alarms}
local states = Div{parent=audio,x=2,y=14,height=5,width=8}
TextBox{parent=states,text="States",height=1,alignment=TEXT_ALIGN.CENTER}
local t_1 = IndicatorLight{parent=states,label="1",colors=c_blue_gray}
local t_2 = IndicatorLight{parent=states,label="2",colors=c_blue_gray}
local t_3 = IndicatorLight{parent=states,label="3",colors=c_blue_gray}
local t_4 = IndicatorLight{parent=states,label="4",colors=c_blue_gray}
local t_5 = IndicatorLight{parent=states,x=6,y=2,label="5",colors=c_blue_gray}
local t_6 = IndicatorLight{parent=states,x=6,label="6",colors=c_blue_gray}
local t_7 = IndicatorLight{parent=states,x=6,label="7",colors=c_blue_gray}
local t_8 = IndicatorLight{parent=states,x=6,label="8",colors=c_blue_gray}
ttest.tone_indicators = { t_1, t_2, t_3, t_4, t_5, t_6, t_7, t_8 }
--------------
-- App List --
--------------
App{parent=diag_home,x=3,y=4,text="\x0f",title="Alarm",callback=navigate_alarm,app_fg_bg=cpair(colors.black,colors.red),active_fg_bg=cpair(colors.white,colors.gray)}
App{parent=diag_home,x=10,y=4,text="\x1e",title="LoopT",callback=function()end,app_fg_bg=cpair(colors.black,colors.cyan)}
App{parent=diag_home,x=17,y=4,text="@",title="Comps",callback=function()end,app_fg_bg=cpair(colors.black,colors.orange)}
return main
end
return new_view

View File

@@ -1,20 +1,21 @@
-- local style = require("pocket.ui.style")
local core = require("graphics.core")
local core = require("graphics.core")
local Div = require("graphics.elements.div")
local Div = require("graphics.elements.div")
local TextBox = require("graphics.elements.textbox")
local App = require("graphics.elements.controls.app")
-- local cpair = core.cpair
local TEXT_ALIGN = core.TEXT_ALIGN
local cpair = core.cpair
-- new home page view
---@param root graphics_element parent
local function new_view(root)
local main = Div{parent=root,x=1,y=1}
TextBox{parent=main,text="HOME",x=1,y=1,height=1,alignment=TEXT_ALIGN.CENTER}
App{parent=main,x=3,y=2,text="\x17",title="PRC",callback=function()end,app_fg_bg=cpair(colors.black,colors.purple)}
App{parent=main,x=10,y=2,text="\x15",title="CTL",callback=function()end,app_fg_bg=cpair(colors.black,colors.green)}
App{parent=main,x=17,y=2,text="\x08",title="DEV",callback=function()end,app_fg_bg=cpair(colors.black,colors.lightGray)}
App{parent=main,x=3,y=7,text="\x7f",title="Waste",callback=function()end,app_fg_bg=cpair(colors.black,colors.brown)}
App{parent=main,x=10,y=7,text="\xb6",title="Guide",callback=function()end,app_fg_bg=cpair(colors.black,colors.cyan)}
return main
end

View File

@@ -19,7 +19,7 @@ local plc = require("reactor-plc.plc")
local renderer = require("reactor-plc.renderer")
local threads = require("reactor-plc.threads")
local R_PLC_VERSION = "v1.5.5"
local R_PLC_VERSION = "v1.5.6"
local println = util.println
local println_ts = util.println_ts

View File

@@ -165,7 +165,7 @@ function threads.thread__main(smem, init)
local type, device = ppm.handle_unmount(param1)
if type ~= nil and device ~= nil then
if type == "fissionReactorLogicAdapter" then
if device == plc_dev.reactor then
println_ts("reactor disconnected!")
log.error("reactor logic adapter disconnected")
@@ -205,7 +205,7 @@ function threads.thread__main(smem, init)
local type, device = ppm.mount(param1)
if type ~= nil and device ~= nil then
if type == "fissionReactorLogicAdapter" then
if plc_state.no_reactor and (type == "fissionReactorLogicAdapter") then
-- reconnected reactor
plc_dev.reactor = device
plc_state.no_reactor = false

View File

@@ -15,6 +15,10 @@ config.COMMS_TIMEOUT = 5
-- all devices on the same network must use the same key
-- config.AUTH_KEY = "SCADAfacility123"
-- alarm sounder volume (0.0 to 3.0, 1.0 being standard max volume, this is the option given to to speaker.play())
-- note: alarm sine waves are at half saturation, so that multiple will be required to reach full scale
config.SOUNDER_VOLUME = 1.0
-- log path
config.LOG_PATH = "/log.txt"
-- log mode

View File

@@ -37,6 +37,12 @@ function databus.tx_hw_modem(has_modem)
databus.ps.publish("has_modem", has_modem)
end
-- transmit the number of speakers connected
---@param count integer
function databus.tx_hw_spkr_count(count)
databus.ps.publish("speaker_count", count)
end
-- transmit unit hardware type across the bus
---@param uid integer unit ID
---@param type RTU_UNIT_TYPE

View File

@@ -2,36 +2,27 @@
-- RTU Front Panel GUI
--
local types = require("scada-common.types")
local util = require("scada-common.util")
local types = require("scada-common.types")
local util = require("scada-common.util")
local databus = require("rtu.databus")
local databus = require("rtu.databus")
local style = require("rtu.panel.style")
local style = require("rtu.panel.style")
local core = require("graphics.core")
local core = require("graphics.core")
local Div = require("graphics.elements.div")
local TextBox = require("graphics.elements.textbox")
local Div = require("graphics.elements.div")
local TextBox = require("graphics.elements.textbox")
local LED = require("graphics.elements.indicators.led")
local RGBLED = require("graphics.elements.indicators.ledrgb")
local DataIndicator = require("graphics.elements.indicators.data")
local LED = require("graphics.elements.indicators.led")
local RGBLED = require("graphics.elements.indicators.ledrgb")
local TEXT_ALIGN = core.TEXT_ALIGN
local cpair = core.cpair
local UNIT_TYPE_LABELS = {
"UNKNOWN",
"REDSTONE",
"BOILER",
"TURBINE",
"DYNAMIC TANK",
"IND MATRIX",
"SPS",
"SNA",
"ENV DETECTOR"
}
local UNIT_TYPE_LABELS = { "UNKNOWN", "REDSTONE", "BOILER", "TURBINE", "DYNAMIC TANK", "IND MATRIX", "SPS", "SNA", "ENV DETECTOR" }
-- create new front panel view
@@ -72,6 +63,10 @@ local function init(panel, units)
local comp_id = util.sprintf("(%d)", os.getComputerID())
TextBox{parent=system,x=9,y=4,width=6,height=1,text=comp_id,fg_bg=cpair(colors.lightGray,colors.ivory)}
TextBox{parent=system,x=1,y=14,text="SPEAKERS",height=1,width=8,fg_bg=style.label}
local speaker_count = DataIndicator{parent=system,x=10,y=14,label="",format="%3d",value=0,width=3,fg_bg=cpair(colors.gray,colors.white)}
speaker_count.register(databus.ps, "speaker_count", speaker_count.update)
--
-- about label
--

View File

@@ -1,9 +1,11 @@
local audio = require("scada-common.audio")
local comms = require("scada-common.comms")
local ppm = require("scada-common.ppm")
local log = require("scada-common.log")
local types = require("scada-common.types")
local util = require("scada-common.util")
local config = require("rtu.config")
local databus = require("rtu.databus")
local modbus = require("rtu.modbus")
@@ -155,6 +157,48 @@ function rtu.init_unit()
return protected
end
-- create an alarm speaker sounder
---@param speaker table device peripheral
function rtu.init_sounder(speaker)
---@class rtu_speaker_sounder
local spkr_ctl = {
speaker = speaker,
name = ppm.get_iface(speaker),
playing = false,
stream = audio.new_stream(),
play = function () end,
stop = function () end,
continue = function () end
}
-- continue audio stream if playing
function spkr_ctl.continue()
if spkr_ctl.playing then
if spkr_ctl.speaker ~= nil and spkr_ctl.stream.has_next_block() then
local success = spkr_ctl.speaker.playAudio(spkr_ctl.stream.get_next_block(), config.SOUNDER_VOLUME)
if not success then log.error(util.c("rtu_sounder(", spkr_ctl.name, "): error playing audio")) end
end
end
end
-- start audio stream playback
function spkr_ctl.play()
if not spkr_ctl.playing then
spkr_ctl.playing = true
return spkr_ctl.continue()
end
end
-- stop audio stream playback
function spkr_ctl.stop()
spkr_ctl.playing = false
spkr_ctl.speaker.stop()
spkr_ctl.stream.stop()
end
return spkr_ctl
end
-- RTU Communications
---@nodiscard
---@param version string RTU version
@@ -312,7 +356,8 @@ function rtu.comms(version, nic, rtu_channel, svr_channel, range, conn_watchdog)
---@param packet modbus_frame|mgmt_frame
---@param units table RTU units
---@param rtu_state rtu_state
function public.handle_packet(packet, units, rtu_state)
---@param sounders table speaker alarm sounders
function public.handle_packet(packet, units, rtu_state, sounders)
-- print a log message to the terminal as long as the UI isn't running
local function println_ts(message) if not rtu_state.fp_ok then util.println_ts(message) end end
@@ -387,7 +432,49 @@ function rtu.comms(version, nic, rtu_channel, svr_channel, range, conn_watchdog)
elseif protocol == PROTOCOL.SCADA_MGMT then
---@cast packet mgmt_frame
-- SCADA management packet
if packet.type == SCADA_MGMT_TYPE.ESTABLISH then
if rtu_state.linked then
if packet.type == SCADA_MGMT_TYPE.KEEP_ALIVE then
-- keep alive request received, echo back
if packet.length == 1 and type(packet.data[1]) == "number" then
local timestamp = packet.data[1]
local trip_time = util.time() - timestamp
if trip_time > 750 then
log.warning("RTU KEEP_ALIVE trip time > 750ms (" .. trip_time .. "ms)")
end
-- log.debug("RTU RTT = " .. trip_time .. "ms")
_send_keep_alive_ack(timestamp)
else
log.debug("SCADA_MGMT keep alive packet length/type mismatch")
end
elseif packet.type == SCADA_MGMT_TYPE.CLOSE then
-- close connection
conn_watchdog.cancel()
public.unlink(rtu_state)
println_ts("server connection closed by remote host")
log.warning("server connection closed by remote host")
elseif packet.type == SCADA_MGMT_TYPE.RTU_ADVERT then
-- request for capabilities again
public.send_advertisement(units)
elseif packet.type == SCADA_MGMT_TYPE.RTU_TONE_ALARM then
-- alarm tone update from supervisor
if (packet.length == 1) and type(packet.data[1] == "table") and (#packet.data[1] == 8) then
local states = packet.data[1]
for i = 1, #sounders do
local s = sounders[i] ---@type rtu_speaker_sounder
-- set tone states
for id = 1, #states do s.stream.set_active(id, states[id] == true) end
end
end
else
-- not supported
log.debug("received unsupported SCADA_MGMT message type " .. packet.type)
end
elseif packet.type == SCADA_MGMT_TYPE.ESTABLISH then
if packet.length == 1 then
local est_ack = packet.data[1]
@@ -421,36 +508,6 @@ function rtu.comms(version, nic, rtu_channel, svr_channel, range, conn_watchdog)
else
log.debug("SCADA_MGMT establish packet length mismatch")
end
elseif rtu_state.linked then
if packet.type == SCADA_MGMT_TYPE.KEEP_ALIVE then
-- keep alive request received, echo back
if packet.length == 1 and type(packet.data[1]) == "number" then
local timestamp = packet.data[1]
local trip_time = util.time() - timestamp
if trip_time > 750 then
log.warning("RTU KEEP_ALIVE trip time > 750ms (" .. trip_time .. "ms)")
end
-- log.debug("RTU RTT = " .. trip_time .. "ms")
_send_keep_alive_ack(timestamp)
else
log.debug("SCADA_MGMT keep alive packet length/type mismatch")
end
elseif packet.type == SCADA_MGMT_TYPE.CLOSE then
-- close connection
conn_watchdog.cancel()
public.unlink(rtu_state)
println_ts("server connection closed by remote host")
log.warning("server connection closed by remote host")
elseif packet.type == SCADA_MGMT_TYPE.RTU_ADVERT then
-- request for capabilities again
public.send_advertisement(units)
else
-- not supported
log.debug("received unsupported SCADA_MGMT message type " .. packet.type)
end
else
log.debug("discarding non-link SCADA_MGMT packet before linked")
end

View File

@@ -4,6 +4,7 @@
require("/initenv").init_env()
local audio = require("scada-common.audio")
local comms = require("scada-common.comms")
local crash = require("scada-common.crash")
local log = require("scada-common.log")
@@ -30,7 +31,7 @@ local sna_rtu = require("rtu.dev.sna_rtu")
local sps_rtu = require("rtu.dev.sps_rtu")
local turbinev_rtu = require("rtu.dev.turbinev_rtu")
local RTU_VERSION = "v1.5.4"
local RTU_VERSION = "v1.6.0"
local RTU_UNIT_TYPE = types.RTU_UNIT_TYPE
local RTU_UNIT_HW_STATE = databus.RTU_UNIT_HW_STATE
@@ -96,6 +97,9 @@ local function main()
return
end
-- generate alarm tones
audio.generate_tones()
---@class rtu_shared_memory
local __shared_memory = {
-- RTU system state flags
@@ -106,6 +110,11 @@ local function main()
shutdown = false
},
-- RTU gateway devices (not RTU units)
rtu_dev = {
sounders = {}
},
-- system objects
rtu_sys = {
nic = network.nic(modem),
@@ -481,6 +490,18 @@ local function main()
log.info("startup> running in headless mode without front panel")
end
-- find and setup all speakers
local speakers = ppm.get_all_devices("speaker")
for _, s in pairs(speakers) do
local sounder = rtu.init_sounder(s)
table.insert(__shared_memory.rtu_dev.sounders, sounder)
log.debug(util.c("startup> added speaker, attached as ", sounder.name))
end
databus.tx_hw_spkr_count(#__shared_memory.rtu_dev.sounders)
-- start connection watchdog
smem_sys.conn_watchdog = util.new_watchdog(config.COMMS_TIMEOUT)
log.debug("startup> conn watchdog started")

View File

@@ -8,6 +8,7 @@ local util = require("scada-common.util")
local databus = require("rtu.databus")
local modbus = require("rtu.modbus")
local renderer = require("rtu.renderer")
local rtu = require("rtu.rtu")
local boilerv_rtu = require("rtu.dev.boilerv_rtu")
local dynamicv_rtu = require("rtu.dev.dynamicv_rtu")
@@ -24,7 +25,7 @@ local threads = {}
local RTU_UNIT_TYPE = types.RTU_UNIT_TYPE
local UNIT_HW_STATE = databus.RTU_UNIT_HW_STATE
local MAIN_CLOCK = 2 -- (2Hz, 40 ticks)
local MAIN_CLOCK = 0.5 -- (2Hz, 10 ticks)
local COMMS_SLEEP = 100 -- (100ms, 2 ticks)
-- main thread
@@ -47,6 +48,7 @@ function threads.thread__main(smem)
-- load in from shared memory
local rtu_state = smem.rtu_state
local sounders = smem.rtu_dev.sounders
local nic = smem.rtu_sys.nic
local rtu_comms = smem.rtu_sys.rtu_comms
local conn_watchdog = smem.rtu_sys.conn_watchdog
@@ -66,6 +68,15 @@ function threads.thread__main(smem)
-- blink heartbeat indicator
databus.heartbeat()
-- update speaker states
for _, sounder in pairs(sounders) do
-- re-compute output if needed, then play audio if available
if sounder.stream.is_recompute_needed() then
sounder.stream.compute_buffer()
if sounder.stream.has_next_block() then sounder.play() else sounder.stop() end
end
end
-- start next clock timer
loop_clock.start()
@@ -110,6 +121,18 @@ function threads.thread__main(smem)
else
log.warning("non-comms modem disconnected")
end
elseif type == "speaker" then
for i = 1, #sounders do
if sounders[i].speaker == device then
table.remove(sounders, i)
log.warning(util.c("speaker ", param1, " disconnected"))
println_ts("speaker disconnected")
databus.tx_hw_spkr_count(#sounders)
break
end
end
else
for i = 1, #units do
-- find disconnected device
@@ -147,6 +170,13 @@ function threads.thread__main(smem)
else
log.info("wired modem reconnected")
end
elseif type == "speaker" then
table.insert(sounders, rtu.init_sounder(device))
println_ts("speaker connected")
log.info(util.c("connected speaker ", param1))
databus.tx_hw_spkr_count(#sounders)
else
-- relink lost peripheral to correct unit entry
for i = 1, #units do
@@ -252,6 +282,15 @@ function threads.thread__main(smem)
elseif event == "mouse_click" or event == "mouse_up" or event == "mouse_drag" or event == "mouse_scroll" then
-- handle a mouse event
renderer.handle_mouse(core.events.new_mouse_event(event, param1, param2, param3))
elseif event == "speaker_audio_empty" then
-- handle empty speaker audio buffer
for i = 1, #sounders do
local sounder = sounders[i] ---@type rtu_speaker_sounder
if sounder.name == param1 then
sounder.continue()
break
end
end
end
-- check for termination request
@@ -299,6 +338,7 @@ function threads.thread__comms(smem)
-- load in from shared memory
local rtu_state = smem.rtu_state
local sounders = smem.rtu_dev.sounders
local rtu_comms = smem.rtu_sys.rtu_comms
local units = smem.rtu_sys.units
@@ -308,7 +348,9 @@ function threads.thread__comms(smem)
-- thread loop
while true do
-- check for messages in the message queue
local handle_start = util.time()
-- check for messages in the message queue while not shut down
while comms_queue.ready() and not rtu_state.shutdown do
local msg = comms_queue.pop()
@@ -319,15 +361,21 @@ function threads.thread__comms(smem)
-- received data
elseif msg.qtype == mqueue.TYPE.PACKET then
-- received a packet
-- handle the packet (rtu_state passed to allow setting link flag)
rtu_comms.handle_packet(msg.message, units, rtu_state)
-- handle the packet (rtu_state passed to allow setting link flag, sounders passed to manage alarm audio)
rtu_comms.handle_packet(msg.message, units, rtu_state, sounders)
end
end
-- quick yield
util.nop()
-- max 100ms spent processing queue
if util.time() - handle_start > 100 then
log.warning("comms thread exceeded 100ms queue process limit")
break
end
end
-- quick yield
util.nop()
-- check for termination request
if rtu_state.shutdown then
rtu_comms.close(rtu_state)
@@ -414,6 +462,12 @@ function threads.thread__unit_comms(smem, unit)
util.nop()
end
-- check for termination request
if rtu_state.shutdown then
log.info("rtu unit thread exiting -> " .. short_name)
break
end
-- check if multiblock is still formed if this is a multiblock
if unit.is_multiblock and (util.time_ms() - last_f_check > 250) then
local is_formed = unit.device.isFormed()
@@ -507,12 +561,6 @@ function threads.thread__unit_comms(smem, unit)
-- update hw status
databus.tx_unit_hw_status(unit.uid, unit.hw_state)
-- check for termination request
if rtu_state.shutdown then
log.info("rtu unit thread exiting -> " .. short_name)
break
end
-- delay before next check
last_update = util.adaptive_delay(COMMS_SLEEP, last_update)
end

313
scada-common/audio.lua Normal file
View File

@@ -0,0 +1,313 @@
--
-- Audio & Tone Control for Alarms
--
-- sounds modeled after https://www.e2s.com/references-and-guidelines/listen-and-download-alarm-tones
-- note: max samples = 0x20000 (128 * 1024 samples)
local _2_PI = 2 * math.pi -- 2 whole pies, hope you're hungry
local _DRATE = 48000 -- 48kHz audio
local _MAX_VAL = 127 / 2 -- max signed integer in this 8-bit audio
local _05s_SAMPLES = 24000 -- half a second worth of samples
---@class audio
local audio = {}
---@enum TONE
local TONE = {
T_340Hz_Int_2Hz = 1,
T_544Hz_440Hz_Alt = 2,
T_660Hz_Int_125ms = 3,
T_745Hz_Int_1Hz = 4,
T_800Hz_Int = 5,
T_800Hz_1000Hz_Alt = 6,
T_1000Hz_Int = 7,
T_1800Hz_Int_4Hz = 8
}
audio.TONE = TONE
local tone_data = {
{ {}, {}, {}, {} }, -- 340Hz @ 2Hz Intermittent
{ {}, {}, {}, {} }, -- 544Hz 100mS / 440Hz 400mS Alternating
{ {}, {}, {}, {} }, -- 660Hz @ 125ms On 125ms Off
{ {}, {}, {}, {} }, -- 745Hz @ 1Hz Intermittent
{ {}, {}, {}, {} }, -- 800Hz @ 0.25s On 1.75s Off
{ {}, {}, {}, {} }, -- 800/1000Hz @ 0.25s Alternating
{ {}, {}, {}, {} }, -- 1KHz 1s on, 1s off Intermittent
{ {}, {}, {}, {} } -- 1.8KHz @ 4Hz Intermittent
}
-- calculate how many samples are in the given number of milliseconds
---@nodiscard
---@param ms integer milliseconds
---@return integer samples
local function ms_to_samples(ms) return math.floor(ms * 48) end
--#region Tone Generation (the Maths)
-- 340Hz @ 2Hz Intermittent
local function gen_tone_1()
local t, dt = 0, _2_PI * 340 / _DRATE
for i = 1, _05s_SAMPLES do
local val = math.floor(math.sin(t) * _MAX_VAL)
tone_data[1][1][i] = val
tone_data[1][3][i] = val
tone_data[1][2][i] = 0
tone_data[1][4][i] = 0
t = (t + dt) % _2_PI
end
end
-- 544Hz 100mS / 440Hz 400mS Alternating
local function gen_tone_2()
local t1, dt1 = 0, _2_PI * 544 / _DRATE
local t2, dt2 = 0, _2_PI * 440 / _DRATE
local alternate_at = ms_to_samples(100)
for i = 1, _05s_SAMPLES do
local value
if i <= alternate_at then
value = math.floor(math.sin(t1) * _MAX_VAL)
t1 = (t1 + dt1) % _2_PI
else
value = math.floor(math.sin(t2) * _MAX_VAL)
t2 = (t2 + dt2) % _2_PI
end
tone_data[2][1][i] = value
tone_data[2][2][i] = value
tone_data[2][3][i] = value
tone_data[2][4][i] = value
end
end
-- 660Hz @ 125ms On 125ms Off
local function gen_tone_3()
local elapsed_samples = 0
local alternate_after = ms_to_samples(125)
local alternate_at = alternate_after
local mode = true
local t, dt = 0, _2_PI * 660 / _DRATE
for set = 1, 4 do
for i = 1, _05s_SAMPLES do
if mode then
local val = math.floor(math.sin(t) * _MAX_VAL)
tone_data[3][set][i] = val
t = (t + dt) % _2_PI
else
t = 0
tone_data[3][set][i] = 0
end
if elapsed_samples == alternate_at then
mode = not mode
alternate_at = elapsed_samples + alternate_after
end
elapsed_samples = elapsed_samples + 1
end
end
end
-- 745Hz @ 1Hz Intermittent
local function gen_tone_4()
local t, dt = 0, _2_PI * 745 / _DRATE
for i = 1, _05s_SAMPLES do
local val = math.floor(math.sin(t) * _MAX_VAL)
tone_data[4][1][i] = val
tone_data[4][3][i] = val
tone_data[4][2][i] = 0
tone_data[4][4][i] = 0
t = (t + dt) % _2_PI
end
end
-- 800Hz @ 0.25s On 1.75s Off
local function gen_tone_5()
local t, dt = 0, _2_PI * 800 / _DRATE
local stop_at = ms_to_samples(250)
for i = 1, _05s_SAMPLES do
local val = math.floor(math.sin(t) * _MAX_VAL)
if i > stop_at then
tone_data[5][1][i] = val
else
tone_data[5][1][i] = 0
end
tone_data[5][2][i] = 0
tone_data[5][3][i] = 0
tone_data[5][4][i] = 0
t = (t + dt) % _2_PI
end
end
-- 1000/800Hz @ 0.25s Alternating
local function gen_tone_6()
local t1, dt1 = 0, _2_PI * 1000 / _DRATE
local t2, dt2 = 0, _2_PI * 800 / _DRATE
local alternate_at = ms_to_samples(250)
for i = 1, _05s_SAMPLES do
local val
if i <= alternate_at then
val = math.floor(math.sin(t1) * _MAX_VAL)
t1 = (t1 + dt1) % _2_PI
else
val = math.floor(math.sin(t2) * _MAX_VAL)
t2 = (t2 + dt2) % _2_PI
end
tone_data[6][1][i] = val
tone_data[6][2][i] = val
tone_data[6][3][i] = val
tone_data[6][4][i] = val
end
end
-- 1KHz 1s on, 1s off Intermittent
local function gen_tone_7()
local t, dt = 0, _2_PI * 1000 / _DRATE
for i = 1, _05s_SAMPLES do
local val = math.floor(math.sin(t) * _MAX_VAL)
tone_data[7][1][i] = val
tone_data[7][2][i] = val
tone_data[7][3][i] = 0
tone_data[7][4][i] = 0
t = (t + dt) % _2_PI
end
end
-- 1800Hz @ 4Hz Intermittent
local function gen_tone_8()
local t, dt = 0, _2_PI * 1800 / _DRATE
local off_at = ms_to_samples(250)
for i = 1, _05s_SAMPLES do
local val = 0
if i <= off_at then
val = math.floor(math.sin(t) * _MAX_VAL)
t = (t + dt) % _2_PI
end
tone_data[8][1][i] = val
tone_data[8][2][i] = val
tone_data[8][3][i] = val
tone_data[8][4][i] = val
end
end
--#endregion
-- generate all 8 tone sequences
function audio.generate_tones()
gen_tone_1(); gen_tone_2(); gen_tone_3(); gen_tone_4(); gen_tone_5(); gen_tone_6(); gen_tone_7(); gen_tone_8()
end
-- hard audio limiter
---@nodiscard
---@param output number output level
---@return number limited -128.0 to 127.0
local function limit(output)
return math.max(-128, math.min(127, output))
end
-- clear output buffer
---@param buffer table quad buffer
local function clear(buffer)
for i = 1, 4 do
for s = 1, _05s_SAMPLES do buffer[i][s] = 0 end
end
end
-- create a new audio tone stream controller
function audio.new_stream()
local self = {
any_active = false,
need_recompute = false,
next_block = 1,
-- split audio up into 0.5s samples, so specific components can be ended quicker
quad_buffer = { {}, {}, {}, {} },
-- all tone enable states
tone_active = { false, false, false, false, false, false, false, false }
}
clear(self.quad_buffer)
---@class tone_stream
local public = {}
-- add a tone to the output buffer
---@param index TONE tone ID
---@param active boolean active state
function public.set_active(index, active)
if self.tone_active[index] ~= nil then
if self.tone_active[index] ~= active then self.need_recompute = true end
self.tone_active[index] = active
end
end
-- check if a tone is active
---@param index TONE tone index
function public.is_active(index)
if self.tone_active[index] then return self.tone_active[index] end
return false
end
-- set all tones inactive, reset next block, and clear output buffer
function public.stop()
for i = 1, #self.tone_active do self.tone_active[i] = false end
self.next_block = 1
clear(self.quad_buffer)
end
-- check if the output buffer needs to be recomputed due to changes
function public.is_recompute_needed() return self.need_recompute end
-- re-compute the output buffer
function public.compute_buffer()
clear(self.quad_buffer)
self.need_recompute = false
self.any_active = false
for id = 1, #tone_data do
if self.tone_active[id] then
self.any_active = true
for i = 1, 4 do
local buffer = self.quad_buffer[i]
local values = tone_data[id][i]
for s = 1, _05s_SAMPLES do self.quad_buffer[i][s] = limit(buffer[s] + values[s]) end
end
end
end
end
-- check if the next audio block has data
function public.has_next_block() return #self.quad_buffer[self.next_block] > 0 end
-- get the next audio block
function public.get_next_block()
local block = self.quad_buffer[self.next_block]
self.next_block = self.next_block + 1
if self.next_block > 4 then self.next_block = 1 end
return block
end
return public
end
return audio

View File

@@ -14,50 +14,54 @@ local max_distance = nil ---@type number|nil maximum acceptable t
---@class comms
local comms = {}
comms.version = "2.1.2"
comms.version = "2.2.1"
---@enum PROTOCOL
local PROTOCOL = {
MODBUS_TCP = 0, -- our "MODBUS TCP"-esque protocol
RPLC = 1, -- reactor PLC protocol
SCADA_MGMT = 2, -- SCADA supervisor management, device advertisements, etc
SCADA_CRDN = 3, -- data/control packets for coordinators to/from supervisory controllers
COORD_API = 4 -- data/control packets for pocket computers to/from coordinators
MODBUS_TCP = 0, -- our "MODBUS TCP"-esque protocol
RPLC = 1, -- reactor PLC protocol
SCADA_MGMT = 2, -- SCADA supervisor management, device advertisements, etc
SCADA_CRDN = 3, -- data/control packets for coordinators to/from supervisory controllers
COORD_API = 4 -- data/control packets for pocket computers to/from coordinators
}
---@enum RPLC_TYPE
local RPLC_TYPE = {
STATUS = 0, -- reactor/system status
MEK_STRUCT = 1, -- mekanism build structure
MEK_BURN_RATE = 2, -- set burn rate
RPS_ENABLE = 3, -- enable reactor
RPS_SCRAM = 4, -- SCRAM reactor (manual request)
RPS_ASCRAM = 5, -- SCRAM reactor (automatic request)
RPS_STATUS = 6, -- RPS status
RPS_ALARM = 7, -- RPS alarm broadcast
RPS_RESET = 8, -- clear RPS trip (if in bad state, will trip immediately)
RPS_AUTO_RESET = 9, -- clear RPS trip if it is just a timeout or auto scram
AUTO_BURN_RATE = 10 -- set an automatic burn rate, PLC will respond with status, enable toggle speed limited
STATUS = 0, -- reactor/system status
MEK_STRUCT = 1, -- mekanism build structure
MEK_BURN_RATE = 2, -- set burn rate
RPS_ENABLE = 3, -- enable reactor
RPS_SCRAM = 4, -- SCRAM reactor (manual request)
RPS_ASCRAM = 5, -- SCRAM reactor (automatic request)
RPS_STATUS = 6, -- RPS status
RPS_ALARM = 7, -- RPS alarm broadcast
RPS_RESET = 8, -- clear RPS trip (if in bad state, will trip immediately)
RPS_AUTO_RESET = 9, -- clear RPS trip if it is just a timeout or auto scram
AUTO_BURN_RATE = 10 -- set an automatic burn rate, PLC will respond with status, enable toggle speed limited
}
---@enum SCADA_MGMT_TYPE
local SCADA_MGMT_TYPE = {
ESTABLISH = 0, -- establish new connection
KEEP_ALIVE = 1, -- keep alive packet w/ RTT
CLOSE = 2, -- close a connection
RTU_ADVERT = 3, -- RTU capability advertisement
RTU_DEV_REMOUNT = 4 -- RTU multiblock possbily changed (formed, unformed) due to PPM remount
ESTABLISH = 0, -- establish new connection
KEEP_ALIVE = 1, -- keep alive packet w/ RTT
CLOSE = 2, -- close a connection
RTU_ADVERT = 3, -- RTU capability advertisement
RTU_DEV_REMOUNT = 4, -- RTU multiblock possbily changed (formed, unformed) due to PPM remount
RTU_TONE_ALARM = 5, -- instruct RTUs to play specified alarm tones
DIAG_TONE_GET = 6, -- diagnostic: get alarm tones
DIAG_TONE_SET = 7, -- diagnostic: set alarm tones
DIAG_ALARM_SET = 8 -- diagnostic: set alarm to simulate audio for
}
---@enum SCADA_CRDN_TYPE
local SCADA_CRDN_TYPE = {
INITIAL_BUILDS = 0, -- initial, complete builds packet to the coordinator
FAC_BUILDS = 1, -- facility RTU builds
FAC_STATUS = 2, -- state of facility and facility devices
FAC_CMD = 3, -- faility command
UNIT_BUILDS = 4, -- build of each reactor unit (reactor + RTUs)
UNIT_STATUSES = 5, -- state of each of the reactor units
UNIT_CMD = 6 -- command a reactor unit
INITIAL_BUILDS = 0, -- initial, complete builds packet to the coordinator
FAC_BUILDS = 1, -- facility RTU builds
FAC_STATUS = 2, -- state of facility and facility devices
FAC_CMD = 3, -- faility command
UNIT_BUILDS = 4, -- build of each reactor unit (reactor + RTUs)
UNIT_STATUSES = 5, -- state of each of the reactor units
UNIT_CMD = 6 -- command a reactor unit
}
---@enum CAPI_TYPE
@@ -66,50 +70,50 @@ local CAPI_TYPE = {
---@enum ESTABLISH_ACK
local ESTABLISH_ACK = {
ALLOW = 0, -- link approved
DENY = 1, -- link denied
COLLISION = 2, -- link denied due to existing active link
BAD_VERSION = 3 -- link denied due to comms version mismatch
ALLOW = 0, -- link approved
DENY = 1, -- link denied
COLLISION = 2, -- link denied due to existing active link
BAD_VERSION = 3 -- link denied due to comms version mismatch
}
---@enum DEVICE_TYPE
local DEVICE_TYPE = {
PLC = 0, -- PLC device type for establish
RTU = 1, -- RTU device type for establish
SV = 2, -- supervisor device type for establish
CRDN = 3, -- coordinator device type for establish
PKT = 4 -- pocket device type for establish
PLC = 0, -- PLC device type for establish
RTU = 1, -- RTU device type for establish
SV = 2, -- supervisor device type for establish
CRDN = 3, -- coordinator device type for establish
PKT = 4 -- pocket device type for establish
}
---@enum PLC_AUTO_ACK
local PLC_AUTO_ACK = {
FAIL = 0, -- failed to set burn rate/burn rate invalid
DIRECT_SET_OK = 1, -- successfully set burn rate
RAMP_SET_OK = 2, -- successfully started burn rate ramping
ZERO_DIS_OK = 3 -- successfully disabled reactor with < 0.01 burn rate
FAIL = 0, -- failed to set burn rate/burn rate invalid
DIRECT_SET_OK = 1, -- successfully set burn rate
RAMP_SET_OK = 2, -- successfully started burn rate ramping
ZERO_DIS_OK = 3 -- successfully disabled reactor with < 0.01 burn rate
}
---@enum FAC_COMMAND
local FAC_COMMAND = {
SCRAM_ALL = 0, -- SCRAM all reactors
STOP = 1, -- stop automatic process control
START = 2, -- start automatic process control
ACK_ALL_ALARMS = 3, -- acknowledge all alarms on all units
SET_WASTE_MODE = 4, -- set automatic waste processing mode
SET_PU_FB = 5 -- set plutonium fallback mode
SCRAM_ALL = 0, -- SCRAM all reactors
STOP = 1, -- stop automatic process control
START = 2, -- start automatic process control
ACK_ALL_ALARMS = 3, -- acknowledge all alarms on all units
SET_WASTE_MODE = 4, -- set automatic waste processing mode
SET_PU_FB = 5 -- set plutonium fallback mode
}
---@enum UNIT_COMMAND
local UNIT_COMMAND = {
SCRAM = 0, -- SCRAM the reactor
START = 1, -- start the reactor
RESET_RPS = 2, -- reset the RPS
SET_BURN = 3, -- set the burn rate
SET_WASTE = 4, -- set the waste processing mode
ACK_ALL_ALARMS = 5, -- ack all active alarms
ACK_ALARM = 6, -- ack a particular alarm
RESET_ALARM = 7, -- reset a particular alarm
SET_GROUP = 8 -- assign this unit to a group
SCRAM = 0, -- SCRAM the reactor
START = 1, -- start the reactor
RESET_RPS = 2, -- reset the RPS
SET_BURN = 3, -- set the burn rate
SET_WASTE = 4, -- set the waste processing mode
ACK_ALL_ALARMS = 5, -- ack all active alarms
ACK_ALARM = 6, -- ack a particular alarm
RESET_ALARM = 7, -- reset a particular alarm
SET_GROUP = 8 -- assign this unit to a group
}
comms.PROTOCOL = PROTOCOL
@@ -146,6 +150,7 @@ function comms.scada_packet()
local self = {
modem_msg_in = nil, ---@type modem_message|nil
valid = false,
authenticated = false,
raw = {},
src_addr = comms.BROADCAST,
dest_addr = comms.BROADCAST,
@@ -234,6 +239,9 @@ function comms.scada_packet()
return self.valid
end
-- report that this packet has been authenticated (was received with a valid HMAC)
function public.stamp_authenticated() self.authenticated = true end
-- public accessors --
---@nodiscard
@@ -248,6 +256,8 @@ function comms.scada_packet()
---@nodiscard
function public.is_valid() return self.valid end
---@nodiscard
function public.is_authenticated() return self.authenticated end
---@nodiscard
function public.src_addr() return self.src_addr end
@@ -313,7 +323,7 @@ function comms.authd_packet()
self.valid = false
self.raw = self.modem_msg_in.msg
if (type(max_distance) == "number") and (distance > max_distance) then
if (type(max_distance) == "number") and (type(distance) == "number") and (distance > max_distance) then
-- outside of maximum allowable transmission distance
-- log.debug("comms.authd_packet.receive(): discarding packet with distance " .. distance .. " outside of trusted range")
else
@@ -588,7 +598,11 @@ function comms.mgmt_packet()
self.type == SCADA_MGMT_TYPE.CLOSE or
self.type == SCADA_MGMT_TYPE.REMOTE_LINKED or
self.type == SCADA_MGMT_TYPE.RTU_ADVERT or
self.type == SCADA_MGMT_TYPE.RTU_DEV_REMOUNT
self.type == SCADA_MGMT_TYPE.RTU_DEV_REMOUNT or
self.type == SCADA_MGMT_TYPE.RTU_TONE_ALARM or
self.type == SCADA_MGMT_TYPE.DIAG_TONE_GET or
self.type == SCADA_MGMT_TYPE.DIAG_TONE_SET or
self.type == SCADA_MGMT_TYPE.DIAG_ALARM_SET
end
-- make a SCADA management packet

View File

@@ -2,10 +2,12 @@
-- System and Safety Constants
--
---@class scada_constants
local constants = {}
--#region Reactor Protection System (on the PLC) Limits
---@class _rps_constants
local rps = {}
rps.MAX_DAMAGE_PERCENT = 90 -- damage >= 90%
@@ -21,6 +23,7 @@ constants.RPS_LIMITS = rps
--#region Annunciator Limits
---@class _annunciator_constants
local annunc = {}
annunc.RCSFlowLow_H2O = -3.2 -- flow < -3.2 mB/s
@@ -44,6 +47,7 @@ constants.ANNUNCIATOR_LIMITS = annunc
--#region Supervisor Alarm Limits
---@class _alarm_constants
local alarms = {}
-- unit alarms

View File

@@ -6,8 +6,10 @@ local comms = require("scada-common.comms")
local log = require("scada-common.log")
local util = require("scada-common.util")
local core = require("graphics.core")
local has_graphics, core = pcall(require, "graphics.core")
local has_lockbox, lockbox = pcall(require, "lockbox")
---@class crash_handler
local crash = {}
local app = "unknown"
@@ -34,7 +36,8 @@ function crash.handler(error)
log.info(util.c("APPLICATION: ", app))
log.info(util.c("FIRMWARE VERSION: ", ver))
log.info(util.c("COMMS VERSION: ", comms.version))
log.info(util.c("GRAPHICS VERSION: ", core.version))
if has_graphics then log.info(util.c("GRAPHICS VERSION: ", core.version)) end
if has_lockbox then log.info(util.c("LOCKBOX VERSION: ", lockbox.version)) end
log.info("----------------------------------")
log.info(debug.traceback("--- begin debug trace ---", 1))
log.info("--- end debug trace ---")

View File

@@ -4,14 +4,11 @@
local util = require("scada-common.util")
---@class log
---@class logger
local log = {}
---@alias MODE integer
local MODE = {
APPEND = 0,
NEW = 1
}
local MODE = { APPEND = 0, NEW = 1 }
log.MODE = MODE

View File

@@ -4,6 +4,14 @@
local mqueue = {}
---@class queue_item
---@field qtype MQ_TYPE
---@field message any
---@class queue_data
---@field key any
---@field val any
---@enum MQ_TYPE
local TYPE = {
COMMAND = 0,
@@ -13,22 +21,14 @@ local TYPE = {
mqueue.TYPE = TYPE
local insert = table.insert
local remove = table.remove
-- create a new message queue
---@nodiscard
function mqueue.new()
local queue = {}
local insert = table.insert
local remove = table.remove
---@class queue_item
---@field qtype MQ_TYPE
---@field message any
---@class queue_data
---@field key any
---@field val any
---@class mqueue
local public = {}
@@ -48,28 +48,20 @@ function mqueue.new()
-- push a new item onto the queue
---@param qtype MQ_TYPE
---@param message any
local function _push(qtype, message)
insert(queue, { qtype = qtype, message = message })
end
local function _push(qtype, message) insert(queue, { qtype = qtype, message = message }) end
-- push a command onto the queue
---@param message any
function public.push_command(message)
_push(TYPE.COMMAND, message)
end
function public.push_command(message) _push(TYPE.COMMAND, message) end
-- push data onto the queue
---@param key any
---@param value any
function public.push_data(key, value)
_push(TYPE.DATA, { key = key, val = value })
end
function public.push_data(key, value) _push(TYPE.DATA, { key = key, val = value }) end
-- push a packet onto the queue
---@param packet packet|frame
function public.push_packet(packet)
_push(TYPE.PACKET, packet)
end
function public.push_packet(packet) _push(TYPE.PACKET, packet) end
-- get an item off the queue
---@nodiscard
@@ -77,9 +69,7 @@ function mqueue.new()
function public.pop()
if #queue > 0 then
return remove(queue, 1)
else
return nil
end
else return nil end
end
return public

View File

@@ -2,19 +2,21 @@
-- Network Communications
--
local comms = require("scada-common.comms")
local log = require("scada-common.log")
local util = require("scada-common.util")
local md5 = require("lockbox.digest.md5")
local sha256 = require("lockbox.digest.sha2_256")
local pbkdf2 = require("lockbox.kdf.pbkdf2")
local hmac = require("lockbox.mac.hmac")
local stream = require("lockbox.util.stream")
local array = require("lockbox.util.array")
local comms = require("scada-common.comms")
local log = require("scada-common.log")
local util = require("scada-common.util")
---@class scada_net_interface
local network = {}
-- cryptography engine
local c_eng = {
key = nil,
hmac = nil
@@ -212,6 +214,7 @@ function network.nic(modem)
if packet_hmac == computed_hmac then
-- log.debug("crypto.modem.receive: HMAC verified in " .. (util.time_ms() - start) .. "ms")
s_packet.receive(side, sender, reply_to, textutils.unserialize(msg), distance)
s_packet.stamp_authenticated()
else
-- log.debug("crypto.modem.receive: HMAC failed verification in " .. (util.time_ms() - start) .. "ms")
end

View File

@@ -8,15 +8,13 @@ local util = require("scada-common.util")
---@class ppm
local ppm = {}
local ACCESS_FAULT = nil ---@type nil
local UNDEFINED_FIELD = "undefined field"
local ACCESS_FAULT = nil ---@type nil
local UNDEFINED_FIELD = "undefined field"
local VIRTUAL_DEVICE_TYPE = "ppm_vdev"
ppm.ACCESS_FAULT = ACCESS_FAULT
ppm.UNDEFINED_FIELD = UNDEFINED_FIELD
ppm.VIRTUAL_DEVICE_TYPE = VIRTUAL_DEVICE_TYPE
ppm.ACCESS_FAULT = ACCESS_FAULT
ppm.UNDEFINED_FIELD = UNDEFINED_FIELD
ppm.VIRTUAL_DEVICE_TYPE = VIRTUAL_DEVICE_TYPE
----------------------------
-- PRIVATE DATA/FUNCTIONS --
@@ -34,9 +32,9 @@ local ppm_sys = {
mute = false
}
-- wrap peripheral calls with lua protected call as we don't want a disconnect to crash a program<br>
-- also provides peripheral-specific fault checks (auto-clear fault defaults to true)<br>
-- assumes iface is a valid peripheral
-- Wrap peripheral calls with lua protected call as we don't want a disconnect to crash a program.
-- Additionally provides peripheral-specific fault checks (auto-clear fault defaults to true).<br>
-- Note: assumes iface is a valid peripheral.
---@param iface string CC peripheral interface
local function peri_init(iface)
local self = {
@@ -307,16 +305,12 @@ end
-- list all available peripherals
---@nodiscard
---@return table names
function ppm.list_avail()
return peripheral.getNames()
end
function ppm.list_avail() return peripheral.getNames() end
-- list mounted peripherals
---@nodiscard
---@return table mounts
function ppm.list_mounts()
return ppm_sys.mounts
end
function ppm.list_mounts() return ppm_sys.mounts end
-- get a mounted peripheral side/interface by device table
---@nodiscard
@@ -390,9 +384,7 @@ end
-- get the fission reactor (if multiple, returns the first)
---@nodiscard
---@return table|nil reactor function table
function ppm.get_fission_reactor()
return ppm.get_device("fissionReactorLogicAdapter")
end
function ppm.get_fission_reactor() return ppm.get_device("fissionReactorLogicAdapter") end
-- get the wireless modem (if multiple, returns the first)<br>
-- if this is in a CraftOS emulated environment, wired modems will be used instead
@@ -419,9 +411,7 @@ function ppm.get_monitor_list()
local list = {}
for iface, device in pairs(ppm_sys.mounts) do
if device.type == "monitor" then
list[iface] = device
end
if device.type == "monitor" then list[iface] = device end
end
return list

View File

@@ -9,14 +9,12 @@ local psil = {}
-- instantiate a new PSI layer
---@nodiscard
function psil.create()
local self = {
ic = {}
}
local ic = {}
-- allocate a new interconnect field
---@key string data key
local function alloc(key)
self.ic[key] = { subscribers = {}, value = nil }
ic[key] = { subscribers = {}, value = nil }
end
---@class psil
@@ -28,22 +26,22 @@ function psil.create()
---@param func function function to call on change
function public.subscribe(key, func)
-- allocate new key if not found or notify if value is found
if self.ic[key] == nil then
if ic[key] == nil then
alloc(key)
elseif self.ic[key].value ~= nil then
func(self.ic[key].value)
elseif ic[key].value ~= nil then
func(ic[key].value)
end
-- subscribe to key
table.insert(self.ic[key].subscribers, { notify = func })
table.insert(ic[key].subscribers, { notify = func })
end
-- unsubscribe a function from a given key
---@param key string data key
---@param func function function to unsubscribe
function public.unsubscribe(key, func)
if self.ic[key] ~= nil then
util.filter_table(self.ic[key].subscribers, function (s) return s.notify ~= func end)
if ic[key] ~= nil then
util.filter_table(ic[key].subscribers, function (s) return s.notify ~= func end)
end
end
@@ -51,32 +49,32 @@ function psil.create()
---@param key string data key
---@param value any data value
function public.publish(key, value)
if self.ic[key] == nil then alloc(key) end
if ic[key] == nil then alloc(key) end
if self.ic[key].value ~= value then
for i = 1, #self.ic[key].subscribers do
self.ic[key].subscribers[i].notify(value)
if ic[key].value ~= value then
for i = 1, #ic[key].subscribers do
ic[key].subscribers[i].notify(value)
end
end
self.ic[key].value = value
ic[key].value = value
end
-- publish a toggled boolean value to a given key, passing it to all subscribers if it has changed<br>
-- this is intended to be used to toggle boolean indicators such as heartbeats without extra state variables
---@param key string data key
function public.toggle(key)
if self.ic[key] == nil then alloc(key) end
if ic[key] == nil then alloc(key) end
self.ic[key].value = self.ic[key].value == false
ic[key].value = ic[key].value == false
for i = 1, #self.ic[key].subscribers do
self.ic[key].subscribers[i].notify(self.ic[key].value)
for i = 1, #ic[key].subscribers do
ic[key].subscribers[i].notify(ic[key].value)
end
end
-- clear the contents of the interconnect
function public.purge() self.ic = nil end
function public.purge() ic = {} end
return public
end

View File

@@ -123,7 +123,7 @@ function rsio.to_string(port)
if util.is_int(port) and port > 0 and port <= #names then
return names[port]
else
return ""
return "UNKNOWN"
end
end

View File

@@ -68,7 +68,7 @@ function tcd.handle(event)
end
end
-- identify any overdo callbacks<br>
-- identify any overdue callbacks<br>
-- prints to log debug output
function tcd.diagnostics()
for timer, entry in pairs(registry) do

View File

@@ -7,6 +7,9 @@ local cc_strings = require("cc.strings")
---@class util
local util = {}
-- scada-common version
util.version = "1.0.1"
-- ENVIRONMENT CONSTANTS --
util.TICK_TIME_S = 0.05
@@ -80,9 +83,9 @@ end
---@return string
function util.strrep(str, n)
local repeated = ""
for _ = 1, n do
repeated = repeated .. str
end
for _ = 1, n do repeated = repeated .. str end
return repeated
end
@@ -123,7 +126,9 @@ function util.strwrap(str, limit) return cc_strings.wrap(str, limit) end
---@diagnostic disable-next-line: unused-vararg
function util.concat(...)
local str = ""
for _, v in ipairs(arg) do str = str .. util.strval(v) end
return str
end
@@ -322,7 +327,8 @@ end
--- EVENT_CONSUMER: this function consumes events
function util.nop() util.psleep(0.05) end
-- attempt to maintain a minimum loop timing (duration of execution)
-- attempt to maintain a minimum loop timing (duration of execution)<br>
-- note: will not yield for time periods less than 50ms
---@nodiscard
---@param target_timing integer minimum amount of milliseconds to wait for
---@param last_update integer millisecond time of last update
@@ -399,7 +405,7 @@ local function GFE(fe) return fe / 1000000000.0 end
local function TFE(fe) return fe / 1000000000000.0 end
local function PFE(fe) return fe / 1000000000000000.0 end
local function EFE(fe) return fe / 1000000000000000000.0 end -- if you accomplish this please touch grass
local function ZFE(fe) return fe / 1000000000000000000000.0 end -- please stop
local function ZFE(fe) return fe / 1000000000000000000000.0 end -- how & why did you do this?
-- format a power value into XXX.XX UNIT format (FE, kFE, MFE, GFE, TFE, PFE, EFE, ZFE)
---@nodiscard

View File

@@ -10,27 +10,39 @@ config.RTU_CHANNEL = 16242
config.CRD_CHANNEL = 16243
-- pocket comms channel
config.PKT_CHANNEL = 16244
-- max trusted modem message distance (0 to disable check)
-- max trusted modem message distance
-- (0 to disable check)
config.TRUSTED_RANGE = 0
-- time in seconds (>= 2) before assuming a remote device is no longer active
-- time in seconds (>= 2) before assuming a remote
-- device is no longer active
config.PLC_TIMEOUT = 5
config.RTU_TIMEOUT = 5
config.CRD_TIMEOUT = 5
config.PKT_TIMEOUT = 5
-- facility authentication key (do NOT use one of your passwords)
-- facility authentication key
-- (do NOT use one of your passwords)
-- this enables verifying that messages are authentic
-- all devices on the same network must use the same key
-- all devices on this network must use this key
-- config.AUTH_KEY = "SCADAfacility123"
-- expected number of reactors
config.NUM_REACTORS = 4
-- expected number of boilers/turbines for each reactor
-- expected number of devices for each unit
config.REACTOR_COOLING = {
{ BOILERS = 1, TURBINES = 1 }, -- reactor unit 1
{ BOILERS = 1, TURBINES = 1 }, -- reactor unit 2
{ BOILERS = 1, TURBINES = 1 }, -- reactor unit 3
{ BOILERS = 1, TURBINES = 1 } -- reactor unit 4
-- reactor unit 1
{ BOILERS = 1, TURBINES = 1, TANK = false },
-- reactor unit 2
{ BOILERS = 1, TURBINES = 1, TANK = false },
-- reactor unit 3
{ BOILERS = 1, TURBINES = 1, TANK = false },
-- reactor unit 4
{ BOILERS = 1, TURBINES = 1, TANK = false }
}
-- advanced facility dynamic tank configuration
-- (see wiki for details)
-- by default, dynamic tanks are for each unit
config.FAC_TANK_MODE = 0
config.FAC_TANK_DEFS = { 0, 0, 0, 0 }
-- log path
config.LOG_PATH = "/log.txt"

View File

@@ -1,22 +1,32 @@
local const = require("scada-common.constants")
local log = require("scada-common.log")
local rsio = require("scada-common.rsio")
local types = require("scada-common.types")
local util = require("scada-common.util")
local audio = require("scada-common.audio")
local const = require("scada-common.constants")
local log = require("scada-common.log")
local rsio = require("scada-common.rsio")
local types = require("scada-common.types")
local util = require("scada-common.util")
local unit = require("supervisor.unit")
local unit = require("supervisor.unit")
local rsctl = require("supervisor.session.rsctl")
local qtypes = require("supervisor.session.rtu.qtypes")
local PROCESS = types.PROCESS
local PROCESS_NAMES = types.PROCESS_NAMES
local PRIO = types.ALARM_PRIORITY
local RTU_UNIT_TYPE = types.RTU_UNIT_TYPE
local WASTE = types.WASTE_PRODUCT
local WASTE_MODE = types.WASTE_MODE
local rsctl = require("supervisor.session.rsctl")
local TONE = audio.TONE
local ALARM = types.ALARM
local PRIO = types.ALARM_PRIORITY
local ALARM_STATE = types.ALARM_STATE
local CONTAINER_MODE = types.CONTAINER_MODE
local PROCESS = types.PROCESS
local PROCESS_NAMES = types.PROCESS_NAMES
local RTU_UNIT_TYPE = types.RTU_UNIT_TYPE
local WASTE_MODE = types.WASTE_MODE
local WASTE = types.WASTE_PRODUCT
local IO = rsio.IO
local DTV_RTU_S_DATA = qtypes.DTV_RTU_S_DATA
-- 7.14 kJ per blade for 1 mB of fissile fuel<br>
-- 2856 FE per blade per 1 mB, 285.6 FE per blade per 0.1 mB (minimum)
local POWER_PER_BLADE = util.joules_to_fe(7140)
@@ -54,12 +64,13 @@ local facility = {}
-- create a new facility management object
---@nodiscard
---@param num_reactors integer number of reactor units
---@param cooling_conf table cooling configurations of reactor units
---@param cooling_conf sv_cooling_conf cooling configurations of reactor units
function facility.new(num_reactors, cooling_conf)
local self = {
units = {},
status_text = { "START UP", "initializing..." },
all_sys_ok = false,
allow_testing = false,
-- rtus
rtu_conn_count = 0,
rtu_list = {},
@@ -109,6 +120,12 @@ function facility.new(num_reactors, cooling_conf)
waste_product = WASTE.PLUTONIUM,
current_waste_product = WASTE.PLUTONIUM,
pu_fallback = false,
-- alarm tones
tone_states = {},
test_tone_set = false,
test_tone_reset = false,
test_tone_states = {},
test_alarm_states = {},
-- statistics
im_stat_init = false,
avg_charge = util.mov_avg(3, 0.0),
@@ -118,7 +135,7 @@ function facility.new(num_reactors, cooling_conf)
-- create units
for i = 1, num_reactors do
table.insert(self.units, unit.new(i, cooling_conf[i].BOILERS, cooling_conf[i].TURBINES))
table.insert(self.units, unit.new(i, cooling_conf.r_cool[i].BOILERS, cooling_conf.r_cool[i].TURBINES))
table.insert(self.group_map, 0)
end
@@ -128,6 +145,13 @@ function facility.new(num_reactors, cooling_conf)
-- init redstone RTU I/O controller
self.io_ctl = rsctl.new(self.redstone)
-- fill blank alarm/tone states
for _ = 1, 12 do table.insert(self.test_alarm_states, false) end
for _ = 1, 8 do
table.insert(self.tone_states, false)
table.insert(self.test_tone_states, false)
end
-- check if all auto-controlled units completed ramping
---@nodiscard
local function _all_units_ramped()
@@ -262,15 +286,20 @@ function facility.new(num_reactors, cooling_conf)
-- supervisor sessions reporting the list of active RTU sessions
---@param rtu_sessions table session list of all connected RTUs
function public.report_rtus(rtu_sessions)
self.rtu_conn_count = #rtu_sessions
end
function public.report_rtus(rtu_sessions) self.rtu_conn_count = #rtu_sessions end
-- update (iterate) the facility management
function public.update()
-- unlink RTU unit sessions if they are closed
for _, v in pairs(self.rtu_list) do util.filter_table(v, function (u) return u.is_connected() end) end
-- check if test routines are allowed right now
self.allow_testing = true
for i = 1, #self.units do
local u = self.units[i] ---@type reactor_unit
self.allow_testing = self.allow_testing and u.is_safe_idle()
end
-- current state for process control
local charge_update = 0
local rate_update = 0
@@ -732,24 +761,138 @@ function facility.new(num_reactors, cooling_conf)
self.io_ctl.digital_write(IO.F_ALARM, has_alarm)
end
-----------------------------
-- Update Waste Processing --
-----------------------------
----------------
-- Unit Tasks --
----------------
local insufficent_po_rate = false
local need_emcool = false
for i = 1, #self.units do
local u = self.units[i] ---@type reactor_unit
-- update auto waste processing
if u.get_control_inf().waste_mode == WASTE_MODE.AUTO then
if (u.get_sna_rate() * 10.0) < u.get_burn_rate() then
insufficent_po_rate = true
break
end
end
-- check if unit activated emergency coolant & uses facility tanks
if (cooling_conf.fac_tank_mode > 0) and u.is_emer_cool_tripped() and (cooling_conf.fac_tank_defs[i] == 2) then
need_emcool = true
end
end
-- update waste product
if self.waste_product == WASTE.PLUTONIUM or (self.pu_fallback and insufficent_po_rate) then
self.current_waste_product = WASTE.PLUTONIUM
else self.current_waste_product = self.waste_product end
-- make sure dynamic tanks are allowing outflow if required
-- set all, rather than trying to determine which is for which (simpler & safer)
-- there should be no need for any to be in fill only mode
if need_emcool then
for i = 1, #self.tanks do
local session = self.tanks[i] ---@type unit_session
local tank = session.get_db() ---@type dynamicv_session_db
if tank.state.container_mode == CONTAINER_MODE.FILL then
session.get_cmd_queue().push_data(DTV_RTU_S_DATA.SET_CONT_MODE, CONTAINER_MODE.BOTH)
end
end
end
if self.waste_product == WASTE.PLUTONIUM or (self.pu_fallback and insufficent_po_rate) then
self.current_waste_product = WASTE.PLUTONIUM
else self.current_waste_product = self.waste_product end
------------------------
-- Update Alarm Tones --
------------------------
local allow_test = self.allow_testing and self.test_tone_set
local alarms = { false, false, false, false, false, false, false, false, false, false, false, false }
-- reset tone states before re-evaluting
for i = 1, #self.tone_states do self.tone_states[i] = false end
if allow_test then
alarms = self.test_alarm_states
else
-- check all alarms for all units
for i = 1, #self.units do
local u = self.units[i] ---@type reactor_unit
for id, alarm in pairs(u.get_alarms()) do
alarms[id] = alarms[id] or (alarm == ALARM_STATE.TRIPPED)
end
end
if not self.test_tone_reset then
-- clear testing alarms if we aren't using them
for i = 1, #self.test_alarm_states do self.test_alarm_states[i] = false end
end
end
-- Evaluate Alarms --
-- containment breach is worst case CRITICAL alarm, this takes priority
if alarms[ALARM.ContainmentBreach] then
self.tone_states[TONE.T_1800Hz_Int_4Hz] = true
else
-- critical damage is highest priority CRITICAL level alarm
if alarms[ALARM.CriticalDamage] then
self.tone_states[TONE.T_660Hz_Int_125ms] = true
else
-- EMERGENCY level alarms + URGENT over temp
if alarms[ALARM.ReactorDamage] or alarms[ALARM.ReactorOverTemp] or alarms[ALARM.ReactorWasteLeak] then
self.tone_states[TONE.T_544Hz_440Hz_Alt] = true
-- URGENT level turbine trip
elseif alarms[ALARM.TurbineTrip] then
self.tone_states[TONE.T_745Hz_Int_1Hz] = true
-- URGENT level reactor lost
elseif alarms[ALARM.ReactorLost] then
self.tone_states[TONE.T_340Hz_Int_2Hz] = true
-- TIMELY level alarms
elseif alarms[ALARM.ReactorHighTemp] or alarms[ALARM.ReactorHighWaste] or alarms[ALARM.RCSTransient] then
self.tone_states[TONE.T_800Hz_Int] = true
end
end
-- check RPS transient URGENT level alarm
if alarms[ALARM.RPSTransient] then
self.tone_states[TONE.T_1000Hz_Int] = true
-- disable really painful audio combination
self.tone_states[TONE.T_340Hz_Int_2Hz] = false
end
end
-- radiation is a big concern, always play this CRITICAL level alarm if active
if alarms[ALARM.ContainmentRadiation] then
self.tone_states[TONE.T_800Hz_1000Hz_Alt] = true
-- we are going to disable the RPS trip alarm audio due to conflict, and if it was enabled
-- then we can re-enable the reactor lost alarm audio since it doesn't painfully combine with this one
if self.tone_states[TONE.T_1000Hz_Int] and alarms[ALARM.ReactorLost] then self.tone_states[TONE.T_340Hz_Int_2Hz] = true end
-- it sounds *really* bad if this is in conjunction with these other tones, so disable them
self.tone_states[TONE.T_745Hz_Int_1Hz] = false
self.tone_states[TONE.T_800Hz_Int] = false
self.tone_states[TONE.T_1000Hz_Int] = false
end
-- add to tone states if testing is active
if allow_test then
for i = 1, #self.tone_states do
self.tone_states[i] = self.tone_states[i] or self.test_tone_states[i]
end
self.test_tone_reset = false
else
if not self.test_tone_reset then
-- clear testing tones if we aren't using them
for i = 1, #self.test_tone_states do self.test_tone_states[i] = false end
end
-- flag that tones were reset
self.test_tone_set = false
self.test_tone_reset = true
end
end
-- call the update function of all units in the facility<br>
@@ -891,8 +1034,52 @@ function facility.new(num_reactors, cooling_conf)
return self.pu_fallback
end
-- DIAGNOSTIC TESTING --
-- attempt to set a test tone state
---@param id TONE|0 tone ID or 0 to disable all
---@param state boolean state
---@return boolean allow_testing, table test_tone_states
function public.diag_set_test_tone(id, state)
if self.allow_testing then
self.test_tone_set = true
self.test_tone_reset = false
if id == 0 then
for i = 1, #self.test_tone_states do self.test_tone_states[i] = false end
else
self.test_tone_states[id] = state
end
end
return self.allow_testing, self.test_tone_states
end
-- attempt to set a test alarm state
---@param id ALARM|0 alarm ID or 0 to disable all
---@param state boolean state
---@return boolean allow_testing, table test_alarm_states
function public.diag_set_test_alarm(id, state)
if self.allow_testing then
self.test_tone_set = true
self.test_tone_reset = false
if id == 0 then
for i = 1, #self.test_alarm_states do self.test_alarm_states[i] = false end
else
self.test_alarm_states[id] = state
end
end
return self.allow_testing, self.test_alarm_states
end
-- READ STATES/PROPERTIES --
-- get current alarm tone on/off states
---@nodiscard
function public.get_alarm_tones() return self.tone_states end
-- get build properties of all facility devices
---@nodiscard
---@param type RTU_UNIT_TYPE? type or nil to include only a particular unit type, or to include all if nil

View File

@@ -60,6 +60,8 @@ function pgi.delete_rtu_entry(session_id)
if not success then
log.error(util.c("PGI: failed to delete RTU entry (", result, ")"), true)
end
else
log.debug(util.c("PGI: tried to delete unknown RTU entry ", session_id))
end
end
@@ -87,6 +89,8 @@ function pgi.delete_pdg_entry(session_id)
if not success then
log.error(util.c("PGI: failed to delete PDG entry (", result, ")"), true)
end
else
log.debug(util.c("PGI: tried to delete unknown PDG entry ", session_id))
end
end

View File

@@ -17,6 +17,9 @@ local FAC_COMMAND = comms.FAC_COMMAND
local SV_Q_DATA = svqtypes.SV_Q_DATA
-- grace period in seconds for coordinator to finish UI draw to prevent timeout
local WATCHDOG_GRACE = 20.0
-- retry time constants in ms
-- local INITIAL_WAIT = 1500
local RETRY_PERIOD = 1000
@@ -61,6 +64,7 @@ function coordinator.new_session(id, s_addr, in_queue, out_queue, timeout, facil
r_seq_num = nil,
connected = true,
conn_watchdog = util.new_watchdog(timeout),
establish_time = util.time_s(),
last_rtt = 0,
-- periodic messages
periodics = {
@@ -150,7 +154,8 @@ function coordinator.new_session(id, s_addr, in_queue, out_queue, timeout, facil
local function _send_fac_status()
local status = {
facility.get_control_status(),
facility.get_rtu_statuses()
facility.get_rtu_statuses(),
facility.get_alarm_tones()
}
_send(SCADA_CRDN_TYPE.FAC_STATUS, status)
@@ -168,7 +173,8 @@ function coordinator.new_session(id, s_addr, in_queue, out_queue, timeout, facil
unit.get_rtu_statuses(),
unit.get_annunciator(),
unit.get_alarms(),
unit.get_state()
unit.get_state(),
unit.get_valves()
}
end
@@ -354,7 +360,15 @@ function coordinator.new_session(id, s_addr, in_queue, out_queue, timeout, facil
-- check if a timer matches this session's watchdog
---@nodiscard
function public.check_wd(timer)
return self.conn_watchdog.is_timer(timer) and self.connected
local is_wd = self.conn_watchdog.is_timer(timer) and self.connected
-- if we are waiting for initial coordinator UI draw, don't close yet
if is_wd and (util.time_s() - self.establish_time) <= WATCHDOG_GRACE then
self.conn_watchdog.feed()
is_wd = false
end
return is_wd
end
-- close the connection

View File

@@ -33,8 +33,9 @@ local PERIODICS = {
---@param in_queue mqueue in message queue
---@param out_queue mqueue out message queue
---@param timeout number communications timeout
---@param facility facility facility data table
---@param fp_ok boolean if the front panel UI is running
function pocket.new_session(id, s_addr, in_queue, out_queue, timeout, fp_ok)
function pocket.new_session(id, s_addr, in_queue, out_queue, timeout, facility, fp_ok)
-- print a log message to the terminal as long as the UI isn't running
local function println(message) if not fp_ok then util.println_ts(message) end end
@@ -129,6 +130,55 @@ function pocket.new_session(id, s_addr, in_queue, out_queue, timeout, fp_ok)
elseif pkt.type == SCADA_MGMT_TYPE.CLOSE then
-- close the session
_close()
elseif pkt.type == SCADA_MGMT_TYPE.DIAG_TONE_GET then
-- get the state of alarm tones
_send_mgmt(SCADA_MGMT_TYPE.DIAG_TONE_GET, facility.get_alarm_tones())
elseif pkt.type == SCADA_MGMT_TYPE.DIAG_TONE_SET then
local valid = false
-- attempt to set a tone state
if pkt.scada_frame.is_authenticated() then
if pkt.length == 2 then
if type(pkt.data[1]) == "number" and type(pkt.data[2]) == "boolean" then
valid = true
-- try to set tone states, then send back if testing is allowed
local allow_testing, test_tone_states = facility.diag_set_test_tone(pkt.data[1], pkt.data[2])
_send_mgmt(SCADA_MGMT_TYPE.DIAG_TONE_SET, { allow_testing, test_tone_states })
else
log.debug(log_header .. "SCADA diag tone set packet data type mismatch")
end
else
log.debug(log_header .. "SCADA diag tone set packet length mismatch")
end
else
log.debug(log_header .. "DIAG_TONE_SET is blocked without HMAC for security")
end
if not valid then _send_mgmt(SCADA_MGMT_TYPE.DIAG_TONE_SET, { false }) end
elseif pkt.type == SCADA_MGMT_TYPE.DIAG_ALARM_SET then
local valid = false
-- attempt to set an alarm state
if pkt.scada_frame.is_authenticated() then
if pkt.length == 2 then
if type(pkt.data[1]) == "number" and type(pkt.data[2]) == "boolean" then
valid = true
-- try to set alarm states, then send back if testing is allowed
local allow_testing, test_alarm_states = facility.diag_set_test_alarm(pkt.data[1], pkt.data[2])
_send_mgmt(SCADA_MGMT_TYPE.DIAG_ALARM_SET, { allow_testing, test_alarm_states })
else
log.debug(log_header .. "SCADA diag alarm set packet data type mismatch")
end
else
log.debug(log_header .. "SCADA diag alarm set packet length mismatch")
end
else
log.debug(log_header .. "DIAG_ALARM_SET is blocked without HMAC for security")
end
if not valid then _send_mgmt(SCADA_MGMT_TYPE.DIAG_ALARM_SET, { false }) end
else
log.debug(log_header .. "handler received unsupported SCADA_MGMT packet type " .. pkt.type)
end

View File

@@ -11,6 +11,18 @@ function rsctl.new(redstone_rtus)
---@class rs_controller
local public = {}
-- check if a redstone port has available connections
---@param port IO_PORT
---@return boolean
function public.is_connected(port)
for i = 1, #redstone_rtus do
local db = redstone_rtus[i].get_db() ---@type redstone_session_db
if db.io[port] ~= nil then return true end
end
return false
end
-- write to a digital redstone port (applies to all RTUs)
---@param port IO_PORT
---@param value boolean

View File

@@ -26,7 +26,8 @@ local SCADA_MGMT_TYPE = comms.SCADA_MGMT_TYPE
local RTU_UNIT_TYPE = types.RTU_UNIT_TYPE
local PERIODICS = {
KEEP_ALIVE = 2000
KEEP_ALIVE = 2000,
ALARM_TONES = 500
}
-- create a new RTU session
@@ -58,7 +59,8 @@ function rtu.new_session(id, s_addr, in_queue, out_queue, timeout, advertisement
-- periodic messages
periodics = {
last_update = 0,
keep_alive = 0
keep_alive = 0,
alarm_tones = 0
},
units = {}
}
@@ -389,6 +391,14 @@ function rtu.new_session(id, s_addr, in_queue, out_queue, timeout, advertisement
periodics.keep_alive = 0
end
-- alarm tones
periodics.alarm_tones = periodics.alarm_tones + elapsed
if periodics.alarm_tones >= PERIODICS.ALARM_TONES then
_send_mgmt(SCADA_MGMT_TYPE.RTU_TONE_ALARM, { facility.get_alarm_tones() })
periodics.alarm_tones = 0
end
self.periodics.last_update = util.time()
--------------------------------------------

View File

@@ -104,8 +104,8 @@ local function _sv_handle_outq(session)
-- max 100ms spent processing queue
if util.time() - handle_start > 100 then
log.warning("[SVS] supervisor out queue handler exceeded 100ms queue process limit")
log.warning(util.c("[SVS] offending session: ", session))
log.debug("[SVS] supervisor out queue handler exceeded 100ms queue process limit")
log.debug(util.c("[SVS] offending session: ", session))
break
end
end
@@ -198,7 +198,7 @@ end
---@param nic nic network interface device
---@param fp_ok boolean front panel active
---@param num_reactors integer number of reactors
---@param cooling_conf table cooling configuration definition
---@param cooling_conf sv_cooling_conf cooling configuration definition
function svsessions.init(nic, fp_ok, num_reactors, cooling_conf)
self.nic = nic
self.fp_ok = fp_ok
@@ -430,7 +430,8 @@ function svsessions.establish_pdg_session(source_addr, version)
local id = self.next_ids.pdg
pdg_s.instance = pocket.new_session(id, source_addr, pdg_s.in_queue, pdg_s.out_queue, config.PKT_TIMEOUT, self.fp_ok)
pdg_s.instance = pocket.new_session(id, source_addr, pdg_s.in_queue, pdg_s.out_queue, config.PKT_TIMEOUT, self.facility,
self.fp_ok)
table.insert(self.sessions.pdg, pdg_s)
local mt = {

View File

@@ -21,7 +21,7 @@ local supervisor = require("supervisor.supervisor")
local svsessions = require("supervisor.session.svsessions")
local SUPERVISOR_VERSION = "v0.20.2"
local SUPERVISOR_VERSION = "v1.0.0"
local println = util.println
local println_ts = util.println_ts
@@ -48,11 +48,16 @@ cfv.assert_type_num(config.PKT_TIMEOUT)
cfv.assert_min(config.PKT_TIMEOUT, 2)
cfv.assert_type_int(config.NUM_REACTORS)
cfv.assert_type_table(config.REACTOR_COOLING)
cfv.assert_type_int(config.FAC_TANK_MODE)
cfv.assert_type_table(config.FAC_TANK_DEFS)
cfv.assert_type_str(config.LOG_PATH)
cfv.assert_type_int(config.LOG_MODE)
assert(cfv.valid(), "bad config file: missing/invalid fields")
assert((config.FAC_TANK_MODE == 0) or (config.NUM_REACTORS == #config.FAC_TANK_DEFS),
"bad config file: FAC_TANK_DEFS length not equal to NUM_REACTORS")
cfv.assert_eq(#config.REACTOR_COOLING, config.NUM_REACTORS)
assert(cfv.valid(), "config: number of cooling configs different than number of units")
@@ -61,6 +66,7 @@ for i = 1, config.NUM_REACTORS do
assert(cfv.valid(), "config: missing cooling entry for reactor " .. i)
cfv.assert_type_int(config.REACTOR_COOLING[i].BOILERS)
cfv.assert_type_int(config.REACTOR_COOLING[i].TURBINES)
cfv.assert_type_bool(config.REACTOR_COOLING[i].TANK)
assert(cfv.valid(), "config: missing boilers/turbines for reactor " .. i)
cfv.assert_min(config.REACTOR_COOLING[i].BOILERS, 0)
cfv.assert_min(config.REACTOR_COOLING[i].TURBINES, 1)

View File

@@ -32,7 +32,8 @@ function supervisor.comms(_version, nic, fp_ok)
-- configuration data
local num_reactors = config.NUM_REACTORS
local cooling_conf = config.REACTOR_COOLING
---@class sv_cooling_conf
local cooling_conf = { r_cool = config.REACTOR_COOLING, fac_tank_mode = config.FAC_TANK_MODE, fac_tank_defs = config.FAC_TANK_DEFS }
local self = {
last_est_acks = {}
@@ -295,16 +296,10 @@ function supervisor.comms(_version, nic, fp_ok)
local s_id = svsessions.establish_crd_session(src_addr, firmware_v)
if s_id ~= false then
local cfg = { num_reactors }
for i = 1, #cooling_conf do
table.insert(cfg, cooling_conf[i].BOILERS)
table.insert(cfg, cooling_conf[i].TURBINES)
end
println(util.c("CRD (", firmware_v, ") [@", src_addr, "] \xbb connected"))
log.info(util.c("CRD_ESTABLISH: coordinator (", firmware_v, ") [@", src_addr, "] connected with session ID ", s_id))
_send_establish(packet.scada_frame, ESTABLISH_ACK.ALLOW, cfg)
_send_establish(packet.scada_frame, ESTABLISH_ACK.ALLOW, { num_reactors, cooling_conf })
else
if last_ack ~= ESTABLISH_ACK.COLLISION then
log.info("CRD_ESTABLISH: denied new coordinator [@" .. src_addr .. "] due to already being connected to another coordinator")

View File

@@ -333,14 +333,28 @@ function unit.new(reactor_id, num_boilers, num_turbines)
--#region redstone I/O
local __rs_w = self.io_ctl.digital_write
-- create a generic valve interface
---@nodiscard
---@param port IO_PORT
local function _make_valve_iface(port)
---@class unit_valve_iface
local iface = {
open = function () self.io_ctl.digital_write(port, true) end,
close = function () self.io_ctl.digital_write(port, false) end,
-- check valve state
---@nodiscard
---@return 0|1|2 0 for not connected, 1 for inactive, 2 for active
check = function () return util.trinary(self.io_ctl.is_connected(port), util.trinary(self.io_ctl.digital_read(port), 2, 1), 0) end
}
return iface
end
-- valves
local waste_pu = { open = function () __rs_w(IO.WASTE_PU, true) end, close = function () __rs_w(IO.WASTE_PU, false) end }
local waste_sna = { open = function () __rs_w(IO.WASTE_PO, true) end, close = function () __rs_w(IO.WASTE_PO, false) end }
local waste_po = { open = function () __rs_w(IO.WASTE_POPL, true) end, close = function () __rs_w(IO.WASTE_POPL, false) end }
local waste_sps = { open = function () __rs_w(IO.WASTE_AM, true) end, close = function () __rs_w(IO.WASTE_AM, false) end }
local emer_cool = { open = function () __rs_w(IO.U_EMER_COOL, true) end, close = function () __rs_w(IO.U_EMER_COOL, false) end }
local waste_pu = _make_valve_iface(IO.WASTE_PU)
local waste_sna = _make_valve_iface(IO.WASTE_PO)
local waste_po = _make_valve_iface(IO.WASTE_POPL)
local waste_sps = _make_valve_iface(IO.WASTE_AM)
local emer_cool = _make_valve_iface(IO.U_EMER_COOL)
---@class unit_valves
self.valves = {
@@ -719,6 +733,27 @@ function unit.new(reactor_id, num_boilers, num_turbines)
return false
end
-- check if the reactor is connected, is stopped, the RPS is not tripped, and no alarms are active
---@nodiscard
function public.is_safe_idle()
-- can't be disconnected
if self.plc_i == nil then return false end
-- reactor must be stopped and RPS can't be tripped
if self.plc_i.get_status().status or self.plc_i.get_db().rps_tripped then return false end
-- alarms must be inactive and not tripping
for _, alarm in pairs(self.alarms) do
if not (alarm.state == AISTATE.INACTIVE or alarm.state == AISTATE.RING_BACK) then return false end
end
return true
end
-- check if emergency coolant activation has been tripped
---@nodiscard
function public.is_emer_cool_tripped() return self.emcool_opened end
-- get build properties of machines
--
-- filter options
@@ -813,7 +848,12 @@ function unit.new(reactor_id, num_boilers, num_turbines)
end
-- basic SNA statistical information
status.sna = { #self.snas, public.get_sna_rate() }
local total_peak = 0
for i = 1, #self.snas do
local db = self.snas[i].get_db() ---@type sna_session_db
total_peak = total_peak + db.state.peak_production
end
status.sna = { #self.snas, public.get_sna_rate(), total_peak }
-- radiation monitors (environment detectors)
status.rad_mon = {}
@@ -864,6 +904,19 @@ function unit.new(reactor_id, num_boilers, num_turbines)
}
end
-- get valve states
---@nodiscard
function public.get_valves()
local v = self.valves
return {
v.waste_pu.check(),
v.waste_sna.check(),
v.waste_po.check(),
v.waste_sps.check(),
v.emer_cool.check()
}
end
-- get the reactor ID
---@nodiscard
function public.get_id() return self.r_id end

View File

@@ -10,11 +10,13 @@ local qtypes = require("supervisor.session.rtu.qtypes")
local RPS_TRIP_CAUSE = types.RPS_TRIP_CAUSE
local TRI_FAIL = types.TRI_FAIL
local CONTAINER_MODE = types.CONTAINER_MODE
local DUMPING_MODE = types.DUMPING_MODE
local PRIO = types.ALARM_PRIORITY
local ALARM_STATE = types.ALARM_STATE
local TBV_RTU_S_DATA = qtypes.TBV_RTU_S_DATA
local DTV_RTU_S_DATA = qtypes.DTV_RTU_S_DATA
local IO = rsio.IO
@@ -327,13 +329,14 @@ function logic.update_annunciator(self)
--[[
Generator Trip
a generator trip is when a generator suddenly and unexpectedly loses it's external load
oftentimes this is when a power plant is disconnected from the grid for one reason or another
in this case we just:
- check if internal power storage of turbine is increasing
that means there is no external load and there will be a turbine trip soon if this is not resolved
a generator trip is when a generator suddenly and unexpectedly loses it's external load, which occurs when a power plant
is disconnected from the grid. in our case, this is when the turbine is disconnected, or what it's connected to becomes
fully charged. this is identified by detecting if:
- the internal power storage of the turbine is increasing AND
- there is at least 5% energy fill (preventing false trips with periodic power extraction from other mods)
this would then mean there is no external load and there will be a turbine trip soon if this is not resolved
]]--
self.db.annunciator.GeneratorTrip[idx] = _get_dt(DT_KEYS.TurbinePower .. idx) > 0.0
self.db.annunciator.GeneratorTrip[idx] = (_get_dt(DT_KEYS.TurbinePower .. idx) > 0.0) and (db.tanks.energy_fill > 0.05)
--[[
Turbine Trip
@@ -504,9 +507,6 @@ function logic.update_alarms(self)
local rcs_trans = any_low or any_over or gen_trip or annunc.RCPTrip or annunc.MaxWaterReturnFeed
-- only care about RCS flow low early with boilers
if self.num_boilers > 0 then rcs_trans = rcs_trans or annunc.RCSFlowLow end
-- annunciator indicators for these states may not indicate a real issue when:
-- > flow is ramping up right after reactor start
-- > flow is ramping down after reactor shutdown
@@ -828,6 +828,16 @@ function logic.handle_redstone(self)
end
end
-- make sure dynamic tanks are allowing outflow
for i = 1, #self.tanks do
local session = self.tanks[i] ---@type unit_session
local tank = session.get_db() ---@type dynamicv_session_db
if tank.state.container_mode == CONTAINER_MODE.FILL then
session.get_cmd_queue().push_data(DTV_RTU_S_DATA.SET_CONT_MODE, CONTAINER_MODE.BOTH)
end
end
if self.db.annunciator.EmergencyCoolant > 1 and not self.emcool_opened then
log.info(util.c("UNIT ", self.r_id, " emergency coolant valve opened"))
log.info(util.c("UNIT ", self.r_id, " turbines set to dump excess steam"))